HP Carrier Grade Server cc3310 AC/DC Power Supply and DC Cable Installation. For the cc3310 Carrier Grade Server



Similar documents
About this Manual. Support for Your Product

hp digital home networking wireless USB network adapter hn210w quick start guide

HP OpenView Patch Manager Using Radia

Support Plus User Guide HP-UX Version 11.00

Wall-Mounting your HP computer. User Guide

WHITE PAPER. HP Guide to System Recovery and Restore

Web Enabled Software for 8614xB-series Optical Spectrum Analyzers. Installation Guide

Compaq Presario Desktop Products. Upgrading and Servicing Guide

The power module is Feature Number 8800-F2-901.

HP UPS R1500 Generation 3

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

HP StorageWorks EVA Hardware Providers quick start guide

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

StorTrends 3400 Hardware Guide for Onsite Support

RDC-7 Windows XP Installation Guide

Agilent N9911X Economical Waveguide Calibration Components

HP ProLiant DL165 G7 Server. Installation Instructions

HP 16/18-Port Cable Management Kit Installation Guide

Keysight N9911X Economical Waveguide Calibration Components

Small form factor bay converter and hard drive installation

Intel Device View. User Guide

HP OpenView Adapter for SSL Using Radia

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

UPGRADING AND SERVICING GUIDE

Upgrading and Servicing Guide

2-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

HP CIFS Server and Encrypting Client Connections

HP Netserver/Server Server Management Reference Guide

Database Client/Server

5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

Agilent OpenLAB. Data Store. Disaster Recovery Plan

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Triple Expansion Chassis

High Availability Server Hardware v0.5 MB-draco-batentaban-0.5

HP LaserJet 4050 and 4050 N Printers Getting Started Guide. English

24.2L M.A.N. V12 Engine Module

HP Classroom Manager. Software Installation and Setup Quick Start Guide. HP Part Number: NW281AA

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR³ DATALINK INSTALLATION INSTRUCTIONS Manual , Rev. B

MetaXpress Image Acquisition and Analysis Software Version 3.1

DCX300 - DCX400 - DCX600

CA Nimsoft Monitor. Probe Guide for CPU, Disk and Memory. cdm v4.7 series

HP ProCurve Manager Plus

Commonwealth of Pennsylvania Software License Requirements Contract # Tab Software

Software Update, Backup, and Recovery

HP 22-in-1 Media Card Reader

Dell Spotlight on Active Directory Server Health Wizard Configuration Guide

Hardware/Software Specifications for Self-Hosted Systems (Multi-Server)

How To Install A Power Supply (Uplast) With A Battery Pack

ProCurve Networking. Troubleshooting WLAN Connectivity. Technical White paper

TotalShredder USB. User s Guide

Nimsoft Monitor. sysloggtw Guide. v1.4 series

Symantec Enterprise Security Manager Oracle Database Modules Release Notes. Version: 5.4

HP OpenView Network Node Manager

HP Client Manager 6.1

Spotlight Management Pack for SCOM

HP Client Manager 6.2

Printer Driver Installation Manual

QUICK GUIDE FOR. Installing Nokia Connectivity Cable Drivers

Memory Modules User Guide

HP R12000 and R18000 DirectFlow UPS User Guide

Adaptec Event Monitor Utility. User s Guide

MetaXpress High Content Image Acquisition & Analysis Software

EView/400i Management Pack for Systems Center Operations Manager (SCOM)

Vivax Storage Server

USB to IDE or SATA Adapter

RAID 1(+0): breaking mirrors and rebuilding drives

CA Nimsoft Monitor Snap

910 Series Photo Jetprinter. Setup Solutions

capacity management for StorageWorks NAS servers

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

SOLARWINDS, INC. ipmonitor 8.0 MANAGER END USER LICENSE AGREEMENT REDISTRIBUTION NOT PERMITTED

Symantec Mobile Management for Configuration Manager

Dell One Identity Cloud Access Manager How to Configure vworkspace Integration

Getting Started. rp5800, rp5700 and rp3000 Models

hp StorageWorks DS-KGPSA-CA/CX and FCA2354 PCI host bus adapters

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number VERIZON

NECCare TM. NECCare Hard Disk Drive Retention Program. Express5800/Servers & M-Series SANs. HDD Retention 10/27/14

281A/B Adapters. Operating and Service Manual

HP dx5150 RAID Installation and Setup Guide Version Document Part Number:

About Your NetBotz 4-20mA Sensor Pod

About the BitStorm 6051 POTS Splitter

IP DSLAM IDL Quick Installation Guide

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

In-Situ Inc. Warranty / Terms & Conditions / Software License. This warranty policy applies to items that shipped prior to January 1, 2012.

FlightMax Flight Situation Display

Symantec Backup Exec System Recovery Granular Restore Option User's Guide

HP LeftHand SAN Solutions

Symantec Security Information Manager - Best Practices for Selective Backup and Restore

USB to RS232 Adapter User s Manual

Symantec Mail Security for Microsoft Exchange Management Pack Integration Guide

OfficeConnect Internet Firewall 25 Internet Firewall DMZ. QuickStart Guide (3C16770, 3C16771)

A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000

Automated Database Backup. Procedure to create an automated database backup using SQL management tools

ShadowProtect Recovery CD Restore Wizard Options

HotLok Pass Through Blanking Panel

HP Optical Bay Hard Drive Bracket

Using hp OpenView Omniback II GUI Via Slow Remote Connections

Transcription:

HP Carrier Grade Server cc3310 AC/DC Power Supply and DC Cable Installation For the cc3310 Carrier Grade Server Manufacturing Part Number: AB229-90001 July 2004 U.S.A. 2004, Hewlett-Packard Development Company, L.P.

Legal Notices The information in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material. Restricted Rights Legend. Use, duplication or disclosure by the U.S. Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013 for DOD agencies, and subparagraphs (c) (1) and (c) (2) of the Commercial Computer Software Restricted Rights clause at FAR 52.227-19 for other agencies. HEWLETT-PACKARD COMPANY 3000 Hanover Street Palo Alto, California 94304 U.S.A. Copyright Notice. Copyright 2004 Hewlett-Packard Development Company, L.P. Reproduction, adaptation, or translation of this document without prior written permission is prohibited, except as allowed under the copyright laws. All rights reserved. Printed in the U.S.A. Related Documents. The HP Server cc3310 User Information Diagnostics and Utilities Resource CD-ROM has been provided with your server. It contains a complete documentation set for the server. Included on the CD-ROM is the hp Carrier-Grade Server cc3310 Product Guide, which contains in-depth troubleshooting, installation, and repair information. In addition, the latest versions of all cc3310 documents, and any product updates to these documents, are posted under the appropriate server at: http://docs.hp.com. Search keyword cc3310. 2

Reprogramming the SDR Reprogramming the SDR NOTE The systems Sensor Data Records (SDR) must be reprogrammed every time the hardware configuration changes (any changes to memory, processors, power supplies, power cage, hot swap back plane, controller boards, or any hardware devices or Field Replaceable Units (FRU). Failure to reprogram the SDR may allow critical systems failures to occur without the appropriate Telco alarm. Use the following procedure to re-write the SDR after a hardware change has been installed: 1. Boot the system using the HP Server cc3310 User Information Diagnostics and Utilities Resource CD. 2. Once the CD has booted, select Load Configuration Wizard. 3. When the Load Configuration Wizard begins, press Continue. 4. Select Server Configuration Wizard and Continue. 5. Select run wizard and Continue. 6. Select only the Load SRD s only on to this server and Continue. 7. Set the date and time and select Continue. 8. Select update just the SDR repository and Continue. 9. Select Yes Activate BMC TAM and Continue. 10. Choose any LED configuration you want and select Continue. 11. Save the server configuration to disk if you desire. 3

Power Supply Installation/HP DC Cable AC and DC Power Supply Installation Follow the Power Supply installation procedures presented in the cc3310 Product Guide (Chapter 7), which is provided on the HP Server cc3310 User Information Diagnostics and Utilities Resource CD. (Look under the Documentation tab.) After the additional power supply has been installed, reprogram the SRD as described in the preceding paragraph (Reprogramming the SDR). Figure 1-1. AC Power Connections on Server AC Recepticles Figure 1-2. DC Power Connections on Server DC Terminal Block HP DC Power Cable A6900-63002 A DC power cable is available from HP for use with the cc3310 Server. This cable is 14 feet in length and includes lugs on 1 end (Network TM stock # 81N1501 type CRS-TO-1406-HT) for connection with the server power supply. The other end of this cable is unterminated. All wires are tagged to match power supply terminal block nomenclature. 4

Fabricating/Connecting a DC Cable Fabricating a DC Cable If you will be creating a cable for use with the cc3310 server, you must utilize the correct number and size wires and lugs for connection with the server. A DC power terminal block is provided at the rear of each DC power supply. Your cable must connect to these terminals. For best results (to meet maximum current requirements) all four terminals of the terminal block (2+ and 2 ) should be used. Each terminal is rated for 15 Amps. Use 14 AWG wire gauge (minimum) and suitable terminal lugs. The terminal block will accept standard terminal lug size Network TM stock #81N1501 type CRS-TO-1406-HT that accept 14 AWG wire gauge. The width of the lug can be no more than 0.25 inches. Figure 1-3. Typical Terminal Lug 0.6" 0.25" 0.2" NOTE: Terminal lug width should not exceed 0.25 " lug Connecting DC Power Cable to Your Server NOTE It is important that the connection details are followed to prevent damage to the cc3310 power supply. The power supply design incorporates current splitting in the terminal design which requires proper input power connection. It is also important to note that each power supply requires its own separate power cable with all four terminals connected/wired as indicated in the following diagram. 5

Connecting DC Power Cable Figure 1-4. DC Power Supply Terminal Block HP Server cc3310 DC Power Input Pin Assignments cc3310 DC Terminal Block Both of the minus ( ) terminals should be connected to 48V (right side). Both of the plus (+) terminals should be connected to return (left side). To meet the maximum current requirements, 2 pins are used for return and 2 pins are used for 48V. Each pin is rated for 15 Amps (maximum). To connect the earth ground conductor to the chassis stud, proceed as follows: 1. Place a #8-32 nut on the chassis stud and tighten to 10 in-lbs. 2. Place the earth ground wire terminal lug on the chassis stud. 3. Place another #8-32 nut on the chassis stud so that the earth ground wire terminal is between the two nuts. Tighten the second nut to 10 in-lbs. To connect the power cable to the DC terminal block, proceed as follows: CAUTION For proper cooling and airflow, do not operate the server with the cover removed. Always reinstall the cover before turning the server on. 1. Verify that the power cord is not connected to a power source. 2. While referring to Figure 1-4, connect the power cable wires to the terminals of the power supply terminal block. 3. Connect the power cable to a suitable ( 48V) power source. 6