Druck PV 62x pneumatic/hydraulic pressure stations



Similar documents
Druck DPI 104. GE Industrial Sensing. Digital pressure indicator User manual - K394

GE Druck. Hand Pumps Pneumatic/Hydraulic hand pump Product Guide. Pneumatic hand pumps from -1 to 60 bar. Hydraulic hand pumps from 0 to 1000 bar

Rexroth Hydraulic Pump A10VO Series User Manual

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Standard Hydraulic Piping Flushing Procedure

The PACE5000 Modular Pressure Controller/Indicator

ACCUMULATOR INSTALLATION

Hydraulic control unit series

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Druck DPI 104-IS Intrinsically safe digital pressure indicator

PBX Series Quick Fit Connector Bimetallic Steam Traps

Diagnosing Hydraulic Problems

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

NITROUS TRANSFER PUMP INSTRUCTIONS

How To Make A Modular Test Instrument

Instructions For SF 6 Refill Kit

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Cooling system components, removing and installing

Meritor WABCO Hydraulic Power Brake (HPB) System Bleeding Procedures

Stainless Steel Single and Dual Circulation Kits

KNC Model 3666 Automatic Pressure Calibration System

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

National- Spencer Inc.

PACE Modular Pressure Controller

MODEL G300 BRAKE BLEEDER

Model 2128 AIR COMPRESSOR PUMP Operating Instructions

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

INSTRUCTIONS FOR USE SAFETY PRINCIPLES, OPERATION AND MAINTENANCE FOR. HYDRAULIC PUMP type HP 03L, 05L, 07L volume 3 l, 5 l, 7 l

Basic Hydraulics and Pneumatics

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

SunMaxx Solar Filling Station Operating Instructions

Cooling system components, removing and installing

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

CARING FOR YOUR WATER HEATER

Thermocouple Thermometer Models

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

IMPORTANT SAFETY NOTICE

Operating instructions in the back. PD1020L

TANKER - SHORE SAFETY CHECK-LIST

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

San josé OWNER S MANUAL

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

Self Purging Liquid Trap (SPLT ) User s Manual

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

PUMP AND MOTOR DIVISION

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

aseries A13B Mini Bullet Camera User Manual

ENGINE COOLING SYSTEM

Nokia Bluetooth Headset BH-110 User Guide

1. SAFETY INFORMATION

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Thermistor Thermometer MODEL NO

Float and Thermostatic Traps Series H, C and X

Xbox LIVE Vision. english

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Cooling system components, removing and installing

Cooling system components

Hygro-Thermometer + InfraRed Thermometer Model RH101

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) (ROI) White series

VACUUM CLEANER INSTRUCTION MANUAL

Owner s Manual & Safety Instructions

Operating Instructions Electronics module VEGADIF 65

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Cisco TelePresence MCU 4500 Series safety and compliance information

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Nokia Charging Connectivity Cable CA-126

US Installation Manual Smappee Monitor

WIKA INSTRUMENT CORPORATION

HAND PUMP OPERATION, SERVICE AND PARTS INSTRUCTION MANUAL

Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

Pressure Testing Procedures for Building Services Piping

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Your safety and the safety of others are very important.

MP-4V Heavy Duty Riveter / 39048

UV100A Ultraviolet Air Treatment System

User Guide. Temperature and Humidity Datalogger. Model 42280

15GAL STEEL OIL DRAIN WITH 110V PUMP

Portable Air Conditioner

Hand Held Metal Detector

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

PACE1001 Barometer Precision Barometric Indicator and Recorder

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Always there to help you. Register your product and get support at PD7001B. Question? Contact Philips.

BERMAD Fire Protection

USER MANUAL. 10 GPM Small Single Line Cryogenic Coupling

OP300S / OP350 2:1 RATIO TRANSFER PUMP

Transcription:

GE Sensing & Inspection Technologies Druck PV 6x pneumatic/hydraulic pressure stations safety and quick reference guide - K08 A. PV 6: Pneumatic pressure station (Figure A.) -90 mbar to 0 bar (-3. to 300 psi) PV 6: Pneumatic pressure station (Figure A.) -90 mbar to 00 bar (-3. to 00 psi) PV 63: Hydraulic pressure station (Figure A.3) 0 to 000 bar (0 to 000 psi) A. PV 6x + DPI 60 + PM 60 Recommended pressure modules (PM 60) * (Figure B/B) PV 6 models mbar to 0 bar (0.36 to 300 psi) PV 6 models mbar to 00 bar (0.36 to 00 psi) PV 63 models 70 to 000 bar (000 to 000 psi) * Caution: To prevent damage to the PM 60 module, only use it within the specified pressure limit on the label. A.3 PV 6x pressure relief valves (PRV) (Recommended options) Parts: IO60-PRV-P to P (Pneumatic) PV 6 models to 30 bar (. to 3 psi) PV 6 models to 00 bar (. to 00 psi) Parts: IO60-PRV-H to H (Hydraulic) PV 63 models 0 to 000 bar (7 to 000 psi) Note: = See figure, table, or section. 008 General Electric Company. All rights reserved. Trademarks All product names are trademarks of their respective companies.

A. PV 6 A. PV 6 A.3 PV 63 A PV 63: S3. A PV 6, PV 63 Customer service Visit our web site: www.gesensing.com 3 3 3 A3 6 6 6 3 B PM 60: A. 7 7 7 a 8 9 0 9 + S3.3 B PV 6x + DPI 60 + PM 60 A3 PV 6x 3 3 K08 Issue

Quick Reference WARNING: Before you use this instrument, read and understand the Safety section. It is dangerous to ignore the specified warnings. S PV 6 models: Start operations A. (Front cover) S. Release the pressure/attach the device under test Step Procedure. Release the pressure.. Use the applicable adaptor to attach the device; figure A3. S. Vacuum OR pressure operation 3 + - Step Procedure (Vacuum) Step Procedure (Pressure). Set to vacuum operation (-).. Set to pressure operation (+).. Turn the volume adjuster to mid-range or fully clockwise. 3. Seal the system. 8. Turn the volume adjuster to mid-range. 3. Seal the system. 8. Set the vacuum with the pump.. Set the pressure with the pump.. Adjust the vacuum (+ decrease; - increase). 8. Adjust the pressure (+ increase; - decrease). 8 S PV 6 models: Start operations A. (Front cover) S. Release the pressure/attach the device under test Step Procedure b. Release the pressure: Open the refill valve ( turn) then fully open the pressure release valve. a. Use the applicable adaptor to attach the device; figure A3. [EN] English - K08 Issue Quick Reference

S. Vacuum OR pressure operation 3 6 - + Step Procedure (Vacuum). Set to vacuum operation (-).. Open the refill valve ( turn). 3. Wind the volume adjuster to mid-range or fully clockwise.. Seal the system.. Set the vacuum with the pump. 6. Adjust the vacuum (+ decrease; - increase). 9 9 3 + 6 7 + - Step Procedure (Pressure). Set to pressure operation (+).. Wind the volume adjuster to mid-range. 3. Seal the system.. Use the pump to set a pressure up to 0 bar (300 psi).. Open the refill valve ( turn). You now have full control to increase (+) or decrease (-) the pressure with 9 the volume adjuster. 6. If you increase pressure and get to the limit of travel, close the refill valve and wind the volume adjuster 9 fully counterclockwise. There is no change in pressure. 7. Refill the pressure mechanism with the pump ( cycles) and wind the volume adjuster clockwise until 9 the pressure starts to increase. 8. Continue to do steps to 7 until you get the necessary pressure. 9 Quick Reference K08 Issue - [EN] English

S3 PV 63 models: Start operations A.3 (Front cover) S3. Fill the reservoir. Figure A (front cover). The first time you want to use the hydraulic pressure station, use this procedure to fill the reservoir: Step Procedure. Use the applicable adaptor to attach the device; figure A3.. Remove the hydraulic pressure release valve. 3. Use the refill bottle to add the necessary hydraulic fluid but leave a small air gap. Step Procedure. To remove air from the pressure mechanism, wind the volume 9 adjuster through one full cycle (counterclockwise then clockwise).. Seal the system and continue with the normal pressure operation S3. Release the pressure/attach the device under test Step Procedure. Release the pressure: Open the refill valve ( turn) then fully open the pressure release valve.. Use the applicable adaptor to attach the device; figure A3. 0 Note: Fill the reservoir before you attach the device. See figure A (front cover). S3.3 Hydraulic pressure operation 3 + + - Step Procedure. Seal the system.. Close the refill valve and then wind the volume adjuster fully 0 clockwise and counterclockwise 9 until the pressure starts to increase. The counterclockwise operation refills the pressure mechanism without a change in pressure. Step Procedure 3. Open the refill valve ( turn). You now have full control to increase 0 (+) or decrease (-) the pressure 9 with the volume adjuster.. If you increase pressure and get to the limit of travel, close the 0 refill valve again and wind the 9 volume adjuster fully counterclockwise.. Continue to do steps to until you get the necessary pressure. [EN] English - K08 Issue Quick Reference 3

Overview There are three pressure stations in the PV 6x series: PV 6 PV 6 two pneumatic pressure stations to give you accurate and controlled pressure and vacuum conditions: PV 6: -90 mbar to 0 bar (-3. to 300 psi) version PV 6: -90 mbar to 00 bar (-3. to 00 psi) version PV 63 one hydraulic pressure station to give you accurate and controlled hydraulic pressure conditions: PV 63: 0 to 000 bar (000 psi). Other module options Pressure calibrator DPI 60 PM 60 The pressure stations are part of a set of hand-held modules that you can quickly put together to include a wide range of calibrator functions. DPI 60 Pressure calibrator: You can use the pressure stations on their own or you can attach the DPI 60 calibrator and a PM 60 module to make a fully integrated pressure calibrator instrument. Advanced modular calibrator, DPI 60: Optional item. This is a battery-powered instrument for electrical measure and source operations and HART communications. It also supplies the power and user interface functions for all the add-on modules. You can use the touch-screen to display up to six different parameters. Refer to user manual - K09. Pressure modules, PM 60: Optional item. These modules attach to a pressure station (PV 6x) to give the DPI 60 calibrator the necessary pressure measurement functionality. They are fully interchangeable plug and play modules with no initial set-up or user calibration. Overview K08 Issue - [EN] English

Standard equipment These items are part of the standard equipment with a PV 6x pressure station: Removable pressure adaptors (G/ and /8 NPT) PV 63 models only: Refill bottle for hydraulic fluid Safety and quick reference guide CD with the user manual 3 Safety Before you use the instrument, make sure that you read and understand all the related data. This includes: the applicable local safety procedures, the user manual (K07), and the instructions for the accessories/options/equipment you are using it with. General warnings Pressure warnings WARNING It is dangerous to ignore the specified limits for the instrument or to use the instrument when it is not in its normal condition. Use the applicable protection and obey all safety precautions. Do not use the instrument in locations with explosive gas, vapour or dust. There is a risk of an explosion. It is dangerous to attach an external source of pressure to a PV 6x series pressure station. Use only the internal mechanisms to set and control the pressure in the pressure station. Some liquid and gas mixtures are dangerous. This includes mixtures that occur because of contamination. Make sure that the equipment is safe to use with the necessary media. To prevent a dangerous release of pressure, isolate and bleed the system before you disconnect a pressure connection. To prevent a dangerous release of pressure, make sure that all the related pipes, hoses and equipment have the correct pressure rating, are safe to use and are correctly attached. Continued [EN] English - K08 Issue Standard equipment

Electrical warnings Cautions Marks and symbols on the instrument If you use the DPI 60 calibrator with your pressure station, these warnings are also applicable: To prevent electrical shocks or damage to the instrument, do not connect more than 30V between the terminals, or between the terminals and the ground (earth). This instrument uses a Lithium-Polymer (Li-Polymer) battery pack. To prevent an explosion or fire, do not short circuit, do not disassemble, keep it safe from damage. To prevent an explosion or fire, use only the GE specified battery, power supply and battery charger. To prevent damage to the PM 60 module, only use it within the specified pressure limit on the label. To prevent damage to the instrument, do not let dirt get into the pressure mechanism. Clean the equipment before you attach it. Before you start an operation or procedure in this publication, make sure that you have the necessary skills (if necessary, with qualifications from an approved training establishment). Follow good engineering practice at all times. Complies with European Union directives Warning - refer to the manual Read the manual PRV Pressure relief valve Do not dispose of this product as household waste. Refer to Maintenance (Section 6). More marks and symbols are specified in the user manual (K07 - Druck PV 6x pneumatic/hydraulic pressure stations) 6 Safety K08 Issue - [EN] English

Parts Refer to the figures on the front cover (A, B).. Key to figure A (PV 6x pressure stations) A. Optional accessory: Pressure connection for a pressure relief valve (PRV); see table A.3 (front cover). A blanking plug is standard.. Test port: Pressure connection (G/8 or /8NPT) to attach the device under test; see figure A3 (front cover). 3. Pressure and electrical connections for a PM 60 module. PV 6/PV 6 models: Seal the pressure connection with a blanking plug (Part: IO60-BLANK) or a PM 60 module. PV 63 models only: The pressure connection seals itself.. Pneumatic pressure release valve (PV 6/PV 6 models) or hydraulic pressure release valve (PV 63 models) to release pressure in the system. On PV 63 models, it also gives access to the hydraulic fluid reservoir; see figure A (front cover).. PV 6 models only: Pneumatic refill valve. Close it to seal off the device pressure and refill the pressure mechanism (refer to Quick Reference, S). 6. Moulded compartment for the DPI 60 calibrator with electrical connections and a mechanism to hold it in position. 7. Push-button mechanism to release the DPI 60 calibrator. 8. PV 6 models only: Pneumatic volume adjuster 9. PV 6/PV 63 models only: Volume adjuster wheel with fold-in handle. 0. PV 63 models only: Hydraulic refill valve. Close it to seal off the device pressure and refill the pressure mechanism with fluid (refer to Quick Reference, S3).. PV 6/PV 6 models only: Pressure/vacuum selector to set the pump operation: pressure (+), vacuum (-).. PV 6/PV 6 models only: Pump mechanism [EN] English - K08 Issue Parts 7

. Key to figure B (PM 60 module) - Optional item B 3. Pressure module (PM 60) with a pressure connection, reference port (a) and a label. The label includes: Pressure limit. Example: 0 bar g (g: gauge; a: absolute); serial number (S/N); manufacturer: name, address, website Installation Before you start: Read and understand the Safety section. Do not use damaged equipment. Note: Use only original parts supplied by the manufacturer.. External pressure connections. Calibrator assembly See figure A3 (front cover). Use an applicable method to seal the external pressure connections, and then tighten to the applicable torque. Maximum torque: /8 NPT: 3 Nm (6 lbf.ft) G/8: Nm (8. lbf.ft) Optional item (DPI 60/PM 60). See figure B (front cover). Note: To use the DPI 60 calibrator, read the user manuals: K09 (Druck DPI 60 Advanced modular calibrator) and K07 (Druck PV 6x pneumatic/hydraulic pressure stations). B Step Procedure. Lower the calibrator into the moulded compartment.. Press on the bottom end of the calibrator until it latches in position. 3. Attach a pressure module with the correct range and type.. Tighten it until it is hand tight only. 8 Installation K08 Issue - [EN] English

6 Maintenance Clean the case with a moist, lint-free cloth and a weak detergent. Do not use solvents or abrasive materials. Return the instrument to the manufacturer or an approved service agent for all repairs. Do not dispose of this product as household waste. Use an approved organisation that collects and/or recycles waste electrical and electronic equipment. For more information, contact one of these: our customer service department: (Contact us at www.gesensing.com) your local government office. 7 Specification Operating temperature Storage temperature Humidity Shock/Vibration Table : General specification -0 to 0 C ( to F) Note: PV 63 models only. If the temperature is less than C (39 F), the instrument must be fully drained and dry. -0 to 70 C (- to 8 F) Note: PV 63 models only. If the temperature is less than C (39 F), the instrument must be fully drained and dry. 0 to 90% relative humidity (RH) non-condensing Def Stan 66-3, 8. cat III EMC Electromagnetic compatibility: BS EN 636-:006 Electrical safety Electrical - BS EN 600:00 Pressure safety Approved Hydraulic fluid (PV 63 models only) Power supply Pressure Equipment Directive - Class: Sound Engineering Practice (SEP) CE Marked Reservoir capacity: 00 cm 3 (6. in 3 ) Fluid type: Demineralised water or a mineral oil (ISO viscosity grade ) None. If you attach a DPI 60 calibrator to make a pressure calibrator, all the power comes from the DPI 60 calibrator. Refer to user manual K09 - Druck DPI 60 Advanced modular calibrator. 9 Maintenance/Specification K08 Issue - [EN] English

[EN] English - K08 Issue 0

K08 Issue - [EN] English

[EN] English - K08 Issue