Operating Instructions



Similar documents
HF/RF Electrosurgery Unit SMT ESU 60 M (MONO) Operating Manual

BM CLINIC 170 W, GYN/SURG 125 W, DERM 100 W

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

USER MANUAL EN IN 7449 Power Tower insportline Power Tower PT500

HF / RF Electrosurgical Units SMT BM M PF and SMT BM M PF P

SunMor SM-V30 Solar Water Heater Installation Manual

Operating Instructions Drill rig DRU160

Dissolved Oxygen Sensors

Contraindications: Malign or benign strictures in the upper part of esophagus close to the cricopharyngeal muscle.

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

TIG torches to 3-5 Tungsten electrodes to 3-7 TIG consumables Miscellaneous

804 Ti Stand. Manual EN

Piping Systems for Nuclear Power Industry. Prague, October 2011

Thermostatic Actuators

OPERATION MANUAL SAFETY PRINCIPLES, OPERATION AND MAINTENANCE FOR BRICKLAYER S PULLEY

When Safety Comes First. Emergency Safety Shower and Eye Wash Catalogue

Operating instructions Supply system for flammable liquids. Labor

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

The Bose 601 TM Series IV Direct/Reflecting Speaker System

INSTRUCTIONS FOR USE SAFETY PRINCIPLES, OPERATION AND MAINTENANCE FOR. HYDRAULIC PUMP type HP 03L, 05L, 07L volume 3 l, 5 l, 7 l

When Safety Comes First. Emergency Safety Shower and Eye Wash Catalogue

Morini CM 22M. Technical Data

Itho Products for Hot and Boiling water. product-

WIKA INSTRUMENT CORPORATION

Machine Documentation

Brewing technique for the professional brewer!

Stove Guard Kit User Manual

SAFETY & OPERATING INSTRUCTIONS

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

How To Test A Titrette And Digital Burette

THE NEWCASTLE UPON TYNE HOSPITALS NHS FOUNDATION TRUST SAFE USE AND STORAGE OF LIQUID NITROGEN AND SOLID CARBON DIOXIDE (DRY ICE)

VACUUM CLEANER INSTRUCTION MANUAL

AIR-SUSPENSION. Art. nr.: L.L C.M. Auxiliary Air Suspension. Designed for: Mitsubishi L200. From: 2007& UP RDW 71/

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

TIG INVERTER INSTRUCTION MANUAL

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Extrusion Flo-Valve INSTRUCTIONS-PARTS LIST psi (210 bar) Maximum Working Pressure. Model , Series K. Rev.

LNG Fuel Tank System LNG Tank overview

Infrarot-Bewegungsmelder IP44

Operating instructions for Electrode sharpening machine WIG 4

ALI BABA PIANTANA (H165) design SLIDE Studio

PNEUMATIC - HIGH PRESSURE FLAT-FORM HEAVY LIFTING BAGS

OPERATING INSTRUCTIONS FOR ELECTRODE SHARPENING MACHINE WIG 4

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Guide to Gate Safety Legislation & the Machinery Directive. In Association with:

DOCUMENTATION FOR QUALIFICATION SYSTEM

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

IMPORTANT SAFETY NOTICE

CUBO 20 HANGING design SLIDE Studio

Ireland Australia New Zealand

SP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE)

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

SD. Flat roof. Rack Mounting. Installation instructions (2010/11) AU

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

BINKS MODEL 460 LIGHTWEIGHT AUTOMATIC SPRAY GUN

TV Ears 5.0 Digital & Dual Digital Quick Start Guide

Instructions for Use. Components of the GENOTROPIN PEN 12

PIVOT GLOBO design SLIDE Studio

VELA Samba 400/410/500/510/520/530 USER MANUAL VARIANT: Manual no VELA Samba 530. VELA Samba 510. VELA Samba 520.

TBi Industries. MIG / MAG Welding torches TBi Expert 0. 1

Hot water supply, distribution and use

FF30. Flexicon. Operator s Manual. FF30-F In-feed Rotary Table. OPERATOR S MANUAL Serial Number yyww xxxx. Filling and Capping System

1/2 GLOBO 40 design SLIDE Studio

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

REPAIR AND MAINTENANCE MANUAL

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

SAFETY PRINCIPLES, OPERATION AND MAINTENANCE MANUAL FOR HYDRAULIC JACK

BROEN UNiFlEx FiTTiNgs FOR BURNiNg gases OEN OEN ifl ifl FOR FOR BURN BURN gas gas

Workshop Compressors CLASSIC Series

Vacuum Hair Clipper. 10,000 prize draw. Register online for HC6550. EXTRA year guarantee FREE rewards gallery

All technical modifications reserved. 09/08. TSC

Please calculate with around 5% more square meters than needed because you will have material loss due to cutting and sorting.

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Toroidal Conductivity Sensor

SunMaxx Solar Filling Station Operating Instructions

GLOBO 30 design SLIDE Studio

Fitting Instruction: Daytona 675 Street Triple from VIN , Street Triple R from VIN A

GLOBO 30 design SLIDE Studio

SR 801. DK... Digitalvægt... 2 GB... Digital Scale... 7 D... Digitalwaage S... Digitalvåg U.S.A. and countries outside the EU...

HEAVY-DUTY HAND CUTTING TORCHES AND ACCESSORIES. Page 1 Version no.: V

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

1.6 Spider naevi These are skin blood vessels which have become enlarged to form spidery red blobs in the skin. They can be cauterised away.

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Operators manual Basic water heater

Brushless Motors Instructions

Test Report No. C829QPEN

API Flanged Safety Relief Valves Series 526 CATALOG

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

HAIR CLIPPER. Model No. HC5150 HC

ICH Topic Q4B Annex 5 Disintegration Test General Chapter. Step 3

MINIFOK MACHINES MINI FIBER OPTIC CABLE BLOWING MACHINE. fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES

CYBEX GmbH Riedinger Str Bayreuth Germany.

Microwave Meter. Instruction Manual

RISK ASSESMENT: HANDLING, TRANSPORTATION AND STORAGE OF LIQUID NITROGEN AND OTHER CRYOGENIC MATERIAL

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Specific volume and absorption properties

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Assembly and instructions

Transcription:

Special Medical Technology, Ltd. CRYOSPRAY CS 1 E 1014 Operating Instructions Special Medical Technology

Special Medical Technology, Ltd. Content: 1. CAUTION...4 2. INTRODUCTION...5 3. HOW TO OPERATE WITH THE CRYOSPRAY CS 1E...5 4. THE SIMPLIFIED CRYOSURGICAL TECHNIQUE...6 5. TECHNICAL PARAMETERS...7 6. MAIN PARTS OF THE CRYOSPRAY CS 1E...7 3 CRYOSPRAY CS 1E

Special Medical Technology, Ltd. Manufacturer: Special Medical Technology, Co. Ltd. Papírenská 114/5 160 00 Prague 6 Czech Republic, EUROPEAN UNION - EU Phone: +420 233 320 201, Fax: +420 224 318 011 E-mail: smt-praha@smt-praha.com, obchod@smt-praha.com Internet: www.smt-praha.com Device classification class:... II a Device service life:... 7 years 1. CAUTION Study cryosurgical principles before operation! Incline the FULL cryospray during operation or manipulation up to angle 45-60 maximally! Use only medical LIQUID NITROGEN with temperature -196 C as a coolant! CRYOSPRAY CS 1E 4

Special Medical Technology, Ltd. 2. INTRODUCTION A cryogenic injury of tissue is the most natural local destructive modality. The treatment and cure of benign skin tumours efficiency by liquid nitrogen is very high. Cryosurgical devices for liquid nitrogen allow the most rapid heat extraction from the tissue - no other coolant is so effective! The CRYOSPRAY method - CRYOSPRAYING - is the simplest and cheapest cryosurgical method. The CRYOSPRAY method is suitable mainly for the treatment of smaller benign skin tumours. The basic areas for utilisation of the CRYOSPRAY s method are: DERMATOLOGY SURGERY, PROCTOLOGY (haemorrhoids) OPHTHALMOLOGY OTORHINOLARYNGOLOGY UROLOGY and GYNECOLOGY for benign surfice leasons, as Condyloma Accuminata and usual warts Caution: For larger benign and for malignant tumours is necessary to use computerized contact up-to-date cryosurgical system KCH 450 with the rewarming up equipment - take advice of the producer! 3. HOW TO OPERATE WITH THE CRYOSPRAY CS 1E 1. Unscrew the black plastic head /1/ of the device (see page 8) 2. Fill the device with the coolant - liquid nitrogen - up to 7 cm from the upper end of the thermos vessel /2/ approximately 3. Screw the black plastic head /1/ and tighten carefully 4. Install the operating Jet J 6 (and/or a contact tip-see specification) and screw it into the nozzle of the cryospray /4/. 5. Take the Cryospray by right or left hand and push the trigger /3/ while the operating jet /6/ (or contact tip) is near of the right operating possition a few milimeters from targeted area - the affection (pathological tissue) of the patient. Decline the Apparatus 90 to the left or right for 1 second only. By this the required op- 5 CRYOSPRAY CS 1E

Special Medical Technology, Ltd. erating pressure is created. Do not release the trigger!! The liquid nitrogen will start to jet out of the spray tip on the tissue. Control the direction of the nitrogen. Still keep the trigger pushed! By releasing of the trigger when the operation is ready you will stop spraying. In the device is zero pressure again. The working presure is there only during the treatment! This is the great advantage and the best safety feature of this Cryospray. The Device CS 1E standing on the Dermathologist s table is without any pressure! 6. Usuall spray freezing by the Jet J6 is from the distance of a few milimeters for 5-30 seconds. When the frozen area is visible (white) the spraying operation is over! You have to release the trigger to stop the operation. If you use the contact tip you have to wait when the tissue is rewarmed up and to remove the instrument from the tissue carefully, without any force. The best direction of the spraying is tangent one to the finger /body/ of the patient. Use this direction always when possible. 7. After operation treat the affection by usual sterile cover and invite the patient to control in the comming days. 4. THE SIMPLIFIED CRYOSURGICAL TECHNIQUE CRYOSPRAYING BY THE CRYOSPRAY CS 1E HAS THESE MAIN FEATURES: one hand operation - leave one hand free to manipulate lession or adjacent skin instant pressure - the pressure is built-up in one second if you push the trigger and decline the device - for 1 second only easily portable - light-weight wide fill opening - easy filling with the coolant (liquid nitrogen) thanks to the broad filling neck all stainless steel thermos - safe, no rust, no risk of glass implosion no valve system - any control unnecessary, no pressure if not working high safety vacuum insulation - very effective time saving, quick, economical, safe, simple CRYOSPRAY CS 1E 6

Special Medical Technology, Ltd. for whole-day work - filling with the coolant (liquid nitrogen) is usually necessary once a day only possibility to locate a stream of nitrogen into very small area of the tissue - by precise jet (only necessary destructed tissue) new repumping apparatus PIPE 1 - for the quick and comfortable filling of the Cryospray (special accessory) line of other spray tips available (additional accessories) soft contact oper. tips O2 or OC 2 - (special additional accessories) - useful for ophthalmology - for eyelids, above all series of other contact tips available (special additional accessories). 5. TECHNICAL PARAMETERS Coolant:... liquid nitrogen ( - 196 C) Capacity:...0,5 l Pressure:...max. 45 kpa Static holding time:...12 hours Diameter:...70 mm Height:...300 mm Insulation:...vacuum Weight without LN2:...400 g Weight with LN2:...750 g 6. THE FULFILMENT OF LEGISLATIVE REQUIREMENTS The conformity was reviewed with the product. The manufacturer declares at its own responsibility exclusively that the product fulfils basic requirements stated in Annex 1 of Regulations of the Czech Government No. 336/2004 Coll. (93/42/EEC) in the relevant valid readings. For the review were used these harmonised standards in a valid reading: EN ISO 13485 The examination of the conformity was carried out in participation of the Authoritative person Notified Body No. 1014. The Manufacturer issued a Declaration of Conformity on this matter. 7 CRYOSPRAY CS 1E

Special Medical Technology, Ltd. 7. MAIN PARTS OF THE CRYOSPRAY CS 1E 1 - Black plastic head 2 - Thermos 3 - Trigger 4 - Nozzle 5 - Valve 6 - Jet J6 CRYOSPRAY CS 1E 8

INDEMNITY AGREEMENT Type: Cryospray CS 1E Serial number: Date of sale: Stamp and signature of supervisor: Warranty conditions: 1. 24 months guarantee is given on the device when operated according to the Operating Manual, i. e. where there are possible defects in material or manufacture a replacement is made or the unit is repaired free of charge. 2. Manufacturer ensures that the device will have 24 months minimally the features given by its documentation - technical conditions and norms. 3. All repairs have to be realised by authorised service and/or by the manufacturer. 4. This certificate of Warranty is also the Certificate of Quality.

RECORDS OF REPAIRS Date of reception: Description of malfunction: Completion date: Date of reception: Description of malfunction: Signature and stamp of the service Completion date: Date of reception: Description of malfunction: Signature and stamp of the service Completion date: Signature and stamp of the service Date of reception: Description of malfunction: Completion date: Signature and stamp of the service Date of reception: Description of malfunction: Completion date: Signature and stamp of the service

END USER REGISTRATION CARD PRODUCT: CRYOSPRAY CS 1E Serial number: Sales clerk: User: Name: Organization: Address: Telephone: Fax: Herewith I confirm that I have got acquainted with the Operating Instructions and with the Guarantee Conditions and I will observe them. Date: Signature: Dear customers, will you tear this registration card out and forward it to the address: SMT Ltd., Papírenská 114/5, 160 00 Prague 6, Czech Republic, EU. The objective of this registration is, partly, to improve the quality of services our firm offers to its customers, and, partly, to observe strict requirements of standards ISO 13485:2003 that our firm conforms and that the user of medical technology must be acquainted with. In the next 3-9 months we will contact you again and will ask you for the filling of another our form (blank) - the Feed Back - which will be, thanks to your special opinions, a very good base for further development of our products. Thank you in advance for your kind cooperation. Yours, Special Medical Technology, Co.

Cryospray, modifications CS 1 and CS 1/3, CS 1E and CS 1/3ESpeciální Medicínská Technologie, s.r.o. Papírenská 5 160 00 Praha 6 Czech Republic Tel.: ++ 420 2 20 303 412 Fax: ++ 420 2 24 318 011 E-mail: obchod@smt-praha.com N 00154.01 wwwsmt-praha.com The last revision and issue of this Operating Instructions 05/07/2013.