MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING



Similar documents
EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

MXS 3. MANUAL FULLY CHARGED PULSE, MAINTENANCE CHARGING EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT CHARGE CABLE ERROR LAMP MODE- BUTTON

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

MULTI XS 4003 Battery charger

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel

BATTERY CHARGER MULTI US 7000

MANUAL CONGRATULATIONS IMPORTANT SAFETY INSTRUCTIONS

Battery charger. Art.no Model CB5-5L-BS1 ENGLISH SVENSKA NORSK SUOMI. Ver Original instructions

QUICK PROBLEM SOLVING GUIDE

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

read or understand the manual

Manual. Solar Fountain Mobile Phone Charger

Installation and Operating Instructions (for chargers shown below)

13 Watt PORTABLE SOLAR POWER KIT

12 Volt 30 Amp Digital Solar Charge Controller

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

400 Amp Rechargeable Jump Start System RAC-HP082

Solar Controller / Battery Charger User s Manual

Installation and Operating Instructions (for chargers shown below)

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

User s Manual Before using the inverter, you need to read and save the safety instructions.

OUTPUT CABLE CONNECTIONS:

CHARGING SYSTEMS INTERNATIONAL

SOLAR POWER - THE NEW WAY TO RV!

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

How To Use A Power Supply Unit (Upu)

HM-W536 Install Guide

TIG INVERTER INSTRUCTION MANUAL

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Instructional & Operating Manual

Installation and operating instructions. Solar charge controller Solarix MPPT Z Z

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

TruPower-Portable-500W. Solar Starter kit

GEN Series. On-Board Battery Chargers. Owner s Manual & User Guide

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

If you accidentally get battery acid on your skin, flush it with lots of water

Portable Air Conditioner

Battery Power Inverters

3000W Power Inverter

2/8/12 AMP Smart Charger OWNER S MANUAL

ST Series POWER SUPPLIES USER INSTRUCTIONS

Thyristor-controlled power supplies and battery chargers

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

Operating Instructions

Operating Instructions Bedienungsanleitung Mode d emploi

POWER TO GET THE JOB DONE

Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

User s Manual AURORA 1.2K/2.2K

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

INFRARED QUARTZ WALL HEATER

GENANO 4500 MEDICAL AIR PURIFICATION DEVICE

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

Ultrasonic support removal tank

Lithium Jump Starter and DC Power Source

THIS MANUAL REFERS TO THE FOLLOWING MODULES G G G G EG EG EG EG

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Phoenix Multi 120Vac 12/1600/70 12/2500/120 24/1600/40 24/3000/70. Phoenix MultiPlus 120Vac 12/2500/120 24/3000/70

Infrarot-Bewegungsmelder IP44

Proportional pressure regulators VPPE

Battery Management Innovation DIAGNOSTIC CONDUCTANCE CHARGER. For testing and charging 12-volt automotive batteries INSTRUCTION MANUAL

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Bosch C3 and C7 Battery Chargers: Smart, safe and simple to use

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

instabus KNX / EIB System System E F G H

BroadBand PowerShield. User Manual

ELECTRIC INSTANTANEOUS WATER HEATER

Product and functional description

3 WATT LED SPOTLIGHT Model No. SLM

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

BATTERY CHARGING GUIDELINES FOR 6-VOLT DEEP CYCLE BATTERIES

ATL Fuel Level Sender Probes

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Operating Manual Remote Cost Control Monitor

Mounting instruction Read instructions carefully!

Charge Regulator SCR 12 Marine

Temperature Compensated Charging of Lead Acid Batteries

Contact Details. Please note that some of the contact details on this PDF document may not be current.

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

is then retained absolutely without interruption.

BATTERY SERVICE. This Automotive Series BATTERY SERVICE has been developed by. Kevin R. Sullivan. Professor of Automotive Technology Skyline College

Transcription:

MODE 12V/ MANUAL CONGRATULATIONS to the purchase of your new professional switch mode battery charger. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the latest technology in battery charging. CTEK COMFORT CONNECT PLUG* MAINS CABLE CHARGING 1. Connect the charger to the battery. 2. Connect the charger to the wall socket. The power lamp will indicate that the mains cable is connected to the wall socket. The error lamp will indicate if the battery clamps are incorrectly connected. The reverse polarity protection will ensure that the battery or charger will not be damaged. 3. Press the MODE-button to select charging program. 4. Follow the indication lamps through the charging process. The battery is ready to start the engine when is lit. The battery is fully charged when is lit. 5. Stop charging at any time by disconnecting the mains cable from the wall socket. EN ABSORPTION, READY TO USE ANALYSE CHARGE CABLE MXS 7.0 DESULPHATION SOFT START BULK FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING ERROR LAMP CTEK COMFORT CONNECT eyelet M8 CTEK COMFORT CONNECT clamp MODE- BUTTON *Supply plugs may differ to suit your wall socket. POWER LAMP BATTERY BATTERY EN 3 20015462E MXS 7.0, Manual EU, Print file 002.indd 3 2011-10-11 07:58:00

CHARGING S Settings are made by pressing the MODE-button. After about two seconds the charger activates the selected program. The selected program will be restarted next time the charger is connected. The table explains the different Charging Programs: Program Battery Size (Ah) Explanation Normal battery program 14.4V/. Use for WET batteries, Ca/Ca, MF and for most GEL batteries battery program 14.7V/ Use for batteries. Temp range +5 C +50 C (41ºF 122ºF) -20 C +5 C (-4ºF 41ºF) ERROR LAMP If the error lamp is lit, check the following: 1. Is the chargers positive lead connected to the batterys positive pole? 2. Is the charger connected to a 12V battery? 3. The clamps are short circuited? 4. Has charging been interrupted in or? Restart the charger by pressing the MODE-button. If charging is still being interrupted, the battery......is seriosly sulphated and may need to be replaced....can not accept charge and may need to be replaced....can not keep charge and may need to be replaced. Recond program 15.8V/1.5A Use to return energy to the empty WET and Ca/Ca batteries. Recond your battery once per year and after deep dischare to maximise lifetime and capacity. The Recond program adds the Recond step to the normal battery program. Frequent use of the Recond program may cause water loss in the batteries and reduce service life of electronics. Contact your vehicle and battery supplier for advice. -20 C +50 C (-4ºF 122ºF) READY TO USE The table shows the estimated time for empty battery to 80% charge Supply program 13.6V/ Use as 12V power supply or use for float maintenance charging when 100% capacity of the battery is required. Supply program activates Float step without time or voltage limitation. -20 C +50 C (-4ºF 122ºF) BATTERY SIZE (Ah) 20Ah 50Ah 100Ah 150Ah TIME TO 80% CHARGED 2h 6h 12h 17h WARNING! The spark protection on the battery charger is disabled during program. 4 EN 20015462E MXS 7.0, Manual EU, Print file 002.indd 4 2011-10-11 07:58:02

CHARGING DESULPHATION SOFT START BULK ABSORPTION ANALYSE FLOAT PULSE VOLTAGE (V) CURRENT (A) 14.4V 14.7V 1 2 3 4 5 6 7 8 until 12.6V until 12.6V 14.4V until 12.6V Increasing voltage to 14.4V @ 25 C Increasing voltage to 14.7V @ 25 C Increasing voltage to 14.4V @ 25 C 14.4V @ 25 C Declining current 14.7V @ 25 C Declining current 14.4V @ 25 C Declining current Limit: Max 8h Max 8h Max 20h Max 10h 3 minutes STEP 1 DESULPHATION Detects sulphated batteries. Pulsing current and voltage, removes sulphate from the lead plates of the battery restoring the battery capacity. STEP 2 SOFT START Tests if the battery can accept charge. This step prevents that charging proceeds with a defect battery. STEP 3 BULK Charging with maximum current until approximately 80% battery capacity. STEP 4 ABSORPTION Charging with declining current to maximize up to 100% battery capacity. Checks if voltage drops to 12V Checks if voltage drops to 12V Checks if voltage drops to 12V Max 15.8V 1.5A 30 min or 4h depending on battery voltage 13.6V 13.6V 13.6V Max 13.6V 10 days Charge cycle restarts if voltage drops* 12.9V 14.4V 7 2A 12.9V 14.7V 7 2A 12.9V 14.4V 7 2A Charge cycle restarts if voltage drops STEP 5 ANALYSE Tests if the battery can hold charge. Batteries that can not hold charge may need to be replaced. STEP 6 Choose the Recond program to add the Recond step to the charging process. During the Recond step voltage increases to create controlled gasing in the battery. Gasing mixes the battery acid and gives back energy to the battery. STEP 7 FLOAT Maintaining the battery voltage at maximum level by providing a constant voltage charge. STEP 8 PULSE Maintaining the battery at 95 100% capacity. The charger monitors the battery voltage and gives a pulse when necessary to keep the battery fully charged. *Supply program is not time or voltage limited. EN EN 5 20015462E MXS 7.0, Manual EU, Print file 002.indd 5 2011-10-11 07:58:03

MODE CONNECT AND DISCONNECT THE CHARGER TO A BATTERY MXS 7.0 12V/ INFO If the battery clamps are incorrectly connected, the reverse polarity protection will ensure that the battery and charger are not damaged. For batteries mounted inside a vehicle 1. Connect the red clamp to the battery's positive pole. 2. Connect the black clamp to the vehicle chassis remote from the fuel pipe and the battery. 3. Connect the charger to the wall socket 4. Disconnect the charger from the wall socket before disconnecting the battery 5. Disconnect the black clamp before the red clamp. Some vehicles may have positively earthed batteries. 1. Connect the black clamp to the battery's negative pole. 2. Connect the red clamp to the vehicle chassis remote from the fuel pipe and the battery. 3. Connect the charger to the wall socket 4. Disconnect the charger from the wall socket before disconnecting the battery 5. Disconnect the red clamp before the black clamp. TECHNICAL SPECIFICATIONS Charger model MXS 7.0 Model number 1053 Rated Voltage AC 220 240VAC, 50 60Hz Charging voltage 14.4V, 14.7V, 15.8V, 13.6V Start voltage 2.0V Charging current Current, mains Back current drain* Ripple** <4% Ambient temperature Charger type Battery types 7.2A max 1.2A rms (at full charging current) <1Ah/month -20 C to +50 C, output power is reduced automatically at high temperatures 8-step, fully automatic charging cycle All types of 12V lead-acid batteries (WET, MF, Ca/Ca, and GEL) 14 150Ah up to 225Ah for maintenance Battery capacity Dimensions 191 x 89 x 48mm (L x W x H) Insulation class IP65 Weight 0.8kg *) Back current drain is the current that drains the battery if the charger is not connected to the mains. CTEK chargers has a very low back current. **) The quality of the charging voltage and charging current is very important. A high current ripple heats up the battery which has an aging effect on the positive electrode. High voltage ripple could harm other equipment that is connected to the battery. CTEK battery chargers produce very clean voltage and current with low ripple. Comfort Connect rt ct 6 EN 20015462E MXS 7.0, Manual EU, Print file 002.indd 6 2011-10-11 07:58:04

SAFETY The charger is designed for charging 12V lead-acid batteries. Do not use the charger for any other purpose. Check the charger cables prior to use. Ensure that no cracks have occurred in the cables or in the bend protection. A charger with damaged cables must not be used. A damage cable must be replaced by a CTEK representative. Never charge a damaged battery. Never charge a frozen battery. Never place the charger on top of the battery when charging. Always provide for proper ventilation during charging. Avoid covering the charger. A battery being charged could emit explosive gasses. Prevent sparks close to the battery. When batteries are reaching the end of their lifecycle internal sparks may occur. All batteries fail sooner or later. A battery that fails during charging is normally taken care of by the chargers advanced control, but some rare errors in the battery could still exist. Don t leave any battery during charging unattended for a longer period of time. Ensure that the cabling does not jam or comes into contact with hot surfaces or sharp edges. Battery acid is corrosive. Rinse immediately with water if acid comes into contact with skin or eyes, seek immediate medical advice. Always check that the charger has switched to before leaving the charger unattended and connected for long periods. If the charger has not switched to within 45 hours, this is an indication of an error. Manually disconnect the charger. Batteries consume water during use and charging. For batteries where water can be added, the water level should be checked regularly. If the water level is low add distilled water. This appliance is not designed for use by young children or people who cannot read or understand the manual unless they are under the supervision of a responsible person to ensure that they can use the battery charger safely. Store and use the battery charger out of the reach of children, and ensure that children cannot play with the charger. Connection to the mains supply must be in accordance with the national regulations for electrical installations. LIMITED WARRANTY CTEK SWEDEN AB, issues this limited warranty to the original purchaser of this product. This limited warranty is not transferable. The warranty applies to manufacturing faults and material defects for 5 years from the date of purchase. The customer must return the product together with the receipt of purchase to the point of purchase. This warranty is void if the battery charger has been opened, handled carelessly or repaired by anyone other than CTEK SWEDEN AB or its authorised representatives. One of the screw holes in the bottom of the charger is sealed. Removing or damaging the seal will void the warranty. CTEK SWEDEN AB makes no warranty other than this limited warranty and is not liable for any costs other than those mentioned above, i.e. no consequential damages. Moreover, CTEK SWEDEN AB is not obligated to any warranty other than this warranty. SUPPORT CTEK offers a professional customer support: www.ctek.com. For latest revised user manual see www.ctek.com. By e-mail: info@ctek.se, by telephone: +46(0) 225 351 80, by fax +46(0) 225 351 95. By mail: CTEK SWEDEN AB, Rostugnsvägen 3, SE-776 70 VIKMANSHYTTAN, SWEDEN. VIKMANSHYTTAN, SWEDEN 2011-09-01 Bengt Hagander, President CTEK SWEDEN AB EN EN 7 20015462E MXS 7.0, Manual EU, Print file 002.indd 7 2011-10-11 07:58:05

CTEK PRODUCTS ARE PROTECTED BY 2011-09-19 Patents Designs Trade marks EP10156636.2 pending RCD 509617 CTM 669987 US12/780968 pending US D575225 CTM 844303 EP1618643 US D580853 CTM 372715 US7541778 US D581356 CTM 3151800 EP1744432 US D571179 CTM 1461716 pending EP1483817 pending RCD 321216 CTM 1025831 SE524203 RCD 000911839 CTM 405811 US7005832B2 RCD 081418 CTM 830545751 pending EP1716626 pending RCD 001119911-0001 CTM 1475420 pending SE526631 RCD 001119911-0002 CTM 1935061 pending US7638974B2 RCD 081244 V28573IP00 EP1903658 pending RCD 321198 CTM 1082141 pending EP09180286.8 pending RCD 321197 CTM 2010004118 pending US12/646405 pending ZL 200830120184.0 CTM 4-2010-500516 pending EP1483818 ZL 200830120183.6 CTM 410713 SE1483818 RCD 001505138-0001 CTM 2010/05152 pending US7629774B2 RCD 000835541-0001 CTM1042686 EP09170640.8 pending RCD 000835541-0002 CTM 766840 pending US12/564360 pending D596126 SE528232 D596125 SE525604 RCD 001705138 pending US D29/378528 pending RCD 201030618223.7 pending US RE42303 US RE42230 20015462E 8 EN 20015462E MXS 7.0, Manual EU, Print file 002.indd 8 2011-10-11 07:58:05