Sample Specification Guideline for Installing a Polished Overlay Using Rapid Set TRU Self-Leveling SECTION 03 35 53 POLISHED CONCRETE TOPPING



Similar documents
ARDEX GUIDE SPECIFICATION ARDEX PC-T POLISHED CONCRETE TOPPING Part of the ARDEX Polished Concrete System (APCS)

SECTION POLISHED CONCRETE FINISHING

SECTION POLISHED CONCRETE FINISHING. InovaCrete Polished Concrete Floor Finish (GUIDE SPEC)

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

CONCRETE FLOOR REPAIR/REMODEL SAMPLE SPECIFICATION LIGHT TRAFFIC RETAIL/COMMERCIAL APPLICATION

Division 9. SignaFlor Pad and Pour Flooring System

SECTION Formatted Specification for the ULTRAFLOR DIAMATIC Topical Polished Concrete System DRAFT

ARDEX GUIDE SPECIFICATION

Section Polished Concrete Finishing. Vexcon

SECTION RESURFACING CAST IN PLACE CONCRETE

GUIDELINES FOR POLISHED CONCRETE FLOORS A Guide for Integrally Colored, Dyed and Stained Polished Floors

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

Moisture and Resilient Floor Covering

BENTLEY ELEMENTS COLLECTION LVT

Vinyl Composition Tile Installation System

Epoxy Floor Coating Problem Solving Guide

INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA

AC Tech Project Survey

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

Resurfacing Concrete. Page 1 of 5

ARDEX GUIDE SPECIFICATION

SECTION POLISHED CONCRETE FLOOR FINISHING

Installation System. Existing Resilient Sheet Floors

738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted )

Technical Services. Product MM INCH Installation direction Seams treatment GTI CONNECT (interlocking)

Example Specification for Concrete using Current Building Code Requirements

SECTION PLAYGROUND SURFACING TILES

CA-48 TECHNICAL SPECIFICATION

These recommendations generally follow the Construction Specifications Institute (CSI) Master Format.

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

Wecryl Waterproofing System under surfacing supplied by others

FIVE STAR PRODUCTS, INC. (800)

C. Section TESTING LABORATORY SERVICE.

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

12 POLYURETHANE ADHESIVE (PU 105)

RESILIENT TILE FLOORING INCLUDING SOLID VINYL AND LINOLEUM FLOOR TILE

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

Carpet Tile Installation Guidelines

SPECIFICATIONS. INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP)

SECTION 1 GENERAL REQUIREMENTS

Bella Cera Engineered Hardwood Flooring Installation Instructions. Check for Proper Color Selection Prior to Installation

Moisture Mitigation for Concrete Slabs

SECTION PERMEABLE INTERLOCKING CONCRETE PAVEMENT

Concrete Repair. Applications and Procedures

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

GUIDE SPECIFICATION COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL

TECHNICAL SPECIFICATIONS CEMENT-BENTONITE SLURRY TRENCH CUTOFF WALL

WATERPROOFING FOR CONCRETE STRUCTURES

SC2000 CEMENT BONDING PROCEDURES

SECTION 4Aggegate Subbase

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Adhesive Recommendation for Altro Flooring. Porous (absorbent) subfloors (most wood subfloors and some concrete)

APPENDIX C MOISTURE GUIDELINES & MOISTURE TESTING

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

3M Scotchkote Urethane Coating 165HB

Sikaflex Sealant Installation. Sika Corporation

Minor Cracks in Horizontal Surfaces

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

1.1 This section is to be utilized for polishing both integral colored or natural gray concrete floors.

SECTION 311 PLACEMENT AND CONSTRUCTION OF CEMENT TREATED SUBGRADESOIL CEMENT BASE COURSE

LOWELL REGIONAL WASTEWATER UTILITY SPECIFICATIONS FOR THE LOWELL MA CONCRETE FLOODWALL REPAIRS

Division 2 Section Section 02795

Moisture Testing of Concrete Slabs

Treatment of a surface or structure to resist the passage of water in the absence of hydrostatic pressure. presence of hydrostatic pressure.

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

STERI-SOFT HIGH FOOT TRAFFIC, ULTRAVIOLET RESISTANT, URETHANE RESILIENT FLOORING SYSTEM, 1/8 GREEN BUILDING FEATURES TYPICAL APPLICATIONS

TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL Pre-Insulated Piping

Mold Preventing I nterior System

Guide Specifications for Maple Flooring Systems

WATERPROOFING OF WET ROOMS

SMOOTHMOVE INSTRUCTIONS FURNITURE VAN EPOXY FLOOR FINISH KIT VOC-FREE - NO SOLVENT GENERAL INFORMATION KEY 87269AB

weber.floor 4660 Marine Elastic (EN)

MASONRY RESTORATION Lime Putty Mortar Repointing Guide

The Art of Concrete 9/17/2012. ACI Spring 2012 Convention March 18 21, Dallas, TX. Amerete, Inc. started in 2004 as American Concrete Technologies

DIVISION 300 BASES SECTION 304 AGGREGATE BASE COURSE DESCRIPTION MATERIALS CONSTRUCTION REQUIREMENTS

K2 STONE NATURAL VENEER

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

MINIMUM QUALITY CONTROL PLAN FOR FIELD PLACEMENT OF LATEX MODIFIED MORTAR OR CONCRETE WEARING SURFACE

Armstrong Do-It-Yourself Tile Installation System

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

Tecnoepo Flooring System 185

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

LAYING BLOCK AND BRICK

CHAPTER 3 MOISTURE TESTING

STANDARD SPECIFICATIONS SECTION PRECAST REINFORCED CONCRETE MANHOLES AND MANHOLE BASES. 1. Structure Earthwork: 02200

Colorado State University. Durrell Center Roof Repair

Section SEWER PIPE INSTALLATION AND TESTING

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

FACT SHEET: HYDRATED LIME FOR MASONRY PURPOSES

Specifications. PermaTone, Inc. Manufacturer s Long Form Specifications Interior Finish Coatings PF-405

Amtico and Spacia Commercial Maintenance Guidelines

SECTION PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795)

GigaCrete Specification PlasterMax

BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:

E. CONCRETE. Chapter III Subfloors and Underlayments

HARDWOOD WARRANTIES Limited Warranty for Prefinished Solid, Engineered, and Longstrip Floors Manufacturing Defects Finish Warranty

Care and Maintenance for Wood Flooring

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

Transcription:

Sample Specification Guideline for Installing a Polished Overlay Using Rapid Set TRU Self-Leveling SECTION 03 35 53 POLISHED CONCRETE TOPPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of contract, including general and supplementary conditions apply to this section. 1.2 SUMMARY A. Section includes: 1. A Rapid Set TRU Self-Leveling Concrete Topping finished to a specified finish using traditional dry concrete polishing techniques. 2. Application of a primer coat using Rapid Set TXP Epoxy Primer. 3. Furnish all labor, materials, equipment and services necessary for the dry diamond grinding and polishing of the Rapid Set TRU Self-Leveling floor in accordance with industry recommended standards. 4. Application of Metzger/McGuire semi-rigid joint filler to fill and protect joints. 5. Application of a densifier and stain protector/guard to inhibit absorption of liquid into the surface, thereby minimizing the potential for discoloration due to staining. 1.3 REFERENCES A. ASTM C109 Standard Test Method for Determining the Compressive Strength of Hydraulic Cement Mortars using 2 inch or 50 mm Cube Specimens. B. ASTM C1028 Standard Test Method for Determining the Static Coefficient of Friction of Ceramic Tile and Other Like Surfaces by the Horizontal Dynamometer Pull-Meter Method. C. ASTM F1869 Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Chloride. D. ASTM F710 Standard Practice for Preparing Concrete Floors to Receive Resilient Flooring. E. ASTM F2170 Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in-situ Probes. F. ASTM E430 Standard Test Methods for Measurement of Gloss of High-Gloss Surface by Abridged Goniophotometry. G. ACI 302. R-04 Guide for Concrete Floor and Slab Construction. 1.4 SUBMITTALS A. Submit the following in accordance with Division Section Submittal Procedures.

B. Product data for the Rapid Set TRU Self-Leveling to include physical characteristics, product limitations, and manufacturer s installation instructions to include recommended mix designs for the intended application. C. Product data for the Rapid Set LevelFlor, Rapid Set Cement All and Rapid Set Concrete Mix to include physical characteristics, product limitations, and manufacturer s installation instructions to include recommended mix designs for the intended application. D. Product data for Metzger/McGuire Rapid Refloor Low Viscosity Structrual Urethane surface repair material, Metzger/Mcguire Spal-Pro RS 88 Semi-Rigid Polyurea Joint Filler or MM-80 Semi-Rigid Epoxy Joint Filler. E. Product data for Husqvarna GM 3000 grout compound. F. Product data for approved densifier and stain protector/guard to include product limitations and manufacturer s instructions for installation. G. Installer Qualifications Provide project names, addresses, contact names, phone numbers of at least three (3) projects of similar scope completed by the installer. H. Maintenance procedures for cleaning and maintaining the surface of the finished installation to include cleaning and polishing equipment and the use of Diamond Cleaning Pads for maintenance. 1.5 QUALITY ASSURANCE A. Installer Qualifications: Installer must be trained and certified by all manufacturers as follows: 1. A TRU Trained Applicator is one that has been trained in the methods of placing self-leveling products and the understanding of products by CTS Cement Manufacturing Corporation. 2. A TRU Premier Trained Applicator is one that has been trained in the methods of placing self-leveling products and the understanding of products by CTS Cement Manufacturing Corporation, and has a minimum of five (5) years company experience in finished floor installations, and at least 20 finished floor installations greater than 5,000 sq. ft. B. CTS Cement Manufacturing Corporation also recommends the installer have a minimum of 10 projects performed within three (3) years of similar type, size and complexity as this contract. C. Manufacturer s Training Course Completion: Provide a letter of training completion from all equipment and material manufacturers confirming that the installer is a trained applicator and is familiar with proper procedures and installation requirements recommended by the manufacturer. D. Manufacturer to provide confirmation of installation procedures. E. Place field sample (mock up) of TRU Self-Leveling, surface repair materials, and all other finishes to the required specification of the finished floor. Accepted field sample shall remain in place and shall be the guide to acceptance of the balance of installation. F. Field sample must also include specified edge finish, which must be specified and approved by the architect/owner s representative since edge-grinding procedures may not produce the exact same finish as the field. G. Pre-Installation Meeting - Prior to the installation of the polished overlay, an onsite meeting shall be organized to review specification requirements. Attendees

to include the Owner, Architect, General Contractor, Subcontractor, and Rapid Set representative. 1.6 ENVIRONMENTAL LIMITATIONS/REQUIREMENTS A. Comply with manufacturer s written instructions for substrate temperature and moisture content, ambient temperature and humidity, ventilation and other conditions affecting product performance. B. Flatness and levelness: 1. Installed and finished topping shall meet flatness and levelness requirements as specified. 2. Installed topping shall be cured a minimum of four (4) hours or at which point equipment can be put on the slab and does not cause indentation. C. General Contractor shall protect areas to receive polished concrete topping at all times during construction to prevent oils, dirt, metal, excessive water and other potentially damaging materials from affecting the finished concrete surface. Protection measures listed below shall begin immediately after the concrete slab is poured: 1. All hydraulic-powered equipment shall be diapered to avoid staining of the concrete. 2. All vehicle parking shall be prohibited on the finished slab area. 3. If necessary to complete their scope of work, drop cloths shall be placed under vehicles at all times. 4. No pipe-cutting machine shall be used on the finish floor slab. 5. Steel shall not be placed on the finish slab to avoid rusting. 6. Acids and acidic detergents will not come in contact with slab. 7. All painters will use drop cloths on the concrete. If paint gets on the concrete, it must be immediately removed. 8. All trades will be informed that the slab must be protected at all times. D. Installed topping area shall be closed to traffic during finish floor application and after application for the length of time recommended by the manufacturer. 1.7 DELIVERY, STORAGE AND HANDLING A. Deliver all materials in original containers. B. Maintain records of manufacturer s product lot numbers. C. Store all materials in a dry, climate-controlled environment at a minimum of 50 F and a maximum of 85 F. 1.8 SITE CONDITIONS A. Rapid Set TRU Self-Leveling is a hydraulic cement-based topping. The ideal temperature at time of installation is 70 F for both the surface and ambient air. Warmer material will set faster than expected and cooler material will have slower strength gain. Control the mix temperature by protecting the bags of TRU from temperature extremes and adjust the mix temperature by using hot or cold water. For further information contact CTS Cement at 800-929-3030. B. Existing concrete must have a minimum compressive strength of 3000 psi and a minimum density of 100 pcf (pounds per cubic foot).

C. Close off areas during the installation of TRU Self-Leveling from all traffic and stop excessive air movement across the top of the surface until Rapid Set TRU has reached final set. See 1.6 (D) for protecting the polished topping. D. Moisture Vapor and Alkalinity Testing: 1. No Moisture Vapor Transmission Barrier is required when the Rapid Set TXP Epoxy Primer is placed in accordance with manufacturer s instructions. 2. Rapid Set TXP will remain unaffected by Moisture Vapor Transmission and alkalinity up to ph 14. 3. Please contact the CTS Cement Technical Department at 800-929-3030 for technical information or guidelines for applications that will not involve polishing as the finished surface. PART 2 - PRODUCTS 2.1 INSTALLATION MATERIALS A. Concrete Repair Materials and Toppings 1. Self-Leveling Concrete Topping shall be Rapid Set TRU Self-Leveling or equivalent calcium sulfoaluminate cement-based topping suitable to receive a mechanical concrete polish in wet and dry environments. a) Performance and Physical Properties i. Working time: 20 minute minimum ii. Flow time: 15 minute minimum iii. Compressive Strength: ASTM C109 a. 4 hr: 2800 psi (19.3 MPa) b. 24 hr: 5000 psi (34.5 MPa) c. 28 day: 7000 psi (48.3 MPa) iv. Flexural Strength: ASTM C348 a. 24 hr: 850 psi (5.9 MPa) b. 28 day: 1900 psi (13.1 MPa) b) Utilize manufacturer s recommended specifications, proportions, mix ratios, additives and proprietary components as required for specific applications, and as approved by Architect/Engineer. c) Water shall be clean and potable. 2. Primer shall be Rapid Set TXP Epoxy Primer or equivalent 100% solids, twocomponent, moisture and alkali insensitive epoxy primer. 3. Surface defect material shall be from one of the following products: a) Rapid Set TRU Self-Leveling (0.25-1.5ʺ depth neat, up to 5ʺ extended) b) Rapid Set LevelFlor Self-Leveling Underlayment (0.25-1.0ʺ depth neat, up to 5ʺ extended) c) Rapid Set Cement All (0-4ʺ depth) d) Rapid Set Mortar Mix (0.5-6ʺ depth) e) Rapid Set Concrete Mix (2-24ʺ depth) f) Rapid Set TXP Epoxy Primer (1 part TXP to 1.5 parts silica sand) g) Metzger/McGuire Rapid Refloor 4. Integral color shall be liquid pigment only. Contact CTS Cement for approved color manufacturers.

B. Concrete Chemical Treatments 1. Densifier to be 2. Stain Guard to be C. Joint and Crack Filler Materials 1. Saw Cut Contraction/Construction Joint Filler and Crack Filler shall be one of the following, depending upon site conditions and at the discretion of the installation contractor: b. Metzger/McGuire Spal-Pro RS 88 Semi-Rigid Polyurea Joint Filler. c. Metzger/McGuire MM-80 /MM-80P Semi-Rigid Polyurea Joint Filler. d. Metzger/McGuire Rapid Refloor. 2. Color to match adjacent finished floor surface. D. Aggregate Materials and Design Features 1. Special aggregates and design feature strips shall be as agreed to by the designer and the installer and shall be within recommended guidelines of the manufacturer. 2.2 EQUIPMENT A. Polishing Equipment 1. Three-phase 480 volt generator and step-down transformer or have certified electrician wire to house power through distribution boxes or transformers. 2. Three (3) head or four (4) head counter rotating variable speed approved floor grinder with at least 650 pounds down pressure. 3. Dust extraction system, pre-separator, and squeegee attachments with minimum flow rating 580 cubic feet per minute. 4. Hand grinder with dust extraction attachment and pads. PART 3 - EXECUTION 3.1 PREPARATION A. Installer shall examine and approve concrete substrate for conditions affecting performance of finish. Installer shall correct conditions that are found to be out of compliance with the requirements of this section to include installing a preleveling layer as recommended by CTS Cement Manufacturing Corporation. B. All surface defects shall be repaired using materials described in 2.1 A. C. All joints and cracks shall be repaired using the material described in 2.1 C. D. Provide a concrete substrate surface that has been mechanically prepared to an ICRI CSP 3 and is clean of all contaminants and debris. E. If application includes divider/terrazzo strips, level and set strips to appropriate heights prior to the pour of the TRU Self-Leveling. F. Pin or otherwise mark all existing joint locations to ensure they can be located and re-saw cut after placement of topping. G. Prime the prepared concrete using Rapid Set TXP Epoxy Primer in accordance with manufacturer s recommendations and time restrictions. H. Broadcast washed and kiln dried angular cut silica sand onto Rapid Set TXP Epoxy Primer prior to initial set. Broadcast to refusal.

I. After epoxy primer cures, vacuum up all loose silica sand. 3.2 TOPPING APPLICATION Install Rapid Set TRU Self-Leveling in accordance with manufacturer s instructions to include careful monitoring of the amount of mix water being used, with allowance for the following special designs: A. Any aggregates used and the loading shall be as recommended and approved by the topping manufacturer. B. Integral color shall be approved by CTS Cement Manufacturing Corporation. C. Specifed color to be. D. Batch mixers by CS Unitec (Hippo Mixer) or Strong Manufacturing are the preferred methods of mixing the TRU Self-Leveling for polished overlays. E. If Barrel Mixing, use a 1/2ʺ heavy-duty drill (12 mm) with a minimum of 650 rpm. Mix two (2) bags of TRU Self-Leveling with the specified amount of water in a mixing barrel using a helix style mixing paddle. Mix thoroughly for 3-5 minutes to obtain a lump-free mixture. F. Clean barrels/mixers periodically or use a 1/8ʺ screen (#8 Classifier) to remove any unmixed and/or hardened material prior to placing the mixed TRU Self- Leveling onto the floor. G. Place TRU Self-Leveling to grade levels required and to conform to details on drawings. H. The minimum installation thickness for the Rapid Set TRU Self-Leveling topping shall be 3/8ʺ. For fork lift traffic areas nominal thickness shall be no less than ½ʺ. Refer to the Technical Bulletins or contact CTS Cement Manufacturing for more information. I. Pre-Leveling Aggregate Mix Design - For wide area repairs that require thicknesses greater than 1.0ʺ with Rapid Set LevelFlor and greater than 1.5ʺ with Rapid Set TRU Self-Leveling, washed pea gravel may be added to reduce material costs. Mix the material with water first then extend each 50-pound bag with up to 25 pounds of clean 3/8" pea gravel. Place the extended material to ⅜ʺ ½ʺ below the desired floor elevation and then place Rapid Set TRU to the finished floor elevation. Allow the pre-leveling course to dry for 12-16 hours. J. Pour or pump the Rapid Set TRU Self-Leveling and spread in place with a gauge rake set at the appropriate thickness. Use the Rapid Set Spike Roller to coax the material into place. Use rounded metal spiked shoes to avoid damaging the primer. Contact the CTS Cement Technical Department if other tools are required. 3.3 JOINT SAWING, PREPARATION AND FILLING A. Allow topping to cure for a minimum of four (4) hours prior to saw cutting joints. B. Joints must be installed prior to the polishing process C. Locate original joint locations and saw cut through topping into the original joint. Saw blade shall penetrate to depth of original joint or 2 deep, whichever is the lesser. D. Ensure saw-cut joint is completely free of dust/debris/laitance. E. Apply stain prevention film or other masking agent along surface on both sides of the joint if residual staining may be a concern.

F. Install joint filler. Fill from bottom of joint, being careful to avoid entrapping air. G. Slightly overfill joint to a crowned profile. H. After sufficient cure, razor excess filler, leaving a filler profile which is flush with floor surface. I. If filler profile is low/concave, remove top ½ of filler and re-apply. 3.4 POLISHING A. Allow to cure for a minimum of 24 hours before beginning the polishing process. B. Use an approved TRU Self-Leveling overlay polishing system from: HTC, SASE, Husqvarna, or Lavina. C. Apply densifier and stain protector per manufacturer s recommendations. D. Refer to the CTS Cement Technical Bulletins for more information. 3.5 PROTECTION A. Protect the finished surfaces from damage and soiling and other construction activities. B. Provide protective cover without damaging the polished surface. C. Don t allow standing water, rubber matting, or other non-breathable objects onto the polish surface for a period of 72 hours after final surface treatment. 3.6 SHEEN A. Polished Concrete Level 1: 1. At a distance of 100 feet, the floor will reflect images from side lighting. B. Polished Concrete Level 2: 1. At a distance of 30 to 50 feet, the floor will clearly reflect from side and overhead lighting. C. Polished Concrete Level 3: 1. Looking straight down, the floor will clearly reflect overhead and side light, with the appearance of the floor looking wet.