RPS/DPS 8100. High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:



Similar documents
RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

UNIK Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard. Expertise

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Druck DPI 142/150. GE Infrastructure Sensing. Pressure Indicator Calibration manual - K382

PACE1001 Barometer Precision Barometric Indicator and Recorder

Pressure transmitter For general industrial applications Model A-10

Druck DPI 104. GE Industrial Sensing. Digital pressure indicator User manual - K394

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

PACE1000 Precision Pressure Indicator

The PACE5000 Modular Pressure Controller/Indicator

Relative and absolute pressure switch type 529

PACE Modular Pressure Controller

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

MicroMachined Silicon modular pressure sensor

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

9000 Series Accelerometers Specifications

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Electronic Pressure Monitoring New Products

DPI 260 SERIES: Digital Pressure Indicators

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Low Frequency Velocity Sensor

and Accelerometers

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Relative pressure transmitter type 520

OEM-EP Pressure Controllers

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

QR12 (1.22 ) Diameter Optical Encoder

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Velomitor Piezo-velocity Sensor

Typical Aluminum GFM Mass Flow Meter

Digital Pressure Measuring Instrument MDR480

Givare NC-SRS 280 och 880

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Features. Picture. Specifications

Precision Pressure Indicator Model CPG2500

Druck DPI 104-IS Intrinsically safe digital pressure indicator

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Conductive Level Switch FK 2 Technical Data:

Electronic Pressure Switch EDS 300

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

Description. Dimensions. Features. precision works better

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Sensors OXYGEN SENSORS PRESSURE SENSORS TEMPERATURE SENSORS ROTARY POTENTIOMETER SPEED SENSORS UEGO LAMBDA BOX STAND-ALONE PRT 02/03/06 P002P010 OPS04

T0118 T2118 T3118. Instruction Manual

Mass Flow Meters & Controllers

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Electronic Pressure Switch EDS 3000

How To Power A Schen

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Heavy Duty Pressure Sensors/ Transducers Line Guide

Datalogger DL/N 70 Version:

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

FEATURES. ! Sealing to IP68 (fully waterproof) Infra-red optical navigation technology

Depth/Level. Druck Submersible Pressure Sensors Product Guide. GE Measurement & Control. Features. Applications. High accuracy. Bore hole monitoring

Model TJE. Precision Gage/Absolute Pressure Transducer DESCRIPTION FEATURES

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Data Sheet PS1B Pressure Switch

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

Inductive sensor NI10-M18-Y1X-H1141

4 Posiflow Proportional Solenoid Valves

Technical data sheet TDS0070

How To Use A Flowmeter

Digital inductive conductivity transmitter

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

Duct Humidity Transmitter

Turbine Flowmeters for Gas Applications

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Laminar Flow Elements

PTU Series Transducer Digital Display Indicator User s Manual

DPI 610/615 Series. Druck Portable. Pressure Calibrators. GE Sensing. Features. Setting the Standard for Portable. Pressure Calibrators

ABSOLUTE ROTARY ENCODER ETHERNET/IP

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Specification of 5 Wire Analog Touch Panel

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

iva Cable & Antenna Analyzer

Product Catalogue. AP Automatyka ISO ISO OHSAS ISO 9001.

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

VE 210. Velocity transducer for low-frequency measurements. » From the Vibro-Meter product line» Low-frequency compensation allows frequency

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

DS 600. A contact free flux gate based current measurement sensor 600A rms

Precision digital pressure gauge Model CPG1500

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

Transcription:

GE Measurement & Control RPS/DPS 8100 High Accuracy Resonant Pressure Sensor For over 40 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial, aerospace, oil and gas, and research environments. Today, Druck is part of GE Measurement & Control and has continually worked to develop and improve on the performance of our pressure sensors to meet customer s requirements. The RPS/DPS 8100 incorporates the exciting new TERPS technology. TERPS is a resonant silicon pressure sensor technology platform that provides an order of magnitude greater accuracy and stability than current pressure measurement technologies. In addition to providing the performance and packaging improvements available with TERPS, the RPS/DPS 8100 product line takes advantage of best practices to offer a wide range of pressure and electrical connections to enable a level of customization for your specific requirements never before available in the performance class of this sensor. The combination of the power of the TERPS technology and the quality, reliability and flexibility of the RPS 8100 Series offer a truly unique solution for high accuracy and high stability pressure measurement requirements. Features: High Precision, ±0.01% FS over compensated temperature range High Stability, ±100 ppm FS/year Wide temperature range, -40 to +85 C (-40 to 185 F) Multiple Output configurations, RS-232, RS-485, Frequency & Diode (TTL) Wide selection of pressure & electrical connections to suit specific requirements Low acceleration effects

Specifications Measurement Base Pressure Ranges 0 to 2 bar (0 to 30 psi) absolute 0 to 3.5 bar (0 to 50 psi) absolute Calibrated Ranges 35 to 3500 mbar (0.5 to 50 psi) absolute 35 to 2000 mbar (0.5 to 30 psi) absolute 750 to1150 mbar (11 to 17 psi) barometric Any zero-based range between 1 and 3.5 bar (14.5 to 50 psi) can be specified. (Values in psi are approximate.) Alternative barometric ranges are available on request. Higher pressure ranges are available in the RPS/DPS 8000 series. Overpressure 2X FS Pressure Containment 7 bar, (100 psi) Supply and Output Electronics Option Supply Voltage (V) Output 0 6 to 28 Frequency^ & Diode^^ (Low Power)* 1 6 to 28 Frequency^ & Diode^^ (Low Noise)** Current Consumption*** (ma) A 11 to 28 RS485 16.5 quiescent, 32 max B 11 to 28 RS232 16.5 quiescent, 32 max * Low Power has Jitter of <120 ns ** Low Noise has Jitter of <75 ns *** At 25 C (77 F) ^ Square wave pressure signal, 25 khz nominal, 4-10 khz span ^^ Forward voltage diode, 0.4 to 0.8 V @ 25 C (77 F), typically 2 mv/ C nominal Response Time Frequency Output <25 ms for pressure change from 10% to 90% FS RS232/485 Output Dependent on the output update rate which is set by the user with a minimum of 100 ms (see manual K0473 for details) 3.5 10 supply switch on Electrical Protection Connecting V supply and GND between any combinations of pins on the connector will not damage the unit Insulation 500 V dc Performance There are two levels of performance specification: Standard and Improved Specifications include combined effects of non-linearity, hysteresis, repeatability and temperature errors over the compensated temperature range and calibrated pressure range. Accuracy Code Precision A1- Standard 0.02% FS A2- Improved 0.01% FS For Frequency & Diode output the above accuracies are achievable by using a polynomial curve fit algorithm and coefficient data supplied with the sensor. Sensors are calibrated against standards traceable to UKAS operating to better than 100 ppm. Compensated Temperature Ranges: There are two compensated temperature ranges available: -10 to +50 C -40 to +85 C Temperature Effects All temperature effects are included in the accuracy statement. Long Term Stability Standard: ±0.02% FS/annum Improved: ±0.01% FS/annum Note: Unless otherwise stated, specifications are at reference conditions: 25 C (77 F) ±5 C (±9 F). Orientation (g) Sensitivity Less than 0.05 mbar/g Supply Response Frequency & Diode: Accurate to specification within 500 ms of supply switch on, over all operating temperatures RS 232/485: Accurate to specification within 20 s of

Physical Specifications Storage Temperature Range As compensated temperature range. Operating Temperature Range -40 to +85 C (-40 to +185 F) Restricted by some electrical connector options. Please ensure that only the intended sealing face is used when mounting the sensor. Failure to comply with this requirement may affect performance or calibration accuracy. Male threaded pressure connectors must not be sealed or constrained against the face at the base of the thread. The forward cone or flat face should always be used, as indicated below. Pressure Media Non-condensing dry gases compatible with 316L Stainless Steel, silicon, silicon dioxide, RTV adhesive and glass Ingress Protection See Electrical Connector Section Vibration DO-160E Curve W Sine sweeps 5 Hz to 2 khz, levels to 20g n <0.2 mbar/g n (<0.003 psi/g n ) output change Shock DO-160E 9 (Figure 7.2) 20 g n 11 ms terminal saw-tooth profile Negligible calibration change Humidity MIL-STD-810D Method 507.2 Procedure III (Aggravated humidity environment, 65 C, 95% RH). It is recommended that in all non-dry environment applications, that sealed electrical connectors are selected (options 3, 4, 6 or G) Pressure Connector Available Options are G1/4 Female G1/4 Male Flat G1/4 Male 60 degree Cone G1/8 Male 60 degree Cone 1/4 NPT Female 1/4 NPT Male 1/8 NPT Male M20 x 1.5 M14 x 1.5 60 degree Internal Cone M12 x 1 Internal Cone 7/16 UNF Male G1/2 Male G1/4 Quick Connect 1/2 NPT Male G1/4 Male Flat Long 7/16-20 UNF Female Depth Cone (G1/4 Female) 7/16-20 UNF Male Short Flat Other pressure connectors may be available. Contact GE to discuss your requirement. Electrical Connector Code Number Description Max Operating temp range C F 0 No Connector -55 to +125-67 to +257-1 Polyurethane Cable -40 to +80-40 to +176 65 2 Raychem Cable -55 to +125-67 to +257 65 3 Polyurethane Depth -40 to +80-40 to +176 68 4 Hytrel Depth -40 to +80-40 to +176 68 6 MIL-C-26482-55 to +125-67 to +257 * C 1/2 NPT Conduit -40 to +80-40 to +176 67 G M12 X 1 5-pin -55 to +125-67 to +267 * H PTFE Cable (Orange) -55 to +125-67 to +267 54 IP rating Note: Hermetically sealed connectors with a maximum leak rate of 1 x 10-6 cc/s at 1 Atmosphere. High IP rated mating connectors are available.

Connection Details Option Code Connection Function Flying Leads CABLE 1, 3, 4, C Frequency & Diode Digital- RS485 0 RED SUPPLY SUPPLY YELLOW FREQ RS485 B Rx GREEN TEMP RS485 A Tx Digital - RS232 SUPPLY BLUE GROUND GROUND GROUND BLACK -VE TEMP - - ORANGE EEPROM - - RED SUPPLY SUPPLY YELLOW FREQ RS485 B Rx BLUE TEMP RS485 A Tx SUPPLY WHITE GROUND GROUND GROUND BLACK -VE TEMP - - ORANGE EEPROM - - SCREEN - - - RAYCHEM 2 RED SUPPLY SUPPLY WHITE FREQ RS485 B Rx GREEN TEMP RS485 A Tx SUPPLY BLUE GROUND GROUND GROUND BLACK EEPROM - - SCREEN - - - MIL-C 6 A SUPPLY SUPPLY B FREQ RS485 B Rx C TEMP RS485 A Tx SUPPLY D GROUND GROUND GROUND E EEPROM - - F -VE TEMP - - M12 G 1 SUPPLY SUPPLY 2 FREQ RS485 B Rx SUPPLY 3 GROUND GROUND GROUND 4 TEMP RS485 A Tx 5 EEPROM - - PTFE H RED SUPPLY SUPPLY YELLOW FREQ RS485 B Rx GREEN TEMP RS485 A Tx SUPPLY BLUE GROUND GROUND GROUND BLACK EEPROM - - WHITE -VE TEMP - - SCREEN - - - Certification CE Marked RoHS EMC Standards BS EN 61000-6-1: 2007 Susceptibility - Light Industrial BS EN 61000-6-2: 2005 Susceptibility - Heavy Industrial (except mv versions) BS EN 61000-6-3: 2007 Emissions - Light Industrial BS EN 61000-6-4: 2007 Emissions - Heavy Industrial BS EN 61326-1: 2006 Electrical Equipment for Measurement, Control and Laboratory Use - EMC requirements BS EN 61326-2-3:2006 Requirements for pressure transducers

Mechanical Drawings 8 (0.31) 78 (3.07) DRUCK LTD. GR #### 81## S/N ******* *** TO *** ba Supply: *** T Output: *** T Temp. Range: RPS800 PRESSU MALE PRESSURE CONNECTION MEDIUM PRESSURE CONSTRUCTION POLYURETHANE CABLE IP65 ( 22 A/F) (0.86) 7 (0.27) 21 TYP (0.82) 22 A/F (0.86) RAYCHEM CABLE 14.5 (0.57) 42 (1.65) 32 (1.25) 60 (2.36) Ø25 FEMALE PRESSURE CONNECTION 1/2 NPT CONDUIT WITH POLYURETHANE CABLE POLYURETHANE CABLE (DEPTH) HYTREL CABLE (DEPTH) ( 22 A/F) 16 (0.62) 15.5 (0.61) 7 (0.27) 15 TYP (0.53) DEPTH CONE PRESSURE ADAPTOR M12x1 5-PIN PTFE CABLE (ORANGE) 25 TYP 17 (0.66) OPTIONAL WELDED PRESSURE ADAPTOR Ø25 OTHER PRESSURE CONNECTOR DETAILS AVAILABLE ON REQUEST NO ELECTRICAL CONNECTOR (FLYING LEADS) MIL-C-26482 (6 PIN SHELL SIZE 10) Notes: 1. All dimensions are nominal lengths and are subject to change. 2. All dimensions are in millimeters (inches). 3. Other pressure and electrical connectors may be available, please contact GE.

(1) Select model number Main Product Variant RPS Resonant Pressure Sensor - Frequency & Diode Output (Note 1) DPS Digital Pressure Sensor - Digital Output (Note 1) Product Series 8 RPS/DPS 8000 Series Diameter, Material and Isolation 1 25mm Stainless Steel Silicon Exposed Electrical Connector 0 No Electrical Connector (Flying leads) 1 Polyurethane Cable 2 Raychem Cable 3 Polyurethane Cable (Depth) 4 Hytrel Cable (Depth) 6 MIL-C-26482 (6-pin Shell Size 10) C 1/2 NPT Conduit with Polyurethane Cable G M12x1 5-Pin H PTFE Cable (Orange) Output Option 0 Frequency & Diode (Low Power <3.5 ma) 1 Frequency & Diode (Low Jitter aprox 75 ns) A RS485 B RS232 Compensated Temperature Range TA -10 to +50 C TB -40 to +85 C Accuracy A1 - Standard 0.02% A2 - Improved 0.01% Calibration CC Full Thermal Calibration Hazardous Area Approval H0 None Pressure Connector PA G1/4 Female PB G1/4 Male Flat PC G1/4 Male 60 degree internal Cone PD G1/8 Male 60 degree internal Cone PE 1/4 NPT Female PF 1/4 NPT Male PG 1/8 NPT Male PH M20x1.5 PJ M14x1.5 60 Internal Cone PK M12x1 Internal Cone PL 7/16-20 UNJF Male 74 degree external cone PN G1/2 Male PQ G1/4 Quick Connect PR 1/2 NPT Male PT G1/4 Male Flat Long PV 7/16-20 UNF Female) PW Depth Cone (G1/4 Female) PX 7/16-20 UNF Male Flat R 8 0 4 1 - TA - A2 - CC - H0 - PA Typical Model Number Note 1: RPS variants require Output Option Code 0 or 1. DPS variants require Output Option Code A or B..

2) State pressure range and units: e.g. 0 to 20 bar, 0 to 100 psi Unit options are: Symbol bar mbar psi Pa hpa kpa MPa mmh 2 O cmh 2 O mh 2 O inh 2 O fth 2 O mmhg inhg kgf/cm 2 atm Torr Description bar millibar pounds/sq. inch Pascal hectopascal kilopascal megapascal mm water cm water metres water inches water feet water mm mercury inches mercury kg force/sq. cm atmosphere torr 3) State cable lengths and units: e.g. 1 m cable, 8 ft cable (only required on certain electrical connectors) Typical order examples: RPS 8110-TA-A1-CC-H0-PA, 3.5 bara, 5 m cable DPS 816A-TB-A2-CC-H0-PL, 750-1,150 mbara

www.ge-mcs.com 920-565B 2013 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.