ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01



Similar documents
ABB Drives. User s Manual HTL Encoder Interface FEN-31

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

X8 Option 2 - Technology

Allen-Bradley/Rockwell

Description. Dimensions. Features. precision works better

Modular I/O System Analog and Digital Interface Modules

ACS800. Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program

DMX2PWM 9 Channel Dimmer Setup Manual

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

Installation and Start-up Guide. CS 31 Adapter Module NCSA-01

Smile 11 AS-i Emergency stop with safe AS-i input node

MILE Encoder for EC 90 flat

Original instructions Tina 3A/Aps Adaptor unit

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Agilent AEDB-9140 Series Three Channel Optical Incremental Encoder Modules with Codewheel, 100 CPR to 500 CPR Data Sheet

Three Channel Optical Incremental Encoder Modules Technical Data

Tina 2A/B Adaptor unit

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Absolute Rotary Encoder E6CP

PCS0100en Persy Control Services B.V. Netherlands

SV 210 Signal Splitter and Incremental Converter for Sine-Cosine Encoders

QR12 (1.22 ) Diameter Optical Encoder

ServoOne. Specification. Option 2 - Technology. x 11. x 8 X 8. x 10. x 9. x 7. x 6 TTL Encoder / TTL Encoder simulation

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Small Optical Encoder Modules 480lpi Digital Output. Features. Applications VCC 3 CHANNEL A 2 CHANNEL B 4 GND 1

The quadrature signals and the index pulse are accessed through five inch square pins located on 0.1 inch centers.

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

How To Power A Schen

Digital input modules

Advantium 2 Plus Alarm

Contents. Document information

HEDS-9000/9100 Two Channel Optical Incremental Encoder Modules. Features. Applications

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

IRT Eurocard. Types DAX-3200

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

ABB general machinery drives. User s manual ACS355 drives

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

EXTERNAL DIMENSIONS AND PARTS

Multi-Protocol decoder with Load regulation

TECHNICAL DATASHEET Incremental Encoder RI 80-E

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Addendum to the Operating Instructions

Disturbance Recoder SPCR 8C27. Product Guide

Series 7500 Torque Sensor

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

3M Wrist Strap and Footwear Tester 740. User s Guide

Safety Manual BT50(T) Safety relay / Expansion relay

Duct Humidity Transmitter

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

IO-DIM6 6-Channel, Digital to Analogue Converters

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps

3 740 Wrist strap + shoe tester

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

ACS 800. Supplement Traverse Control Application Program 7.x

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

GREISINGER electronic GmbH

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

ZC-24DO CANopen I/O Module: 24 Digital Outputs

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Kvaser Mini PCI Express User s Guide

Operating Manual UWAPS-TINY Series

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

DK40 Datasheet & Hardware manual Version 2

Analog Servo Drive 25A8

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Achat 115MA full-range speaker. user manual

Operation Manual. Plasma torch height controller. Model: Compact THC Controller 150

Voltage Regulator SPAU 341 C. Product Guide

MDC Series

Optocoupler, Phototransistor Output, with Base Connection

Allen-Bradley/Rockwell

ABB machinery drives. User s manual ACS355 drives

User manual Rev. 1.2 (17/04/2015)

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Safety Relays ESM/ESM-F

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

SIMADYN D Digital Control System. Interface module SE21.2. User Manual. Edition DK-Nr

MINI MCR-SL-R-UI(-SP)

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

BITMAIN. APW PSU Series User Guide

Brushless DC Motor Controller Product Specification Assembly 025F0129

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

SYSTEM 4C. C R H Electronics Design

A1000 Cheat Sheet (Open Loop Vector)

Number 1 in efficiency

RS - SPM. Serial parallel translator module

Fiber Optics. Integrated Photo Detector Receiver for Plastic Fiber Plastic Connector Housing SFH551/1-1 SFH551/1-1V

Transcription:

ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0

Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved.

Safety instructions Overview General safety instructions This chapter states the general safety instructions that must be followed when installing and operating the RAIO-0 Analogue I/O Extension module. The material in this chapter must be studied before attempting any work on, or with, the unit. In addition to the safety instructions given below, read the complete safety instructions of the specific drive you are working on. WARNING! All electrical installation and maintenance work on the drive should be carried out by qualified electricians only. The drive and adjoining equipment must be properly earthed. Do not attempt any work on a powered drive. After switching off the mains, always allow the intermediate circuit capacitors 5 minutes to discharge before working on the frequency converter, the motor or the motor cable. It is good practice to check (with a voltage indicating instrument) that the drive is in fact discharged before beginning work. The motor cable terminals of the drive are at a dangerously high voltage when mains power is applied, regardless of motor operation. There can be dangerous voltages inside the drive from external control circuits even when the drive mains power is shut off. Exercise appropriate care when working on the unit. Neglecting these instructions can cause physical injury or death. RTAC-0 User s manual iii

Safety instructions iv RTAC-0 User s manual

Table of contents Safety instructions Overview..................................................... iii General safety instructions........................................ iii Table of contents Chapter Introduction Intended audience............................................ - Before you start.............................................. - What this manual contains...................................... - Chapter Overview Overview................................................... - The RTAC-0 module......................................... - Module layout.............................................. - Delivery check............................................. - Compatibility............................................... - Warranty and liability information............................... - Chapter 3 Installation Mounting................................................... 3- Terminal designations......................................... 3- Power consumption........................................... 3-3 Encoder wiring............................................... 3-5 Phasing................................................... 3-6 Encoder output types........................................ 3-7 Wiring diagrams............................................ 3-8 Node address selection....................................... 3- Programming............................................... 3- RTAC-0 User s manual v

Table of contents Chapter 4 Fault tracing Diagnostic LEDs.............................................. 4- Option slot installation...................................... 4- I/O Module Adapter installation............................... 4- Appendix A Technical data vi RTAC-0 User s manual

Chapter Introduction Intended audience Before you start The manual is intended for the people who are responsible for commissioning and using an RTAC-0 Pulse Encoder Interface module with the ACS 800 drive. The reader is expected to have a basic knowledge of electrical fundamentals, electrical wiring practices and how to operate the drive. It is assumed that the drive is installed and ready to operate before starting the installation of the extension module. In addition to conventional installation tools, have the drive manuals available during the installation as they contain important information not included in this manual. The drive manuals are referred to at various points of this document. RTAC-0 User s manual -

Chapter Introduction What this manual contains This manual contains information on the wiring, configuration and use of the RTAC-0 module. Safety instructions are featured in the first few pages of this manual. Chapter Overview contains a short description of the RTAC-0 Pulse Encoder Interface module, a delivery checklist and warranty information. Chapter 3 Installation contains instructions for module hardware settings, mounting and cabling. Chapter 4 Fault tracing explains fault tracing and the LED indications of the RTAC-0 module. Appendix A contains technical data. - RTAC-0 User s manual

0 8 Chapter Overview Overview The RTAC-0 module This chapter contains a short description of the Pulse Encoder Interface module, a delivery checklist, and warranty information. The RTAC-0 Pulse Encoder Interface module offers an interface for a digital pulse encoder connection. A pulse encoder should be used if accurate speed or position (angle) feedback from the motor shaft is required. Module layout Node ID selector (S) 4 6 Fixing screw (GND) Diagnostic LEDs 3 5 CHASSIS RTAC-0 PULSE ENCODER INTERFACE GND SHLD F E D C B 7 A 9 SHLD CHA CHA+ CHB WD/ INIT X NODE ID CHA- CHB+ CHB- CHZ+ CHZ- X V OUT +5V V IN +4V Fixing screw (CHASSIS) Terminal block for encoder signals (X) Terminal block for encoder power connections (X) 3 4 5 6 7 8 3 4 5 6 RTAC-0 User s manual -

Chapter Overview Delivery check Compatibility Warranty and liability information The option package contains: RTAC-0 module Encoder supply voltage selection jumper Two screws (M3 8 mm) This manual. The RTAC-0 is compatible with ACS 800 Standard Application Program version ASXR7000 or later. The warranty for your ABB drive and options covers manufacturing defects. The manufacturer carries no responsibility for damage due to transport or unpacking. In no event and under no circumstances shall the manufacturer be liable for damages and failures due to misuse, abuse, improper installation, or abnormal conditions of temperature, dust, or corrosives, or failures due to operation above rated capacities. Nor shall the manufacturer ever be liable for consequential and incidental damages. The period of manufacturer's warranty is months, and not more than 8 months, from the date of delivery. Extended warranty may be available with certified startup. Contact your local distributor for details. Your local ABB Drives company or distributor may have a different warranty period, which is specified in their sales terms, conditions, and warranty terms. If you have any questions concerning your ABB drive, contact your local distributor or ABB Drives office. The technical data and specifications are valid at the time of printing. ABB reserves the right to subsequent alterations. - RTAC-0 User s manual

Chapter 3 Installation WARNING! Follow the safety instructions given in this guide and in the ACS 800 Hardware Manual. Mounting The RTAC-0 is to be inserted into the position marked SLOT or SLOT on the drive. The module is held in place with plastic retaining clips and two screws. The screws also provide the earthing of the I/O cable shield connected to the module, and interconnect the GND signals of the module and the RMIO board. On installation of the module, the signal and power connection to the drive is automatically made through a 38-pin connector. The module can alternatively be mounted on a DIN railmountable AIMA-0 I/O Module Adapter (not available at the time of publication). Mounting procedure:. Insert the module carefully into SLOT or SLOT on the RMIO board until the retaining clips lock the module into position.. Fasten the two screws (included) to the stand-offs. Note: Correct installation of the screws is essential for fulfilling the EMC requirements and for proper operation of the module. RTAC-0 User s manual 3-

Chapter 3 Installation Terminal designations X Marking Description Encoder power supply, either 5 or 4 V DC (according to jumper selection on terminals 4, 5 and 6). ( is also used with single-ended encoder connection 3 V OUT for balancing the A+, B+ and/or Z+ conductors. See Figures 3-3 to 3-6.) 4 5 +5V V IN Encoder supply voltage selection: Terminals 4 and 5 connected: 5 V (default) Terminals 5 and 6 connected: 4 V 6 +4V (Jumper is supplied with the RTAC module) Max. 5 watts (see Power consumption below) Connected internally on the circuit board. X Marking Description SHLD SHLD Shield For earthing of the encoder cable shields. Internally connected to the frame. 3 4 A+ A- A A Max. signal frequency: 00 khz Signal levels: > 7.6 V, 0 < 5 V (for 5 V supply) 5 B+ B >. V, 0 < 8 V (for 4 V supply) Input channels isolated from the logic, power supply, 6 B- B and earth When the drive runs in the Forward direction, 7 Z+ Z channel A should lead channel B by 90 (electrical) 8 Z- Z Channel Z: One pulse per revolution (used in positioning applications only) 3- RTAC-0 User s manual

Chapter 3 Installation Power consumption Without an external power supply, the RTAC-0 can supply 5 W (at either 5 V or 4 V DC) to the encoder. For higher power, an external power supply is required. As the power consumption of the module depends on many factors (e.g. max. speed of the motor, encoder pulse number per revolution, encoder cable length and leakage capacitance), it should be checked on each occasion if an external power supply is needed. See the encoder documentation for details. Figure 3- shows the approximate power consumption of an encoder with differential outputs, based on actual measurements. The external power supply should be connected as shown below. Note: With an external power supply, the voltage selection jumper should be removed from X. RTAC X 0V V cc 0V V cc 3 4 V OUT +5V 5 V IN 6 +4V X SHLD Figure 3- External power supply connection diagram RTAC-0 User s manual 3-3

Chapter 3 Installation Encoder power consumption P idle +.0 W Cable length 300 m P idle +.75 W P idle +.5 W 50 m P idle +.5 W 00 m P idle +.0 W P idle + 0.75 W P idle + 0.5 W P idle + 0.5 W 0 m P idle EPN = 04 ppr: EPN = 048 ppr: EPN = 5 ppr: 0 300 600 900 00 500 800 00 400 700 3000 0 50 300 450 600 750 900 050 00 350 500 0 600 00 800 400 3000 3600 400 4800 5400 6000 Motor speed (rpm) EPN = Encoder pulse number P idle = Encoder power consumption when idle. See encoder documentation. Figure 3- Approximate power consumption of an encoder for four different cable lengths. The chart is based on a measurement with a 4 V DC, 04 ppr pulse encoder with differential outputs coupled to a motor shaft rotating at 500 rpm. 3-4 RTAC-0 User s manual

Chapter 3 Installation Encoder wiring The pulse encoder should be connected to the RTAC module with a cable specified below. Cable construction Conductor crosssectional area Maximum cable length 4 (+) Twisted pair cable with individual and overall shields. 0.5 to.0 mm Dependent on encoder output type as follows: 300 m (differential push-pull) 00 m (single-ended push-pull) 00 m (open collector or emitter) Either a single-ended or differential connection can be used, but the manufacturer s recommendations should be taken into account. Starting on page 3-8, there are wiring diagrams for different encoder output types. Compare encoder documentation and the diagrams below to determine the output type. Note: The cable shields should be earthed at the RTAC module only if the encoder is not isolated from the motor and earth. However, if the encoder is isolated from the motor and earth, the cable shields are to be connected to the encoder housing also. Note: Do not route the encoder cables parallel to power (eg. motor) cables. RTAC-0 User s manual 3-5

Chapter 3 Installation Phasing When the encoder is connected correctly, running the drive in the Forward (positive speed reference) direction should produce a positive encoder speed feedback. On incremental encoders, the two output channels, usually marked and or A and B, are 90 (electrical) apart from each other. When rotated clockwise, most encoders but not all have channel leading channel as illustrated below. Determine the leading channel by referring to the encoder documentation or by measuring with an oscilloscope. A or A or B or B or Z or 0 Z or 0 The encoder output channel that leads when the drive runs Forward should be connected to RTAC input A, the output channel that trails to RTAC input B. The zero reference output channel (usually marked 0, N or Z) needs to be connected in positioning applications only. 3-6 RTAC-0 User s manual

Chapter 3 Installation Encoder output types The diagram presents some typical encoder output types. The following pages include wiring diagrams for each output type. Push-pull Open collector (Sinking) Open emitter (Sourcing) V CC V CC V CC V CC V CC R L R L OUT OUT OUT R L R L V CC = Encoder input power supply voltage R L = Load resistor at encoder output channel RTAC-0 User s manual 3-7

Chapter 3 Installation Wiring diagrams Encoder output type: Push-pull Output pulse order in Forward rotation:, (With encoders with as the leading output, and should be wired to RTAC terminals B+ and A+ respectively. and should be wired to RTAC terminals B- and A- respectively.) Differential connection RTAC X VCC 0V 0 0 3 4 5 6 7 8 SHLD SHLD A+ A- B+ B- Z+ Z- X Encoder supply voltage selection (5 or 4 V) 4V 5V 3 4 5 6 V OUT +5V V IN +4V Figure 3-3 Differential wiring of pulse encoders with push-pull outputs 3-8 RTAC-0 User s manual

Chapter 3 Installation Single-ended connection Encoder output type: Push-pull Output pulse order in Forward rotation:, (With encoders with as the leading output, and should be wired to RTAC terminals B+ and A+ respectively. and should be wired to RTAC terminals B- and A- respectively.) RTAC X VCC 0V 0 3 4 5 6 7 8 SHLD SHLD A+ A- B+ B- Z+ Z- X Encoder supply voltage selection (5 or 4 V) 4V 5V 3 4 5 6 V OUT +5V V IN +4V Figure 3-4 Single-ended wiring of pulse encoders with push-pull outputs RTAC-0 User s manual 3-9

Chapter 3 Installation Encoder output type: Open collector (Sinking) Output pulse order in Forward rotation:, (With encoders with as the leading output, and should be wired to RTAC terminals B+ and A+ respectively) RTAC X VCC 0V 0 3 4 5 6 7 8 SHLD SHLD A+ A- B+ B- Z+ Z- 4V:.8. kω 5V:.0.5 kω 0.5 W X Encoder supply voltage selection (5 or 4 V) 4V 5V 3 4 5 6 V OUT +5V V IN +4V Figure 3-5 Wiring of pulse encoders with open collector (sinking) outputs. 3-0 RTAC-0 User s manual

Chapter 3 Installation Encoder output type: Open emitter (Sourcing) Output pulse order in Forward rotation:, (With encoders with as the leading output, and should be wired to RTAC terminals B+ and A+ respectively) RTAC X VCC 0V 0 3 4 5 6 7 8 SHLD SHLD A+ A- B+ B- Z+ Z- 4V:.8. kω 5V:.0.5 kω 0.5 W X Encoder supply voltage selection (5 or 4 V) 4V 5V 3 4 5 6 V OUT +5V V IN +4V Figure 3-6 Wiring of pulse encoders with open emitter (sourcing) outputs. RTAC-0 User s manual 3-

Chapter 3 Installation Node address selection Programming If the RTAC-0 module is mounted onto external I/O Module Adapter AIMA-0, choose the proper node ID for the module using the node ID selector (S). The settings 0 F correspond to node IDs 6 3. The default setting is 0 (node ID 6). Setting the node ID is not required when the module is mounted into SLOT or SLOT on the drive. The RTAC-0 is programmed through drive parameters. These parameters must be checked and adjusted. For further information, see the drive Firmware Manual, Parameter Groups 50 and 98. 3- RTAC-0 User s manual

Chapter 4 Fault tracing Diagnostic LEDs Option slot installation I/O Module Adapter installation There are three diagnostic LEDs on the RTAC-0 module. The CHA (green) and CHB (green) LEDs show the activity on channels A and B. The WD/INIT (yellow) LED shows the status of the module. WD/INIT is lit when the drive is configuring the module at power-up. In case the LED does not go out after one second: The configuration has failed. - Cycle the power supply of the drive. The module has a hardware failure. - Ensure the 38-pin connector is properly inserted. - Contact an ABB service representative. There is no communication with the drive. - Check that the drive is powered. - Check the module node ID. - Check that the fibre optic cables are connected correctly (transmitters to receivers) and the connectors properly inserted. - Check the fibre optic cables visually for dirt or flaws. - Ensure the 38-pin connector is properly inserted. - Try new fibre optic cables. - Contact an ABB service representative. RTAC-0 User s manual 4-

Chapter 4 Fault tracing 4- RTAC-0 User s manual

C 4 Appendix A Technical data Dimensions: 34 mm CHASSIS RTAC-0 PULSE ENCODER INTERFACE GND 95 mm 3 4 5 6 7 8 3 4 5 6 SHLD SHLD CHA+ CHA- CHB+ CHB- CHZ+ CHZ- V OUT +5V V IN +4V X X CHA CHB WD/ INIT NODE ID B E D A 9 F 0 8 7 3 5 6 0 mm 6 mm Mounting: Into an option slot of the RMIO board of the drive or onto external I/O Module Adapter (AIMA-0). Degree of protection: IP 0 Ambient conditions: The applicable ambient conditions specified for the drive in its Hardware Manual are in effect. Hardware settings: Rotary switch for node ID selection (range 6 3) Connectors: 38-pin parallel bus connector Two (one 6-pole, one 8-pole) non-detachable screwtype terminal blocks for max..5 mm wire. RTAC-0 User s manual A-

Appendix A Technical data Encoder interface: CH A, CH B, CH Z, differential or single-ended Output voltage : +4 V DC ±0%, 5 W max., shortcircuit proof Output voltage : +5 V DC ±0%, 5 W max., shortcircuit proof Signal levels: "" >7.6 V, "0" < 5 V (for 5 V supply) "" >. V, "0" < 8 V (for 4 V supply) Frequency: 00 khz (max.) Speed feedback resolution: 0.00305% (5 bits) Speed feedback accuracy: 50 ppm Maximum encoder cable length: - 300 m (differential push-pull) - 00 m (single-ended push-pull) - 00 m (open collector or emitter) Isolated from the logic and earth. Test voltage:.5 kv AC, minute General Max. power consumption: 40 ma (5 V) + 55 ma (4 V) Estimated min. lifetime: 00 000 h All materials UL/CSA-approved Complies with EMC standards EN 5008- and EN 5008- A- RTAC-0 User s manual

RTAC-0 3AFE 64486853 REV A EN EFFECTIVE:.5.00 ABB Oy AC Drives P.O. Box 84 FIN-0038 Helsinki FINLAND Telephone:+358 0 000 Fax: +358 0 68 Internet: www.abb.com ABB Inc. Drives & Power Products 650 West Glendale Drive New Berlin, WI 535 USA Telephone:6 785-8378 800 43-4384 Fax: 6 780-535