Digital I/O: OUTPUT: Basic, Count, Count+, Smart+



Similar documents
IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

BW-500 BED WEIGHER USER MANUAL

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

SYSTEM 45. C R H Electronics Design

SYSTEM 4C. C R H Electronics Design

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

Troubleshooting and Diagnostics

GSM Autodialer Professional GJD700 Speech & Text Autodialer

2M IR Mini Dome Quick Installation Guide

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc.

Fanuc 0 M/T Model C Serial (RS232) Connection Guide

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

POINTS POSITION INDICATOR PPI4

NC-12 Modbus Application

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

ATS Communication Overview

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming

INSTALLATION INSTRUCTIONS

Rev GSM base station. Installation instructions

Table of Contents Getting Started... 3 The Motors... 4 The Control Board... 5 Setting up the Computer with Mach Starting up the Equipment...

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

FIREDEX Conventional Fire Panels

Programming the On-Chip Flash on a phycore-xc161 phycore-xc167

How To Use An Ams 5812 Pressure Sensor With A Usb Starter Kit

A relay capable of the generator s starter amps with a coil that draws no more than 12V.

FACTORY AUTOMATION LGS SERIES INTELLIGENT

Setup guide. point to point wall plate extenders

Repeaters and Mimics Data Sheet

User Guide Reflow Toaster Oven Controller

Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene

Leaf River Outdoor Products Vibrashine, Inc. P.O. Box 557 Taylorsville, MS (601) FAX (601)

How to read this guide

To Purchase This Item, Visit BMI Gaming Operation Manual

MIDECO 64-outputs MIDI note decoder USER MANUAL. Roman Sowa 2012

AC-115 Compact Networked Single Door Controller. Installation and User Manual

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

Paragon Explorer Lite Communication Software

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Modification of an AOR AR-8600 receiver to tune it with a ACECO FC-3002 frequency finder

WinLIN Setup and Operation:

TDAS G5-DB Hardware User s Manual

PUSH BUTTON START INSTALLATION MANUAL

AVR Butterfly Training. Atmel Norway, AVR Applications Group

connecdim Gateway G1 Ethernet TCP/IP to DALI

NOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Application/Connection Examples

User and installation manual

SE05: Getting Started with Cognex DataMan Bar Code Readers - Hands On Lab Werner Solution Expo April 8 & 9

Features, Benefits, and Operation

Points Position Indicator (PPI1) for Points Motors with Common Ground

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

User Guide. Model Insulation Tester / Megohmmeter

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

INSTRUCTIONS FOR MAGNUM DS TRIP UNIT TESTING USING TEST KIT SYLES 140D481G02R, 140D481G02RR, 140D481G03 AND 140D481G04

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

BMW CAR-PC MONITOR MODEL SPECIFICATION BMW3/5 SERIES. Model Name : BMW-100P Paper Version : Ver 1.0

Digital Keypad Use s Manual

Bluetooth HC-06 with serial port module Easy guide

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/

INSTALLATION MANUAL XM3 Reader

PM1122 INT DIGITAL INTERFACE REMOTE

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

PARAMOUNT ME MOUNTING AND WIRING KITS FOR USE WITH THE TCF-S / IFW / Pyxis Revised 3/18/2008

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

PHYS 2P32 Project: MIDI for Arduino/ 8 Note Keyboard

MOTION COORDINATOR MC206X Quick Connection Guide

4. Do you have a VGA splitter ( Y Cable)? a document camera?

Using the NI 17xx Smart Camera Direct Drive Lighting Controller

1. SAFETY INFORMATION

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Air conditioning, electrical testing

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Manual. CANcaseXL CANcaseXL log. Version 5.1 English

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Using the Parani SD1000U/SD1000 with Carlson SurvCE

THE INPUT/OUTPUT SYSTEM. Key Points

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

Installation and Operation Guide

INSTALLATION & SERVICE MANUAL. Display Panel

4-Channel Thermometer / Datalogger

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

GPS INSTALLATION & USER GUIDE. Internet. Compatible with the following controllers. Nomad SD/SD2. ALL RIGHTS RESERVED Rev

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE

Connecting the Console Port to a PC

LDG DTS-4/4R Desktop Coaxial Switch / Remote

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

8 Channel Status Input Panel model SIP-8

B/S/H/ Error codes and service programmes PH

A-307. Mobile Data Terminal. Android OS Platform Datasheet

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Universal Serial Bus (USB) to DH-485 Interface Converter

Transcription:

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+ The digital I/O option port in the 4-Series provides us with 4 optically isolated inputs and 4 optically isolated outputs. All power is supplied externally. In this demo we will look at connecting an output to a 4 Series Count+ scale. The Digital I/O option kit for basic, count and count + is part number 22013142. The option installs inside the scale (or terminal) and field connection is via a 9 pin female connector mounted on the connector plate at the rear of the scale. In a 4-Series Count+ scale the option is installed as port 2, port 1 remains as RS232. In the Count+ scale we can have one option, so if we choose digital I/O we can not add any further options, such as Ethernet. The installation of the Digital I/O kit is explained in the installation instructions, 22013616, supplied with the kit. The kit may also be factory installed when ordered together with the scale. See specifications. Com 2 Digital Com 1 RS 232 Connector plate on rear of scale / terminal. How does the input circuit work? The output circuit is optically isolated from the internal circuitry, which means you must provide an external power source. When we connect the external power soured to the output circuit an optical coupler is energized, turning on the output signal.

External load. Max current 100 ma Max voltage 30 VDC Digital Option Inside Scale. External Power Supply 5-30 VDC Circuit operation. The external load, such as a 12 VDC piezo buzzer, is connected to the + VDC of the external power supply. The switched side of the load is connected to output 0, on pin 2 (OUT0) of the 9 pin Digital I/O connector. 0 volts of the power supply is connected to pin 1 (GND) of 9 pin Digital I/O connector. When the output is turned on by the Digital I/O, the optic coupler turns on completing the circuit. Electrical current flows through the circuit, energizing the piezo buzzer. The outputs are numbered 0 3 on the hardware and 1-4 in the scale setup menus. The voltage drop across the optic coupler is approximately 1 volt. With a12 volt supply, we would drop 1 volt across the coupler and 11 volts across piezo buzzer. The piezo buzzer we selected for this demo has a maximum current draw of 15 ma, well beneath our limit of 100 ma. For heavier loads such as relay coils, consider using the METTLER TOLEDO Relay 4 I/O as the electrical interface between the 4-Series Digital I/O and the field equipment. Operation of 4 Series Count+ with digital output 1 assigned to GOOD.

The Count+ scale is operating in the +/- Checkweighing mode, when the load on the scale is in the OK zone, the GOOD output turns the piezo buzzer on. Hardware installation: Wire circuit to pin 2 for output 0 and pin 1 for 0 volts. Scale Setup: Application / Checkweighing / Beeper - OFF / Setpt tol 10 %. Communication / Option / Digital / Output 1 / Good Operating in the +/- Checkweighing mode. Setting target / tolerance, we use 1000 grams as target. Enter 81 and hold the Target button until target appears in display Enter 1000 g *, touch the Enter (Print) key toler + will flash in the display Touch the Enter (Print) key again to enter the tolerance in percentage Enter 4.0 and touch the Enter (Print) key toler will flash in the display Touch the Enter (Print) key again to enter the tolerance in percentage Enter 4.0 and touch Enter (Print) button

The display goes back to weighing mode with - icon illuminated, indicating that the weight is less than the target. Once the weight passes 50% of the target value, the capacity display at the bottom increases linearly until the lower tolerance is passed. At this point, OK comes onto the display. After the upper tolerance is passed, a solid + appears to indicate the tolerance has been passed. * Note that the unit of the target is always the defined display unit of the scale. If the scale is set up as lb, you cannot change the target to grams during this step. You would first have to change the display to grams, set the target, and then change the scale back to lb. When you switch the units to lb, you must start target/checkweighing again by entering the memory location (81 in this case) and then pressing the Target button briefly. The unit will calculate the target weight and tolerance percentages relative to the new unit selected.

End of demo.