OPERATING AND MAINTENANCE INSTRUCTIONS CLIMATE CONTROL/INDUSTRIAL



Similar documents
ATLAS AIR COMPRESSOR OPERATING INSTRUCTIONS COMPRESSOR IDENTIFICATION

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Chapter 7 Hydraulic System Troubleshooting

Trouble Shooting. Pump

Table Z. Troubleshooting Chart for Air Conditioners. Cause

3620 W 11th Streetб Houston, TX Telephone: sales@kellogg-american.com Website:

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

Belt Driven Compressors

Hydraulic Trouble Shooting

Instruction Manual. Manual No July 2003 Edition

INSTALLATION AND OPERATION MANUAL. Bend - Pak Inc Lemonwood Drive Santa Paula, CA 93060, U.S.A Tel: Fax:

Hydraulic Troubleshooting PRESENTED BY

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Hydraulics Trouble Shooting Guide. TS-Guide_R.doc

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Owners Manual HP Electric Reciprocating Compressor

Oil and Coolant Circulating Heating System. Model - OCSM

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

accidents which arise due to nonobservance and the safety information herein.

BOWIE PUMPS OPERATION - MAINTENANCE

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

PC1131 Electric Air Compressor

PC1130 Electric Air Compressor

Compressor Service & Maintenance Manual

CARING FOR YOUR WATER HEATER

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Engine, Drive Train, and Hydraulic Repair Indicator Quick Reference Guide

Quincy QR-25 Series. Instruction Manual

Pump Maintenance - Repair

13. REAR WHEEL/BRAKE/SUSPENSION

2 Stage Compressors. Instruction Manual

INSTALLATION & OPERATING INSTRUCTIONS

AC Electric Motors best practice

Unit: mm(in) Item Standard value Service limit Axle shaft run out - 0.2(0.008)

Class 5 to 7 Truck and Bus Hydraulic Brake System

STEERING SYSTEM - POWER

Float and Thermostatic Traps Series H, C and X

SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006

HYDRAULIC LIFT TABLE CART 2200-LB.

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

Rexroth Hydraulic Pump A10VO Series User Manual

Panel Mounted Air Conditioners by Dantherm, Inc.

Installation, operation and maintenance manual

AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller

TROUBLESHOOTING GUIDE

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

ENGINE COOLING SYSTEM

Rotary Lift Trouble Shooting Guide

2 HP / 4 GALLON AIR COMPRESSOR OWNER'S MANUAL

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

Railgates By THIEMAN IMPORTANT! KEEP IN VEHICLE! PLEASE READ AND UNDERSTAND THE CONTENTS OF THIS MANUAL BEFORE OPERATING THE EQUIPMENT.

tire inflator with pressure gauge

ROTARY TUMBLER INSTRUCTIONS AND PARTS LIST

MODEL INSTALLATION INSTRUCTIONS

ROTARY TUMBLER INSTRUCTIONS AND PARTS LIST

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Engine Troubleshooting Guide Shortcuts to Costly Engine Diagnostics

Tri-Homo Style Operation and Maintenance Instructions

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

SERVICE DIAGNOSIS Modine heating & ventilating equipment

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Owner s Manual. Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE

NITROUS TRANSFER PUMP INSTRUCTIONS

How Do I Replacing My Rear Brake Pads and Rotors?

MAINTENANCE INSTRUCTIONS FOR THE CLEAN-FLO CONTINUOUS LAMINAR FLOW INVERSION / OXYGENATION SYSTEM

LOBOY 16 AIR CONDITIONERS

PUMP MAINTENANCE SCHEDULE AND CHECKLISTS

OPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE

COOLING SYSTEM Section Page

SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)

A Guide to Trouble-Free Cooling Towers

Why and How we Use Capacity Control

15GAL STEEL OIL DRAIN WITH 110V PUMP

ELECTRIC MOTOR TEFC OPERATION & MAINTENANCE. meps Approved

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

WE-350 Series ¼ Turn Electric Actuator

Fuel Injection Pump, Rotary ( )

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

BERMAD Fire Protection

AIR COMPRESSOR. Model SET UP AND OPERATING INSTRUCTIONS. Visit our website at:

SERVICE BULLETIN AIR CONDITIONER COMPRESSOR FAILURES ALSO SEE BULLETIN #SB3-304AS (SYSTEM CONTAMINATION)

SunMaxx Solar Filling Station Operating Instructions

SERVICE GUIDE For WARN PULLZALL 120v AC &100v AC P/N &

Technical Guide 08/15/14

DiscPlus DX195 and DX225 Air Disc Brakes

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual

Preventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services

11. COOLING SYSTEM 11-0 COOLING SYSTEM BET & WIN 50

Hydraulic control unit series

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Federal Wage System Job Grading Standard for Air Conditioning Equipment Mechanic, Table of Contents

BERMAD Fire Protection

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

HVAC Preventative Maintenance Basics. Presented by Mike Crawley

BUYERS GUIDE. IMPORTANT: Spoken promises are difficult to enforce. Ask the dealer to put all promises in writing. Keep this form.

Transcription:

OPERATING AND MAINTENANCE INSTRUCTIONS CLIMATE CONTROL/INDUSTRIAL PERFORMANCE UNDER PRESSURE 2362 Emerson Street Jacksonville, Florida 32207 (800) 394-5575 (904) 396-5575

A Message from the President Air Compressor Products, Inc. (ACP) was established in 1973 to manufacture compressed air systems and related products. We have over forty years experience in the compressed air industry arid our total quality commitment and on-going development provide the background for our technically advanced products. We know that a company s greatest asset is its ability to provide genuine service to its customers. Our mission is to continually improve our products and services in order to meet our customer s needs. This has established Air Compressor Products as an innovative industry leader in the manufacture, development and application of products for compressed air systems. Our products are built for value, safety and long lasting performance. Our modern manufacturing facilities have the flexibility to meet the market needs for both standard and special compressor packages. ACP breathing air and climate control products are recognized worldwide. Our goal is to provide you with products and service second to none. Sincerely, Air Compressor Products, Inc. Greg Walski CEO FAILURE TO READ THIS MANUAL BEFORE INSTALLING AND OPERATING YOUR NEW AIR COMPRESSOR COULD RESULT IN INJURY, PROPERTY DAMAGE, AND/OR EQUIPMENT FAILURE. FREIGHT DAMAGE Freight damages do not constitute warranty service. ACP terms are FOB point of shipment (plant), and ACP s responsibility ceases upon delivery of product to carrier and obtaining receipt for same. It Is the responsibility of the receiving customer to file damage or concealed damage claim with the delivering carrier upon receipt or product. 1

INDE PAGE 1 LETTER FROM ACP PRESIDENT SAFETY WARNING FREIGHT DAMAGE 2 INDE 3 INSTALLATION 4 PREPARING TO START STARTING 5 STOPPINGFORMAINTENANCE LUBRICATION 7 BELT TENSION ADJUSTMENT PERIODIC MAINTENANCE CHART 8 TROUBLESHOOTINGCHART 12 LONGTERMSTORAGE 13 TORQUESPECIFICATIONS 2

INSTALLATION LOCATION Locate the compressor in a dry, clean, cool and well ventilated area. If the compressor must be mounted in areas which are poorly ventilated or have dirt, vapors or volatile fumes in the atmosphere, install a remote air intake system. These conditions may cause faulty operation due to clogged intake filters and valves or they can cause moisture to accumulate in the systems air lines. NOTE: Maximum ambient temperature in which the compressor and motor should be operated is 104 F. The compressor must not be installed closer than twelve (12) inches to a wall or to another compressor to allow ample circulation of air across the compressor cylinders and heads. Additional safety can be achieved by locating the pulley system, with the guard, on the wall side. Mounting - Mount the compressor on a concrete pad or floor making certain that the receiver feet are level and that no stress is induced in the legs when the mounting nuts ate tightened, shim feet if necessary. Severe vibrations will result when feet are uneven and drawn tightly to the pad which can lead to welds cracking or fatigue of the receiver. Induction System - Avoid locating the air inlet system where it could ingest toxic, volatile or corrosive vapors, air temperatures exceeding 120 F, water or extremely dirty air. Ingesting any of the above noted atmospheres by the compressor will impair the performance of the equipment. 3

PREPARING TO START FAILURE TO MAKE THESE RECOMMENDED CHECKS COULD RESULT IN SERIOUS INJURY, PROPERTY DAMAGE, AND MECHANICAL FAILURE. 1. Remove all loose pieces and tools around the compressor installation. 2. Check oil level in crankcase. 3. Check motor and compressor pulley for alignment and tightness on shaft 4. Be absolutely certain that all mounting bolts are tight. 5. Manually rotate compressor through enough revolutions to be certain there are no mechanical interferences. 6. Check belt tension, it should be neither too loose nor too tight. 7. Check all pressure connections for tightness. 8. Check to make sure all safety relief valves are in place. 9. Check to be sure all guards are in place and securely mounted. 10. Check fuses, circuit breakers and thermal overloads for proper size. 11. Open all manual shutoff valves (block valves) at and beyond the compressor discharge. 12. After all of the above conditions have been satisfied, jog the starter switch button to check the rotational direction of the compressor, it should agree with the rotation arrow on the unit. STARTING Follow this procedure for start up of a new installation, after changes to an existing installation have been made, and after service or repairs have been performed. 1. Instructions in addition to those contained within this manual, supplied by manufacturer of support equipment, must also be read and understood before start-up. 2. Jog starter button and check compressor rotation. 3. Start compressor and watch for excessive vibration and noises. If either is present, stop compressor and correct. 4. Check air receiver pressure. 5. Manually blow safety relief valve(s). 6. Check operation of controls. 7. Observe general compressor operation closely for first hour and then frequently for next seven hours. If any abnormal conditions exist, stop compressor and correct the problem. 8. After two days of operation, check belt tension, air and oil piping for leaks and crankcase oil level. DUPLE UNITS: NOTE: It is strongly recommended when starting duplex units both compressors be put on line in the alternating mode. When running only one unit for a long period of time there is a tendency due to heat generated by the operating compressor for the stand-by compressor to condense moisture in the head causing fist. When both units are operating equal heat keeps the moisture suspended. 4

STOPPING FOR MAINTENANCE NEVER ASSUME THE COMPRESSOR IS READY FOR MAINTENANCE OR SERVICE BECAUSE IT IS STOPPED. THE AUTOMATIC STOP-START CONTROL MAY START THE COMPRESSOR AT ANY TIME. I The following procedures should be followed to maximize safety when preparing for maintenance or service. 1. Disconnect and lock-out the main power switch and hang a sign at the switch informing of the unit being serviced. 2. Close shut-off valve (block valve) between receiver and compressor, or receiver and plant air system, to prevent any back-up of air flow into the area to be serviced. 3. Lock open manual vent valve and wait for the pressure in the area to be serviced (compressor, receiver, etc.) to be completely relieved before starting service. The manual vent valve may be the drain valve in the receiver. NEVER remove a plug to relieve the pressure. 4. Shut off water and depressurize system if it is water cooled. 5. Open all manual drain valves within the area to be serviced. CAUTION: When maintenance has been completed, refer to the starting procedure section of this manual for restarting the unit. MAINTENANCE AND SERVICE LUBRICATION In order to insure proper lubrication the compressor must not be run at a speed lower than 400 RPM or faster than the maximum as stipulated so as to avoid rapid wear of the parts. Always keep oil level In between the H and L lines or the oil gauge (as shown). Standard Oil Level Oil Gauge Do not over fill. The oil level must be maintained as noted above. Never allow oil to fall below L Level. Change oil after first 100 hours of operation and every 1000 hours thereafter, (every 500 hours when the condition of the oil dictates more frequent changes). Fill crankcase only when compress is shut down. 5

The lubricant should be a premium quality. NON DETERGENT OIL, containing a rust and oxidation inhibitor. Utilization of an improper oil may result in coking which on build-up may plug heat exchangers, control lines, compressor valves and safety relief valves, resulting in a fire or explosion. For proper viscosity refer to the table below. AMBIENT TEMPERATURE AT POINT OF INSTALLATION 0 F. TO 32 F. 32 F. TO 80 F. ABOVE 80 F. SAE VISCOSITY ISO VISCOSITY GRADE SAE l0w SAE 20W SAE 30 ISO 32 ISO 46/68 ISO 100 NOTE: All reciprocating compressors have a tendency to pass higher than normal amounts of oil out the discharge port when new. This is because the piston rings need to conform to the cylinder walls. Allow 100 hours running time at full discharge operating pressure for piston ring break-in. Do not use a higher viscosity oil than is specified in the table above. COMPRESSOR OIL CAPACITY New ACP Part# Old ACP Part # Old CC Part # New CC Part # Oil Capacity SINGLE STAGE ACP-GS02 ACP-GS-0 C0S C0S 12 oz. ACP-GS11 ACP-GS12 ACP-GSA-0 ACP-GSA-1 C0S A C1S C1S 21.4 oz. 21.4 oz. ACP-GS13 ACP-GS22 ACP-GS-l2 ACP-GS-35 C2S C3S C2S C3S 37.2 oz. 32.9 oz. ACP-0S23 ACP-GSA-35 CSS C4S 57.1 oz ACP-GS33 ACP-GSA-7510 C6SA C5SB 85.5oz. ACP-GS33 ACP-GS43 ACP-GS-75l0 ACP-GS-15 C6SA C7S C6S C7S 85.5 oz. 152.6 oz. TWO STAGE ACP-G12 ACP-G13 ACP-G-1 ACP-GA-l23 C2T C2T 21.4 oz. 37.2 oz. ACP-G23 ACP-G33 ACP-G-35 ACP-G-7510 C4T 57.1 oz 85.5 oz. ACP-G43 ACP-G-15 152.6 oz. ACP-G54 ACP-GH-2025C 202.3oz. ACP-GB1 ACP-GB1 ACP-GB2 ACP-GB2 6

BELT TENSION ADJUSTMENT To change tension, loosen the motor hold-down bolts and slide the motor on the base, using a lever if necessary, or by turning the adjusting bolt at the end of the base. Retighten motor hold-down bolts. NOTE: Do not over tighten belts. CHECK 1. Check Low oil level. Maintain between High and level masks on gauge. CAUTION: Do not overfill! 2. Drain moisture accumulation from the air receiver. 3. Drain drop legs and u in air distribution system. 4. Give compressor an overall visual inspection and be sure safety guards are in place. 5. Check for any unusual noise or vibration. 6. Check for oil leaks. 7. Operate the safety valves to be certain they are functioning. 8. Clean the cooling surfaces of the intercooler, aftercooler and compressor. 9. Replace more or clean air intake filter. Check more often if dirty conditions exist. 10. Check the air distribution system for air leaks. 11. 11. Inspect oil for contamination and change if necessary. Check more often under dirty conditions. 12. Check belt tension. 13. Check pulley and pulley clamp screws or set screws for tightness. 14. Inspect compressor valves. 15. Inspect pressure switch diaphragm and contacts. Also contact points in motor starter (if supplied). PERIODIC MAINTENANCE CHART Daily Weekly Monthly Semi- Annually Annually 7

Trouble Low discharge pressure and air delivery. TROUBLE SHOOTING Probable Cause Restricted air inlet filter or suction line. Bad compressor valves or valve unloading mechanism. Leaks in the plant air system at fittings, connections, tools, etc. Unloader pilot set wrong or bad. Pressure switch set wrong or bad. Drive belt slipping. Incorrect speed. Worn piston rings or loose piston. Leaking head gasket. Drain valve open. Bad pressure gauge. Demand exceeds capacity, compressor not sized properly. Safety valve leaking. Loose compressor valves or leaking at valve gaskets. Valves or piston rings not seated. Water in the crankcase Compressor does not run long enough to get hot and vaporize the moisture squeezed out of the air during compression. Compressor may be too large for the application. Leaking cylinder head. Detergent oil being used. System pressure leaking back through valve. 8

Trouble Rusty valves and/or cylinders. TROUBLE SHOOTING (Continued) Probable Cause Compressor operated too infrequently. Compressor does not run enough to get hot and vaporize the moisture squeezed out of the air during compression. Not properly processed for storage. Excessive belt wear. Pulleys out of alignment. Belt too loose or too tight. Belt slipping. Pulley wobbling. Pulley groove damaged or rough. Excessive vibration. Incorrect speed. Compressor valves not functioning properly. Pulley loose. Motor or engine out of balance. Compressor, motor or engine not secured tightly, or tightened in a bind. Excessive discharge pressure. Compressor loads and unloads excessively. Air storage capacity too small. Compressor valves or unloaders bad. Excessive system leakage. Incorrect speed. Unloader pilot differential set too close. 9

Trouble Air receiver pressure excessive. TROUBLE SHOOTING (Continued) Probable Cause Air pressure gauge inaccurate. Leaks in unloader piping system. Compressor valve unloader bad. Unloader pilot or pressure switch set improperly, or bad. Compressor overheats. Defective compressor valves. Pressure setting too high. Clogged Intercooler, internally or externally. Inadequate ventilation or recirculation of hot air. Pulley rotation wrong. Incorrect speed. Running clearances insufficient, piston to cylinder wall or running gear. Lubrication inadequate. Compressor knocks. Head clearance insufficient. Piston loose in cylinder bore, cylinder bore worn, piston or piston rings worn. Worn connecting rod bearings. Worn main bearings. Excessive crankshaft end play. Pulley loose. Compressor valve assemblies loose. High air discharge temperature Compressor valve assemblies bad. Air discharge pressure too high. Inadequate ventilation or hot air recirculating. Cooling surfaces of compressor or Intercooler excessively dirty. Ambient temperature too high. Scored or excessively worn cylinder walls. 10

Trouble Excessive oil consumption. Worn piston rings. Air intake restricted. Compressor running too hot. Breather valve not functioning properly. Oil level in crankcase too high. Oil viscosity wrong for the application. Connection rod Out of alignment, bent or twisted. Leaking oil seal. Excessive current draw. Low voltage. Failure to start. TROUBLE SHOOTING (Continued) Probable Cause Running unloaded too long. Piston rings not seated. Allow 100 hours for seating. Wrong oil, may be a detergent oil with a tendency to foam, etc. Loose electrical connection. Wire size too small. Motor too small. Air discharge pressure too high.bearings tight or seizing. No crankshaft endplay. Compressor speed too high. Motor bad. Compressor not unloaded. Power not on. Blown circuit fuse or circuit breaker tripped. Thermal motor overload tripped. Low voltage. Faulty start switch. Power failure. Pressure switch misadjusted or inoperable. Loose or broken wire. Motor bad. Compressor not unloading. 11

Motor stalls. Trouble Duplex will not alternate. Constant air bleed from pressure switch. TROUBLE SHOOTING (Continued) Probable Cause Motor overloaded. See Excessive current drawn in this section. Alternator relay loose in the socket. COMP1/ALT/COMP2 switch not in ALT mode. Pressure switch Improperly adjusted. No voltage to respective starter. Thermal motor overload tripped. Bad alternator relay. Motor bad. Worn or damaged pressure switch diaphragm. Pressure switch bleeder valve stuck. Discharge check valve stuck or faulty. LONG TERM STORAGE A compressor unit should not be stored without proper preservation for more than six (6) weeks. This is not a hard rule as the location must be taken into consideration. In very damp climates compressors could be stored for one (1) to two (2) weeks and in very dry climates a compressor could be stored for ten (10) to twelve (12) weeks. PROCESSING A COMPRESSOR FOR ETENDED STORAGE: 1. Fill the crankcase with a preservative oil. 2. Remove the suction and discharge valve cover plates and spray preservative oil over valves. 3. Remove air filter and tape openings shut with moisture resistant tape or plug with plastic pipe plugs. 4. Disconnect discharge pipe between compressor and air receiver. Tape or plug openings in compressor and air receiver the same as in step 3. 5. Cover entire unit with plastic covering to keep out moisture and to keep dust and dirt off unit. 12