Megaflo eco. Unvented hot water cylinders



Similar documents
Megaflo eco. Unvented hot water cylinders

CI/SfB. (53.3) x. August Unvented Water Heaters. PremierPlus. Unvented Hot Water Cylinders

Water Heating Catalogue

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Electric Flow Boiler

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Session 2: Hot Water Supply

StainlessLite. Unvented mains pressure and vented water storage in Duplex stainless steel SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

ECOCIAT. Domestic hot water heat recovery unit

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Light Duty Commercial Electric Water Heater

ECOplus Solar Cylinder

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH7/2.2, AH10/2.2, AH15/2.2

Link-Up. Solid Fuel Association Guide to Central Heating.

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

HOT WATER SYSTEMS.

SOLAR HOT WATER SOLUTIONS stainless steel roof systems

SF15K SF05KSS, SF10KSS

maximise the sun s energy with warmflow solar Warmflow Solar

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

INSTALLATION INSTRUCTIONS FOR ALBION ULTRASTEEL UNVENTED CYLINDERS: DIRECT, INDIRECT AND SOLAR MODELS.

Megalife Vented Cistern Fed Water Heater Installation manual

Solar Hot Water Heaters

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

Unvented water heater

Laddomat Charging unit

High-efficient gas boiler CompactGas

HEAVY DUTY STORAGE GAS

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

Commercial Electric Water Heater

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Unvented water heater

ASME Packaged Indirect Fired Water Heater

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Technical Data Manual Model Nos. and pricing: see Price List

Natural geothermal energy.

building engineering services association specification for: Domestic Heating

Energy to the Power of

Description of functions

OWNER S MANUAL & INSTALLATION GUIDE. Installation Details Owner s Information Warranty. 80L - 400L Electric Storage Water Heaters

UNDERSTANDING CENTRAL HEATING SYSTEMS

Aquatap Plentiful drinking water at the touch of a button

IMPORTANT: PLEASE READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE COMMENCING INSTALLATION.

Daikin Altherma Hybrid Heat Pump

Solar Collector Series. Product List

Elson 10/15L Unvented Water Heater

WC flushing cistern single or dual flush to fill in 2 minutes WC trough cistern 0.15 per WC Wash basin tap size 1 2

Daikin Altherma Hybrid Heat Pump

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

The Worcester Greenstar System Filter. An innovative solution for reducing system contaminants

Daikin Altherma Hybrid Heat Pump

BoilerMate SP. benchmark. user instructions A - C L A S S

R e n e w a b l e s. Tribune HE Unvented Hot Water Cylinders Installation and Maintenance Instructions. Issue 14 May 2011 Part No.

SOLAR HEATING SYSTEMS.

Hot water supply, distribution and use

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS

Solar Hot Water. What systems are available?

IMPORTANT: PLEASE READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE COMMENCING INSTALLATION. PACK CONTENTS

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Building Services Engineering Technician

Morco House Riverview Road Beverley HU17 0LD

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION. For capacities litres

SOLAR WATER HEATER USER AND INSTALLATION MANUAL

WARRANTY BOOKLET. Commercial Water Heaters. Register online at

INSTALLATION INSTRUCTIONS & OWNERS GUIDE

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Response: The combi boiler. Response: The fit anywhere combi

Water supply in tall buildings: roof tanks vs. pressurised systems

AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

ROTEX Solaris: Use the energy of the sun. ROTEX Solaris Solar energy for hot water and heating. The heating!

Solar hot water systems that give energy efficiency a whole new meaning

High Output Boiler Systems

RPV - RP - RA air handling units

INSTALLATION & TECHNICAL MANUAL

SOLAR HOT WATER SOLUTIONS Ground Systems

Thermo Siphon Solar Systems

Making Your Home Ready For Solar Water Heating

Blowdown vessels Meeting the requirements of HSE PM60

Technical data. Danfoss DHP-A

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Endless Hot Water 24/7

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

DIETRISOL SOLAR WATER HEATING SYSTEMS ENERGY SAVINGS AND ECOLOGICAL BENEFITS SUSTAINED COMFORT SIMPLICITY AND RELIABILITY INNOVATIVE, MODULAR SYSTEMS

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza (Spain) Tel.: Fax:

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Vacuum drying oven for non-flammable solvents

Stove-boiler for solid fuels KW Directions for use and assembling

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Direct steam injection humidifiers

Transcription:

Megaflo eco Unvented hot water cylinders

Megaflo eco. etter for you, your customers and your environment. Our Megaflo eco range is the best choice for conserving energy while providing superior performance. How do we guarantee our customers needs the best possible performance, quality and reliability when developing unvented water heating systems? How do we ensure our system provides powerful mains pressure showers and fasterfilling baths and with maximum reliability and efficiency? The answer is simple. We use only the most advanced unvented water heating technology available. nd, where this doesn t meet the standards of performance, efficiency and reliability we insist upon, we develop innovative new technologies of our own to bridge the gap. These advances can come in many forms. Sophisticated Duplex stainless steel cylinder construction for maximum strength and corrosion resistance; CFC / HCFCfree injected foam, encasing the entire system including the bosses and valves, for the best possible heat insulation; a floating baffle system to replace a conventional external expansion vessel for quicker and simpler installation. nd to prove our confidence in this advanced new technology, we provide every new system with a lifetime cylinder guarantee with onsite service support. Then we detail precisely what sets the Megaflo eco apart from everything else Installerfriendly design. Fully indemnified design service. Improved performance at low pressures down to bar. New water inlet controls increase flow rates by up to 0%. Improved insulation for maximum heat retention. Reduction in heat loss of up to 7%. No anode eliminates costly anode maintenance. Insulated casing for the temperature and pressure relief valve to minimise heat loss. Unique Lshaped longlife Superloy immersion heater reaches deeper into the tank giving more hot water. Titanium immersions as standard on all direct models. Patented cold water inlet diffuser minimises mixing of cold and hot water. High performance coilincoil heat exchanger. Exceeds CHeSS * est Practice for recovery times and insulation. Complies with future Energy Related Products Directive. Constructed in Duplex stainless steel for maximum strength pressure tested to 5 bar. Compatible with a wide range of UK solar systems. Second purposedesigned solar coil to ensure maximum heat input and solar efficiency. * Energy Efficiency Partnership: Central Heating System Specifications. Megaflo Specification Hotline: 0 00 0

Innovative technology For domestic and commercial applications Cylinder construction Duplex stainless steel offers a superior resistance to corrosion especially in aggressive water areas, compared with some grades of stainless steel, glasslined steel and copper. ecause Duplex is a low carbon, high chromium content alloy, it resists all forms of corrosion including pitting, crevice corrosion, uniform corrosion and stress corrosion cracking without the use of a sacrificial anode. In addition, the tungsten inert gas welding coupled with the special postweld processes ensures the welded area has the same level of corrosion resistance and mechanical strength as the parent metal. This ensures the longest possible working life for every cylinder. Internal air gap and floating baffle The internal air gap and floating baffle system allows for a compact selfcontained unit which eliminates the need for an external expansion vessel and allows for a quicker and simplified installation. Expanded water is accommodated within the cylinder using an internal air gap maintained by a patented floating baffle. This baffle floats on the surface of the water within the cylinder to maintain the integrity of the air gap. efore expansion fter expansion Floating baffle The combination of its lightweight yet very strong construction makes Megaflo eco easier to handle onsite. Every unit is pressure tested in the factory to 5 bar five times the normal operating pressure making Megaflo eco suitable for all domestic and commercial applications. No sacrificial anode is required with Megaflo eco. With inferior grades of stainless steel, glasslined steel and copper, sacrificial anodes are required to achieve a degree of corrosion resistance. However they require regular replacement which, if not carried out can result in premature cylinder failure. Megaflo eco overcomes any need for this by using top quality Duplex stainless steel. Specification comparison to a copper unit with air gap Typical maximum working pressure Typical operating pressure Material Megaflo 0 bar bar Duplex stainless steel Copper.5 bar bar Copper 0 Megaflo Specification Hotline: 0 00 Megaflo Specification Hotline: 0 00 05

Commanding performance Minimal heat loss Thermal imaging Improved efficiency To minimise heat loss, a mm thick voidfree layer of highperformance polyurethane foam fills the Using thermal imaging cameras the benefits of Megaflo eco s minimal heat loss design are easily seen. Coilincoil heat exchanger Cold water inlet diffuser space between the inner vessel and outer casing for maximum insulation efficiency and compliancy with future Europeanwide legislation. The images show the relatively low levels of heat loss from Megaflo eco compared to traditional cylinders in the high heat radiating areas of the immersion heater Unlike other designs which rely on butt jointing of boss and temperature and pressure relief valves. sheet materials, Megaflo eco s carefully moulded onepiece insulation cannot separate in transit thus Traditional cylinder Megaflo eco ensuring its effectiveness is maintained. Megaflo eco is supplied with an innovative casing which insulates the temperature and pressure relief valve. The base is fully insulated and the unit stands on three moulded feet to minimise heat loss to the supporting floor. Immersion heaters and controls Exposed immersion heater Integrated immersion heater With high output ratings from 5. to.5kw and The patented cold water inlet diffuser reduces are fully integrated with no large external bosses to a highly efficient transfer of energy, Megaflo eco turbulence to minimise the mixing of cold and radiate heat. indirect offers very fast heat recovery times. hot water. Furthermore, the heating coil and L shaped This ensures that the heated water remains hot and immersion heater are positioned low in the cylinder therefore maximises the usable hot water delivered to ensure more of the water is heated to maximise by Megaflo eco. Exposed temperature and pressure relief valve Insulated temperature and pressure relief valve the usable hot water available. Heat loss levels High Low 06 Megaflo Specification Hotline: 0 00 Megaflo Specification Hotline: 0 00 07

System benefits In addition to the performance benefits of fast filling baths and powerful showers, unvented hot water systems offer many features and benefits over other types of hot water systems. Flexible siting Unlike traditional vented systems, there is no requirement for a cistern tank in the loft, giving users a quiet hot water system. Installation locations are also flexible, so the cylinder can be installed in an airing cupboard, loft, cellar, utility room or even in a garage. Loft Garage iring Cupboard Cellar End user Specifier / developer Installer Features and benefits Higher flow rates for efficient hot water delivery High performance showering throughout the home Fastfilling baths Quieter mains pressure system (no noisy cistern in the loft) alanced water pressure no surprises Patented cold water inlet diffuser minimises mixing of cold and hot water Exceeds CHeSS * est Practice for heat recovery Fast recovery rates (eg. 5 minutes for 5i unit) CFC / HCFC free (ODP zero) insulation and insulated temperature and pressure relief valve for maximum heat retention No fear of frozen loft pipes ** No anode to check or replace Mainsfed hygienic hot water ppliance quality, easyclean finish Longlife Duplex stainless steel interior Lifetime cylinder guarantee Patented internal expansion system No external expansion vessel Complete with mains water isolating valve Flexibility in cylinder siting ** Dry roof space increases design options Cost effective installer friendly connections No reduction in operating pressure or flow rates Supplied with safety and hot water controls, wiring centre for indirect models and drain valve No cold feed cistern to install for the hot water supply Neater and quicker installation Easy to commission No costly shower pump to install Lightweight, installer friendly design Stronger construction for durability and high pressure performance ll units fully factory tested to ensure reliability Fully indemnified design service *Energy Efficiency Partnership: Central Heating System Specifications. **ssumes sealed system boiler with Megaflo eco in frostfree position. ssumes no loft conversion. Conditions apply. 08 Megaflo Specification Hotline: 0 00 Megaflo Specification Hotline: 0 00 09

Megaflo eco Installer friendly design Megaflo eco has been designed to facilitate a troublefree installation. Compact and rounded in design, with all connections accessible at the front of the unit. Megaflo eco s lightweight construction means it s easy to handle and convenient to site almost anywhere in a building. Strong feet for additional stability. ll plumbing connections are colour coded and accessible at the front of the cylinder. Lightweight construction. Drain valve supplied loose with every cylinder. ase moulding with integral hand grips. Detachable lifting handle. Key product features 9 Construction High performance Internal air gap to accommodate expanded water. Patented floating baffle maintains the air gap. mm compression / ¾" SP hot water outlet. Cylinder manufactured from top grade Duplex stainless steel specially selected for its high strength and resistance to stress and crevice corrosion. 5 6 7 Totally insulated with 00% CFCfree (ODP zero) polyurethane to minimise heat loss (mm thick). Longlife kw Superloy 85 immersion heater with integral thermostat and thermal cutout. Titanium elements as standard on all direct models. Drain valve. 5 mm compression / ¾" SP cold water inlet. 8 Wiring centre for indirect controls (i models only). 6 ase mouldings with integral hand grips. 7 mm compression / ¾" SP primary flow. 8 mm compression / ¾" SP primary return. 9 Primary heating coil for use with indirect systems (i models only). 0 Patented cold water diffuser. White plasticcoated, corrosionproofed outer case with grey moulded top and bottom covers and electrical housings for neat and attractive finish. Grommets on pipework for professional finish. 5mm connection for secondary return (supplied capped) indirect models only. Safety controls 9 ½" temperature and pressure relief valve (supplied with innovative insulation casing supplied loose) operating at 90ºC / 0 bar. 0 Indirect thermal controls. 8 7 6 0 5 9 5 6 Indirect model shown 0 7 8 0 Megaflo Specification Hotline: 0 00 Megaflo Specification Hotline: 0 00

Megaflo eco systemfit Installer friendly design This timesaving Megaflo eco systemfit package not only speeds installation but significantly enhances the quality and integrity of the central heating system, thus eliminating costly call backs. Strong feet for additional stability. ll plumbing connections are colour coded and accessible at the front of the cylinder. Lightweight construction. Factoryfitted drain valve. ase moulding with integral hand grips. Detachable lifting handle. 9 0 6 Key product features Separate Central Heating & Hot Water Configuration Safety controls Motorised valve to radiator circuit mm on 5 and 5 litre models. 8mm on other models. mm motorised valve to Megaflo eco coil heat exchanger. Wiring centre. Programmable thermostat and room sensor with timed Domestic Hot Water (DHW) Control. 5 Hot water temperature thermostat. 6 ½" temperature and pressure relief valve (with innovative insulation casing supplied loose) operating at 90ºC / 0 bar. 7 Tundish. 8 High limit hot water thermal cutout. Connections 9 Primary flow connection from boiler mm on 5 and 5 litre models. 8mm on other models. 7 8 5 6 7 0 7 High performance configuration 0 Discharge pipe connection mm. 6 utomatic bypass valve. 7 speed circulator pump with quality isolating valves. 8 alancing valve. 9 piece inlet control kit consisting of: bar pressure reducing valve 8 bar pressure relief valve Stopcock. 0 Combined expansion valve / check valve housing. mm or ¾" SP hot outlet to taps. mm primary flow to Megaflo eco coil heat exchanger. mm primary return from Megaflo eco coil heat exchanger. Cold water inlet connection mm. Primary flow to radiators (CH circuit). 8mm connection for nd CH zone (supplied capped) litre and above only. 5mm connection for secondary return (supplied capped). 5 uto air vent. 6 Primary system pressure gauge. 7 Primary system filling loop. 8 Primary system expansion vessel. 9 Primary circuit return connection. 6 9 5 5 8 Drain cocks. 9 8 5 Longlife kw Superloy 85 immersion heater with integral thermostat and thermal cutout. Megaflo Specification Hotline: 0 00 Megaflo Specification Hotline: 0 00

Megaflo eco pplications and installation Megaflo eco Performance Which unit to use High usage applications When it comes to meeting the needs of demanding applications, e.g. rugby club shower rooms, two or more Megaflo eco units can be installed in parallel. Detailed specifications and designs, including comprehensive plumbing information, are available by contacting our Specification dvice Team on tel: 0 00, by fax: 0 09 or by email: enquiries@megafloeco.com Commercial installation examples pplication Indirect Direct Typical parallel installation Illustration showing two Megaflo eco units in parallel for high usage applications. Diagram for illustrative purposes only bespoke pipework required for specific applications. Hot outlet Discharge pipe must terminate at a viable, safe place Cold inlet Megaflo eco s pressure and flow rate performance will exceed those available from comparable vented systems, thermal store units, multipoint instantaneous gas heaters or combination boilers. It offers flexibility in cylinder siting as it can be positioned in any convenient location that allows a suitable routing of the discharge pipe from its safety valve. It should not be installed in areas that are subject to freezing. Outlet flow from cold water combination valve (I/min) Inlet flow to cold water combination valve (l/min) 0 0 0 0 bar static pressure bar static pressure bar static pressure bar static pressure 6 bar static pressure 0 0 0 0 0 8 0 0 0 0 Recovery times for indirect models with various boiler outputs based on % recovery oiler output (kw) 8.8 0.5.7..7 6. 7.6 9. 0.5..9 6. oiler output (tu) 0k 5k 0k 5k 50k 55k k 65k k 75k 80k 85k 90k i cylinder 8 6 6 8 9 9 0 5 7 8 9 0 50 0 6 7 0 0 7 5 9 5 56 0 8 9 5 57 6 0 80 0 5 57 6 66 0 90 5 6 7 0 Nursing home (7 beds) Student accommodation (8 showers) Sports club ( showers) Rugby club (max. 80 showers per hour) House (5 bed & 5 bath) ar with food servery (00 persons) Hotel (8 bed & 6 bath) Guest house ( bath & shower) x 00i 6x 0i (x ) x 50i x 00i x 00i x 5i x 50DDD 6x 00DDD (x ) Note: These example recommendations are for guidance only, the Megaflo Specification dvice Team should be contacted to discuss requirements and designs for specific sites. Typical installation of a Megaflo eco indirect cylinder To hot outlet Secondary return tapping T&P valve alanced cold water connection bar pressure reducing valve Stop cock 8 bar pressure relief valve Tundish Megaflo eco unvented water systems deliver hot water at flow rates up to 7 litres per minute and offer one of the most rapid heat up and recovery rates available, making it ideally suited to a wide variety of applications. vailable in seven capacities, ranging from to 00 litres, in both direct and indirect systems, there is a model to suit every environment. 5i cylinder 5i cylinder i cylinder 0i cylinder 50i cylinder 00i cylinder 7 5 6 75 9 9 8 56 67 6 9 0 9 57 Megaflo eco cylinder performance Nominal capacity (litres) i (indirect) Recovery D (direct kw) Heat up 5 9 6 5 DD (direct 6kW) Heat up 9 7 9 6 8 0 5 0 5 DDD (direct 9kW) Heat up 7 9 6 9 6 9 0 6 6 9 8 DDDD (direct kw) Heat up 6 9 6 6 9 5 8 DD & DDD oost heat top element 6 9 0 8 6 9 0 8 Heat loss in hours (kwh) Which cylinder to use pplication edsit bed bath & shower bed bath & shower bed bath & shower Indirect i 5i 5i 5i Direct D 5DD / 5DD 5DD / DD 0DD Primary return Primary flow Drain cock Discharge pipe 5 5 0 50 00 0 5 7 6 9 7 9 58 86 0 5 9 7 79 9 0 6 68 8 97 5 7 66 7 79 85 9 97 0.9.9...57.67.89 bed bath & shower /5 bed bath & shower i 0i 0DD 50DD Installer training In addition to the lower kw heating element which is fitted to all indirect models, the 0i, 50i and 00i have the facility to also have an upper boost element fitted. This boost element is available as an accessory. /5 bed bath & shower Light commercial uses Other commercial uses 50i 50i 00i 00DD 50DDD / 50DDDD 00DDD / 00DDDD 50DDD / 50DDDD 00DDD / 00DDDD pproved courses are available nationwide for operative training. For further details of such courses, call 085 0. Figures are for guidance only and are based on S 60 recommendations. D = one element, DD = two elements, DDD = three elements, DDDD = four elements, i = Indirect with one element supplied. Megaflo Specification Hotline: 0 00 Megaflo Specification Hotline: 0 00 5

Dimensions and ordering Megaflo eco Dimensions and ordering Megaflo eco systemfit Megaflo eco indirect Ordering guide Nominal capacity i Element rating @0V (kw) x Coil rating (kw) 5. Weight empty full (kg) (kg) 5 5 Product code 95:050:6 Megaflo eco systemfit 90 00 Ordering guide 5sf S Nominal capacity 5 Element rating @0V (kw) x Coil rating (kw) 8. Weight empty full (kg) (kg) 8 Product code 95:050:8 5i 5 x 8. 80 95:050:6 00 5sf S 5 x 8.7 8 08 95:050:8 5i 5 x 8.7 5 0 95:050:65 sf S8 x. 5 95:050:9 F F G G E E D D C C 7.0 7.0 7.0 7.0 0.0 5.0 0.0 5.0 7.0 7.0 i 0i 50i 00i D 5DD 0 50 00 5 x x x x x x...9.5 8 5 5 55 00 58 58 5 7 95:050:67 95:050:69 95:050:7 95:050:75 95:050: 95:050:6 D C 0 0sf S8 50sf S8 00sf S8 0 50 00 x x x..9.5 55 5 6 97 69 5 95:050:9 95:050:95 95:050:96 Optional boost element available for 0 to 00 units. For a Titanium Indirect Control and Immersion Heater ccessory Pack, order product code 95:9:55. Megaflo eco direct 5DD DD 5 x x 00 8 95:050:6 95:050:66 G G D D C C 0.0 0.0 5.0 5.0 7.0 7.0 0DD 0DDD 0DDDD 50DD 50DDD 50DDDD 00DD 00DDD 00DDDD 0 0 0 50 50 50 00 00 00 x x x x x x x x x 8 8 0 5 5 6 96 8 98 50 00 56 55 58 58 95:050:68 95:050:80 95:050:76 95:050: 95:050:7 95:050:77 95:050:7 95:050:7 95:050:78 Cylinder dimensions 5sf S 5sf S sf S8 0sf S8 50sf S8 00sf S8 80 0 C 896 D 5 07 0 997 6 6 56 0 0 98 768 8 86 0 5 07 0 676 Cylinder dimensions i 5i 5i i 0i 50i 00i D 5DD 5DD DD 0DD / 0DDD 50DD / 50DDD 00DD / 00DDD / 00DDDD 80 C 95 D 5 E 6 F 9 80 9 G 9 0 9 8 86 78 05 79 895 00 095 57 5 5 5 5 5 5 6 6 6 6 6 6 9 9 9 0 9 8 9 56 9 80 0 9 8 86 78 95 79 895 00 095 08 08 08 08 08 08 75 75 75 75 75 75 05 57 08 75 ccessory ordering guide Description Titanium Indirect Control and Immersion Heater ccessory Pack For 0 Litre and above a further Indirect Control ssembly accessory is available 95:9:55 Product code 95:9:55 6 Megaflo Specification Hotline: 0 00 Megaflo Specification Hotline: 0 00 7

Megaflo eco solar Installer friendly design Developed to our exacting performance and reliability standards, the Megaflo eco solar technology provides up to % annual hot water requirement by solar energy. * Lightweight construction. Choice of direct or indirect auxiliary heat input. Strong feet for additional stability. ase moulding with integral hand grips. Specially designed solar coil for maximum solar efficiency. Remote expansion vessel. 7 ll plumbing connections are colour coded and accessible at the front of the cylinder. Drain valve supplied loose with every cylinder. Factoryfitted control pockets suitable for insertion of solar controller and temperature control probe. Detachable lifting handle. Cylinder manufactured from top grade Duplex stainless steel specially selected for its high strength and resistance to stress and crevice corrosion. Totally insulated with 00% CFCfree (ODP zero) polyurethane to minimise heat loss (mm thick). High flow rates for improved hot water delivery. Megaflo eco solar models are compatible with a wide range of UK solar systems. Equally suited for new build or refurbishment projects. Environmentally friendly reduced carbon emissions. Lower running costs and reduced energy bills. Fully indemnified design service. Lifetime cylinder guarantee with onsite service support. Cylinder capacities sized to ensure sufficient hot water on days of limited solar gain, offering the correct choice when specifying for uilding Regulations ** via SP. *** 9 0 5 Key product features Construction High performance 5 6 7 8 mm compression / ¾" SP hot water outlet. mm compression / ¾" SP cold water inlet. Integral feet. mm compression / ¾" SP primary flow (solar). mm compression / ¾" SP primary return (solar). Patented cold water diffuser. White plasticcoated, corrosionproofed outer case with grey moulded top and bottom covers and electrical housings for neat and attractive finish. Grommets on pipework for professional finish. 9 Longlife kw Superloy 85 immersion heater with integral thermostat and thermal cutout. 0 Titanium elements as standard on all direct models. Wiring centre for indirect controls. dditional solar probe pocket. Drain valve. Safety controls ½" temperature and pressure relief valve (supplied with innovative insulation casing supplied loose) operating at 90ºC / 0 bar. 5 8 5 Indirect thermal controls. * This is an average figure for the year, with savings varying depending on the type of solar system used, its location and usage pattern. ** Part L (England and Wales), Section 6 (Scotland) and Part F (Northern Ireland). *** Standard ssessment Procedure for Energy Rating of Dwellings. 6 8 Megaflo Specification Hotline: 0 00 Megaflo Specification Hotline: 0 00 9

Megaflo eco solar pplications and installation Which unit to use The choice of capacity for traditional cylinders is based on the hot water requirements of the dwelling. With solar cylinders the usable hot water will vary due to a number of factors such as siting of solar panels, time of year and weather conditions. For this reason, when choosing a solar cylinder you should ensure that sufficient usable hot water will be available during winter months where solar gain is at its lowest. Megaflo eco solar typical indirect installation Collector Solar pump station and controller Solar cylinder Domestic hot water oiler Cold mains feed Indirect cylinder No. of beds or 5 No. of baths / showers Max. occupancy or 5 or 5 5 Onroof panels Inroof panels Tube 0 0 0 0 0 0 0 Cylinder volume 90 0 50 50 00 00 00 Dedicated solar 90 05 05 5 5 5 Onroof (l/m ) 8 9 9 9 Inroof (l/m ) 9 6 7 7 7 Tube (l/m ) 5 5 5 5 Max. property size (m ) 95 6 6 6 uxiliary volume 0 0 5 5 75 75 75 For example a nonsolar dwelling of three inhabitants with a bath and a shower would normally require a 5 litre indirect cylinder. portion of the cylinder capacity must be dedicated to solar only, therefore the same dwelling with a solar system would require a 50 litre indirect solar cylinder which would provide 5 litres of hot water during periods where there is little or no solar gain. Some applications may require larger water quantities or higher recovery rates, therefore it is important to calculate the hot water requirement before selecting the cylinder capacity. Direct cylinder No. of beds No. of baths / showers Max. occupancy 5 Onroof panels Inroof panels Tube 0 0 0 0 0 0 0 Cylinder volume 0 0 00 00 Dedicated solar 90 90 00 00 Onroof (l/m ) 8 8 9 8 8 Inroof (l/m ) 0 0 Tube (l/m ) 5 5 5 5 Max. property size (m ) 95 95 Onroof absorber area.8; in roof absorber area.8; tube absorber area.00. ll cylinders are SP compliant provided the maximum property size is not exceeded. uxiliary volume 00 0 0 00 00 0 Megaflo Specification Hotline: 0 00 Megaflo Specification Hotline: 0 00

Megaflo eco solar Performance Dimensions and ordering Megaflo eco solar Megaflo eco solar s pressure and flow rate performance will exceed those available from comparable vented systems, thermal store units, multipoint instantaneous gas heaters or combination boilers. It offers flexibility in cylinder siting as it can be positioned in any convenient location that allows a suitable routing of the discharge pipe from its safety valve. It should not be installed in areas that are subject to freezing. Megaflo eco solar unvented water systems deliver hot water at flow rates up to 7 litres per minute and offer one of the most rapid heat up and recovery rates available, making it ideally suited to a wide variety of applications. vailable in six capacities, ranging from to 00 litres, in both Megaflo eco solar cylinder performance Nominal capacity (litres) 90Si 0Si 50Si 00Si SD 0SDD SDD 00SDD Si (indirect) Recovery.5.5 0 9 SD (direct kw) Heat up 6 SDD (direct 6kW) Heat up 75 89 0 DD & DDD oost heat top element Heat loss in hours (kwh)...56.8.5..6.8 In addition to the lower kw heating element which is fitted to all indirect models, the 0i, 50i and 00i have the facility to also have an upper boost element fitted. This boost element is available as an accessory. Megaflo eco solar indirect F F C Megaflo eco solar direct 7.0 7.0 7.0 7.0 0.0 0.0 5.0 5.0 7.0 7.0 C 7.0 7.0 E D E D Ordering guide Nominal capacity 90Si 0Si 50Si 00Si SD 0SDD SDD 00SDD axi Solarflo 0 0 5 75 0 0 00 Element rating @0V (kw) x x x x Coil rating (kw) 8 8 8.7.5 Weight empty full (kg) (kg) 5.5 5.5 7.5 57.5 56.5 06.5 66.5 66.5 7.8 07.8.5 5.5 7. 07. 6.5 6.5 Product code 95:050:5 95:050:5 95:050:55 95:050:57 95:050:57 95:050:5 95:050:58 95:050:56 direct and indirect systems, there is a model to suit every environment. E 0.0 0.0 5.5 5.5 Cylinder dimensions 90Si 0Si 50Si 00Si SD 0SDD SDD 00SDD 87 C 00 D E 7 F 95 89 78 05 8 78 69 7 095 7 58 7 57 9 89 80 05 95 8 69 7 7 7 7 The Megaflo eco solar cylinders are ideal companions for the axi Solarflo system. Onroof, inroof, flat roof solar collector and evacuated tube packages available. Reduces CO emissions and domestic fuel bills. National technical support and after sales service from a single source. Megaflo Specification Hotline: 0 00 Megaflo Specification Hotline: 0 00

Full specifications Megaflo eco / systemfit Full specifications Megaflo eco solar Cylinder specification Installation Systemfit components Cylinder specification Installation Capacities Megaflo eco, 5, 5,, 0, 50 and 00 litre. Capacities Megaflo eco systemfit 5, 5,, 0, 50 and 00 litre. Rating Immersion heater(s) kw @ 0V. Up to four are fitted dependent on model. Outer casing White plasticcoated corrosionproofed steel. Thermal insulation CFC/HCFCfree (ODP zero) flameretardant expanded polyurethane (mm thick). GWP. (Global Warming Potential). Water container Duplex stainless steel with internal airgap system. Pressure testing To 5 bar. Heat unit Longlife Superloy 85 alloy sheathed element(s), incorporated into an easily removable heater plate, should replacement be necessary. Rated kw @ 0V. Titanium immersion as standard on all direct models and available as an accessory on indirect models. Primary coil mm diameter stainless steel. Thermostat Direct models: Element thermostat adjustable from C to 68 C. Indirect models: Factoryfitted cylinder thermostat adjustable from ºC to 68 C. Capillarytype thermostats now used on all models. Factoryfitted safety features Direct models: Manually resettable cutout on heating element operates at 85 C. Indirect models: High limit thermal cutout operates at 90 C. Wired in series with twoport motorised valve (supplied) to provide primary over temperature protection. ll models: Temperature and pressure relief valve, factory set to operate at 0 bar and 90 C (insulation casing supplied loose). Wiring centre for indirect controls (supplied loose). node Not required. pprovals Nemko and Kiwa approved, CE marked. Manufactured in the UK in a S EN ISO 900:008, ISO 00:00 and S OHSS 800:007 registered factory. Must be installed by a competent installer in accordance with Local Regulations. England and Wales uilding Regulations G. Scotland Technical Standards P. N. Ireland uilding Regulations P5. Fixing uiltin feet for floor mounting. Plumbing Inlet / outlet: ¾" SP male parallel and mm compression fittings supplied. Indirect coil: ¾" SP male parallel and mm compression fittings supplied. ½" temperature and pressure relief valve: 5mm compression outlet supplied. Cold water control Cold water control mm HiFlo cold water valve assembly comprising bar pressure reducer, ¼ turn isolating ball valve, line strainer, nonreturn valve and expansion valve (8 bar). Cold water control valve ( bar) is supplied for use with mains pressure of 0 bar to.5 bar, at the lower pressure, performance will be reduced accordingly. Normal working pressure is bar. mm cold water inlet control kit comprising of 8 bar pressure relief valve, bar pressure reducing valve and stopcock which enables the Megaflo eco to be isolated from the mains supply for maintenance and servicing. The bar pressure reducing valve can be installed as a complete one piece unit or incorporated into the stopcock. Water expansion Via air gap built into the top of the cylinder. The patented floating baffle maintains the air gap. Flow rates Up to 7 litres per minute (depending on adequate supply conditions). Minimum water supply requirements 0 litres per minute flow and.5 bar pressure (at lesser values, the unit will operate but outlet flow rates may be unacceptable, especially with multiple drawoffs). Please contact our Specification dvice Team to discuss specific site conditions if the above minimum requirement cannot be met. Secondary circulation ½" SP female connection provided (circulating pump not supplied). Secondary circulation is not recommended for units using offpeak electrical elements for auxiliary heating. Compatible boilers Gas, electric or oilfired sealed system or open vent type, fitted with integral control thermostat and thermal cutout. Tundish Megaflo eco 5mm inlet and mm compression outlet. Tundish Megaflo eco systemfit 5mm inlet and mm compression outlet factoryfitted. Electrical Connection is direct to terminals in the immersion heater which must be permanently connected to the supply through a doublepole linked isolating switch with a minimum breaking capacity of. On indirect models, controls should be wired to the boiler, programmer etc. in accordance with the control scheme being used. ll electrical installations must conform to the latest IEE Wiring Regulations. Danfoss TP9000 Programmable Room Thermostat with Domestic Hot Water (DHW) Control. uilt in hot water time control. Remote room temperature sensor. Chronoproportional control on / off. Frost protection setting. Easy to use overrides. Up to 6 time / temperature changes per day. 7 day, 5 / or hour operation. Wallplate construction. Room temperature control range from 5ºC to 0ºC. Holiday mode. Programmer dimensions: Width 5mm, height 88mm, depth mm. Sensor dimensions: Width 6mm, height 5mm, depth mm. Designed to meet S EN7 and EN9. Maximum ambient temperature: 5ºC. Timing accuracy: ± minute. Switch rating: 0 Vac, 50 / Hz, (). Switching action: x SPDT, type S. Power supply: 0Vas, 50H. Memory back up retained for life of product. Honeywell twoport valve: For the central heating and domestic hot water. no.: V0H. Voltage rating: 0V ac 50Hz. Power consumption: 6W. Primary water temperature range: from 5ºC to 88ºC. Max ambient temperature: 50ºC. utomatic bypass valve: no.: RWC Diff 9 90. Working pressure: 0 bar. Setting range: 0. to 0.5 bar differential pressure. Maximum primary water temperature: 0ºC. Pump: : Grundfos UPS5. Working pressure: 0 bar max. Voltage rating: 0V ac 50Hz. Starting capacitor: µf. Power consumption: Speed setting I 0W. Speed setting II 65W. Speed setting III 95W. Enclosure protection: IP. Capacities 90, 0, 50 and 00 litre indirect., 0, and 00 litre direct. Immersion heater ratings x kw @ 0V indirect models and litre direct. x kw @ 0V direct models above litre. Outer casing White plasticcoated corrosionproofed steel. Thermal insulation CFC/HCFCfree (ODP zero) flameretardant expanded polyurethane (mm thick). GWP. (Global Warming Potential). Water container Duplex stainless steel. Pressure testing To 5 bar. Heat unit Longlife Superloy 85 alloy sheathed element(s), incorporated into an easily removable heater plate, should replacement be necessary. Rated kw @ 0V. Titanium immersion as standard on all direct models and available as an accessory on indirect models. Primary coil (For auxiliary boiler heating) mm diameter stainless steel. Coilincoil design for improved performance. Solar coil 5mm diameter stainless steel. Coilincoil design and large surface area for improved performance. Thermostat Direct models: Element thermostat adjustable from C to 68 C. Indirect models: Factoryfitted cylinder thermostat adjustable from ºC to 68 C. ll models: Factoryfitted control pocket suitable for insertion of solar controller temperature probe. Factoryfitted safety features Direct models: Manually resettable cutout on heating element operates at 85 C. Indirect models: High limit thermal cutout operates at 85 C. Wired in series with twoport motorised valve (supplied) to provide primary overtemperature protection when using the auxiliary (boiler) coil. ll models: Temperature and pressure relief valve, factory set to operate at 0 bar and 90 C. Factoryfitted thermal cutout for integration into a solar circuit. node Not required. pprovals Nemko and Kiwa approved, CE marked. Manufactured in the UK in a S EN ISO 900:008, ISO 00:00 and S OHSS 800:007 registered factory. Must be installed by a competent installer in accordance with Local Regulations. England and Wales uilding Regulations G. Scotland Technical Standards P. N. Ireland uilding Regulations P5. Fixing uiltin feet for floor mounting. Plumbing Must be installed by a competent installer in accordance with Local Regulations. England and Wales uilding Regulations G. Scotland Technical Standards P. N. Ireland uilding Regulations P5. Inlet / outlet: ¾" SP male parallel and mm compression fittings supplied. Indirect primary coil: ¾" SP male parallel and mm compression fittings supplied. ½" T&P relief valve: 5mm compression outlet supplied. Solar coil: ¾" SP male parallel and mm compression fittings supplied. Cold water control Cold water control mm HiFlo cold water valve assembly comprising bar pressure reducer, ¼ turn isolating ball valve, line strainer, nonreturn valve and expansion valve (8 bar). Cold water control valve ( bar) is supplied for use with mains pressure of 0 bar to.5 bar, at the lower pressure, performance will be reduced accordingly. Normal working pressure is bar. mm cold water inlet control kit comprising of 8 bar pressure relief valve, bar pressure reducing valve and stopcock which enables the Megaflo eco solar to be isolated from the mains supply for maintenance and servicing. The bar pressure reducing valve can be installed as a complete one piece unit or incorporated into the stopcock. Water expansion Via remote 5 litre expansion vessel (supplied). Flow rates Up to 7 litres per minute (depending on adequate supply conditions). Minimum water supply requirements 0 litres per minute flow and.5 bar pressure (at lesser values, the unit will operate but outlet flow rates may be unacceptable, especially with multiple drawoffs). Please contact our Specification dvice Team to discuss specific site conditions if the above minimum requirement cannot be met. Secondary circulation ½" SP female connection provided (circulating pump not supplied). Secondary circulation is not recommended for units using off peak electric elements for auxiliary heating. Compatible boilers Gas, electric or oilfired sealed system or open vent type, fitted with integral control thermostat and thermal cutout. Tundish 5mm inlet and mm compression outlet. Electrical Each immersion heater must be permanently connected to the electrical supply through a doublepole linked switch with a minimum breaking capacity of. The indirect thermal controls should be wired into a suitable indirect control system to ensure optimum control of the Megaflo Solar and auxiliary boiler. The solar coil must be connected to a fully pumped solar primary system that should be controlled by a suitable solar controller and hydraulic set. The solar controller cylinder temperature sensor must be inserted in the pocket supplied on the heater. The solar thermal cutout (factoryfitted) should be wired in series with the solar controls (not supplied). ll electrical work must conform to current IEE wiring regulations. Megaflo s Specification dvice Hotline is available to discuss requirements for specific projects, applications and product selection on Tel: 0 00. Megaflo Specification Hotline: 0 00 Megaflo Specification Hotline: 0 00 5

Guarantee WRNING: Should the factoryfitted temperature and pressure relief valve be tampered with or removed your guarantee will be invalidated. Neither the Distributor nor Manufacturer shall be responsible for any consequential damage howsoever caused. Megaflo guarantees the Megaflo eco against faulty manufacture or materials for a period of two years from the date of purchase including parts and labour. This two year guarantee is extended to five years for the cold water inlet control kit and to lifetime* for the stainless steel inner vessel in domestic properties and to 0 years for the stainless steel inner vessel in commercial buildings. The Megaflo eco systemfit components, immersion heater and thermal controls are guaranteed for a period of years from the date of purchase. 5 years for the cold water inlet control kit and systemfit primary expansion vessel. The Megaflo eco solar expansion vessel comes with a 5 year guarantee. These guarantees are valid provided that: The Megaflo eco has been correctly installed by a competent installer and as per the instructions contained in the Product Guide and all relevant Codes of Practice and Regulations in force at the time of installation. For installations outside of the United Kingdom, please contact either the Heatrae Sadia Heating Export Department on Tel: + 07 for further details of the guarantee terms and conditions applicable. This guarantee does not affect your statutory rights. The unit is not guaranteed against damage due to frost. This guarantee does not affect your statutory rights. *Lifetime is defined as for as long as the original owner who purchased the Megaflo eco / New Home continues to own the property. If the owner sells the property, the new owner (and any future owners) will receive a 0 year warranty from the time the original owner purchased the Megaflo eco or new property with Megaflo eco installed. ny disinfection has been carried out in accordance with S 60. The Megaflo eco has not been modified in any way other than by Heatrae Sadia Heating or Heatrae Sadia Heating approved engineers. The Megaflo eco has only been used for the storage of wholesome water (max. 50mg/l chloride). The Megaflo eco has not been subjected to frost, scaling, nor has it been tampered with or been subjected to misuse or neglect. No factoryfitted parts have been removed for unauthorised repair or replacement. The enchmark Commissioning Checklist and Service Record included in the Megaflo eco Product Guide has been completed. Regular maintenance has been carried out by a competent person in accordance with the requirements set out in the maintenance section of the Product Guide and any replacement parts used should be authorised Heatrae Sadia Megaflo eco spare parts. nnual Services are available from heateam, the service division of Megaflo. Please contact heateam on Tel: 08 87 55 for further details. Within days of purchase the owner registers the product via telephone, email or completes the guarantee form supplied with the Megaflo eco. Evidence of purchase and date of supply must be submitted upon making a claim. It has been installed in the UK. This guarantee is not valid for installations outside the United Kingdom. 6 Megaflo Specification Hotline: 0 00 Megaflo Specification Hotline: 0 00 7

heateam is Megaflo s very own service division. With us on your side, you can be sure that your customers are in the very best hands. Totally committed to quality and safety, heateam is open 7 days a week, for 6 days a year, and offers: Dedicated Trade dvice Line our helpful and qualified specialists are always on hand to help you with even the most complex technical query. Installer Priority CallOuts our 80 strong team of specifically trained expert heating engineers covers the UK, no one is better qualified to look after Megaflo s products for the duration of the guarantee. Fully Stocked Vans a nationwide fleet of vans, fully stocked with spare parts meaning we can repair our appliances on the first visit in 95% of callouts. Exclusive Service Plans heateam also offer Megaflo s customers a range of exclusive annual service plans. Opening Times: MondayFriday 8am6pm, weekends and ank Holidays* 8.0ampm * excluding Christmas Day and New Year s Day. Simply call 08 8755 Or visit our website at www.heateam.co.uk Products wide range of Megaflo eco cylinders are currently available and further lines are in development. Please contact Megaflo or your nearest stockists for further details. These include: Unvented Indirect and direct Unvented Indirect systemfit Unvented Indirect and direct solar Contact Specification dvice Hotline Tel: 0 00 Fax: 0 09 enquiries@megaflo.com www.megafloeco.com Servicing Tel: 08 87 55 megafloservice@heateam.co.uk Consumer Website www.megaflo.com Megaflo, Hurricane Way, Norwich, Norfolk NR6 6E. 95 900 807 Issue 9 Megaflo 0 Megaflo may introduce modifications to their products from time to time. Consequently, the details given in this brochure are subject to alteration without notice. PN 95 900 807 JN 080 FCN 9/0