CONTROL OF A MULTI-FINGER PROSTHETIC HAND



Similar documents
How To Control A Prosthetic Leg

Improvement of control cable system of trans-humeral body-powered prostheses

Universal Exoskeleton Arm Design for Rehabilitation

Frequently Asked Questions

Heikki Uustal, MD Prosthetic/Orthotic Team JFK-Johnson Rehab Institute Edison, NJ

UOM Robotics and Industrial Automation Laboratory

Heikki Uustal, MD Prosthetic/Orthotic Team JFK Johnson Rehab Institute Edison, NJ

International Standards for the Classification of Spinal Cord Injury Motor Exam Guide

Self-Range of Motion Exercises for Shoulders, Arms, Wrists, Fingers

This week. CENG 732 Computer Animation. Challenges in Human Modeling. Basic Arm Model

Industrial Robotics. Training Objective

Throwers Ten Exercise Program

Rotator Cuff Repair Protocol

Acquisition of EMG signals to recognize multiple Hand Gestures for Prosthesis Robotic Hand-A Review

Wrist Fracture. Please stick addressograph here


LSU Health Sciences Center Occupational Therapy Flexor Tendon Injury Treatment Protocol

Range of Motion. A guide for you after spinal cord injury. Spinal Cord Injury Rehabilitation Program

POLICY 2: DEATH AND PERMANENT DISABILITY

Adult Forearm Fractures

Author: Dr. Society of Electrophysio. Reference: Electrodes. should include: electrode shape size use. direction.

Radial Head Fracture Repair and Rehabilitation

Scooter, 3 wheeled cobot North Western University. PERCRO Exoskeleton

A 5 Degree Feedback Control Robotic Arm (Haptic Arm)

Integra. MCP Joint Replacement PATIENT INFORMATION

ROBOT END EFFECTORS SCRIPT

COMPUTER-RELATED MUSCLE, TENDON, AND JOINT INJURIES

How To Recover From A Surgical Wound From A Cast

Potential for new technologies in clinical practice

Passive Range of Motion Exercises

Restorative Nursing Teleconference Script

What you need to know about...

Splinting for individuals with Spinal Cord Injury

Beware! your mouse can bite your hand!

ELEC 811 Skeletal Muscle Anatomy and Function. Skeletal muscles act on bones to produce movement of the limb and to move (lift and carry) objects.

MOTION CONTROL. Special issue on. A helping hand from robotics, page 56 PIEZO-DRIVEN STAGE MAKES MOVES IN MICROMETERS, PAGE 18

WRIST EXAMINATION. Look. Feel. Move. Special Tests

HYFLAM D3: Report of Scenarios 08/02/2012

Muscle Movements, Types, and Names

THROWER S TEN EXERCISE PROGRAM

Access Control Using Smartcard And Passcode

features bebionic3 utilizes leading-edge technology and unique, ergonomic features that make it unlike any other hand available.

Chapter 7 The Wrist and Hand Joints

Shadow Dexterous Hand E1 Series (E1M3R, E1M3L, E1P1R, E1P1L) Technical Specification Release: 1 January 2013

Force/position control of a robotic system for transcranial magnetic stimulation

Hand and Upper Extremity Injuries in Outdoor Activities. John A. Schneider, M.D.

Time Domain and Frequency Domain Techniques For Multi Shaker Time Waveform Replication

Active Range of Motion: A. Flexion: Gently try to bend your wrist forward. Hold for 5 seconds. Repeat for 3 sets of 10.

OPTIMAL CORE TRAINING FOR FUNCTIONAL GAINS AND PEAK PERFORMANCE: CXWORX

BUILD A REVOLUTE COORDINATE ARM

Rehabilitation after shoulder dislocation

Manufacturing Guidelines

HUR Rehab Line H E A L T H & F I T N E S S E Q U I P M E N T

Scaphoid Fracture of the Wrist

Most active and intricate part of the upper extremity Especially vulnerable to injury Do not respond well to serious trauma. Magee, pg.

Weight Measurement Technology

Range of Motion Exercises

UNIT 1 INTRODUCTION TO NC MACHINE TOOLS

Massage and Movement

NEURAL PROSTHESES FOR SPINAL CORD INJURED SUBJECTS

Combined SLAP with Arthroscopic Rotator Cuff Repair Large to Massive Tears = or > 3 cm

UHealth Sports Medicine

Rotator Cuff Pathophysiology. treatment program that will effectively treat it. The tricky part about the shoulder is that it is a ball and

Evaluation and Design Strategy of an Upper Limb supporting for desktop work

Digital Systems Based on Principles and Applications of Electrical Engineering/Rizzoni (McGraw Hill

Biceps Tenodesis Protocol

Chapter 6. Components of Elasticity. Musculotendinous Unit. Behavioral Properties of the Musculotendinous Unit. Biomechanics of Skeletal Muscle

XM Owner s Manual POWER TOWER !CAUTION. Read all precautions and instructions in this manual before using this equipment.

NIH 5R24 HD

FUNDAMENTALS OF ROBOTICS

How To Cover Occupational Therapy

Trunk Strengthening and Muscle and Coordination Exercises for Lower Limb Amputees

Brachial Plexus Palsy

THE INFLUENCE OF WALL PAINTING ON SHOULDER MUSCLE ACTIVITY AND HORIZONTAL PUSH FORCE

Hemiplegic shoulder pain/shoulder subluxation

SLAP Repair Protocol

Did the worker s right hand condition arise out of and in the course of her employment, or was it due to the nature of that employment?

Closed-Loop Motion Control Simplifies Non-Destructive Testing

Medical Robotics. Control Modalities

Occupational Therapy and Upper Limb Amputee Rehabilitation: Occupational Focused Intervention. Matthew Sproats (BaAppSc OT)

Design and Implementation of a 4-Bar linkage Gripper

North Shore Shoulder Dr.Robert E. McLaughlin II SHOULDER Fax:

ABSTRACT. Emily Tai, Master of Science, Associate Professor David L. Akin Department of Aerospace Engineering

Leghe a memoria di forma come tecnologia di attuazione per la biorobotica

Rotator Cuff Surgery: Post-Operative Protocol for Mini-Open or Arthroscopic Rotator Cuff Repair

Strengthening Exercises - Below Knee Amputation

Natural grasping. G. Smit. Design and evaluation of a voluntary closing adaptive hand prosthesis

Repetitive Strain Injury (RSI)

Evaluating muscle injuries and residuals of shell fragment and gunshot wounds

Transcription:

CONTROL OF A MULTI-FINGER PROSTHETIC HAND William Craelius 1, Ricki L. Abboudi 1, Nicki Ann Newby 2 1 Rutgers University, Orthotic & Prosthetic Laboratory, Piscataway, NJ 2 Nian-Crae, Inc., Somerset, NJ ABSTRACT Our novel prosthetic hand is controlled by extrinsic flexor muscles and tendons of the metacarpal-phalangeal joints. The hand uses tendon-activated pneumatic (TAP) control and has provided most subjects, including amputees and those with congenital limb absence, control of multiple fingers of the hand. The TAP hand restores a degree of natural control over force, duration, and coordination of multiple finger movements. An operable hand will be demonstrated. BACKGROUND While modern robotic hands are highly dexterous, having many degrees of freedom, prosthetic hands function much as they did over a century ago, by single-joint grasping. Available hand prostheses are either body powered, or myoelectric devices that restore prehension. Standard body powered prostheses are controlled by a harness that couples shoulder movements to opening/closing of a prehensile hand. While harness-type controllers have proven reliable and robust for thousands of amputees over decades [1], their versatility is limited by the number of independent control motions practically possible: one. Myoelectric controllers may eventually - 255 - offer more degrees of freedom (DOF), but this number is limited by the ability of the user to learn unnatural movements to activate hand motions and the ability of the controller to decode the resulting electromyographic (EMG) signals [2,3]. Perhaps due to these limitations, myoelectric controllers still provide only one practical DOF, directed by flexionextension of arm muscles. Accordingly, intensive efforts are underway to extract more independent channels from EMGs, with advanced signal processing techniques, tactile feedback, complex user control schemes, or surgical re-innervation [4,5]. Even the most advanced controllers available today do not fully exploit the residual functions possessed by persons with missing limbs. These include the ability, at least in below elbow amputees, to possibly control their extrinsic muscles and tendons that flex the metacarpal-phalangeal joints. A controller that could transduce these volitional motions would thus restore, at least partially, the natural link between volition and movement, and would hence be biomimetic. Beyond providing finger control for hand prostheses, the TAP controller may

facilitate the transition to more complete hand restorations via surgery. METHODS System Design The overall design goal was to use natural tendon movements in the forearm to actuate virtual finger movement. A volitional tendon movement sliding within the residual limb causes a slight displacement of air in foam sensors apposed to the skin in that location. The resulting pressure differential is transduced, processed, and used to control a multi-finger hand. Subject Screening Twelve subjects filled out a questionnaire (minors with parental assistance) intended to provide demographic and consumer information. All subjects reported interest in multi-finger control and proportional control of force and velocity. Four had congenital deficiencies (2 female/2 male), and eight had acquired amputations (all male). Eight (including three with congenital ULRD) were myoelectric users, one used a body-powered hook, one had a cosmetic hand, and one had a cineplasty APRL hook. There is intense interest in this research as a result of media attention, and our database now includes over 80 potential candidates internationally, as well as many providers and physicians. Residual and sound limbs were examined and measured. Subjects were asked to perform finger flexions - 256 - while the examiner palpated the limb. Successful detection of movement on 9/12 subjects indicated acceptance into the next phase. Six successful candidates, 10 to 40 years of age, having a minimum of 1/3 the original length of the forearm and at least 3 tendons and/or muscle sites were selected for further testing. Two had congenital ULRD, and the rest had acquired amputations. Tests were performed to evaluate the sensitivity and specificity of the system, the ability of subjects to activate individual fingers, and the degree of control over the signals. Smart Socket Fabrication Sensor sites determined during the initial screening were optimized using a transparent test socket. Following optimization of the measurements and the final sensor locations, the sites were transferred back to a positive cast of the limb. A soft silicone sleeve was custom fitted to the cast, with the sensors embedded inside at predetermined locations. An acrylic laminate was fabricated over the silicone, with a wrist unit mounted on the distal end to allow for direct attachment of a prototype mechanical hand. Alternate smart sockets were made by affixing single TAP sensors with Velcro or glue at selected points on the socket.

RESULTS Virtual and Mechanical Hands Initial demonstrations of finger tapping were done using a computer program which displayed the TAP signals, along with a virtual hand having fingers that could be lit independently when the corresponding finger volition was detected. Some subjects, especially children, seemed to enjoy operating the virtual hand, and also watching their TAP signals on the computer screen [6]. The virtual hand proved to be a valuable training tool. The first 2 versions of our mechanical hand were simple robotic hands that allowed users to observe finger activations. The version 3 prototype hand was a laminated shell to which were attached fingers obtained from a commercial wooden hand (Becker Imperial, Hosmer-Dorrance), as shown below: (Nian-Crae, Inc.) wearable computer. Because of the simplicity of the requested movements, a straightforward decoding algorithm was used. Structural design of the version 3 hand proved effective. It consisted of an acrylic/carbon fiber shell to form the palmar structure, to which was attached fingers, thumb, and a wrist unit. The carbon fiber shell was a mirror image of the sound hand of an amputee, and was strong, light, and easily machined. Actuators were mounted in the shell, and linked to fingers. The finger bones were 2 bars articulating at an M-P and a P-P joint, inserted in a spring for passive extension. Two types of finger bone materials were tested: steel bars and nylon rod. Also tested was the return spring design: either internal or external to the bones. The thumb was mounted on a springloaded ratchet that had 2 stable positions: abducted and adducted. Structural and actuator designs are currently being further developed. A 2-position thumb was attached to permit either keyboard use or grasping. Linear actuators provided movement of 3 independent fingers, each having approximately 30 degrees of flexion, with a maximum of about 4 N of force. Software, written in 8051 code controlled the hand. The version 3 hardware microcontroller for the portable hand was the Log-a-Rhythm - 257 - Biomimetic Control A signal response matrix was generated for each subject, consisting of three rows, representing requested finger motions, and three columns, representing the three sensor locations, as shown below: Site T I L Intention T TT TI TL I IT II IL L LT LI LL

TT, for example, represents signal energy from the thumb sensor for an intended thumb movement; IT is from the same sensor for an intended index movement, and so on. To maximize the diagonals, subjects were instructed to use less force to help avoid cross signals. Several response matrices were obtained from each patient. An example is shown below. All subjects were able to produce at least one matrix comparable to the one shown. sequential finger commands. Results showed that diagonal signal energies were all well above zero and ranged from 1 to 22 db above noise. Sensitivity and specificity data were summarized as the percentages of true positives for diagonal sensors and true negatives for off-diagonal sensors, respectively. Within 3 or 4 sessions, each subject could elicit independent signals from each channel, with sensitivities and specificities approaching 100%. Some subjects acquired sufficient dexterity to play simple piano pieces with the hand. Figure 1: Response Matrix Traces represent squared signals derived from TAP sensors over a 9- second period of repetitive finger flexions. Using the response matrix, the levels of signals received from the requested (diagonal) channels and the cross-talk (off-diagonal) channels were compared. Ratios of energy levels were expressed in decibels (db): R ij = 10 log ( D i ), i=1,2,3; j=1,2 ( O ij ) where R ij is signal energy of sensor i with respect to sensor j, D i is the energy of diagonal sensor i, and O ij is the energy of the off-diagonal sensors with respect to each diagonal. Energies were calculated for the duration of each protocol, representing about 6-258 - Representative sensitivity data are shown below for 3 subjects. Similar results were found for specificity (not shown). 100 80 60 40 20 0 Sensitivity A B C D E F D1 D2 D3 Figure 2: Sensitivity of TAP System. Sensitivity data was summarized as the percentage of true positives for each diagonal sensor on each subject. Bars represent diagonal values (D i ) for each subject. Sensitivity was 100% for all subjects on at least two channels. Five or six data points were used in each case.

Dexterity Limits Requested movements (3 subjects) consisted of individual finger taps and grasping. Subjects were asked to sustain signal movements for variable times, and to apply forces of low, intermediate and high intensity. Average frequency of tested tapping movements was 2.5 Hz. Subjects were able to sustain supra-threshold signals for up to 3 seconds. Both grasping and sequential finger tapping were accomplished. When prompted to grasp an imaginary object at increasing levels of force, signal energy increased in approximate proportion to force perception and volition. Traces typical of 3 amputee subjects tested are shown below: Figure 3: Proportional Control. Subjects were prompted to grasp an imaginary object at increasing levels of force, subjectively determined. Signal energy increased in approximate proportion to force perception from low (top) to high (bottom). DISCUSSION The TAP hand offers amputees control of finger flexion using natural motor pathways. Most subjects, including those with relatively short and scarred residua, quickly gained control over several mechanical fingers. Slow typing and piano playing were demonstrated. Beyond providing dexterity, the TAP controller may facilitate the transition to more complete hand restorations. Acknowledgements The work is being supported by an STTR grant from the NIH to Nian- Crae, Inc. References 1. Atkins DJ, Heard DCY and Donovan WH: Epidemiologic overview of individuals with upperlimb loss and their reported research priorities. Journal of Prosthetics and Orthotics, 8(1): 2-11, 1996. 2. Graupe D and Cline WK: Functional separation of EMG signals via ARMA identification methods for prosthesis control purposes. IEEE Transactions on Systems, Man, and Cybernetics, SMC-5 (2): 252-259, 1975. 3. O Neill PA, Morin EL and Scott RN: Myoelectric signal characteristics from muscles in residual upper limbs. IEEE Transactions on Rehabilitation Engineering, 2(4): 266-270, 1994. - 259 -

4. Hudgins B, Parker P and Scott RN: A new strategy for multifunction myoelectric control. IEEE Transactions on Biomedical Engineering, 40(1): 82, 1993. 5. Kyberd PJ: The application of microprocessors to prosthetics. Proceedings of 9 th World Congress of the International Society for Prosthetics and Orthotics, p. 50, Amsterdam, The Netherlands, June 28- July 3, 1998. 6. Abboudi RL, Glass CA, Newby NA and Craelius W. A biomimetic controller for a multi-finger prosthesis, In Press, IEEE Transactions on Rehabilitation Engineering, June 1998. Author address and contact information: Dr. William Craelius Orthotic and Prosthetic Laboratory P.O. Box 909 Rutgers University Piscataway, NJ 08854 Craelius@rci.rutgers.edu Voice: 732-445-2369 FAX: 732-445-3753-260 -