OPERATOR S MANUAL Vet Pump



Similar documents
JORVET INFUSION PUMP J1060M OPERATOR MANUAL

Regents of the University of Michigan 5/7/2015. Review pump functionality, sets and accessories Understand key process steps for

Infusovet Veterinary Infusion Pump

with FLASH TIPS PLUM A+ INFUSION SYSTEM OPERATING INSTRUCTIONS REFER TO SYSTEM OPERATING MANUAL FOR COMPLETE OPERATING INSTRUCTIONS

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Record Cleaning Machine

BLOOD COLLECTION MIXER

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

MAINTENANCE & TROUBLESHOOTING

COASTAL AMUSEMENTS INC.

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

NIKI V4 Infusion Pump

Wireless Home Security System Product Manual (Model #80355)

Digital Photo Picture Frame. Operation Manual

National- Spencer Inc.

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Dehumidifier Users manual. For Models: DH45S DH65S

FC6 FOOT CONTROLLER OWNER S MANUAL

W850. Maintenance Guide

MAINTENANCE & TROUBLESHOOTING

CAD-05 Kit GSM Auto Dialer. Owner s Manual

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso

CarePartner Telephone With Reminders

Lexmark E260, E260d, and E260dn Series. Maintenance Guide

Polaris 9300 & 9400 Series Robotic Cleaner

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

4.3-inch Back-Up Camera

ENTERALITE INFINITY PUMP Instructions for use

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos , and

Mini multi-purpose sewing machine

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Lenovo IdeaPad Miix 10

Portable Air Conditioner

Operating Manual Color Changing Fountains

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

DAB+ / FM Tuner Model: TU-201

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

Auto Dialer. Manual E-921APQ E-921GPQ

Back-UPS Pro 1300/1500 Installation and Operation

GSM Alarm System User Manual

User Installation Guide

Bottom Loading Water Dispenser

CONTIENTS. 1. SPECIFICATIONS (mm) CAUTIONS INSTALLATION INSTRUCTION


Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

Wireless Home Security Alarm System AM 500

Single Day Alarm Clock with. Bluetooth and USB Play-through

DP-DMX20L 4 CHANNEL DMX DIMMER PACK MODE MENU DISPLAY. OUTPUT: 10A/CH, TOTAL 20A Max. DMX CHANNEL RECEIVE TOTAL DMX CHANNEL DIMMER / SWITCH

Installation Instructions S

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Hygro-Thermometer + InfraRed Thermometer Model RH101

Deluxe Bottle Warmer

OPERATION GUIDE. IMPORTANT NOTE: For more information see our instructional video online at model no.

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

HP ProDisplay P19A LED Backlit Monitor. User Guide

3. Enter the first five digits of desired frequency ( for MHz).

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

EKOS Cart. Instructions for Use

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

AutoRanging Digital MultiMeter

Streaming Potential System (SPT1000, SPD1000)

ExStik TM ph Waterproof Meters

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

MINI ELECTRIC SEWING MACHINE OPERATION MANUAL

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Windows 10.1 Tablet (UB-15MS10 and UB-15MS10SA) FAQ December 2014

Operation Manual FOR & 14030

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Leaf River Outdoor Products Vibrashine, Inc. P.O. Box 557 Taylorsville, MS (601) FAX (601)

- 2 - IMPORTANT SAFETY REMINDERS

Get Me Cool Now Portable Air Conditioner User s Manual

Fully Automatic Washing Machine User manual

GSM Door Phone System

BeoCom 2. Get started

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

18974 (736) Singer No SINGER No ELECTRIC SEWING MACHINE INSTRUCTION MANUAL

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

ReSound Unite TV FREQUENTLY ASKED QUESTIONS. Setup & Configuration. Use & Operation. Troubleshooting

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

How To Program An Autodialer

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

SETTING UP YOUR 6000 SERIES TIME RECORDER

Ambiente Quick Reference Manual

Lenovo Miix 2 8. User Guide. Read the safety notices and important tips in the included manuals before using your computer.

AD-01 Slave Auto Dialer. Owner s Manual

POOL ROVER SERIES 2 ROBOTIC POOL CLEANER PRODUCT SETTINGS AND TROUBLESHOOTING GUIDE

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

16/32 Channel 1U Rack Mount CCTV Power Supply

OPL BASIC. Dosing System for Professional Laundry machines. Contents

GUTTER MACHINE CONTROLS STANDARD

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Transcription:

OPERATOR S MANUAL Vet Pump Volumetric Infusion Pump J-1060 Jorgensen Laboratories, Inc. 1450 Van Buren Avenue Loveland, CO 80538 Please read the instructions in this manual before operating

Quick Setup 1. Set up IV set & fluids. 2. Prime IV tubing to remove air bubbles. 3. Open pump door & thread tubing into place, close & lock. 4. Connect drip counter to drip chamber. 5. Power unit by pressing. 6. Press keys up or down to input. 7. SELECT IV set-if using same type of IV set every time, enter drops/ml, this will be the default setting. 8. DROPS/M - (This option is rarely used, but a you must enter a number in the field in order for the pump to operate.) 9. ML/H -infusion rate at ml/hr, enter number, chime will sound after entry then down to next input program. 10. ML LIMIT will flash - enter desired total volume to be infused. 11. down key will flash 0 in ML 12. Press to start pumping. TOTAL 13. KVO (Keep Vein Open) is an automatic feature of this unit preset at 1 ml per hour after infusion is complete. 14. Hold down for 2 seconds to turn off unit after infusion is complete

SEQUENCING THE ARROW KEYS Pressing the & will go through the input program of the pump. The various icons will flash and call for input on the numeric keypad. If no input is neeeded or no change is necessary, pressing the arrow key again will take you to the next icon and continue to circle through the input program. Starts sequence with arrow, reverse if using the arrow Adjust - = adjustment of accuracy in minus (-)% Adjust + = adjustment of accuracy in plus (+)% SELECT IV SET = select drops/ml for that type of IV set DROPS/MIN = desired infused. Its more common to chose ml/hour infusion rate. However a value besides 0 must be put to this field. ML/H = ml/hour infusion rate. Entering a value here then pushing arrow down. ML/LIMIT = amount desired infused. Enter amount then push down arrow ML/TOTAL = amount infused at a point in time while pumping. Always starts at 0. You can not enter a value in here because the number represents what has been infused. When this is flashing 0, the infusion pump can start pumping by pushing the key. 2

INSTRUCTIONS: If mounting on an IV pole, use the pole holder on the back panel. Place IV pole through the opening and tighten knob firmly. Power source: operator will now decide if AC wall outlet is used or the battery is chosen to provide power. 1. AC power: Plug into wall outlet. Turn power on via switch on the back panel. 2. Press start for a second. The AC indicator should illuminate. 3. Battery power desired: it is not necessary to plug into AC receptacle. Press for one second, the battery icon will illuminate. (fig.2) When battery is low, battery icon will flash. It will also flash LOW BATT in alarm section. Figure 1 REAR VIEW Drip Detector Hanger Convenient place to store drip detector when not in use. Pole Holder On/Off Power Switch AC Power Receptacle Class II type CF Drip-proof design 3 ALARM VOLUME OCCLUSION SENSITIVITY Antislipping Sheet Prevents pole from slipping Volume Control with waterproof cap Occlusion Sensitivity 8-step occlusion adjustment with waterproof cap

PRIME IV SET: 1. Attach IV set to IV solution with IV roller clamp closed completely. 2. Please note drip/ml on IV set packaging. Standard IV sets are 15 or 20 drops/ml, micro IV sets are 60 drops/ml. 3. Gently press drip chamber of IV set between your fingers a few times to fill chamber 1/4 to 1/3 full. 4. Release roller clamp & expel air from IV tubing. Then close roller clamp again. (See Figure 3) Roller clamp should be on IV Set below pump. Figure 2 FRONT VIEW LCD Display Legible screen at over 5 meters even under glare Alarm Lamp Flashes/lights when alarm conditon is present Numeric Keyboard Convenient infusion parameter setting Pump Door Cursor Arrows Power Display Identifi es AC power/battery use :AC Power :Battery 4

Thread IV Set Through: (Fig. 3) A 1. Pull metal door hinge to the left to open. 2. Leave slack in IV tubing above pump. B 3. Thread tubing through portal A. Be sure and push completely into slot. 4. Hang tubing straight & firm, then thread through tube guides B through E. Pull C clamp lever D to the left to open. D 5. Close pump door and lock C. E 6. Open roller clamp of IV set. Fig. 3 NOTE: Make sure there is no flow or dripping of IV set at distal end at this time. Attach Drip Detector: (Fig. 4) 1. Connect drip detector coiled cord to the back panel of the pump. 2. Place drip detector over drip chamber above fluid line but below spike drip opening. 3. Keep drip chamber vertical to obtain correct drip shape. Otherwise, frequent alarms will sound. 4. Keep drip detector away from intense light or direct sunlight. 5. Make sure inside of drip chamber does not have a lot of splash or drops on its side walls. Fig. 4 Power On Unit With power already on, press one second more, unit will chime & LCD display will illuminate. Unit will perform a self-check for an additional second. Self-check includes battery, drip detector & pump. If a problem exists, then an error code will show. (on LCD display, see figure 2) ATTENTION! All alarm messages must be addressed or pump will not function. The cursor arrows allow different modes or windows to be selected. The mode will flash & new input can be entered. 5

Type of IV Set: SELECT Move cursor buttons by pressing or. This cursor IV SET will flash. Input the number on the keypad for the IV set: i.e. either 15, 20 or 60. NOTE: The most common IV set is 20 drops/ml. When the cursor returns to flashing, the entry is confirmed and a different mode can be selected. That IV set drop/ml. will remain in unit memory for additional infusions until changed. There is no need to enter this field again unless IV set drip type is changed in subsequent uses. Input Flow Rate & Volume Unit: ML/H DROPS/M Press or to move cursor to either or to enter your flow setting. When the cursor is flashing, enter flow rate desired via numeric keypad. You MUST enter a number in DROPS/M in order to cursor down to ML/H. You can then enter ML/H. The unit will adjust DROPS/M accordingly. TYPE OF IV SET RANGE ml/hr RANGE Drops/m 15 & 20 drops/ml 1.0-999 1-333 60 drop/ml 1.0-150 1-150 Volume Limit A desired ml infusion amount can be entered as follows: Move cursor arrows to ML LIMIT Enter volume desired when cursor flashes, this will also be the default setting for subsequent setting. Keyboard Lock Function This is a security feature. Operator may want to lock keys to avoid accidental changes to the infusion. This is optional and does not have to be done during any infusion. 6

Keyboard Lock Function (cont.) Keyboard Lock: 1. Press button for 1.2 seconds to lock the system. No changes can be made to infusion parameter. The LOC will appear on screen. Press button for 1.2 seconds to unlock. Start Infusion Confirm that settings are correct. Press button to start infusion. The flow indicator light belt indicates flow. Finish Infusion When the infusion reaches the volume limit, the pump gives the empty alarm EMPTY to notify the completion of infusion. At this time, keep the KVO functioning (the minimum flow rate to prevent venous occlusion). 1. Press to stop KVO. 2. If additional fluids are required either: a. Input a new volume setting, or b. Press to clear volume limit back to 0 c. Connect to the solution container d. Press for infusion restart Turn Power Off This unit can be turned off during operation, or after infusion is complete. Press to stop the pump. Press and hold for 2 seconds to turn power completely off. 1. Turn off power AC switch on the back of the unit. 2. Before IV set is removed, open the pump door and turn clamp lever to the left to open the tube clamp. Selective Operations 1. To Pause/Restart Infusion: Press to pause infusion. Press again to restart infusion. ATTENTION: A pause lasting longer than 2 minutes will cause an automatic alarm ERR 3. Press to clear the alarm signal, then push to restart the pump. 7

Selective Operations (cont.) 2. To continue the infusion after restart is complete: a. Make sure that the residual volume is present in the solution container. b. Either change ML LIMIT to higher volume or press for 2 seconds. The ML TOTAL in the window will become 0. Press to restart infusion. Perform Purge Purge is used to prime IV tubing and remove any air from the line. Press and hold only when pump is not running. Release hold and purge will stop. NOTE: Purge volume is not caculated in total volume infused. NOTE: Air in tubing may cause alarm to sound, but infusion will not stop. Adjust Flow Unit The Vet Pump allows for adjustment of flow rate for various IV sets because of the variance in the manufacturer of different brands of IV sets. A variance can also occur because of: 1. High surface tension of solutions 2. Deterioration of IV tubing due to long time use. The best solution for adjusting for IV set variance is physiological saline. Adjustment is best done at a common infusion rate, so select a common infusion rate, then wait for 50ml to be infused before starting adjustment changes. Press or to ADJUST + or ADJUST -, then enter numeric value and press to start the infusion. The rate will automatically be compensated. 8

Battery Supply The pump will operate in battery mode if: 1. AC cord is disconnected or AC power fails. 2. AC power switch at back of unit is turned off. Battery life is approximately 5 hours when fully charged at 30 drops/min infusion rate. When the battery is low: Low Batt will light. The power will then shut off in less than 10 minutes if AC is not provided. Occlusion Screw Valve The pressure or sensitivity to where the pump will show an occlusion can be adjusted via adjustment screw on the back of the unit. Remove the black protective cap to expose the screw valve. The pressure setting can be seen by watching the light belt on the front panel. Adjust the screw to increase or decrease the adjustments valve. There are 8 different settings in range from 40KPA to 140KPA. Occlusion Sensitivity Alarm Volume Adjustment Change the alarm volume by adjusting the screw on back panel of the unit. First remove the black protective cap. Turn setting to the right to increase sound or left to decrease sound. Warning Volume Toggle Switch Settings On the bottom of the pump are a series of 5 switches. These switches are used for analysis during any repair work & should not be tampered with during normal operation. NOTE: ON is down OFF is up. Make sure switches #2 through #5 are in user mode (OFF). 1 2 3 4 5 ON 1 2 3 4 5 ON SWITCH NO. MODE ON (DOWN) OFF (UP) FACTORY DEFAULT 1 VOICE NO SOUND SOUND OFF 2 WORK ENGINEERING USER OFF 3 WORK ENGINEERING USER OFF 4 WORK ENGINEERING USER OFF 5 WORK ENGINEERING USER OFF 9

Maintenance Never use organic solvents, alcohol, or abrasive cleaners to clean pump. The pump can not be autoclaved or placed in an ultrasonic cleaner. Clean with soft cloth using a mild detergent & dry well. Air Detector Sensor Gently wipe with damp cloth or swab. Be careful not to damage the sensor surface. Finger Cassette Remove the finger cassette. Wash with hot water and wipe clean. Dry and replace in the unit. AIR DETECTOR SENSOR FINGER CASSETTE Battery Charge the battery for at least 16 hours initially. Normal battery life is 3 years Recharge the battery before using after extended periods of nonuse. (FINGER CASSETTE REMOVED FROM UNIT) Charging Battery Connect power cord with AC power. Press for 1 second, the light will blink. The battery will begin charging. Press for 2 seconds to turn power off. Unit MUST be turned off for the battery to charge. After 16 hours battery will be fully charged. 10

TROUBLESHOOTING ALARM PROBABLE CAUSES REMEDY AIR DOOR IV set or line is disconnected or not set up properly. Air is somewhere in IV line. Occlusion in IV container or IV line ABOVE pump. Pump door is open. Check IV set flow & chamber. Close roller clamp Open pump door & check for air bubbles in IV line. Tap any bubbles back up into the drip chamber. Check IV line or set for blockage. Press the key after determining cause and correcting it. Close pump door and lever until it locks. OCCL LOW BATT LOC EMPTY Occlusion in IV tubing or IV catheter BELOW pump. Battery voltage is low. The keypad buttons are locked. Infusion has finished. 1. Tubing is kinked. 2. Roller clamp is closed. 3. Catheter or venipuncture needle is blocked. Promptly connect power cord into wall socket. Make sure switch is ON on back of the unit. Press for 2 seconds to unlock the keypad. 1. Replace fluid bag and adjust drip chamber fluid level. 2. Infusion is finished. Remove IV set from pump. 11

TROUBLESHOOTING (Continued) ALARM PROBABLE CAUSES REMEDY Err1 Battery missing or failed. Check battery. It may need replacement. Err2 Err3 Err4 Err5 Err6 Err7 Err8 Err9 Drip detector disconnected. Unit has been paused for more than 2 minutes. Leakage. IV drip counter problem. Pump is not running. IV set drip Error IV drip setting Infusion abnormal 12 1. Make sure drip detector is connected & mounted on drip chamber. 2. Check to make sure drip sensor is not soiled or obstructed. Press to continue pause or to restart infusion. When in pause mode, the drip detector continues to count drops. Check IV line placement in pump. IV fluid bag empty. Drip chamber has fogged or is sloping. IV tubing is defective or not mounted properly in pump. Check the finger cassette in pump. Tubing or chamber sloped. Tube clamp not opened. IV drip/ml setting not in accord with actual IV set. Check drip detector, drip chamber full, blockage in IV container.

OTHER TROUBLESHOOTING Symptom Press power does not come on: Battery is not mounted properly Check battery connection Purge not possible: Finger cassette is soiled or dirty (Strange noise from finger cassette) 1) Open pump door 2) Remove finger cassette & clean it 3) Rotates gear to see if it moves smoothly Performance of air detector sensor located inside door at top channel 1) Turn power on. 2) Check if AIR alarms when IV set is not inserted into pump. 3) Mount an IV set and prime it. Close & lock pump door. Then check to see if the AIR alarm turns off. KEYS AND ICONS PLAY/PAUSE/START KEY 0/EMPTY KEY UP ARROW CURSOR KEY 9/KEYBOARD LOCK DOWN ARROW CURSOR KEY BATTERY ICON CLEAR KEY AC ICON PURGE KEY BELT LIGHT 13

Specification of JorVet Infusion pump Warranty 2 year limited warranty Flowrate 1ml/h-999ml/hr Flowrate adjustment 0.1 ml/hr Volume infused display 0-9999ml Volume limit 0-9999ml Purge rate 600ml/h IV set requirement standard 15 or 20 drop or micro 60 drop/ml Display color LCD with high backlights Occlusion pressure 40kpa-140kpa-8 adjustment levels. 1kpa=0.145psi Drip detection method infrared photo beam Power source 110v/50hz Battery rechargeable ni-hydrogen battery DC 12V Pumping type finger pump (detachable) Alarms air, door open, occlusion, pause, infusion complete, abnormal, leakage, tube slope Diagnostic Alarm low battery, damaged battery, abnormal drip detector, and abnormal peristaltic finger pump KVO (keep vein open) 1ml/h Weight 2.1kg (4.5lbs) Fluids most fluids except BLOOD Size 5 1/2 (w)x 7 (d)x 9 (h) Vet Pump J-1060 Jorgensen Laboratories, Inc. 1450 Van Buren Ave Loveland, Colorado 80538 Telephone: (800) 525-5614 www.jorvet.com Fax: (970)663-5042 Info@JorVet.com