FACT OPTICAL DISTRIBUTION FRAME SYSTEM



Similar documents
Reliable, Consistent, Quality

FCS-FCT-FCP Housings and Connector Panels. InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2

LANC Fibre Patch Panel Solution

1U Multi-Function Fibre Enclosure

InstaPATCH ZERO Solution Guide

Cabinets 101: Configuring A Network Or Server Cabinet

FiberGuide Fiber Management Systems. 4th Edition

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

FTTX Solutions FDH 3000 Cross-Connect

ETD Fiber Optic Products

Panduit 28 AWG Patch Cords Installation Guideline

E Series. E Series. Category 6 and 5e. Features

Faster Method for Connecting Customers in the Colocation Data Center

HP 16/18-Port Cable Management Kit Installation Guide

7.4 3M No Polish Connector

Plug - Type (Male/Female) Attenuators CAA series Singlemode

Cable Assembly Solutions at the Speed of Light

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

Cabinet V800 V800 CABINETS

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

Plug & Play Universal Systems

Uniprise Solutions. Information Security Network Solutions

Pretium EDGE HD Solutions

Wall Mounted Products

Opticom Fiber Optic Splice Module

FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future

About the BitStorm 6051 POTS Splitter

Pretium Connector Housings

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

Polymer Coated Fiber Cable (PCF)

Coyote popup features

Coyote popup features

SECURE Fiber Optic Products

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

Tubing and Accessories

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

Also available OM4. Other specification available on request Approved for Telecom quality standards. Cable colour. Lenght (m) Fiber type.

Coyote popup features

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

Product Information 19 / 45HU Data-Center-Rack (Cabinet)

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007

LED NarrowStik LED LC-Stik

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

TCTC Cabling Specifications

4RU High Density Shelf Installation Instructions

MPO. Fast Fibre Solution for Data Centres

DIY Y6. Build Manual V.A 2014

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

INSTALLATION GUIDE. APPLICATION LENGTH MODEL YR PART # Bestop PART #

Fiber-to-the-Home/FTTH

Patch Cords for Data Center Applications

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Procedure for Cutting and Respooling Fiber Optic Cable

InForm Mobile Units. Selection. Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley

FIBRA OPTICA INTERIOR/EXTERIOR TIGHT BUFFER

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

INSTALLATION INSTRUCTIONS

HARTING Ethernet Cabling 8-poles Overview

DCF Optimized Rack System Selection Guide

Mazda CX

ADC-APC Integrated Cisco Data Center Solutions

2178-S Fiber Optic Splice Case

DIGITUS Network & Server Cabinets. UNIQUE Series

FIBER OPTIC CABLE PLANT DOCUMENTATION

Heating oven with mechanical convection

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Rack Systems Solutions

DATA CENTRES POWERED BY EXCEL

Concepts. Products. Service. Lindner Plus Organisation

Time needed: ~3h for lid replacement only. Add 1h for operation harness in lid and ~2h more for installing drive unit and cable harness in trunk.

Using a Fabric Extender with a Cisco Nexus 5000 Series Switch

Digital Link Cross Connect (DLx ) System User Manual

Data Centre Solutions

Knürr Smaract. Knürr Smaract. CompactRack

ONTRAC WIRE MESH CABLE TRAY SYSTEM

ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER

CNC Tool Storage Solutions

ASKING FOR ASSISTANCE

GENUINE PARTS INSTALLATION INSTRUCTIONS

InstaPATCH Cu Cabling Solutions for Data Centers

RACK ENCLOSURES & ACCESSORIES

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

4 Small Cables Sealing Kit: Wrap Style

How To Build A T7 Rack For Information Technology

Belden. Optical Fiber Catalog. One Enterprise. One Infrastructure. One Partner. Belden IBDN FiberExpress Systems

TIER-1/TIER-2 FIBER CERTIFICATION KITS

Coat Racks Floor Racks Hooks Hangers Hook Panels Wardrobes

BUILDING INSTRUCTIONS

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

19" Open Rack for Network and Cabling Management

Developing the Green Data Center

SFP Transceiver Specifications

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

Knürr DCM. Knürr DCM. 19 Server Rack System 19 Heavy Duty Rack 1.2 to

Next Generation Frame System

How To Make A Fibre Cable For A Data Centre

Transcription:

Fiber Connectivity for Splice/Patch and Patch/Patch For almost 30 years, CommScope has led the industry with solutions such as FIST fiber management system, providing a system of fiber management from the central office through the customer premises. Now, we continue that leadership with the introduction of the FACT ODF system, enabling faster and easier installation in a high density environment. The toolless system approach and the high level of modularity guarantee an easy migration path towards new connectivity platforms and expansion of existing central office sites. FACT modules support full patch and/or splice-patch functions within a rack environment. Trays within the element can be configured with adapters, splicing and passive optical components. Trays are staggered for easy fiber routing and access to connectors.currently available, the FACT standard version integrates into a current partially or non-equipped FIST-GR2/3 frame or lineup. Features Patching, using patch cords, connectorized breakout or intrafacility cables Splicing loose tube, non-connectorized intrafacility or breakout cables to pigtails and patching these pigtails to patch cords Supports integration of passive optical splitters and wavelength division multiplexers Various connector/adapter types possible Enhanced modularity created by stacking four elements together in a 3HU grouping Full patching capability on the elements and between elements in one module and across modules Use of connectorized cables allows repair of pigtails Easy identification of each fiber Kits available to attach cables at the side of the elements Full wrap-around solution accessible from the front to guide fibers and pigtail Can be installed in FIST racks and metric (ETSI) rack sizes FACT elements and modules are shipped with the maximum number of trays already installed. 1

Benefits of advanced element patching Easy: Full front access and non-moving fiber during element manipulation Fast: Toolless scalable system Clean: Both sides easily accessible for cleaning adapters Safe: Laser light oriented perpendicularly to the operator Accessible: Guaranteed full front access at both sides of connection Secure: Because of their position in the trays, connectors are better protected than in some front facing patch shelves Manipulation of patch cords does not cause transient losses Reconnection to other positions in the same tray or shelf does not result in uncontrolled overlengths Bend controls guide and protect the pigtail cable and ensure controlled cable routing Visible: Patch cords do not hamper access or visibility of ports Dimensions of FACT elements Height in mm Width in mm Depth in mm Number of standard/ small-form-factor adapters Standard (retrofit in FIST-GR3 frames) 30.95 524 283.1 24/48 Ordering FACT modules Element colors: Orange (RAL 2011) and grey (RAL 7035) Elements are always ordered fully loaded For a list of accessories and consumables, please refer to the FACT accessories ordering guide Elements are configured with single adapters* Cable construction (the number of fibers per cable) will determine the number and combination of elements to be ordered Depending on the cable s fiber count, at least one of the total number required to support that number of fibers must be releasable (equipped with a latch that allows a set/combination of elements to be removed from the rack) Elements support most common cable constructions (loose tube, central core, IFC) Four (4) elements equal 3HU (125mm) * For FACT elements with adapter packs, please contact your local sales representative. 2

Cable fiber count SC connectors/adapters LC connectors/adapters 24 SC connectors per element (1) 48 LC connectors per element (2) Number of FCEs Height Units Number of FCEs Height Units 24 1 Fits 1HU 1* Fits 1HU 48 2 Fits 2HU 1 Fits 1HU 72 3 Fits 3HU 2** Fits 2HU 96 4 Fits 3HU 2 Fits 2HU 144 6 Fits 5HU 3 Fits 3HU 192 8 Fits 6HU 4 Fits 3HU 288 - - 6 Fits 5HU 1 SC connectors with up to 2.4mm patch cords 2 LC connectors with up to 1.8mm patch cords * Element ships with 2 trays, each with 12 LC adapters (24 LC connections); 48 LC connections in total. Unused tray may be discarded or used for future growth. ** Each elements ship with 2 trays, each with 12 LC adapters (24 LC connections). 96 LC connections in total. Unused trays may be discarded or used for future growth. 3

FACT STANDARD SIZE Ordered for retrofit into a current partially or non-equipped FIST-GR2/3 frame or lineup. 4

FACT Module - Standard Size Patch only. No Cable. Standard kit includes: Trumpets Hook and loop fasteners Back plates ordered separately. Size of back plate defined by port/fiber count. See page 8 for information. FACT - S -XXX XX AA - 0 NN Port count 024 24-position (SC only) 048 48-position 072 72-position (SC only) 096 96-position 144 144-position 192 192-position 288 288-position (LC only) Adaptor type Single adapters S1 SC/UPC S2 SC/APC 8 L1 LC/UPC L2 LC/APC E9 E2000 8 For FACT elements with adapter packs, please contact your local sales representative. 5

FACT Module - Standard Size Splice/Patch. No Cable. Standard kit includes: Trumpets Hook and loop fasteners Back plates ordered separately. Size of back plate defined by port/fiber count. See page 8 for information. Cable attachment kits ordered separately. Attachment size defined by cable size and fiber type. See pages 9 and 10 for information. Port count FACT - S -XXX XX XX - 0 NN Tray Option 024 24-position (SC only) 048 48-position 072 72-position (SC only) 096 96-position 144 144-position 192 192-position 288 288-position (LC only) Adapter type Single adapters Standard (Grade C) Superior (Grade B) SC/UPC S1 - SC/APC 8 S2 SG SC/APC 9 S3 - LC/UPC L1 LF LC/APC L2 LG E2000 8 E9 - For FACT elements with adapter packs, please contact your local sales representative. Standard adapters Right of shelf (1) Left of shelf (2) Adapters; SMOUV splice protector; no fiber (3) AE EA Adapters; ANT splice holder (4) ; no fiber AF FA Connector/adapters; with pigtails and SMOUV splice protector (3) ; fiber from adapters to splice holder, ready for incoming cable Connector/adapters; with pigtails and ANT splice holder (4) ; fiber from adapters to splice holder, ready for incoming cable 1 Patch cords leave shelf to right 2 Patch cords leave shelf to left 3 45 mm SMOUV heat shrink splice protector is included 4 ANT splice holder ONLY; splice protectors must be ordered separately NOTE: Pigtails are installed with DIN IEC 60304 color coding. DIN IEC 60304 Fiber 1 Red Fiber 7 Brown Fiber 2 Green Fiber 8 Violet Fiber 3 Blue Fiber 9 Aqua Fiber 4 Yellow Fiber 10 Black Fiber 5 White Fiber 11 Orange Fiber 6 Grey Fiber 12 Pink AI AJ IA JA If you want a different color coding, please contact your local sales representative. 6

FACT Module - Standard Size Splice/Patch. Pre-cabled. Standard kit includes: Trumpets (pre-installed) Cable attachments (pre-installed) Hook and loop fasteners Back plates ordered separately. Size of back plate defined by port/fiber count. See page 8 for information. Port count 024 24-position 048 48-position 072 72-position 096 96-position 144 144-position 192 192-position 288 288-position (LC only) Adapter type Single adapters Standard (Grade C) Superior (Grade B) SC/UPC S1 - SC/APC 8 S2 SG SC/APC 9 S3 - FACT - S -XXX XX XX - XX XX Length in meters 0-99 Tray Option 1A MA MB OD OF OG OH Intrafacility cable 12-fiber (no strength member) Micro-distribution breakout cable 8-fiber 12-fiber Loose tube indoor cable 24-fiber 48-fiber 72-fiber 96-fiber For other cable types, please contact your sales representative. LC/UPC L1 LF LC/APC L2 LG E2000 8 E9 - For FACT elements with adapter packs, please contact your local sales representative. Standard adapters Right of shelf (1) Left of shelf (2) Adapters; SMOUV splice protector; no fiber (3) AE EA Adapters; ANT splice holder (4) ; no fiber AF FA NOTE: Pigtails are installed with DIN IEC 60304 color coding. 1 Patch cords leave shelf to right 2 Patch cords leave shelf to left 3 45 mm SMOUV heat shrink splice protector is included 4 ANT splice holder ONLY; splice protectors must be ordered separately DIN IEC 60304 Fiber 1 Red Fiber 5 White Fiber 9 Aqua Fiber 2 Green Fiber 6 Grey Fiber 10 Black Fiber 3 Blue Fiber 7 Brown Fiber 11 Orange Fiber 4 Yellow Fiber 8 Violet Fiber 12 Pink If you want a different color coding, please contact your local sales representative. 7

Back plates for standard size FACT elements and modules Description Ordering Number Back plates Allow placement of FACT STANDARD size elements or modules in FIST-GR3 Fits 1 HU; mounts 1 standard size FACT element (2) cage nuts (2) bolts (2) washers (2) single U-shape FACT brackets FACT-BPLATE-1E-S Fits 2 HU; mounts 2 standard size FACT elements (4) cage nuts (4) bolts (4) washers (2) double U-shape FACT brackets Equal to 3 HU; mounts 4 standard size FACT elements (1 FACT module) (4) cage nuts (4) bolts (4) washers (4) double U-shape FACT brackets FACT-BPLATE-2E-S FACT-BPLATE-4E-S NOTE: When an empty FIST-GR3 rack is to be fully loaded with FACT elements, a kit (FACT-BPLATE-28E-S) is available. This one piece plate accommodates 28 FCE and occupies one half of the FIST-GR3 (2.2m) rack. Please contact your local sales representative for more information. Cable fiber count SC connectors/adapters 24 SC connectors per element LC connectors/adapters 48 LC connectors per element Number of FCEs Height Units Number of back plates Number of FCEs Height Units Number of back plates 24 1 Fits 1HU (1) 1E-S 1 Fits 1HU (1) 1E-S 48 2 Fits 2HU (1) 2E-S 1 Fits 1HU (1) 1E-S 72 3 Fits 3HU (1) 1E-S + (1) 2E-S 2 Fits 2HU (1) 2E-S 96 4 Fits 3HU (1) 4E-S 2 Fits 2HU (1) 2E-S 144 6 Fits 5HU (1) 2E-S + (1) 4E-S 3 Fits 3HU (1) 1E-S + (1) 2E-S 192 8 Fits 6HU (2) 4E-S 4 Fits 3HU (1) 4E-S 288 - - - 6 Fits 5HU (1) 2E-S (1) 4E-S 8

Cable attachment kits for standard size FACT elements and modules Description Ordering Number Cable bracket kits 250 μ cable For cable diameters up to 8.5mm* Occupies 1 FACT element Single cable attachment sub-assemblies Strength members 250 μ routing components Plastic covers 250 μ overtubing Overtubing fixation devices Spiral tube protection pieces Tie wraps Foam strips FACT-CACC-SMALL-PF For cable diameters from 8.5mm to 15mm** Occupies 1 FACT element Single cable attachment sub-assembly Strength member 250 μ routing components Plastic cover 250 μ overtubing Spiral tube protection pieces Tie wraps Foam strips FACT-CACC-MEDIUM-PF Cable bracket kits 900 μ cable For cable diameters up to 8.5mm* Occupies 1 FACT element Single cable attachment sub-assemblies Strength members 900 μ routing components Plastic covers Fiber fixation devices Spiral tube protection pieces Tie wraps Foam strips FACT-CACC-SMALL-SF For cable diameters from 8.5mm to 15mm** Occupies 1 FACT element Single cable attachment sub-assemblies Strength members 900 μ routing components Plastic covers Fiber fixation devices Spiral tube protection pieces Tie wraps Foam strips FACT-CACC-MEDIUM-SF * Note: Cable should be flexible and allow minimum bend radius of 75 mm. Cable attachment fits corrugated tube 10mm outer diameter ** Note: Cable should be flexible and allow minimum bend radius of 75 mm. Cable attachment fits corrugated tube 16mm outer diameter 9

Cable fiber count Number of FCEs SC connectors/adapters 24 SC connectors per element Height Units Number of cable attachment kits Number of FCEs LC connectors/adapters 48 LC connectors per element Height Units Number of cable attachment kits SMALL MEDIUM SMALL MEDIUM 24 1 Fits 1HU 1 1 - - - - 48 2 Fits 2HU 2 2 1 Fits 1HU 1 1 72 3 Fits 3HU 3 3 2 Fits 2HU 2 2 96 4 Fits 3HU 4 4 2 Fits 2HU 2 2 144 6 Fits 5HU 6 6 3 Fits 3HU 3 3 192 8 Fits 6HU 8 8 4 Fits 3HU 4 4 288 - - - - 6 Fits 5HU 6 6 www.commscope.com Visit our website or contact your local CommScope representative for more information. 2015 CommScope, Inc. All rights reserved. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. PS-319161.4 (10/15)