Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation



Similar documents
BATTERY CHARGING GUIDELINES FOR 6-VOLT DEEP CYCLE BATTERIES

SOLAR PV SYSTEM MAINTENANCE GUIDE

If you accidentally get battery acid on your skin, flush it with lots of water

12 Volt 30 Amp Digital Solar Charge Controller

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Temperature Compensated Charging of Lead Acid Batteries

Height w/o Terminals (in)

BATTERY CHARGER OWNER S MANUAL

TROJAN BATTERY USER S GUIDE

BATTERY SERVICE. This Automotive Series BATTERY SERVICE has been developed by. Kevin R. Sullivan. Professor of Automotive Technology Skyline College

Carefree Sealed Lead Acid (SLA) MSDS

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

Manual. Solar Fountain Mobile Phone Charger

SOLAR BOOST 2000E 25AMP 12VDC MAXIMUM POWER POINT TRACKING PHOTOVOLTAIC CHARGE CONTROLLER INSTALLATION AND OPERATION MANUAL

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

ACHIEVING CHARGE QUALITY FOR LEAD ACID BATTERIES IN INDUSTRIAL MOTIVE APPLICATIONS

Height w/o Terminals (in)

Li Battery Pack & Charger Safety & Operating Instructions

Standard Operating Procedure (SOP) Car/Truck Battery Safety

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

SOLAR POWER - THE NEW WAY TO RV!

Constant Voltage Charger Selection for VRLA Batteries

Installation and Operating Instructions (for chargers shown below)

Solar Controller / Battery Charger User s Manual

Solar charger controller User s Manual

Batteries and inverters

Understand Hybrid Generator Battery Systems

Battery Handbook. By: RON SMITH

POWER TO GET THE JOB DONE

I4.35. Link Owner's Manual. AL Xantrex OWNERS MANUAL. Link Inverter Controller and Dual Battery Monitor. Link Control.

Charger Output AC Ripple Voltage and the affect on VRLA batteries

THE PROPER CHARGING OF STATIONARY LEAD-ACID BATTERIES. (YOUR BATTERY IS ONLY AS GOOD AS HOW YOU CHARGE IT.)

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

Charge Regulator SCR 12 Marine

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Switch Mode, Automatic, Lead Acid Battery Charger 3 Stage (IUoU)

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

PV (photovoltaic) Basics There are generally two types of PV systems. The first and easiest (though the least flexible) is a grid tie system where

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

MXS 3. MANUAL FULLY CHARGED PULSE, MAINTENANCE CHARGING EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT CHARGE CABLE ERROR LAMP MODE- BUTTON

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

LEAD ACID BATTERY working LIFETIME STUDY

TELEDYNE BATTERY PRODUCTS. INSTRUCTIONS FOR CONTINUED AIRWORTHINESS and COMPONENT MAINTENANCE MANUAL. For

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

Managing a 12-volt solar system

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

BATTERY BASICS. This Automotive Series 12-volt Lead Acid BATTERY BASICS has been developed by. Kevin R. Sullivan

CHARGING SYSTEMS INTERNATIONAL

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

BATTERY CHARGER MULTI US 7000

12V Battery Charger & Engine Starter

MULTI XS 4003 Battery charger

Battery Model: 25 Part Number: Nominal Voltage: 12 volts NSN: Number applied for, product currently available

MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel

TROUBLESHOOTING GUIDE

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

How To Use A Power Supply Unit (Upu)

Sport Ice Elektro 124

PART 1 - INTRODUCTION...

AC Coupling of Inverters for Grid Tied PV Systems

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

MOBILE DC POWER SYSTEMS FOR SUBSTATION APPLICATIONS

400 Amp Rechargeable Jump Start System RAC-HP082

Home Solar Kit Owner s Manual. Model: HS

BATTERIES. Battery Types. General. Battery Functions

BATTERY CHARGER OPERATOR'S MANUAL

OPERATING INSTRUCTIONS

CHARGING METHODS. Methods of Charging the Valve Regulated (Sealed) Lead-Acid Battery. 19 Valve Regulated (Sealed) Lead-Acid Batteries

13 Watt PORTABLE SOLAR POWER KIT

Battery charger. Art.no Model CB5-5L-BS1 ENGLISH SVENSKA NORSK SUOMI. Ver Original instructions

VLT Series 300 Watt True Sine Wave Inverter

XW-MPPT Owner s Manual. XW Solar Charge Controller

ELECTRIC HEATER COMPANY Operating and Maintenance Manual For Immersion Heating Elements

Fast Charging Facts Enhancing use of electric lift trucks, AGVs, and other motive electric vehicles

10 Year VRLA Battery Periodic Maintenance Instructions

NorthStar Battery (NSB) Telecom Installation and Operation Guide

User Manual HomeGrid 3000 Solar Generator

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

OUTPUT CABLE CONNECTIONS:

Installation and Operating Instructions (for chargers shown below)

A user guide to simple monitoring and sustainable operation of PV-diesel hybrid systems. Handbook for system users and operators

OWNER S MANUAL FOR MINN KOTA ONBOARD BATTERY CHARGERS Models: MK110D,MK210D, MK220D, MK315D, MK330D

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

VRLA BATTERIES AUGUST

User s Manual AURORA 1.2K/2.2K

Changers Kalhuohfummi User Manual

ME-BMK/ME-BMK-NS. Battery Monitor Kit. Owner s Manual

Battery Power Inverters

Freedom Owner's Manual. Xantrex Freedom 458 Series Inverter/Charger

Mobile Data Power Model: MDP-25

STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

Technical Manual. Powersports Batteries

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Table Of Contents

THIS MANUAL REFERS TO THE FOLLOWING MODULES G G G G EG EG EG EG

You Too, Can Recondition Batteries

Transcription:

Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation BATTERY CHARGING GUIDELINES FOR GLOBAL/DAVIDSON TUBULAR PLATE BATTERIES Introduction Your Global/Davidson battery set has been specially formulated for long cycle life and has unique voltage and specific gravity characteristics. The battery charging set points specified in this guide are for these batteries only, and should not be assumed appropriate for other batteries. It is far easier to discharge a battery than to recharge it. Both the charge and discharge of batteries involve significant inefficiencies. As a rule of thumb for each amp hour of power taken out of a battery 1.5 amp hours must be replaced. In order to complete the chemical process, which recharges a battery the electrolyte, must reach 104 0 F. The method used to heat up the electrolyte is the application of charging current (amps) to a discharged battery. If insufficient charge is applied to bring the electrolyte to this temperature the batteries will never fully recharge, and over time, their capacity will be reduced. Minimum Charging Requirements The ideal charging current, which would be applied to recharge your battery, is 10% of the 20 hour rated capacity of the battery. For example a 1065 amp/hour battery (85T-17 @ 72 hour rate 1 ) will require an initial start up rate of 85 amps (850 amp/hours @ 20 hours) to be supplied by the selected battery charger. A combination of charging sources such as generator/pv array can be used to achieve the initial charge. As you get into larger battery banks, such as a 24V bank of 85T27 s (1795 amp hours @ 24v) you may find that you need a very large charger & generator to achieve the above settings. This is not possible in all system configurations. In general, you need a larger generator than you might think you do to charge these batteries. Voltage and Time Settings In addition to minimum charge rates there are charging voltage settings, which are specific to your Global/Davidson battery set. Bulk Charge Voltage is the voltage at which the batteries will receive most of the charging. When the battery has reached its bulk voltage level the charge current will slowly decrease as batteries become more charged. As a battery becomes more charged it presents more resistance to the flow of current than when discharged, hence the rate of amps declines during a charging cycle. This part of the charging cycle is called the absorption stage. We recommend 30 minutes of absorption time per 100 amp hours of battery bank rated capacity (72 hour rate). All batteries will self-discharge over time, even if they are not used. In stand-by applications where utility power is available batteries are often finish charged at float voltage. This is the voltage level, which can be applied to the batteries to maintain their charged state and, at the same time, minimize loss of electrolyte. In generator cycle charging applications it is rare to float the batteries as it represents a costly and inefficient use of fuel. Regular equalization charging is required as part of a battery maintenance routine. An equalization charge is an intentional overcharge, which causes rapid bubbling of the electrolyte, which in turn helps dislodge sulfation, which occurs naturally during normal charge/discharge cycling. Equalization charge settings involve both voltage and time specifications. Table 1 shows the appropriate settings for Bulk, Absorption, Float and Equalization stages of charging. Many programmable chargers and inverter/chargers have provisions for custom voltage, current, and time settings. Your Global/Davidson batteries will perform best if charged at the settings shown in Table 1. 2 1 The @ X hour rate refers to the length of time it would take to discharge the battery. Most batteries are rated at the 6, 20 and 72 hour rates. The 72 hour rate is appropriate in most residential applications. 2 Charger should be temperature compensated and adjust all voltage values accordingly.

Page 2 of 5 Table 1: Recommended Voltage and Current settings for recharging Global/Davidson Batteries Stage Vdc per Current Time cell Until voltage setting is reached which Bulk 2.475 Vdc 10% rated Amp Hour capacity automatically initiates Absorption stage Will taper as batteries 30 minutes per 100 Amp Hour of rated Absorption 2.475 Vdc recharge capacity 3 Float 2.35 Vdc 1% rated Amp Hour capacity Time continuous 4 Equalization 2.65 Vdc Battery will self regulate 15 minutes per 100 Amp Hour of rated current capacity Specific Gravity - The specific gravity of your Global/Davidson battery is somewhat different from other brands of battery. They are actually fully charged at a lower specific gravity than most batteries and as a result they will actually be charged before most hydrometers will indicate full charge. The most accurate way to use a hydrometer to measure state of charge is to take note of when the specific gravity stops rising. Take readings every ½ hour during the last part of Absorption Stage, when the hydrometer does not rise from your last reading the batteries are fully charged. The correct fully charged specific gravity of your Global/Davidson battery is: 1.265 1.275 (will vary dependent on battery age, condition and ambient temperature) Safe Operating Voltage - Another result of the special formulation and design of these long lasting deep cycle batteries is that they tend to operate at lower voltages than most higher specific gravity batteries, thus the safe operating voltage range of Global/Davidson batteries is lower than most other batteries. It is quite normal and safe to operate your batteries as low as 2 Vdc per cell 5. They should always be recharged when they reach a standing voltage of less than 1.975 per cell 6. Table 2 shows the conversion of Volts per cell settings to 12, 24 and 48 Vdc values. Table 2: Converting Volts per cell to battery bank voltage. Stage Per Cell @ 12 Vdc @ 24 Vdc @ 48 Vdc Bulk/Absorption 2.475 14.85 29.7 59.4 Float 2.35 14.1 28.2 56.4 Equalization 2.65 15.9 31.8 63.6 Safe operating 2.0 12 24 48 Should Recharge (standing voltage) 1.975 11.85 23.7 47.4 BATTERY WARRANTY MAY BE VOIDED IF THESE GUIDELINES ARE NOT FOLLOWED 3 This is a rule of thumb estimate of time, confirm with hydrometer (see recommended specific gravity). 4 Float charging is usually only done when utility power is available. Please note that if batteries are continuously held at a float charge they will loose capacity, regular charge/discharge and equalization cycles are recommended for Yuasa/Davidson batteries. 5 Battery voltage will drop significantly below this point during application of large loads but should recover quickly if batteries are in good condition. 6 In this reference standing voltage is defined as the voltage of a battery after it has neither been charged nor discharged for an eighthour period. The most practical time to assess battery state of charge is early morning as nighttime current draw is usually minimal.

Page 3 of 5 Configuring a DR series inverter for Global Batteries: For normal operation, the battery type selector should be set to # 2 Deep cycle lead acid 2. This is not the factory default setting so must be changed. For an Equalize charge, set the battery type selector to # 8 NiCad 1. This setting has a higher voltage than either of the Equalize settings on that inverter and thus will allow a proper EQ charge for these cells. We highly recommend the use of a BTS Battery Temperature Sensor which is an option for DR inverters and C-series controllers, included with SW series inverter. This sensor will allow the controller to automatically compensate charge rate according to the temperature of the battery. Colder batteries require significantly higher charge rates. The BTS should be mounted such that it will give an accurate reading of the battery temperature. Programming a SW or PS series inverter for Global Batteries: The SW inverter is configured through the digital menu or on the SWRC remote panel or laptop via SWCA interface. Instructions below assume familiarity with the operation of this inverter. More detailed instructions are available in the user manual. The factory default settings on the SW inverter are not adequate for charging global batteries. If the unit is disconnected from the batteries it will loose all settings & revert to factory defaults. The new SW Plus inverter will retain settings. The factory EQ setting is 28.8 which is in effect not an equalize charge at all. Below are the ideal settings. Each installation may have it s own variables and thus these are a general guideline only: Menu 10 Battery charging: Set Bulk Volts DC 29.7 Set Absorption Time 3 9 hours depending on capacity of battery bank (30 min per 100 a/h of battery capacity). Set Float Volts DC 28.2 Set EQ Volts DC 31.8 Set EQ time 1.5 4.5 hours depending on capacity of battery bank (15 min per 100 a/h of battery capacity). How to equalize Global batteries: Bring batteries to a full normal charge. Test with Hydrometer & record all cells. Ensure electrolyte levels are proper (you will add more during the charge cycle). Initiate an equalization charge according to your inverter type. During the final hour of equalize charge, make sure you top up the electrolyte with clean, distilled water. Ensure no debris enters into the battery. Battery tops should always be very clean moisture and debris on the top can cause the batteries to self-discharge. Exercise extreme caution during this process. Goggles & rubber gloves are recommended. After the EQ charge, the tops of the batteries will likely have some mist on them. Wipe carefully with a disposable cloth. Keep this away from clothes, etc. Acid on clothes does not necessarily show immediately next morning or next week you realize the problem and by then it s too late. Dispose of cloths properly. If batteries have not been equalized for a long time, or have been severely discharged and left in a state of discharge for an extended period, it may take several attempts to achieve a proper equalization charge. Repeat this process daily until you are achieving proper EQ voltage.

Page 4 of 5 Have baking soda on hand to neutralize any spills on ground, clothes, etc. Do not allow baking soda inside the batteries! Programming a C-series (C35/C40/C60) controller for Global Batteries: The C-series controllers unfortunately do not offer the ideal adjustments for some settings. We generally don t recommend that the automatic-eq feature be used; as it s unlikely you will achieve a proper equalization charge. Instead, control this manually by depressing the reset switch for 10 seconds. Some sites such as unattended sites may benefit from the automatic EQ feature. The following settings are made via the adjustments accessed by removing the front cover of the c-series controller. The manual describes this process in detail. A digital volt meter is required to properly calibrate these settings. Bulk: 29.7 VDC Float: 28.2

Page 5 of 5 BATTERY SAFETY INFORMATION In the event of exposure to battery electrolyte, wash the area with soap and water. If acid enters the eyes, flood them with running cold water for at least 15 minutes and get immediate medical attention. Always wear eye protection, such as safety glasses, when working with batteries Remove all loose jewellery before working with batteries. Never work alone. Have someone assist you with the installation to be close enough to come to your aid when working with batteries. Always use proper lifting techniques when handling batteries. Always use identical types of batteries. Battery life will be compromised when mixing different types or ages of batteries. Batteries are temperature sensitive. For optimum performance, they should be installed in a stable temperature environment. Battery capacity can be reduced substantially when batteries are cold. Batteries should be installed in a well-vented area to prevent the possible build up of explosive gasses. For safety reasons, a well-sealed battery box, vented at its highest point to the outside, is required for indoor installation (and recommended for outdoor installation) of your lead acid batteries. Seal entry point of battery cables from inverter into battery box with silicon or duct seal putty. NEVER smoke in the vicinity of a battery or generator. Always verify proper voltage and polarity before connecting batteries. Always connect batteries first then connect the cables to the inverter or controller. This will greatly reduce the chance of spark in the vicinity of the batteries. Use insulated tools when working with batteries Do not short circuit battery cables. Fire or explosion can occur. Always recycle old batteries. Contact your local recycling centre for proper disposal information.

Battery Service Record Chart Date Last Equalization Charge Battery Resting Voltage Specific Gravity Cell 1 Cell 2 Cell 3 Cell 4 Cell 5 Cell 6 Cell Voltage Cell 1 Cell 2 Cell 3 Cell 4 Cell 5 Cell 6 Always wear gloves and goggles when performing battery maintenance! Use only distilled water to refill your batteries! Clean acid spills with baking soda and water! Recharge your batteries often!