Double Bone Plug Meniscus Reconstruction Surgical Technique



Similar documents
Stabilization of Acute Acromioclavicular Joint Dislocations using Dog Bone Button Technology Surgical Technique

Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL)

Technique Guide. VersiTomic. Michael A. Rauh, MD. Anterior Cruciate Ligament Reconstruction

Anteromedial ACL Reconstruction Surgical Technique for Soft Tissue Grafts

the revo / mini-revo shoulder fixation system s u r g i c a l t e c h n i q u e

Bankart Repair using the Smith & Nephew BIORAPTOR 2.9 Suture Anchor

FAST-FIX 360 Meniscal Repair System

Arthroscopic Shoulder Instability Repair Using the SUTUREFIX ULTRA Suture Anchor and SUTUREFIX ULTRA Instrumentation System

ACL Reconstruction with Bone-Tendon-Bone Transplants Using the ENDOBUTTON CL BTB Fixation System

Knotilus TM. Anchor Instability Repair. Technique Guide

Shoulder Restoration System

Comprehensive Solutions for Tendon and Ligament Reconstruction using the Bio-Tenodesis Screw System

Mini TightRope CMC Surgical Technique

Achilles Tendon Repair, Operative Technique

Titanium Wire with Barb and Needle. For canthal tendon procedures.

How To Fix A Radial Head Plate

Zimmer Periarticular Proximal Tibial Locking Plate

OptiLock Periarticular Plating System For Proximal Tibial Fractures. Pre-Launch Surgical Technique

Hip Arthroscopy Product Guide

How To Use A Phoenix Retrograde Femoral Nail

Portal Placement for Shoulder Arthroscopy: Basic to Advanced William B. Stetson, MD

ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

Spinal Arthrodesis Group Exercises

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

Minimally Invasive Hip Replacement through the Direct Lateral Approach

The Material Difference. Options for Rotator Cuff Repair, Labral Repair and Suture Management

Posterior Referencing. Surgical Technique

Labral Repair. Surgical Protocol by Ronald Glousman, M.D. and Nicholas Sgaglione, M.D.

V-TEK IVP System 2.7 System 4.0

All Suture Anchor. with IntelliBraid Technology

Hydrogel Competence in Eye Surgery

The rapid evolution of arthroscopic shoulder surgery

Versa-Fx II Femoral Fixation System Surgical Techniques

Malleolar fractures Anna Ekman, Lena Brauer

Introduction This case study presents a 24 year old male soccer player with an Anterior Cruciate Ligament (ACL) tear in his left knee.

Minimally Invasive Lumbar Fusion

Flying Swan Arthroscopic Labral Repair using a Tensioned Suture Bridge Construct

INTRODUCTION Cerclage Cable Vs. Monofilament Wire

Labral Repair. Surgical Protocol by Ronald Glousman, M.D. and Nicholas Sgaglione, M.D.

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

The information contained in this document is intended for healthcare professionals only.

PERIPROSTHETIC IMPLANTS

Arthroscopic Proximal Biceps Tenodesis Technique with PopLok Mark Albritton, M.D., McDonough, Georgia

Open and Endoscopic Forehead Lift. Plastic Surgery. For All Brow and Forehead Lift Procedures. Revolutionizing. Soft-Tissue Fixation


SHOULDER INSTABILITY. E. Edward Khalfayan, MD

Combined lesions of the glenoid labrum include labral

Integra. Subtalar MBA and bioblock Implant SURGICAL TECHNIQUE

A Technical Pearls Newsletter for Arthroscopists

DRAFT. Triathlon TS Knee System. Surgical Protocol. Version 1

with Medial Patellofemoral Ligament (MPFL) Reconstruction Surgical Protocol by Ronald Navarro, M.D.

Zimmer Natural Nail System. Cephalomedullary Nail Surgical Technique STANDARD

Knee Kinematics and Kinetics

Zimmer PSI Knee System For Use with Persona The Personalized Knee System Surgical Technique

Gear PEPSI CAN STOVE INSTRUCTIONS

TransFx External Fixation System Large and Intermediate Surgical Technique

Pre - Operative Rehabilitation Program for Anterior Cruciate Ligament Reconstruction

Lateral Ankle Instability Repair using TWINFIX Ti 3.5 mm Suture Anchors

Arthroscopic Shoulder Procedures. David C. Neuschwander MD. Shoulder Instability. Allegheny Health Network Orthopedic Associates of Pittsburgh

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

S-ROM NOILES. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Expert TN. Tibial Nail.

The information contained in this document is intended for healthcare professionals only.

Sports Radiology : Making a diagnosis or solving a problem

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

Zimmer PSI Knee System For Use with the NexGen Complete Knee System Surgical Technique

VERSYS HERITAGE CDH HIP PROSTHESIS. Surgical Technique for CDH Hip Arthroplasty

Post-Operative ACL Reconstruction Functional Rehabilitation Protocol

Current Status: Draft PolicyStat ID: EZIO

NCB Distal Femur System. Surgical Technique

Patient Information. Lateral Lumbar Interbody Fusion Surgery (LLIF).

MIN Set. Instruments for Minimally Invasive Neurosurgery. Aesculap Neurosurgery

Lentur Cable System. Surgical Technique

Zimmer Small Fragment Universal Locking System. Surgical Technique

Ankle Syndesmosis Surgical Protocol by Timothy Charlton, M.D.

Zimmer NexGen LCCK. Surgical Technique for use with LCCK 4-in-1 Instrumentation. Contact your Zimmer representative or visit us at

Cable System. For Orthopaedic Trauma Surgery.

Zimmer MOST Options System

Sports Medicine Instruments. shoulder small joint hip knee. Our Strengths Become. Your Solutions

Open and Endoscopic Forehead Lift. Plastic Surgery. For All Brow and Forehead Lift Procedures. Revolutionizing. Soft-Tissue Fixation

How To Perform An Elbow Operation

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

Posttraumatic medial ankle instability

Selection & Use of Surgical Needles

When is Hip Arthroscopy recommended?

INTUITION INSTRUMENTS SURGICAL TECHNIQUE

SPINAL FUSION. North American Spine Society Public Education Series

Zimmer NexGen CR-Flex and LPS-Flex Knees. Surgical Technique with Posterior Referencing Instrumentation

Post Surgical Care of Patella Luxation Repair

Surgical Technique. Struan H Coleman MD, PhD

TOWN CENTER ORTHOPAEDIC ASSOCIATES P.C. Labral Tears

Wrist and Hand. Patient Information Guide to Bone Fracture, Bone Reconstruction and Bone Fusion: Fractures of the Wrist and Hand: Carpal bones

MIS Direct Anterior Approach Surgical Protocol

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Surgical Technique and Reference Guide

Aesculap POSITION PCL. System for reconstructing the posterior cruciate ligament Surgical Technique. Aesculap Orthopaedics

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

Good morning, everyone! I m Sue Banta, a coding consultant for Amphion Medical. ambulatory knee and shoulder procedures.

Transcription:

Double Bone Plug Meniscus Reconstruction Surgical Technique Double Bone Plug Meniscus

Low Profile Reamer 2-0 FiberWire Meniscus Repair Needles Collared Pin & Coring Reamer Set RetroConstruction Drill Guide Set FlipCutter II The double bone plug technique for meniscal allograft reconstruction provides a method for implanting the meniscal allograft with rigid fixation at the horn attachments. It has been demonstrated that bony fixation at the attachment site allows for the maintenance of functional hoop stress by the meniscal allograft. 1 Graft Preparation Allow 25 minutes to thaw and dilute the graft. Proper handling instructions are included with the graft. Option 1 - Coring Reamer Technique Using a Collared Pin and corresponding size Coring Reamer 1 2 A 2.4 mm guide pin is drilled through the attachments of the allograft at angles that approximate the tunnel to be drilled in the tibia. The pin hole should be extended through the middle of the bone bridge. A Collared Pin is inserted into the bottom of the bone bridge, so that a Coring Reamer can be used to cut a dowel. 1. Chen M I, et al, Is it Important to Secure the Horns During Lateral Meniscal Transplantation A Cadaveric Study, The Journal of Arthroscopic and Related Surgery, 1996; 12: 174-181.

Option 2 - Freehand Technique Using a microsagittal saw and ronguers 1 2 Using a 1 mm microsagittal saw, make four box cuts around each of the meniscal horns. Start with the posterior cut, then the anterior cut. Create the medial and lateral cuts. Make these cuts in the same trajectory as the retrodrilled socket that will be drilled later. Move to the medial side to make sagittal cuts, about 10 mm posterior from the meniscus. To release the bone plug from the donor, cut the meniscus bone block to 10 mm in depth. Use a freehand technique to tubularize the bone plugs using ronguers and/or a small saw. Prepare the plugs to have a 7 to 8 mm posterior diameter (8 mm long), and a 9 mm anterior diameter (10 mm long). Suture Passing Complete these two steps for either technique 1 2 Pass size #2 FiberLoop through the posterior plug. A modified Kessler, or horizontal mattress suture incorporating meniscal tissue, is placed through the posterior attachment; the suture is pulled back down through the posterior plug. The anterior plug is prepared similarly with #2 FiberWire suture. Two vertical #2 FiberWire sutures are placed in the meniscus. The first is the posterior horn vertical suture, 5 mm from posterior bone plug. The second is the mid-body vertical suture, 15 mm from the posterior horn suture, toward the body of the meniscus. These provide two permanent sutures that will be tied over the capsule posteriorly upon implantation of the construct. Mark the anterior of the graft with an A. Not only will this denote the anterior portion, but also show where the last (most anterior) stitch should be placed on the graft. Mark the posterior of the graft with a P. It can be beneficial to colorize the posterior rim so when the graft is passed, the color acts as a visual indicator to show that the graft has not rotated or twisted across the joint.

Posterior Tunnel Preparation Anatomic position: The posterior horn socket will be retrodrilled through the anterior most portion of the residual nub of the meniscus attachment point. It should be appropriately and anatomically juxtaposed to the PCL. This socket should be just off the shoulder of the cartilaginous portion of the plateau and just behind the eminence medially. 1 The FlipCutter is flipped into its retrodrilling position and drilled backward to a depth of 10 mm. The rubber grommet on the FlipCutter is used to measure this 10 mm distance. The posterior tunnel should be drilled 1 mm larger than the posterior plug diameter. The RetroConstruction guide with multi-use hook is positioned on the middle of the posterior remnant attachment at an angle that is as perpendicular to the tibial plateau as possible. Choose a FlipCutter size that is 1 mm larger than the diameter of the bone plugs on the donor meniscus. The FlipCutter is drilled into the middle of the posterior remnant. The guide is removed and the cannula is tapped into bone. After the posterior tunnel is drilled, use a Curved Rasp or shaver to remove any extraneous pieces of tissue from around the tunnel s superior rim. Any piece of soft tissue or cartilage will present difficulties in reducing the posterior plug. Pass a FiberStick through the drilled tunnel and retrieve through the portal. Standard inside/out suturing technique is followed by a 4 cm incision made on the posteriomedial aspect of the knee. Dissect down to the medial head of the gastrocnemius. Make a small vertical incision and dissect further to the posteromedial capsule. 2 Pass a FiberStick through the FlipCutter drill guide and retrieve the passing sutures through the medial portal.

Passing the Allograft With direct visualization, pass a Micro SutureLasso through the notch in the dilated portion that was created for the passage of the posterior horn. This SutureLasso will be used to pass a passing suture out of the posterior capsule. This passing suture will be used to deliver the posterior horn vertical suture that was placed on the meniscal transplant construct. With the knee in valgus position, this same technique will be used to place a second passing suture at the mid-body of the capsule. This passing suture will be used to deliver the mid-body vertical suture that was placed on the meniscal transplant construct. A PassPort Button Cannula can aid in suture management and avoid a soft-tissue bridge between passing sutures. It should be used in at least one anterior portal that is ipsilateral to the transplant. This is critical so the graft does not twist on itself during implantation. Be sure to remove the cannula before passing the allograft, while maintaining suture segregation. Pass the three posterior passing sutures on the allograft in the following order: 1. Tie the suture on the posterior horn bone plug to the passing suture that was previously placed through the posterior socket. Note: Do not pass the meniscus at this time. 2. Pass the posterior horn passing sutures. 3. Pass the mid-body passing sutures. 1 Securing the Anterior Plug With adequate space, pass the graft around the gutter applying valgus stress on the knee. Begin inserting the allograft by first passing the posterior horn. Continue to take up any slack in the other sutures as the allograft is inserted. Use a probe to help guide the posterior bone plug into place. A Meniscal Probe or blunt instrument is used to maneuver the posterior plug around the gutter, while applying gentle traction on the posterior suture. Visualize to ensure that the plug and the meniscus have reduced properly. Pass the posterior horn suture through the capsule and mid-body sutures and tie. 2 Use the 2.4 mm Drill Sleeve to protect the patella and soft tissues to deliver a 2.4 mm pin in the correct anatomic position of the anterior meniscus attachment. Use a Low Profile Reamer to drill a 10 mm deep socket. Ensure that the anterior horn sutures are safely out of the way before drilling.

3 A SwiveLock Anchor is used to press fit the bone plug in the socket. The leading edge of the SwiveLock reduces the bone plug. The trailing aspect of the SwiveLock is placed on the notch side of the bone plug and acts as an interference screw to lock the anterior bone plug and meniscus in place. Alternate Technique: A through tunnel can be made with a 2.4 mm pin to secure the anterior plug using a suture button. Suturing the Allograft To attach the meniscus, bring the capsule to the meniscus (instead of the meniscus to the capsule) after both bone plugs are in place. If the posterior bone plug is placed and the meniscus is sewn to the capsule, there may not be enough graft remaining to attach the anterior plug. 4 The anterior sutures of the meniscocapsular interface may be placed under direct visualization. Size 2-0 absorbable suture is frequently used for this application. The arthrotomy should be closed so that the remaining sutures can be placed using routine arthroscopic meniscal repair techniques with 2-0 FiberWire Meniscus Repair Needles. Remove the posteromedial guide suture, as it is unlikely to be in the proper anatomic position to serve as a fixation suture. Add vertical sutures for additional strength. Routinely, 6-8 sutures are used to secure the peripheral interface.

ORDERING INFORMATION RetroConstruction Drill Guide Set Coring Reamer & Collared Pin Set, 9 mm Coring Reamer & Collared Pin Set, 10 mm Low Profile Reamer, 10 mm Suture Retriever Suture Cutter AR-1510S AR-1223S AR-1224S AR-1410LP AR-12540 AR-12250 DISPOSABLES: #2 FiberLoop, straight AR-7234 FiberStick, #2 FiberWire, 50 AR-7209 TigerStick, #2 TigerWire, 50 AR-7209T #2 FiberWire, 38 w/tapered Needle AR-7200 Micro SutureLasso, minor bend AR-8701 FlipCutter IIs, 6 mm 13 mm AR-1204AF-60 130 Suture Button, 3.5 mm AR-8920 Suture Button, 12 mm round AR-8922 2-0 FiberWire Meniscus Repair Needles AR-7223 Protector Meniscus Surturing Set AR-4060S Meniscal Repair Joystick System AR-4007JS BioComposite SwiveLock, 3.5 mm Drill for 3.5 mm BioComposite SwiveLock AR-2325BCC AR-2325D PassPort Button Cannulas, 6 mm x 2 5 cm AR-6592-06-20 50 PassPort Button Cannulas, 8 mm x 2 5 cm AR-6592-08-20 50 PassPort Button Cannulas, 10 mm x 2 5 cm AR-6592-10-20 50

This description of technique is provided as an educational tool and clinical aid to assist properly licensed medical professionals in the usage of specific Arthrex products. As part of this professional usage, the medical professional must use their professional judgment in making any final determinations in product usage and technique. In doing so, the medical professional should rely on their own training and experience and should conduct a thorough review of pertinent medical literature and the product s Directions For Use. U.S. PATENT NO. 6,716,234; 7,147,651 and PATENT PENDING 2012, Arthrex Inc. All rights reserved. LT1-0106-EN_A