Geothermal Climate Systems



Similar documents
NIBE ACCESSORIES. NIBE Accessories A NEW GENERATION OF HEAT PUMPS

Heat Recovery based on Exhaust Air

ECOCIAT. Domestic hot water heat recovery unit

Technical data. Danfoss DHP-A

Natural geothermal energy.

NIBE FIGHTER 2020

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

MOS GB F INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE F1330 LEK

Create the right atmosphere with renewables.

YOUR GUIDE TO HEAT PUMPS & SOLAR THERMAL

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

User manual. 086U6297 Rev. 9 EN

Rainwater Harvesting

NIBE F1145 GROUND SOURCE HEAT PUMP. Heat pump with rock, ground or lake as heat source. NIBE F1145

Electric Flow Boiler

CRAC Precision climate control units for data centres

User manual. 086U6297 Rev. 6 EN

User manual. Solid (FR 98,),

Cooking at the Speed of light!

Laddomat Charging unit

ROTEX gas hybrid heat pump. A strong team.

We have been working in an ideal climate for thirty years.

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Water Heater. Made in Sweden

Solar Hot Water Heaters

Field test of a novel combined solar thermal and heat pump system with an ice store

Description of functions

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +

ECOplus Solar Cylinder

Rotary screw compressors kw 5,5 7, , bar MODULO

Conlift1, Conlift2, Conlift2 ph+

HEAVY DUTY STORAGE GAS

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

How To Use A Water Source Heat Pump

Heating when you need it Cooling when you don t. NIBE SPLIT Air/water heat pump

LK Electric Boiler - 4,5

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Hybrid heat pumps. saving energy and reducing carbon emissions

ALL IN ONE. Heat Pump Water Heater

Cooling kw Heating kw

To find out more about installing a heat pump call or visit energysavingtrust.org.uk

HDA

The heat is there let s use it! Using free environmental heat from the air with heat pump technology for central heating and domestic hot water

Thermostatic valve Type AVTA

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

DAikin Altherma low temperature heat pump. end user leaflet

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

HERZ-Thermal Actuators

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

INSTALLATION AND MAINTENANCE INSTRUCTIONS F F2025

Installation and maintenance instructions. Danfoss Vent

RPV - RP - RA air handling units

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P Thermodynamic cycle Heat pump

LG Electronics AE Company, Commercial Air Conditioning

Energy Efficiency HOSPITALITY.

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

SWIMMING POOL HEAT PUMP Owners Manual

MOS GB FIGHTER INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE FIGHTER 2020 LEK

How Ground/Water Source Heat Pumps Work

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump

Glossary of Heating, Ventilation and Air Conditioning Terms

User manual. Atec. 086L0130 Rev. 1 EN

Refrigeration Compressed Air Dryer Buran Ultrapulse

Exploitation Tests of Borehole Heat Exchangers in the Laboratory of Renewable Energy Sources in Miekinia Poland

KONRAD. Hybrid Fancoil Series

Cool Design for Homes and Offices

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

omfort all-in-one applications for residential & commercial DAIKIN ALTHERMA HEATING CATALOGUE

WWZ High efficiency HYBRID heat pumps with E.V.I compressor in two sections

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

GEOTHERMAL HEATING AND COOLING INTRODUCTION

Transformer oil cooler ALFA A02

YUTAKI S. Domestic Heating

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

CHAPTER CONTENT PAGE. Hybrid: The perfect solution for all systems. Explanation of the - Heat Exchanger 4. Finishes 12

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

NIBE FIGHTER 1250 A B C D E F G

Overheating limit control

Solar Hot Water. What systems are available?

Itho Products for Hot and Boiling water. product-

Integrated Solar Radiant Systems

Operators manual Basic water heater

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

marine/bespoke split applications

Daikin Altherma hybrid heat pump. The natural combination

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

UNITOR VACUUM cleaners

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Transcription:

Geothermal Climate Systems www.nibe.com

Ground-source heat pumps using the soil or groundwater as the heat source Surface collector During the summer, solar heat is stored in the soil. This is either directly absorbed as insulation or as heat from rain and the air from the nearsurface layer of the soil. Using this energy for heating is a cost effective method. The highest yield can be obtained from soil with a high water content. The heat is extracted from the soil by means of buried plastic tubing. An environment-friendly, non-freezing emulsion of waterglycol circulates in the tubing. The soil above the earth collector may not be sealed off under any circumstances, i.e. by buildings, asphalt or concrete. Earth collectors do not require a permit. Installation depth is approx. 20 cm under the local frost line. Ground probe In the lower subsoil of the so-called near-surface geothermal layer lies a heat source which can be utilized all year long, which has an almost constant temperature. It can be used for all possible building types, large or small, public or private. Depending on the region it is also referred to as, vertical absorption, ground spit or ground lance. It requires little space and the ground probe can even be drilled on the smallest of plots. Therefore it is ideal for refurbishment or adaptation from a heating system fuelled by fossil fuels to the use of geothermal energy. As with a surface collector a mixture of waterglycol circulates in a closed circuit (similar to the cooling system of a car). Depending on the necessary size of the heat pump unit a specialized company ascertains the depth and amount of bore holes in which the u-shaped plastic tubing is installed and pressed, in order to achieve good heat transfer. Ground water If ground water is available and easily accessible, it can be utilized as a heat source due to the fact that it has a temperature of between 7 and 12 C all-year round. It is advisable not to pump water for single and two-family houses from a depth greater than approximately 15 m. This would lead to expenditures being too high. A distance of approximately 10 to 15 m should be kept between the withdrawal point (supply well) and the reinsertion point (deep-well) and furthermore the flow direction should be taken into consideration in order to avoid a flow shortcircuit. These installations require a permit and must meet statutory requirements. However, this is no problem for NIBE equipment, due to their ISO 14001-certification. An optimal protection according to 7 MWG is provided by the separator-exchanger-system. Function The cooling medium (water-glycol) is pumped through the closed circuit by the pump, which is installed in the unit. The medium absorbs the heat from the surface collector, NIBEcompact-absorber, the ground probe or the ground water (via the separator-exchanger) and carries it to the heat pump. The heating pump extracts heat from the medium with the heat carrier (evaporator) and simultaneously brings the refrigerant to a higher temperature level with the heat-pumping process (refrigerator principle). The de-heated cooling medium can then extract heat from the soil again and the process repeats itself.

Your energy consumption for heating will be lowered by 75% with the use of NIBE ground-source heat pumps. NIBE produces 15 different types of ground-source heat pumps, ranging from 5 kw to 40 kw. By using a cascade connection it is possible to achieve an output of 360 kw. The energy consumption for heating and hot water can be lowered by up to 75% in comparison to heating systems using fossil fuels. Borehole for ground probe WQA-VL WQA-RL Sealing between casing pipe and solid rock The casing pipe must be driven a minimum of 2 metres into the solid rock. Water table heat active drill depth Free cooling The installation can additionally be fitted with fan convectors, for example, in order to allow the connection of a cooling register. To avoid condensation, all pipes and other cold surfaces must be insulated with diffusion-proof material. Where the cooling demand is high, active cooling with the HPAC heating and cooling system is a useful and energetically favourable variant. Further information on page 11. Fan coil unit Expansion tank WQA-Inlet WQA-Outlet Heat source (soil / groundwater) Example: free cooling (passive cooling)

Heat pump with the soil, bedrock or groundwater FIGHTER 1120 FIGHTER 1120 FIGHTER 1120 has been equipped with a control panel which offers plenty of functions. The novelties are: Large control panel with clear symbols The easily understandable control simplifies the control and operation of the heat pump Double heat curves Programmable for climate and cooling control Clock Timer for temperature control Timer for hot water function Prepared for GSM- and Internet-integration Control unit for swimming pools Alarm logbook Choice of language Soft start relays Prepared for the configuration of four different installation systems Display of the refrigerant temperature is a heat pump for heating single and multifamily houses and industrial buildings. The FIGHTER 1120 is a versatile product with advanced control equipment. The control is also prepared for bivalent heating mode in combination with an oil or gas-fired boiler. This heat pump type is available in the output range of 5 to 17 kw in nine versions. A cartridge heater can be fitted in the factory installed electrical cartridge with 3 x 3 kw (accessory). The efficiency of the FIGHTER 1120 is high, thanks to a highly efficient compressor in a well-dimensioned refrigerant circuit. This results in the considerable coefficient of performance (COP) of 5,0 at 0 C incoming cooling medium temperature and 35 C outgoing heating medium temperature (excluding circulation pumps). The FIGHTER 1120 is designed with the compressor and the refrigerant unit housed in a separate enclosure for easier servicing. As a result the compressor features double sound-proofing, leading to very low noise levels. Circulation pumps and flexible hoses are already built-in. The heat source and heating circuits are connected at the top of the unit for ease of installation. Dirt filters are also included in the contents of delivery. The unit can be connected to a low-temperature distribution system such as radiators, convectors or underfloor heating/wall mounted heating. The FIGHTER 1120 is fitted with a microprocessor to ensure optimal and safe operation. Clear information about status, running time and all essential temperatures in the heat pump is presented on a two-line LCD display. This means that external plant thermometers are not necessary. The complete FIGHTER 1120 is enclosed in a robust frame and thanks to sturdy outer panels and effective sound insulation the unit is so quiet, that it does not have a negative effect on living comfort. To ensure simple installation and easy service most panels can easily be removed.

as the heat source The following docking options are available: Direct connection to a low-temperature radiator/underfloor heating system. The flow temperature is automatically matched to the actual outside temperature. Hot water can be heated in a separate water heater (type NIBE VPA) via a changeover valve. Docking to an existing oil/gas/wood-fuelled boiler or accumulator tank with water heater. The temperature of the heating system must be taken into account, because the upper temperature limit of heat pumps is lower than that of for instance oil or gas-fuelled boilers. Electrical cartridge (3 x 3 kw) for installation in the heat pump as well as room sensors, hot water control and add-on units are available as accessories. It is possible to cool via the heat source on warm summer days (free cooling). Contents of delivery (see page12) Accessories (see page 13) FIGHTER 1120 Dirt filter R25, R32 Temperature sensors with plug contact (hot water control resp. fixed condensing) Level vessel with safety valve for the heat source External sensor with enclosure Compression joint Insulation tape Aluminium tape Outer tubes for sensor Converter Electric addition ETS12 (3-phase) Immersion heater with 3 x 3 kw and a complete contactor set Electric addition ETS121 (1-phase), 3 x 2 kw Hot water control VST 11 Three-way valve with motor Room sensor RG 10 Room thermostat RT 10 Level switch NV10 Pool kit Pool 11 Extra Shunt ESV 20 Technical data FIGHTER 1120 Type FIGHTER 1120-5 8 11 6 8 10 12 15 17 Recorded capacity* (B 0 /W 35) kw 1.0 1.8.5 1.30 1.7,0.5.1.7 Emitted capacity* (B 0 /W 35) kw 4.8 8.3 11.5 6.4 8.2 10.0 11.7 14.6 17.0 COP at B0/W35.6.7.5 5.0 5.0 5.0,7.7.5 Height mm 1030 without adjustable feet (30 50 mm) Width mm 600 Depth mm 625 Net weight kg 170 190 200 175 195 200 15 225 230 Operating voltage V 0(1-phase+Zero) 4 00(3-phase+Zero) Refrigerant R407C * In accordance with EN 255 for heat source entry at 0 C / hot water flow at 35 C. The electric input for the circulation pumps is not included. Design specifications for different heat sources Type FIGHTER 1120-5 8 11 6 8 10 12 15 17 Ground heat, hose length** 200 300 400 2x300 2x250 2x350 250 400 325 2x250 400 2x300 2x250 2x350 2x300 2x400 2x350 3x300 Borehole depth for ground probe ** m 70 90 140 170 160 190 90 110 120 140 140 170 160 190 2x100 2x120 2x110 2x140 Heating medium flow l/s 0.10 0.19 0.31 0.13 0.18 0.22 0.26 0.31 0.36 Brine flow l/s 0.25 0.53 0.65 0.35 0.48 0.58 0.65 0.75 0.86 * Specifications relative to 100% Q N with 1800 operating hours heater and 200 operating hours hot water at 450 m above sea level ** Stated values are only approximate guide values, specifications for surface collector with PE-pipe 40 x 2,3. 5

Heat pump with the soil, bedrock or groundwater FIGHTER 1120 Docking with electrical immersion heater and hot water tank (floating condensing) NK EXP VXV B A VVG VVB VPA / ACK ELVVB UG T The FIGHTER 1120 prioritises the filling of hot water heating via the changeover valve (VXV). When the hot water tank/accumulator tank (VPA) is full, the changeover valve (VXV) switches to the heating circuit. The heat pump is then controlled by the outside temperature sensor (UG) in combination with the built-in flow sensor (FG). The immersion heater (ELK) is switched on automatically, when the energy demand exceeds the capacity of the heat pump. The additional systems ETS 11 and VST 11 are necessary for this option. BK / JK FG ELK Docking with oil-fuelled boiler (floating condensing) NK NK BK / JK PG EXP Oil-fired Oljepanna boiler EXP SV VXV B A FG RG BV VXV VVG B A FG ELK VVG VVB / ACK VVB VPA / ACK T UG ELVVB FIGHTER 1120 prioritises filling of the water heater (VPA). When the hot water reaches the set temperature, the changeover valve switches to the heating circuit. If the heat pump cannot maintain the correct flow temperature, the oil-fired boiler starts, which also opens the mixing valve (SV). This control option is automatically activated if a boiler sensor has been installed. The flow sensor (FG) and the return sensor (RG) must be located on the main pipe to the radiators. The accessory VST 11 is necessary for this option. UG BK / JK T Abbreviations Shut-off valve BK/JK Brine/Ground collector BV Check valve ELK Electrical cartridge EL VVB Electrical hot water tank NK Level vessel NK Dirt filter Safety valve Kv Cold water Ww Hot water PG PG FG VVG UG RG VPA VXV SV Oljepanna EXP SV Boiler temperature sensor FG Flow sensor Hot water sensor RG Outdoor temperature sensor Return temperature sensor Hot water tank/accumulator tank Changeover VXV valve Mixer valve B A KV VV UG Med blandningsventil ELVVB VVG VVB / ACK 6

as the heat source FIGHTER 1220 Heat pump unit with integrated hot water tank - for brine or ground water as the heat source. FIGHTER 1220 is a complete heat pump unit for heating singlefamily houses. This type of unit is available in seven different variants with output levels from 5 to 12 kw. The efficiency of the FIGHTER 1220 is high, thanks to a highly efficient compressor in a well-dimensioned refrigerant circuit. This results in the considerable coefficient of performance (COP) of 5,0 at 0 C incoming cooling medium temperature and 35 C outgoing heating medium temperature (including circulation pumps). The FIGHTER 1220 is designed in such a manner, that the compressor and the refrigerant unit is housed in a separate enclosure for easier servicing. As a result the compressor features double sound-proofing, resulting in very low noise levels. Both the circulation pumps are built-in and the heat source circuit can be connected to the left or right-hand side of the unit. Dirt filters are also included in the contents of delivery. The FIGHTER 1220 is fitted with a 160-litre (available in different corrosion protection), double-jacket hot water heater, which is insulated with polyurethane foam to minimise heat loss. The built-in three-stage 9 kw cartridge heater can be switched on automatically if needed. The unit can be connected to a low-temperature distribution system such as radiators, convectors or underfloor heating. The FIGHTER 1220 is fitted with a microprocessor to ensure optimal and safe operation. Clear information about status, running time and all essential temperatures in the heat pump are presented on a two-line LCD display. This means that external plant thermometers are not necessary. The complete FIGHTER 1220 is enclosed in a robust frame and thanks to sturdy outer panels and effective sound insulation the unit is so quiet, that it does not have a negative effect on living comfort. To ensure simple installation and easy service most panels can easily be removed. It is possible to cool via the heat source on hot summer days. The FIGHTER 1220 has been equipped with a control panel which offers plenty of functions. The novelties are: Larger control panel with clear symbols The easily understandable control simplifies the control and operation of the heat pump Double heat curves Programmable for climate and cooling control Clock Timer for temperature control Timer for hot water function Prepared for GSM- and Internet-integration Control unit for swimming pools Alarm logbook Choice of language Soft start relays Prepared for the configuration of four different installation systems Display of the refrigerant temperature 7

Complete heat pump with soil, rock or groundwater FIGHTER 1220 Bleed screw Seamless freon-free polyurethane insulation Hot water tank (available: enamelled, copper or stainless steel) Microprocessor Connection of the heat source possible on the right or left-hand side Evaporator External sensor controlled automatic heating function Heat exchanger for heating circuit Drying filter 3 x 3 kw immersion heater Extensible sound-proofed compressor module Changeover valve for heating circuit and hot water Compressor 5 12 kw Heat sources - circulation pump Expansion valve Heating circuit - circulation pump Adjustable feet Flexible hoses Contents of delivery (see page 12) FIGHTER 1220 Outdoor temperature sensor Dirt filter Compression joint Level vessel with safety valve for the brine Anchoring clamps Isolated heat source connection pipes Transformers for load control Accessories (see page 13) Room sensor RG 10 Room thermostat RT 10 Level switch NV10 Pool kit Pool 11 ESV 20 Extra shunt 8

as the heat source Closed Brine out T BK / JK Function principle F 1220 Hot water circulation FIGHTER 1220 consists of heat pump, hot water tank, cartridge heater, circulation pumps and control system. Water heater FIGHTER 1220 must be connected to a heat source and heating circuit. Double jacket The heat absorption from the heat source (soil, brine, ground water) is usually performed by a closed system in which a mixture of water and antifreeze circulates. Ground water can also be utilized as a heat source, however this necessitates a heat exchanger, which is installed in-between. Brine in 3 way valve Heating water flow In the evaporator the heat pump gives off its energy to the refrigerant, which evaporates and is subsequently compressed in the compressor. The refrigerant, the temperature of which has now been raised, is passed to the condenser where it gives off its energy to the heating circuit and if necessary to the water heater tank. The installed cartridge heater lies behind the condenser, which is automatically activated at higher energy demand Brine pump Brine out Evaporator Cooling unit Condenser Compressor Expansion valve Heating water return Immersion heater Heating water pump Technical Data FIGHTER 1220 Type FIGHTER 1220-5 8 11 6 8 10 12 Recorded capacity* (B 0 /W 35) kw 1.0 1.8.5 1.3 1.7.0.5 Emitted capacity* (B 0 /W 35) kw 4.8 8.3 11.5 6,4 8,2 10.0 11.7 COP at B 0/W 35.6.7.5 5.0 5.0 5.0.7 Hot water tank capacity litres 160 Double-jacket tank volume litres 5 Necessary headroom for installation mm 1745 without adjustable feet (30 50 mm)/1890 mm Width mm 600 Depth mm 625 Net weight kg 280 85 00 05 10 Operating voltage V 0(1-phase+Zero) 4 00(3-phase+Zero) Integrated cartridge heater (factory installed) kw 6 (6) 9 (6) Refrigerant R407C * In accordance with EN 255 for cooling medium entry at 0 C / hot water flow at 35 C. The electric input for the circulation pumps is not included. Design specifications for different heat sources Type FIGHTER 1220-5 8 11 6 8 10 12 Borehole depth for ground probe** m 70 90 140 170 160 190 90 110 120 140 140 170 160 190 Ground heat, hose length** 00 300 400 2x300 2x250 2x350 250 400 325 2x250 400 2x300 2x250 2x350 Heating medium flow l/s 0.10 0.19 0.31 0.13 0.18 0.22 0.26 Brine flow l/s 0.25 0.53 0.65 0.35 0.48 0.58 0.65 * Specifications relative to 100% Q N with 1800 operating hours hot water at 450 m above sea level. ** Stated values are only approximate guide values, specifications for surface collector with PE-Rohr 40 x 2,3. 9

Heat pump with the soil, bedrock or groundwater FIGHTER 1320 The heat pump consists of two units which contain less than 3 kg refrigerant per unit. The two compressors, which are activated when they are needed, achieve a higher output control by increased operation intervals, which leads to less wear and increased operational safety. FIGHTER 1320 enables simultaneous production of heating water and hot water. The production of hot water is prioritised by the activation of one or both compressors. FIGHTER 1320 is constructed in such a manner, that the compressors and refrigerant circuits are encased in separate units, which ensures safe servicing. This double sound-proofing of the compressors results in very low noise levels. Circulation pumps and flexible hoses are fitted at the factory. Cooling medium and heating circuits are connected on the back of the device. Dirt filters are included in the delivery. FIGHTER 1320 is a heat pump for heating larger buildings such as multi-family houses and large scale industrial plants. Soil, brine or ground water can be used as an energy source. FIGHTER 1320 is a flexible product with advanced control equipment which offers a multitude of system solutions. FIGHTER 1320 can run at two different flow temperatures if necessary with double heat curves. It is furthermore prepared for controlling an oil-fuelled or electric boiler. This heat pump can be controlled in a heating system as either a master or slave. FIGHTER 1320 is manufactured in four versions; these feature an output of 23, 29, 34 or 40 kw. Due to the two highly effective piston compressors* in a refrigerant circuit of suitable size, the Fighter 1320 achieves a high efficiency. With an heat factor (COP) of at least 4.5 ** with an incoming cooling medium temperature of 0 C and an outgoing heating medium temperature of 35 C, the unit is an effective cost saver. The FIGHTER 1320 is fitted with a microprocessor to ensure optimal and safe operation. Clear information on condition, operation time and all temperatures can be read off from the LCD display. External plant thermometers are therefore not necessary. FIGHTER 1320 features a robust frame with a strong outer casing. Effective sound-proofing guarantees low noise levels and therefore increased living comfort. Detachable front and side panels make the installation and servicing easier. Nine FIGHTER 1320 can be connected together via a control unit to achieve an output of up to 360 kw. It is also possible to cool via brine on hot summer days. FIGHTER 1320 can be installed in different ways (see page 12 13). Necessary accessories would be for example the room sensor RG 10 or the equipment for hot water control VST 11, the temperature signal distributor T 10 and other equipment. * (Scroll compressors in the 40 kw model) **(excluding circulation pumps) 10

as the heat source Contents of delivery (see page 12) Accessories (see page 13) FIGHTER 1320 Dirt filter R32 resp. R40, R25 Temperature sensor with plug contact External sensor Tubes for sensors Aluminium tape Insulating tape Hoses and seals (WQA-flow R25 inner and outer threads) Heat transfer paste Connection hoses with seals Safety valve Immersion heater IU Switchbox K11 3 kw 6 kw (with thermostat and thermal overload protection) Hot water control VST 11 Three-way valve with copper pipe Ø28 (maximum recommended charging capacity is 15 kw) Hot water control VST 20 for higher capacity Room sensor RG 10 Room thermostat RT 10 Level switch NV10 Technical data FIGHTER 1320 Type FIGHTER 1320-20 25 30 40 Power consumption* (B 0 /W 35) kw 4.9 (2 x 2.45) 6.2 (2 X 3.1) 7.5 (2 x 3.75) 9.0 (2 x 4.59) Heating capacity* (B 0 /W 35) kw 23.3 (2 x 11.65) 29.3 (2 x 14.65) 34.0 (2 x 17) 40.4 (2 x 19.9) COP at B 0/W 335.8.7.5.5 Height mm 1580 (without adjustable feet 30 50 mm) Width mm 600 Depth mm 625 Net weight kg 330 5 0 50 Voltage V 00(3-phase+Zero) Refrigerant R407C * In accordance with EN 255 for cooling medium entry at 0 C / hot water flow at 35 C. The electric input for the circulation pumps is not included. Climate system FIGHTER HPAC HPAC is an accessory that turns the FIGHTER 1120 and FIGHTER 1320 NIBE brine/water heat pumps into complete climate systems. In the winter the heat pump extracts thermal energy from the heat source and heats the house via the fan convectors. When there is less need for cooling, brine from the cold ground probe circulates through the fan convectors and passively cools the house. However on hot days the heat pump starts and actively cools the fan converter by delivering the available thermal energy to the ground probe system. This results in effective cooling of the house while at the same time charging the ground probe system for winter days. HPAC provides the most economic and environmentally friendly, total solution for heating, comfort cooling as well as hot water production. Instead of fan convectors, cooling blankets, air coolers for ventilation systems etc. can be connected for cooling. L E K 11

Kontrollera att vatten finns i pannan innan Cirk.pump Värmepump Varmvatten Tillsatsvärme Larm 1 0 R Heat pump with the soil, bedrock or groundwater UG FIGHTER 1320 docked with heating boiler and hot water tank HR EXP PG Panna Boiler SV-P VXV FG RG T Radiator flow Radiator return (floating condensing) The FIGHTER 1320 prioritises filling of hot water with half output (heat pump module B) via the three-way valve (VXV). When the hot water tank/accumulator tank (VPA) is full, the three-way valve (VXV) controls against the heating circuit. At heating demand first module A starts. At increased demand module B also starts for heating. The boiler is switched on automatically, when the energy demand exceeds the capacity of the heat pump, and the mixing valve (SV) is activated, when the temperature of the heating boiler (PG) exceeds 55 C. KB-ut KB-in B A RV BV RV BV HR VVG IU VVB VPA / ACK VVB When the hot water tank/accumulator tank is fitted with a cartridge heater (IU) and a switchbox (K11), the function additional hot water can be used. We recommend using a contactor which can be bypassed. The accessories VST 11, IU and K11 are necessary for this option. Abbreviations Shutoff valve BV Check valve VVB Hot water tank ACK Accumulator tank Dirt filter VVC PG FG VVG Safety valve Hot water circulation Boiler sensor Flow sensor Hot water sensor UG RG HR VXV Outdoor temperature sensor Return temperature sensor Auxiliary relays/contactor withbypass Changeover valve SV-P KB-in KB-ut RV A Check valve Cooling medium - inlet Cooling medium - outlet Control valve Heat pump module A B EXP VPA IU Heat pump module B Expansion vessel with the necessary safety equipment Accumulator tank with hot water tank Cartridge heater Contents of delivery (see page 5, 8 and 11) 8 NIBE Utetemperatur givare Outdoor temperature sensor Aussentemperatur fühler Artikel 01876 8 Dirt filter R25, R32, R40 Insulating tape Temperature sensor with plug contact Aluminium tape External sensor with enclosure Compression joint Level vessel with safety valve Isolated heat source connection pipes Heat transfer paste Anchoring clamps Connection hoses with seals Overload protection EBV 200 12

as the heat source Docking of two or more FIGHTER 1320 with heating boiler and accumulator tank (floating condensing) EXP PG SV-P FG VBP3 RG CP UG HR HR Boiler Oljepanna VVC alternativ 1 VVC alternativ 2 HR 50.0 RV RV BV BV C Va r m v a t t e n t e m p e r a t u r 13.43 RV RV BV BV I II 50.0 C Va r m v a t t e n t e m p e r a t u r 1.0 B 13.43 B VVG P A BV KB-ut BV Slave VP2 EXP A VVC VVC VXV I II 1.0 HR Master VP1 KB-in VVB / ACK VPA VVB / ACK VPA VVB If the compressors cannot maintain the correct flow temperature, the boiler starts. The mixing valve (SV) remains closed until the boiler reaches 55 C. The flow sensor (FG) and the return sensor (RG) must be located on the main pipe to the radiators. FIGHTER 1320 is designed in such a manner, that several units can be connected together to meet high power demands. If there is a heating demand, one of the compressors starts up. If additional heat is needed, a further compressor is started, until the heating demand is met. In order to avoid hot water turbulence in the accumulator tank, a possible hot water circulation connection must be moved to an additional hot water tank (VVB). LE K 52 Accessories 103 20 (see page 5, 8 and 11) 43 85 Level switch NV 10 15 Additional electrical system ETS 12 (3-phase) L 89 18 Kontaktor steg Room thermostat RT 1094 18 Kontaktor steg 1 109 Three-way valve with A H N 01850 Elpatron, 9 kw K 10 DK N H A H IP 44 TF 110 Class H Max. 10bar P/N:59526447 PC;0017NIB motor 31 130 HEJSAN GRUNDFOS 1m(A) P,(W) 0.20 45 0.30 65 0.40 90 Type UPS 25-60 230V50Hz 2.5uF 30 C Room sensor RG 10 K LE K LE 20 LE H 15 98 31 25 EK Hot water control VST 11 018 60 Överhettningsskydd 49 181 6 Driftstermostat LE K K LE VVC alternativ 2 VVC alternativ 1 01999 Elkopplingsplåt 6 36 31 63 81 52 I II C Va r m v a t t e n t e m p e r a t u r 1m(A) P,(W) 0.20 45 0.30 65 0.40 90 Type UPS 25-60 230V50Hz 2.5uF 130 13.43 DK 67 IP 44 TF 110 Class H Max. 10bar 10 P/N:59526447 PC;0017NIB 50.0 5 49 HEJSAN 49 36 19 GRUNDFOS 1.0 50.0 81 81 49 49 VST 20 I II C Va r m v a t t e n t e m p e r a t u r 1.0 13.43 104 B LE P 63 52 Extra shunt ESV 20 0 52 A 49 Slave VP2 85 44 A 49 63 44 63 B K 52 44 5 81 31 44 01850 Elpatron, 9 kw Pool kit Pool 11 2 34 789 1 Cartridge heater with complete contactor set 9kW (1 x 230V 6kW) 63 44 44 Master VP1 52 44 LE K 88 44 95 95 96 13

Water heaters for connection to heat pumps VPA VPA is a range of water heaters intended primarily to be connected to heat pumps. They are also suitable for use with other heat sources. VPA is manufactured in three sizes, 200/70, 300/200 and 450/300. The water heater is made up of a hot water tank, encased by a double jacket of sheet steel. The hot water tank is fitted with copper or enamel corrosion protection on the inside. See table. The water heaters are designed and approved to meet current pressure vessel standards. Due to the polyurethane foam insulation the water heater provides excellent thermal insulation. If necessary VPA enables the use of an immersion heater for sensor controlled hot water heating. The cold water supply line must be fitted with safety equipment in accordance with current standards. If the water heaters are heated to more than 65 C, a mixing valve must be fitted. The highest permitted temperature is 100 C. Technical Data VPA Size 200/70* 300/200** 450/300* Hot water tank capacity litres 205 285 444 Double-jacket tank volume litres 66 194 285 Net weight kg 150 180 285 Height ** mm 1540 1725 2000 Width x Depth/Diameter mm 600 x 610 Ø 725 Ø 800 Heat exchange (55/45 10/45 C) kw 8.2 10.0 14.5 Heat content at 50 C kwh 9.0 12.5 19.1 Corresponding hot water amount (40 C) litres 260 360 560 Maximum cartridge heater length mm 540 580 750 Max. pressure in the double jacket MPa 0,25 0,3 0,25 Max. pressure in hot water tank MPa 1 1 1 * Copper ** Copper or enamel *** Without upper connection pipe 14

I II III A B I II I II A B A B 5 0. 0 C V a r m v a t t e n t e m p. 1. 0 I II III A B I II I II A B A B 5 0. 0 C V a r m v a t t e n t e m p. 1. 0 Exhaust air Module for Ground Heat Pump This is the ideal solution for new buildings, as FLM 30 as well as FLM 40 meets the requirements set out in the Energysaving directive. FLM 30 and FLM 40 are exhaust air modules specially designed to combine recovery of mechanical exhaust air of the heat source in the ground or brine. FLM 30 and FLM 40 are designed to connect to the FIGHTER 1120/1220 or FIGHTER 1320 heat pump type. The built-in fan in FLM 30 and FLM 40 extracts the air from the wet areas of the house to the module. Here the recovered energy is transferred to the heat pump from the ground probe or earth collector. This leads to an increase of the temperature of the heat source and enhances the heating capacity of the heat pump. Even when the heat pump is not in operation, energy is stored in the ground and the exhaust air energy is utilised to the full. The brine/water heat pump capacity is not bound by the amount of air as with an exhaust air heat pump, but the output can be optimally adapted to suit the size of the house. FLM 30 and FLM 40 are best connected directly to FIGHTER 1220, but can also be wall-mounted. FLM 30 FLM 40 40 FLM 30 and FLM 40 can be connected to Extract air Exhaust air FIGHTER 1120/1220/1320 Ø 160 Ø irrespective 160 of output size. A total solution for heat recovery FLM from 40the exhaust air, as well as the increase of the energy levels of the ground or brine. Extract Fortluft air Ø Ø 160 160 Exhaust air Abluft Ø 160 160 FLM 40 30/ FLM 40 The length of the collectors can be optimised. High fan capacity and low sound level. Simple installation. Technical Data Alt. 1 FLM 30 FLM 40 Brine in Brine out HTER 1220 FLM 30 on consoles for FIGHTER 1120. FIGHTER 1220 Wärmequellen-Eintritt Brine Wärmequellen-Austritt Brine out FIGHTER 1220 Height mm 400 400 Width mm 600 600 Depth mm 600 600 Max. air flow approx. m 3 /h 400 400* Max. cooling capacity kw 2,3 2,3* * From June 2006 Alt. 2 FX 110 15

GKB GB 0613-4 Geothermal Climate Systems 639056 Subject to design and dimension changes. NIBE Heating, with its Head Office in Markaryd, Sweden, is one of Europe s leading companies in the domestic heating field. Products such as water heaters, heat pumps and several types of boiler are the basis of NIBE s current product range. NIBE Heating is one of three business areas of NIBE Industrier, a company listed on the Swedish Stock Exchange. NIBE Heating, Markaryd, Sweden www.nibe.com NIBE, Box 14, SE-285 21 MARKARYD, Sweden Tel: +46 - (0)433-73 000, Fax: +46 - (0)433-73 190