CUKUROVA GENERATOR SYSTEMS



Similar documents
CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

PM734F - Technical Data Sheet Winding 28

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

UCI274C - Technical Data Sheet

UCI274H - Technical Data Sheet

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

BCI184E - Technical Data Sheet

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Diesel Generating Set

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

Annex-A TECHNICAL SPECIFICATION

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

DIESEL GENERATOR SETS

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

Spark-ignited generator set

Diesel Engine Driven Generators Page 1 of 6

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

C18 ACERT Fire Pump Tier bkw/ rpm

Diesel Generator Set Model DFHC 60 Hz

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

How To Control A Power Command Powerplant

Atlas Copco Generators

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

Diesel Generator Set Model DFMB 60 Hz

Marine Generating Sets 3.7 to 50 kva

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

A Single Source for all Power System Solutions

Diesel Generator Set Model DGDK 60 Hz

Magnum Mobile Generator MMG55 Specifications

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

STAMFORD Product Guide

How To Use A Cat Diesel Engine

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

IGSA POWER GENERATION SYSTEMS

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

APS100 Rental Generator Set Specification

Technical Specification. Generating Set with Waukesha engine burning natural gas

C18 Diesel Oilfield Generator Set

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

STANDBY 3200 ekw 4000 kva 50 Hz 1500 rpm Volts

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

Specifications for Volkswagen Industrial Engine

The Yachtmans Choice...

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

ECOCIAT. Domestic hot water heat recovery unit

1013 E. The engine for agricultural equipment.

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

TECHNICAL SPECIFICATIONS FOR DIESEL GENERATORS 15KVA (CANOPY TYPE)

OPTIONAL FEATURES 30

The kva RAnge

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

Generators TEM. for small hydroelectric power stations. Electric Machines

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

3516 Industrial Engine

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

CREATING POWER SOLUTIONS. 2L41C 3L41C 3L43C 4L41C 4L42C 4L43C. Hatz Diesel.

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Oil and Coolant Circulating Heating System. Model - OCSM

Unit 96: Marine Propulsion Power Plant

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

912. The engine for construction equipment.

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

Power Generation. Power Control PCL System Generator Set Control

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

SELECTION, APPLICATION AND MAINTENANCE

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

3516B Offshore Generator Set

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

3790 en / d. Alternators LSA Pole. Electrical and mechanical data

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Cooking at the Speed of light!

Transcription:

Diesel Generator CUKUROVA GENERATOR SYSTEMS 1500 Rpm, 50Hz, 400V Perkins 4008TAG2A diesel engine Stamford HCI634J alternator Standard Generator Features AMF, Automatic mains failure unit Heavy duty type, 8 cylinder, water cooled engine 52 C tropical type radiator Starter motor Lead acid battery Charging alternator Battery charge redressor Heavy duty, brushless type alternator Base frame with anti-vibration units Industrial type silencers Flexible exhaust compensator Block water heater unit Control panel with digital-automatic main control module Fan, fan drive, charging alternator drive and all rotating parts covered Radiator matrix covered by metal mesh against the mechanical damages Fabricated and welded steel base frame Anti-vibration mountings Engine and alternator manufacturer test reports Factory load, performance and function tests Optional Features ISO 9001:2000 Cukurova is a fully accrediated ISO 9001:2000 company This generator is available with CE certification Automatic load transfer panel Automatic syncronization and power sharing systems Soundproof canopy Container type enclosers Road trailer Job-site trailer Protection circuit breaker Air start Remote type radiator Base fuel tank External type fuel tank Automatic fuel transfer system Residential silencer Standby Prime kva kw kva kw Cukurova is accrediated with Gost certification 1110 888 1024 819 Technical Data Sheet 061130 - Page1

CUKUROVA Diesel Generator engine APPLICATION DATA Perkins 4008TAG2A Engine Standard Features Economic power Individual four valve per cylinder heads give optimised gas flows, whilst digitally governed unit fuel injectors ensure ultra fine fuel atomisation and hence controlled rapid combustion, for efficiency and economy Commonality of components with other engines in the 4000 Series family allows reduced parts stocking levels Reliable power Developed and tested using latest engineering techniques Piston temperatures are controlled by an advanced gallery jet cooling sys. All engines are tolerant of a wide range of temperatures without derate Service is provided by the extensive Perkins network of over 4.000 distributers and dealers worldwide Clean, efficient power Exceptional power to weight ratio and compact size for easier transportation and installation New designed radiator assembilies with corrosion inhibiting powder coated surfaces; fewer pipe joints and easier access to reduce maintenance times Designed to provide excellent service access for easy of maintenance Engines designed to comply with major international standards Low gaseous emissions for cleaner operation Standards UK MOD, BS5750, ISO9001, BS5514/1-1982, ISO 3046/1, ISO 8528/1 Technical Specifications Manufacturer PERKINS 4008TAG2A 4 cycle, water-cooled, diesel engine Number of cylinders 8 Cylinder arrangement Vertical in-line Displacement, Liters 30.561 Bore X Stroke, mm 160 X 190 Compression Ratio 13.6:1 Combustion System Direct injection Aspiration Turbocharged, air-to-air charge cooled Rotation Anti-clockwise viewed on flywheel Gross engine power, kwb 985 Fan Power, kwm 38 BMEP gross, bar 25,4 Combustion air flow, m³ / min 80,5 Exhaust gas temp.(after turbo), C 465 Exhaust gas flow (after turbo),m³ / min 200 Mean piston speed, m / s 9,5 Cooling System Standby kw Prime kw Gross Net Gross Net 4008TAG2A 985 947 899 861 Lubricating System Pressurized Lub.oil capacity sump min., Liters 127 Lub oil temp. Max to bearings, C 105 Lub oil pressure (at 80 C,min), MPa 0.34 Wet sump with filler and dipstick Engine jacket water/lub oil temperature stabiliser Full-flow spin-on oil filters Fuel System of injection system Direct injection Fuel injection pump Combined unit injector Fuel injector opening pressure, bar 234 Delivery/hour at 1500rev/min, Liters 660 Fuel lift pump Tuthill TCH 1-054 Governor type Electrionic Unit fuel injectors with lift pump and hand stop control Electronic governor to ISO 3046 Part 4class A1 Full flow spin-on fuel filters Electrical System Alternator 24 Volt with integral regulator Starter motor (DC) 24 Volt Starter motor power 8.2 kw Combined high coolant temperature / low oil pressure switch Overspeed switch and magnetic pick up Turbine inlet temperature shutdown switch Fuel Consumption liters per hour grams per kwh %110 Load %100 Load %75 Load %50 Load %110 Load %100 Load %75 Load %50 Load 248 L 220 L 160 L 108 L 214 g/kwh 208 g/kwh 202 g/kwh 205 g/kwh Optional Equipments Ambient temperature, C Engine coolant capacity, Liters Engine+Radiator coolant cap., Liters Jacket coolant flow, Liters / sec Cooling min airflow, m³ / min Gear driven circulating pump Twin thermostats Crankshaft pulley for fan drive Tropical, heavy duty type 52 48 149 10 1350 (at 50 C) Instrument panel Twin heavy duty air cleaner - paper element with pre-cleaner Changeover lubricating oil filter Changeover fuel oil filter Immersion heater with thermostat Air starters Technical Data Sheet 061130 - Page2

alternator Stamford HCI634J Alternator Standard Features Winding&Electrical Performance All generator stators are wound to 2/3 pitch.this eliminates triplen (3rd, 9th, 15th...) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads.the 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains.a fully connected damper winding reduces oscillations during paralelling.this winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion. MX321 AVR This sophisticated Automatic Voltage Regulator(AVR) is incorporated into the Stamford Permanent Magnet Generator(PMG) system and is fitted as standard to generators of this type. The PMG provides power via the AVR to the main exciter, giving a source of constant excitation power independent of generator output. The main exciter, output is then fed to the main rotor, through a full wave bridge, protected by a surge suppressor. The AVR has in built protection against sustained over - excitation, caused by internal or external faults. This de- excites the machine after a minimum of 5 seconds. Over voltage protection is built-in and short circuit current level adjustments is an optional facility Terminals&Terminal Box Standard generators feature a main stator with 6 ends brought out to the terminals, which are mounted on the frame at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements.it has removable panels for easy access. Shaft&Keys All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. Insulation / Impregnation The insulation system is class 'H' All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. Standards Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevent section of other international standards such as BS5000,VDE0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359 Other standards and certifications can be considered on request Quaility Assurance Generators are manufactured using production procedures having a quaility assurance level to BS EN ISO 9001. Frequency, Hz 50 Temperature Indication RTD s Winding Protection Thermistors Manuel Voltage Regulator kva kw kva kw Manufacturer NEWAGE / STAMFORD HCI634J 4-Poles, Rotating Field, Brushless Standby power at rated voltage, kva 1110 Efficiency, % 94.8% Power factor 0.8 Phase 3 Speed, Rpm Voltage, V Excitation Stator windings Regulation Stamford HCI 634 J Technical Specifications Voltage Regulator Rotor Overspeed, Rpm Short circuit current TIF Insultion class Construction Coupling Stator winding Connection Protection class 1110 Standby 1500 Voltage Regulation, % ± 0.5 Quadrature Droop kit for Parallel Operation Self excited 2/3 Pitch factor IP23 Cooling air volume,m³ / sec 1.614 AVR, Automatic Voltage Regulator 2250 < 300% Less than 50 H Double layer concentric WYE Prime R.F.I Suppression BS EN 61000-6-2 & BS EN 61000-6-4 VDE0875G, VDE 0875N Waveform distortion No Load <1.5% Non distorting balanced Optional Equipment Power Factor Controller Diode Failure Unit Air Condensation Heaters Air Filters Excitation Loss Module 380/415 MX321 888 1030 824 linear load<5.0% Dynamic balanced Single bearing, direct coupled Flexible Technical Data Sheet 061130 - Page3

control panel Control Panel Standard Equipments O I Input Functions display on LCD Generator Volts Generator Volts Generator Amps Generator Frequency Mains Volts Mains Volts Mains Frequency Engine Speed Plant Battery Volts Engine Hours Run Generator total power Generator total power Generator power factor Volts L1-N, L2-N, L3-N Volts L1-L2, L2-L3, L3-L1 Amps L1, L2, L3 Hz Volts L1-N, L2-N, L3-N Volts L1-L2, L2-L3, L3-L1 Hz RPM Volts Hour kva L1, L2, L3,total kw L1, L2, L3,total Cosφ L1, L2, L3,total Deeapse 5220 digital automatic control module Hourmeter Voltmeter Voltmeter commutator Ampermeter Ampermeter commutator Emergency stop button Deepsea 5220 Control Module Description The model 5220 is an Automatic Mains Failure Control module. The modul is used to monitor a mains supply and automaticlly start a standby generator set. The module also provides indication of operational status and fault conditions automaticly shutting down the genset and indicating failures by means of an LCD display, and appropriate flashing LED on the front panel. Selected timers and alarms can be altered by the user from the front panel. Alterations to the system are made using the 810 interface and a PC. This interface also provides real time diagnostic facilities Optional Input Functions Engine Oil pressure Fuel level Engine Temperature Alarm Channels Under/over generator voltage Over-current Under/over generator frequency Under/over speed Charge fail Emergency stop Low oil pressure High engine temperature Fail to start Low/high DC battery voltage Reverse power Generator phase rotation error Generator short-circuit protection Loss of speed sensing signal Mains out of limits kpa % C Specifications Environmental Testing Standards 240mm x 172mm dimensions 70mm x 40mm dimensions, 4 segment grafical LCD monitor Developed 16-bit Microprocessor design Easy comprehended display (Hid-Til-Lit SMD LED technology) LED mimic diagram SMS messaging capability with suitable GSM Modem PC software is MS Windows based and allows the operator to control the module from a remote location (P810 Software Kit necessary) Easy pushbutton controls System parameters can be adjusted manually from the front panel kva,kw ve Cosφ measurements Communication with MODEM Pushbutton Controls STOP / START AUTO, TEST, MANUAL LCD PAGE Electromagnetic Compatibility BS EN 50081-2:1992 and EN 61000-6-4:2000 EMC, Emission Standards for the Industrial Environment EN 61000-6-2:1999 EMC, Immunity Standards for the Industrial Environment Vibration BS EN 60068-2-6 Ten sweeps (up and back down) at 1 octave/minute in each of the three major axes. 5Hz to @ +/-7.5mm constant displacement. 8Hz to 500Hz 2gn constant acceleration. Temperature Cold : BS EN 60068-2-1 to -30 C Hot : BS EN 60068-2-2 to 70 C Humidity BS EN 2011 part 2.1 93% RH @ 40 for 48 hours Shock BS EN 6068-2-27 Three half sine shocks in each of the three major axes 15gn amplitude.11ms duration. Electrical Safety BS EN 60950 Low Voltage Dirctive/Safety of information technology equipments, including electrical business equipment Technical Data Sheet 061130 - Page4

CUKUROVA Diesel Generator Codes and General Information Cukurova Diesel Generator CJ 1100 P N N Group - Alternator brand (Newage/Stamford) P Series - Engine brand (Perkins) Standby Power - kva Cukurova generator Perkins 4000 Series Diesel Engine Newage/Stamford Alternator 4008 T A G 2A HC I 63 4 J Power level Core Length Genset engine Number of poles Air-to-air charge cooled Shaft Height in cm Turbocharged Industrial 4000 Series, 8 cylinder Generator type Information Power Ratings Electric Formulas Standby power rating is for the supply of emergency power at variable load for the duration of the non-avalaibality of the mains power supply.no overload capacity is available at this rating.a standby rated engine should be sized for an avarage load factor of 80% based on published standby rating for 500 operating hours per year.standby ratings should never be applied except in true emergency power failure conditions. Values kwe Formula kwm X E kwe kva (U x I x 1.73 x pf) / 1000 (U x I x 1.73) / 1000 kva x pf kwe / pf Prime power rating is available for unlimited hours per year with a variable load of which the average engine load factor is 80% of the published power rating, incorporation of a 10% overload for 1 hour in every 12 hours of operation which permitted I (Amp) Frequency (kwe x 1000) / (U x 1.73 x pf) (kva x 1000) / (U x 1.73) ( Rpm x N Pole) / (2 x 60) Continuous power rating is available for continuous full load operation.no overload is permitted. Acc. to ISO 3046/1, BS 5514, DIN6271 Rpm kwm: Mechanical Power kwe : Electrical Power pf : Power factor E : Alternator efficiency (2 x 60 x Frequency) / N Pole I : Current (A) U : Voltage (V) kva : Power Rpm: Revolutions per minute Technical Data Sheet 061130 - Page5

, O I CUKUROVA Diesel Generator General Dimensions Standard Generator W Length, L 4,9 m Heigth, H 2,5 m Width, W 1,88 m H CONTROL PANEL Weight, Total 8000 kg L Generator with Soundproof Canopy L W Length, L 6,5 m Heigth, H 3,1 m Width, W 2,25 m H Weight, Total 10.640 kg Generator Room Layout CONTROL PANEL Above drawings dimensions and weights are only for guidence.for installation design of your specific application, necessary certified drawings, at site consultancy service as well as maintenance and installations manuals will be provided by Cukurova without any charge. Specifications may change without notice Technical Data Sheet 061130 - Page6