biologic RR Comfort Creating dimensions in intelligent blood pressure stabilization Haemodialysis



Similar documents
Single-Needle Cross-Over System. Brief description

The Dialog+ Dialysis System

Patient Safety by Fresenius Medical Care Where new benchmarks are set

Current Renal Replacement Therapy in Korea - Insan Memorial Dialysis Registry, ESRD Registry Committee, Korean Society of Nephrology*

CRRT with Prismaflex LEADS TO More Flexibility, Ease of Use and Safety

The Hemodialysis Machine Case Study

Haemodialysis. Dialysers and Filters Product Range

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

10. Treatment of peritoneal dialysis associated fungal peritonitis

3 rd Russian-Bavarian Conference on Bio-Medical Engineering

B. Braun Space GlucoseControl (SGC)

Information technology. Therapy Data Management System Data Acquisition, Data Management and Quality Assurance

Measure #236 (NQF 0018): Controlling High Blood Pressure National Quality Strategy Domain: Effective Clinical Care

First Steps towards a Frequent Pattern Mining with Nephrology Data in the Medical Domain. - Extended Abstract -

Upper Arm Blood Pressure Monitor SC Instructions for use

2016 PQRS OPTIONS FOR INDIVIDUAL MEASURES: CLAIMS, REGISTRY

How to measure blood pressure using digital monitors

How can I manage all automation software tasks in one engineering environment?

AA: Dialysis Nursing Specialty

Summary. Master-/Bachelor Thesis

GETTING STARTED WITH LABVIEW POINT-BY-POINT VIS

International Journal of Comprehensive Nursing

Disposables the Original by B. Braun

CA VM:Operator r3. Product Overview. Business Value. Delivery Approach

Preface to Practice Standards

Home Dialysis Benchmarks Workgroup. Peritoneal Dialysis (PD)

Intradialytic hypotension: Frequency, sources of variation and correlation with clinical outcome

PRISMAFLEX CRRT SYSTEM

MANAGING RISING HEALTHCARE COSTS SOLUTIONS TO A FRAGMENTED SYSTEM

Welch Allyn Connex Vital Signs Monitor 6000 Series and Accessory Cable Management Stand. Advanced accessory management that stands on its own.

CardioCard System. Product Specification and Sample Reports. PC-Based ECG CardioCard. PC-Based Stress. PC-Based Holter. CardioCard.

Are venous catheters safe in terms of blood tream infection? What should I know?

Suunto t6 Heart Rate Monitor Review

Current Trends in the Use of Peritoneal Dialysis Catheters

D Gentle for the newborn, efficient for you. DRÄGER JAUNDICE METER JM-105

FORTE REACH TRUCKS TERGO UNS/UHS

Section Two: Arterial Pressure Monitoring

Hemodialysis Access: What You Need to Know

Inpatient Heart Failure Management: Risks & Benefits

Concept Series Paper on Disease Management

Paragon Recovery Media Builder

What is our purpose?

Graphical Scheduler. Get on time All the time. For Production

Double pumping of intravenous vasoactive drugs in the critical care setting.

INTRUSION PREVENTION AND EXPERT SYSTEMS

Integrated Medical Record System for Nephrology

2016 PQRS OPTIONS FOR INDIVIDUAL MEASURES: REGISTRY ONLY

The MEDOS VAD System

GUIDELINES FOR PROVIDING CONSULTANT AND DISPENSING SERVICES TO ASSISTED LIVING RESIDENTS

LEONI ORION Precision patient positioning system Synchronicity with six degrees of freedom

Telemedicine in Prevention and Chronic Disease Management

Estimation of Sympathetic and Parasympathetic Level during Orthostatic Stress using Artificial Neural Networks

Das Trajekt-Modell 1. The Trajectory Model

Measuring Your Blood Pressure at Home. A Review of the Research for Adults

Edwards FloTrac Sensor & Edwards Vigileo Monitor. Measuring Continuous Cardiac Output with the FloTrac Sensor and Vigileo Monitor

Suffolk County Community College School of Nursing NUR 133 ADULT NURSING I

Is load testing during initial acceptance inspection still the contemporary method?

Blood Pressure Tracker User Manual

Scottish Diabetes Survey Scottish Diabetes Survey Monitoring Group

Brief instructions COMBOX basic and pro for fixed network and mobile.

Manual Blood Pressure Measurement

Summary HTA. HTA-Report Summary. Introduction

Subclavian Steal Syndrome By Marta Thorup

University of Michigan Dearborn Graduate Psychology Assessment Program

Vasc Health Risk Manag. 2011; 7: Published online 2011 November 30. doi: /VHRM.S27193 PMCID: PMC

Phone: Fax:

Heart transplantation

Use of Glycated Hemoglobin and Microalbuminuria in the Monitoring of Diabetes Mellitus

Systolic Blood Pressure Intervention Trial (SPRINT) Principal Results

Agile Manufacturing for ALUMINIUM SMELTERS

OEM MAXNIBP Frequently Asked Questions

Transit NXT. Ergonomic design New functions Process-optimised user interface. STAR Group your single-source partner for information services & tools

High Blood Pressure and Your Kidneys

33 % of whiplash patients develop. headaches originating from the upper. cervical spine

2000 Series Ultrasonic Welding

getemed Medizin- und Informationstechnik AG

ESCO- Information Technology Requirements With An Example of Solutions

case management controlled

Name: OMRON M3 HEM-7200-E Upper Arm Blood Pressure Monitor

Electronic Oral Health Risk Assessment Tools

Device Equivalence Evaluation Form

Standard Comparison Protocols at NICU, Regional and National levels.

I WANT TO INNOVATE & EXPAND MY BUSINESS WITH DIGITAL PRINTING

PANORATIO. Big data : Benefits of a strategic vision. White Paper June Executive Summary

Methodology Understanding the HIV estimates

Kidney Transplantation

Embedding the Concordat in the NHS: Design, Evaluation and Procurement

The ebike Rechargeable Battery Guide

Hemodialysis catheter infection

Examination Content Blueprint

Voltage/current converter opamp circuits

tips Insulin Pump Users 1 Early detection of insulin deprivation in continuous subcutaneous 2 Population Study of Pediatric Ketoacidosis in Sweden:

Transvision Waste Planner

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

The K2 order picking system automatically more efficient.

The volume of a penny will be calculated from its mass and density.

FREEPHONE FREEFAX

HEALTH CARE DESIGNED AROUND You.

HMI. Provide health care services with a cashless access (may include some cost sharing)

Transcription:

biologic RR Comfort Creating dimensions in intelligent blood pressure stabilization Haemodialysis

Intelligent Dialysis Technology Creating dimensions in treatment quality With the Dialog+ dialysis system available in 3 basic configurations B. Braun is raising the bar in the field of extracorporeal blood treatment. In Dialog+, intelligent software is perfectly integrated into sophisticated high-grade, hardware-equipped original accessories. As with every one of our products, every purchase is backed by excellent service support and dependable global logistics. The Dialog+ dialysis system represents the foundation of our concept: therapy quality, efficiency and ergonomics. Why choose biologic RR Comfort? Over the years, B. Braun has continuously developed and improved its dialysis technology - making it safer for patients, more economical for dialysis centres and more efficient for nurses. Demographic trends indicate that the number of patients dependent on dialysis will continue to grow, thus placing ever increasing demands on haemodialysis procedures. Dialysis-related complications, such as drops in blood pressure, are an inherent part of the therapeutic process. Causes of hypotensive episodes include losses in intravascular volume, lack of vascular reactivity and other cardiac-related incidents. These hypotensive episodes require treatments, such as therapeutic interventions and blood pressure stabilising infusions. In the worst case, it may even be necessary to interrupt the dialysis session. 2

Gentle treatment with biologic RR Comfort The innovative biologic RR Comfort biofeedback system from B. Braun considerably reduces hypotensive episodes and symptoms during the course of dialysis (Fig. 1). The system is specifically designed for the long-term treatment of chronic haemodialysis patients prone to drops in blood pressure. biologic RR Comfort is the only biofeedback system that measures the patient s blood pressure directly a feature which makes the system especially safe and reliable. By automatically regulating the ultrafiltration rate (UFR), biologic RR Comfort prevents the patient s blood pressure from dropping drastically during treatment sessions. Fig. 1: Reduction in hypotensive episodes In an 18-week prospective multicenter study on patients prone to hypotensive episodes (60 %), the use of biologic RR Comfort lowered the frequency of hypotensive episodes to 34% 1, equivalent to a 44 % reduction. However, the biologic RR Comfort is not limited to just one therapeutic application - in combination with the Dialog+ dialysis machine, the system is compatible with haemodialysis (HD), haemofiltration (HF), haemodiafiltration (HDF) and singleneedle (SN) procedures. State-of-the-art technology with maximum convenience biologic RR Comfort is the further development of our earlier biofeedback system. During the dialysis session, it automatically measures blood pressure in a closed loop (Fig. 2). The system has been programmed to control the UFR based on precise, scientific medical knowledge and clinical empirical values. In addition to the current blood pressure profile, the system takes into account the blood pressure profiles from previous sessions that are stored in memory. If a patient s blood pressure moves into a control range defined in the system, a control algorithm is instantly activated. Based on this information, the system autonomously determines if and how the UFR needs to be adapted to the respective treatment situation. Intelligent controls compensate for any conceptual reductions in the UFR during the session. Clinical survey data show that the total ultrafiltration volume is generally achieved within the scheduled treatment time. Fig. 2: Control algorithm of biologic RR Comfort 1 Roeher O, Schmidt R, Korth S et al.: «biologic RR Comfort reduces hypotensive episodes in patients prone to intradialytic hypotension». 38th Congress of the German Society of Nephrology, Munich, 2007 3

A learning system Innovative Guideline Technology Each patient s blood pressure profile follows physiological principles. biologic RR Comfort incorporates this knowledge into the treatment by storing the blood pressure profiles of previous dialysis sessions on the Patient Therapy Card for use in future treatments. The system performs close-interval blood pressure measurements in the first 45 minutes of the session; it then reads the card s memory to determine the most similar course of therapy stored on it. During the dialysis session, regular measurements ensure that this blood pressure profile is adapted to the current blood pressure of the patient. This generates a Guideline that forms the basis for regulating the UFR. Thanks to this technology, the intervals between check measurements towards the end of the session can be extended by up to 30 minutes. Overall, this function can reduce the number of blood pressure measurements by up to 60 % compared with the previous system. biologic RR Comfort enables early detection of impending hypotensive episodes, thus allowing preventative measures to be undertaken in good time. And the system learns as it goes along the more data that are stored, the better and more accurate biologic RR Comfort becomes. Non-invasive blood pressure measurement RR Dialysis-session with biologic RR Comfort The blood pressure is measured directly on the patient using sphygmomanometry. Automatic blood pressure measurements are performed at 5, 15, 20 and 30-minute intervals, depending on the course of treatment. As few as 18 blood pressure measurements are needed during a complication-free 4-hour dialysis session. Ultrafiltration rate UFR The majority of hypotension-prone dialysis patients tend to experience their blood pressure dropping towards the end of the session. This is why biologic RR Comfort implements ultrafiltration at the start of a dialysis session at up to 200 % of the average UFR. As the session proceeds, the system gradually lowers the UFR to 40 %. This low UFR means that by the end of the treatment, most patients are able to leave the dialysis centre with stable blood pressure and in a good physical condition. 4

Setting the Systolic Low Limit (SLL) The SLL is the lowest blood pressure permitted by the system. If, in spite of activated control algorithm (trips at 25 % above the SLL), the blood pressure falls below this limit, the system instantly adjusts to the lowest possible UF rate. Based on statistical evaluation of previous sessions, the system calculates the SLL and the nurse usually just needs to confirm the value by tapping the touch screen. Rotis Sans Serif Pro Bold, 8/11pt, schwarz 100% Setting the maximum UFR The maximum UFR is entered separately for each individual patient. The settings can be entered in milliliters per hour (ml/h) or, alternatively, in percent. The high UFR achieved at the start of dialysis session are possible due to the low volume extraction at the end of the session. The system is able to exceed the generally applied standard limits, thanks to biologic RR Comfort's integrated Guideline technology. Guideline - The guiding curve The Guideline is based on one of the up to 100 blood pressure profiles stored from previous treatments. Once it has been adapted to the conditions of the current dialysis, the new guideline is stored and the oldest curve is deleted. By storing the data on the Patient Therapy Card, the blood pressure profiles and the most recently used maximum UFR are ready to hand for all future sessions. 5

Beneficial in every respect... for users Not only does biologic RR Comfort help optimise therapy, it also improves many work processes at the dialysis centre. The economic advantages of biologic RR Comfort are impressive. The reduction in the number of interventions required to treat hypotensive episodes effectively reduces the work load of nursing staff and lowers the costs for blood pressure stabilising saline solutions and there are no extra costs for special disposables. The easy handling of the system, with only two key settings re quired via touch screen, also increases reliability for nursing staff. The time saved thanks to biologic RR Comfort s quick and easy handling and the reduced time requirements per treatment thanks to Guideline Technology allow more time to be devoted to improving the individual care of patients. biologic RR Comfort a learning system 3 In order to document the efficiency of biologic RR Comfort, B. Braun conducted an 18-week, prospective, multicenter study on patients prone to hypotensive episodes. Within this period, each patient underwent a total of 54 treatment sessions. The results of the observational study (Fig. 3) prove that biologic RR Comfort achieves a significant improvement in dialysis treatment after just a few sessions. At the end of the study, the system was already working at high efficiency: 52 % fewer sessions with hypotensive episodes (HE) 82 % fewer sessions with at least one hypotensive symptom 64 % fewer sessions requiring at least one therapeutic intervention due to an HE.... for patients biologic RR Comfort significantly reduces the frequency of hypotensive episodes, symptoms and the associated therapeutic interventions (Fig. 3). Fig. 3: Results of the observational study Equally, the quality of treatment increases because the system learns over time. This means that it is generally possible to adhere to session times and improve the effectiveness of dialysis. Furthermore, the significant reduction of blood pressure measurements required compared to the previous system and the special ultrafiltration control considerably enhance the patient s feeling of well-being during and after dialysis. 1 Retrospective period without biologic RR Comfort (7 weeks) 2 Means over each period 3 Roeher O, Schmidt R, Korth S et al.: biologic RR Comfort reduces hypotensive episodes in patients prone to intradialytic hypotension. 38th Congress of the German Society of Nephrology, Munich, 2007 6

Technical data Settings Max. UF rate in % 100-200 % Max. UF rate absolute 0-3000 ml SLL 65-135 mmhg Technical data Measurement ranges Systolic pressure 45-280 mmhg Diastolic pressure 15-220 mmhg Mean arterial pressure (MAP) 25-240 mmhg Accuracy +/- 3 mmhg or +/- 2 % Individually adapted alarm limits Blood pressure measuring time in an adult with a blood pressure of approx. 28 sec 120/80 mmhg Pressure range for the cuff Default target cuff inflation Target cuff inflation pressure/ last systolic pressure 0-300 mmhg 200 mmhg +30 mmhg Overpressure cut-off 300 mmhg + 10 % Pressure cuffs are supplied in 3 different sizes Significant reduction in hypotensive episodes Significant reduction in the number of required BP measurements Continuous improvement in treatment quality Reduction in therapeutic interventions No follow-up costs Easy handling References Roeher O, Schmidt R, Korth S et al.: biologic RR Comfort reduces hypotensive episodes in patients prone to intradialytic hypotension. 38th Congress of the German Society of Nephrology, Munich, 2007. Mancini E, Mambelli E, Irpina M et al.: Prevention of dialysis hypotension episodes using fuzzy logic control system. Nephrol Dial Transplant (2007): 22 (5): 1420-1427. Schmidt R, Roeher O, Korth S et al.: Intradialytic hypotension (IDH): Effective reduction of hypotensive episodes (HE) by blood pressure-guided auto-mated ultafiltration control (biologic RR Comfort). 40th ASN Meeting, San Francisco, 2007. 7

Significant reduction in hypotensive episodes Significant reduction in the number of required BP measurements Continuous improvement in treatment quality Reduction in therapeutic interventions No follow-up costs Easy handling B. Braun Avitum AG Schwarzenberger Weg 73-79 34212 Melsungen Germany Tel. +49 5661 71-2624 Fax +49 5661 75-2624 dialysis@bbraun.com www.bbraun-dialysis.com W. 02.05.09/1 Nr. 708 0086A Edition: 05/2009