A small, safe, reliable and user-friendly device suitable for inpatient and outpatient use in a variety of applications



Similar documents
Multi-Therapy Smart Infusion for Home Care

Product Catalog. WalkMed Infusion, LLC 6555 S. Kenton Street Ste. 304, Centennial, CO walkmed.net. Order Toll Free:

NIKI T34 SYRINGE PUMP

CADD-legacy PCA pump Model ml Cassette

Helping to protect you from exposure to hazardous drugs

Regents of the University of Michigan 5/7/2015. Review pump functionality, sets and accessories Understand key process steps for

CRRT with Prismaflex LEADS TO More Flexibility, Ease of Use and Safety

Using a Graseby MS26 Syringe Driver for Continuous Subcutaneous Infusions (CSCI) Protocol

SIGMA Spectrum Infusion System Compatible Baxter IV Sets

with FLASH TIPS PLUM A+ INFUSION SYSTEM OPERATING INSTRUCTIONS REFER TO SYSTEM OPERATING MANUAL FOR COMPLETE OPERATING INSTRUCTIONS

Baxter Elastomeric Pumps CLINICIAN GUIDE

Power Injectors for Diagnostic Imaging

The reliable, high-quality phone for professional home calling needs with best conference calls

Covering the Spectrum

Buyers guide. Ambulatory syringe drivers CEP08046

EXACTAMIX Compounding. Systems for Specialty Pharmacies

OPERATOR S MANUAL Vet Pump

GSM ATT Modules Simply effective remote control

Disposables the Original by B. Braun

DUAL PUMPS COMMUNICATIONS CABLE

Clinical protocol for the use of syringe drivers in palliative care patients (adults)

Infusovet Veterinary Infusion Pump

OPERATOR S MANUAL. Model 6100 and Ambulatory. Infusion. Pump

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

OPERATOR S GUIDE. Syringe pump. Introduction

sbchoi~kku.edu jeremy~sooil.com DANA Diabecare IlS Insulin Infusion pump Infusion pump Class II

Freka. Enteral Feeding Tube Product Range ENTERAL NUTRITION

User Manual for use with the

NursE GuidEliNEs NURSE GUIDELINES

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

DISTRIBUTION: All Clinical Units JHCH, J1, J2, H1, Oncology Day Stay Unit & J2 Day Stay Unit. JHH Intensive Care Unit and Emergency Department

Everything you need for protection scheme testing

User Guide. Temperature and Humidity Datalogger. Model 42280

Multi-Range Programmable DC Power Supplies 9115 Series

Humulin R (U500) insulin: Prescribing Guidance

PROGRAMMABLE LOGIC CONTROL

NOTICE INVITING e-tender

INSTALLATION AND OPERATING INSTRUCTIONS

Eliminating Infusion Confusion. Agenda

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

User's Guide. Integrating Sound Level Datalogger. Model Introduction

CONSOLES R E G I A S E R I E S LIGHTING

CYMAQ Marking System AS200 + DS7050 N-14

INSTALLATION MANUAL XM3 Reader

A Powerful, Flexible and More Ergonomically Evolved Perfusion System

Safe medication. Disposable syringes

Design of an Insulin Pump. Purpose of an Insulin Pump:

Intravenous Infusion Lines Enhancing Patient Safety During IV Therapy

Smile 11 AS-i Emergency stop with safe AS-i input node

Handheld portable appliance testers

S Y R I N G E P U M P S

Product Information Sheet UH36 Hi Pot Tester

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

STAY COMPLIANT. MAKE P-TOUCH AN ESSENTIAL PART OF YOUR KIT.

COOLING THERAPY SYSTEM

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI

How to design an insulin pump

TC-9102 Series Surface Mount Temperature Controllers

Date effective: Jan 2005 Date revised: June 2015

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

I.V. Administration Extension Sets / Gravity Administration Sets

A4.7 Management of a totally occluded central catheter and persistent withdrawal occlusion (PWO)

VEHICLE DIAGNOSTICS THE AUTOCOM WAY

DataView DVTH Data Logger for Temperature and Humidity

akku-drive HiClass electronic control for titration and dispensing excellent precision, comfort, flexibility

Professional Station Software Suite

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

DC Electronic Loads 8500 series

FOR MORE INFORMATION or from a non-telstra phone and say pre-paid telstra.com/ppmbb visit a telstra store or partner

Epidural Management. Policy/Purpose. Scope

4-Channel Thermometer / Datalogger

Service Manual for BodyGuard 323, 545, & 575 Infusion pumps

GSM Autodialer Professional GJD700 Speech & Text Autodialer

MITEL 5330 IP Phone User Guide. Northwestern Michigan College

Use of the Injectable Medicines Guide website in clinical areas - IntraVENOUS medicine monographs (January 2013)

Designed with you in mind.

Series 90 Series 90HV

Routefinder Testing and reporting for emergency lighting systems

AC-115 Compact Networked Single Door Controller. Installation and User Manual

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Rapid Response Report NPSA/2010/RRR013: Safer administration of insulin

SMS GSM Alarm Messenger

3U 4V 4A L1 L2 L3 V2 = 314 V3 = -84 N = -14 > ensuring high performance C.A 8332B C.A 8334B C.A 8335 POWER AND ENERGY QUALITY ANALYSERS

Maintenance Station Software Suite

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

Smart Anytime, Safe Anywhere. Climax Home Portal Platform. Envisage and Enable a Connected Future

Promoting safer use of injectable medicines

Operator Station Software Suite

JORVET INFUSION PUMP J1060M OPERATOR MANUAL

Electric Measurement and Control. Energy management software

Guideline for the use of subcutaneous hydration in palliative care (hypodermoclysis)

Installation, Service, Repair and Training for Custodial Locks, Doors, Furniture & High Security Locking. The global leader in door opening solutions

ADDING and/or DELETING PIN NUMBERS (Plus other simple programming commands) in My DK-16 or DK-26 DIGITAL KEYPAD

9 Control Equipment. Control Button Series 8082

Keypad Programming Instructions for the Profile Series LK and v.g1 Locks

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

BUSINESS COMMUNICATIONS DIVISION. IP4100 SIP DECT User Guide

Why NetDimensions Learning

WHOLESALE DIRECT INC WEST 65TH STREET

Transcription:

A small, safe, reliable and user-friendly device suitable for inpatient and outpatient use in a variety of applications

The T 34 Ambulatory Syringe Pump is accurate, reliable, user-friendly and meets all of the NPSA requirements for Safer Ambulatory Syringe Drivers (RRR019) Applications Medications/analgesics Palliative care Brittle Asthma Chemotherapy General fluid replacement Intended use Intravenous Subcutaneous Percutaneous Epidural (in close proximity to nerves) Intra-operative site Intra-arterial When you need an accurate and reliable system which is configurable to a range of applications Automatic calculation of syringe volume and depending on mode of operation, can deliver contents over a specified duration or as ml/hour Lockable ml/hour setting (rate setting) suitable for homecare use The Post Occlusion Bolus Reduction System will safely equalise pressure in the line, following an occlusion, without administering a potential post-occlusion bolus Configurable occlusion pressures for different clinical applications and therapies Four configurable modes of operation available to suit specific applications: o Lock on o Lock off o Rate mode o Rate setting 2

When you need a safety enhanced system which meets all of the NPSA requirements Three-point automatic syringe detection and recognition system allows you to quickly and easily set up the pump and will detect most commonly used syringe brands The built-in event log automatically records date and time-stamped key presses, alarms and errors A lockable keypad prevents most inadvertent key presses Code-protected functions only allow authorised personnel to change settings Automatic alarms will draw immediate attention to any pump status requiring intervention Administer small volumes with high levels of accuracy Latex-free, dedicated administration lines with very small priming volumes, anti-siphon valves and anti-kink tubing are available When you need a system which is quick and easy to use, allowing you more time for your patients Set up instructions are on a label on the front of the pump During operation, pump displays time remaining, flow rate and a pump operating indication Info key displays volume infused, volume to be infused and battery level to allow quick and easy checks The digital descriptive display guides you step-by-step throughout the use of the pump When you need a pump that s flexible enough to use on the move and with a range of patients Suitable for both bedside and ambulatory use Powered by 1 x 9V disposable battery (recommended rechargeable batteries can also be used) Can be used with most common syringe brands and sizes (up to 50ml) Suitable for adult and paediatric use When you need a pump which offers your patients a host of benefits Your patient will have complete freedom to ambulate during infusion carry pouches are available for easy transportation Intuitive operation and display features will help your patient to understand their medication and to make basic operational changes Homecare patients will benefit from quick and easy set up functionality The small and discreet design will give your patient dignity Built-in safety features will instil confidence in your patient, knowing they are receiving a high level of care 3

Supporting information If you are formulating a Purchasing for Safety Initiative for Safer Ambulatory Syringe Drivers, the information below will help you to see how the T34 Ambulatory Syringe Pump can help you to meet and exceed the NPSA requirements for risk reduction (NPSA/2010/RRR019). PURCHASING FOR SAFETY INITIATIVE CHECKLIST Required Safety feature Rate settings in millilitres (ml) per hour Mechanisms to stop infusion if the syringe is not properly or securely fitted Alarms that activate if the syringe is removed before the infusion is stopped Lockbox covers and/or lock out controlled by password Provision of internal log memory to record all pump events T34 feature Automatic calculation of infusion rate and volume in ml/hour Three-point syringe detection system Immediate syringe displacement alarm which will halt infusion until resolved Dedicated key-operated lockboxes available plus code-protected programmes locked into the pump and a lockable keypad The last 512 sequential events are recorded in the pump event log and can be downloaded to a PC using our own configuration software, BodyComm DURING TRANSITION You can depend on a collaborative approach from us to ensure a safe and successful implementation of your new T34 Ambulatory Syringe Pump Our clinical specialists will assess your training needs and design and implement a training programme that is specific to your needs, fit for purpose and achieves your training objectives DURING INFUSION Automatic infusion rate calculation in ml/hour eliminates the need for manual measurement or rate calculation Dedicated key-operated lockboxes are available to protect the pump, syringe and contents from damage or tampering A comprehensive range of user manuals and RCN-accredited training materials are provided to ensure accurate and safe use of the device 4

Pump and accessories Product code SBOMT34A Description T34 Syringe Pump and User Manual SBOMT34DOCKB T34 Docking Station Mains PSU, including RS232 Lead SBOMT34DOCKC T34 Docking Station 2x9V including RS232 Lead SBOMT34EA T34 Syringe Pump Extended Memory and User Manual SBOMT34LOC SBOMT34LOCYEL Lockbox (clear) including 2 keys Lockbox (yellow tint) including 2 keys 198-201 Carry pouch for pump and lockbox (single patient use) 100-176s Carry pouch for pump and lockbox (reusable) 100-177S Carry pouch for pump only (reusable) Parts included 100-100SM 100-090PLANET Parts description T34 Syringe Pump T34 User Manual 150-312S T34 Docking Station 150-311CPC 150-312CPC RS232 Lead T34 Docking Station Power Supply (12V) 150-755X T34 Docking Station AC Mains Adapter (2x9V) BCS88 BodyComm 88 Software 150-312S T34 Docking Station 130-050X2 T34 Docking Station Battery Adapter (2x9V) 150-311CPC BCS88 100-200PSM 100-090PLANET 100-174SA RS232 Lead BodyComm 88 Software T34 Syringe Pump with Extended Memory T34 User Manual T34 Lockbox (clear) 170-002X Lockbox key x 2 100-174SE T34 Lockbox (yellow tint) 170-002X Lockbox key x 2 Administration sets Product code Colour Pump connection Patient connection Length Prime volume Free flow safety 100-172S Clear Female luer lock Male luer lock 100cm 0.5ml Anti-siphon valve 100-170S Clear Female luer lock 25g butterfly needle 100cm 0.5ml Anti-siphon valve 100-172SB Blue Female luer lock Male luer lock 200cm 0.7ml Anti-siphon valve & clamp 100-172SE Yellow Female luer lock Male luer lock 100cm 0.5ml Anti-siphon valve 100-172SC Blue Female luer lock Male luer lock 170cm 1.0ml Anti-siphon valve, Y connector & clamp 5

CME Support by your side throughout Technical support Your technical support needs are our priority. As an ISO 13485 certified support facility, we can offer you high-quality technical support and training, with services developed by our customers for our customers. You and your team will benefit from market-leading technical training and support services. We will work with you to ensure you receive the best possible service package for your needs. TRAINING Your role as Biomedical Engineer in supporting and maintaining these sophisticated devices is a very important one. That is why we offer a range of technical training courses and materials which are designed to give you the knowledge and skills to expertly support your chosen devices. EQUIPMENT REPAIR AND SERVICING Our team of highly skilled engineers will support you by ensuring competitive turnaround times. Prompt spare parts order fulfilment is guaranteed by our significant stockholding capability. SERVICE CONTRACTS When entering into a service contract with CME Medical, a partnership is formed to ensure your requirements are identified and addressed from the outset. Clinical support You and your team need the confidence to competently and safely operate your chosen infusion devices. That is why we have developed a range of education programmes which are based on current and well-established principles of learning and training strategies and which follow national standards for medical device training. Your competency-based training can be delivered either face to face or via e-learning. We can offer both at the point of purchase and periodically as required. Your dedicated Clinical Support Specialist will work with you to develop a training plan which is tailored to your local needs, fit for purpose and which will help you to achieve your training objectives. Emphasis will be placed on intensive training for your advanced users, allowing you to take control of your own cascade training as your organisation goes forward. 6

BodyComm BodyComm is an easy-to-use configuration software programme which enables efficient and flexible management of all infusion protocols stored in your T34 Ambulatory Syringe Pump. Use BodyComm to: Download, save and print a record of the last 512 sequential stored events, including alarms, from your pump event log for display in text and graphic format Data captured for each event Date & time Volume infused Event number Time (duration) Length of travel (mm versus ml) Rate Volume to be infused Position of the actuator Syringe type and size Alarm mmhg Battery voltage level Technical specifications Type Flow rate Accuracy Syringe sizes Battery Battery operation Alarms Dimensions Weight Syringe pump with motor-driven linear actuator 0.05ml 10ml/hr in 0.01ml increments, 10 650ml/hr in 1ml increments (up to 1,000ml/hr available) +/- 5% system accuracy Accommodates most syringe brands from 2ml to 50ml 9V alkaline, IEC 6LR61 type Approximately seven full infusions The T34 will alarm for the following problems: Occlusion or syringe empty Pump paused too long End programme End battery Syringe displaced Syringe empty 169 x 53 x 23mm 210g without battery, 274g with battery 7

Our complete range of specialist infusion devices For more information, please contact us using the details below. Head Office Kincraig Business Park Kincraig Road Blackpool FY2 0PJ Fax: 01253 896648 Southern Office Milton Park Innovation Centre Office 217, 99 Milton Park Abingdon OX14 4RY Fax: 08704416093 Central Switchboard: email: info@cmemedical.co.uk 01253 894646 www.cmemedical.co.uk MKGT34GEN12