55-Gallon Dispenser Package

Similar documents
Extrusion Flo-Valve INSTRUCTIONS-PARTS LIST psi (210 bar) Maximum Working Pressure. Model , Series K. Rev.

Instructions. Complete RPS 2900 Pump Kit for RoadLazer RoadPak Line Striping System 3A1304A ENG. Pressure Relief Procedure.

Fluid Regulator. Instructions Parts List L LOW PRESSURE

Feed Pump and Agitator Kits

Instructions Parts List

Leak Detection System

- For pumping exact amounts of lubrication fluids from a reservoir to specific lubrication points -

Battery Charger. Instruction Manual G

MODEL G300 BRAKE BLEEDER

OP300S / OP350 2:1 RATIO TRANSFER PUMP

Ultra-Lite In-Line Flow Gun

AIR CUT OFF KIT INSTALLATION INSTRUCTIONS

PAINT SPRAY GUN WASHER

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

Instructions -Parts List

BINKS MODEL 460 LIGHTWEIGHT AUTOMATIC SPRAY GUN

Graymills. Air Operated Double Diaphragm Pumps. Operations and Maintenance Instructions

Test Fixture, High Voltage Probe, and kv Meter

PET-10 INSTRUCTION MANUAL PRESSURE TANK

Parts. Ultra 395/495/595t Ultra Max II 490/495/595t V 120 VAC psi (228 bar, 22.8 MPa) Maximum Working Pressure.

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

PALLET JACK TON

Table of Contents WARNING SYMBOLS AND DEFINITIONS

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

GH 833 Sprayers C

IMPORTANT SAFETY NOTICE

Pump for Drywall Feed Pump System

15GAL STEEL OIL DRAIN WITH 110V PUMP

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

GM DURAMAX LMM Fuel Pickup Kit Installation Guide

BINKS SV100 CONVENTIONAL SUCTION FEED SPRAY GUN

Hydraulic Transmission Jacks Operating Instructions & Parts Manual

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

ADP Autoline 3A0986A ENG

15:1 Fire-Ball 300 Pumps

BINKS SG-2 PLUS TM 2 QT. PRESSURE CUPS

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

SINGLE STAGE INLINE FIRE PUMP

GAS SAFETY PRECAUTIONS

ROUGHNECK II Pumpless Drain

1000-LB. TRAILER JACK OWNER S MANUAL

8 ton air/hydraulic long ram jack

Owner s Manual & Safety Instructions

SunMaxx Solar Filling Station Operating Instructions

In-Line Filters and Coalescers with Automatic Drains

Customer Support

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

PNEUMATIC PLANISHING HAMMER

INSTRUCTION MANUAL IM042. Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Rexroth Hydraulic Pump A10VO Series User Manual

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

staple gun with 5/16 Long staples

The Storm 20-Gallon Wet/Dry Vac

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

INSTALLATION MANUAL MODEL RP-150

10 TON HYDRAULIC PRESS

3 WATT LED SPOTLIGHT Model No. SLM

Installation Manual DIAPHRAGM WELL TANK

TITAN 13 x 2 ½ BRAKES

1 / 4 IN. FFL x 4 FT. 9 IN. 1 / 2 IN. ACME x 4 FT. 9 IN. Gauge Accuracy +/-2% Set includes Quick Disconnect Valves

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

NITROUS TRANSFER PUMP INSTRUCTIONS

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

VOYAGER 570G. 744A Sprayer Control

HYDRAULIC TABLE CART

Instructions and precautions. Fork Height. Visit our website at:

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Voltmaster Trash Pumps Model TSP2, TSP3 and TSP4

Super Slider ADJUSTABLE FROM Model #HD26229

Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.

MODEL # Introduction

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Installation Guide Smart-UPS X External Battery Pack SMX120BP

DUST COLLECTOR 70 GALLON, 2 HP

AirPro Gravity Feed Airspray Gun

Micron-Master EL Series Fogger

RZ Guardrail System Installation Manual

POWER GEAR SLIDE OUT MANUAL

Stainless Steel Single and Dual Circulation Kits

GlasCraft Catalyst Pump

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Ceiling Mount Air Handler Manual

tire inflator with pressure gauge

Series Hose Reels

Unpacking, Installation, and Customization

National- Spencer Inc.

Owner s Manual & Safety Instructions

OAK WORKBENCH WITH 2 DRAWERS

Huskyt 716 Air -operated Diaphragm Pumps

123 Industrial Loop Road Paynesville, MN Phone:

Instructions Parts List

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

123 Industrial Loop Road Paynesville, MN Phone:

VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249

Installation Instructions

Transcription:

INSTRUCTIONS-PARTS LIST Husky 515 55-Gallon ispenser Package 08666 Rev. C INSTRUCTIONS This manual contains important warnings and information. REA AN KEEP FOR REFERENCE. 100 psi (6.9 bar) Maximum Air Input Pressure Model 21418, Series B ispense Package with Gun Model 21419, Series B ispense Package Table of Contents Warnings... 2 Parts rawings... 4 Parts Lists... 5 Installation... 6 Operation... 6 Service and Technical ata... 7 imensional rawing... 7 Warranty... 8 Graco Phone Number... 8 9294A Model 21418 shown

Symbols Warning Symbol This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions. INSTRUCTIONS EQUIPMENT MISUSE HAZAR Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury. This equipment is for professional use only. Read all instruction manuals, tags, and labels before operating the equipment. Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. o not alter or modify this equipment. Check equipment daily. Repair or replace worn or damaged parts immediately. o not exceed the maximum working pressure of the lowest rated component in your system. This equipment has a 100 psi (7 bar) maximum working pressure. Use fluids and solvents that are compatible with the equipment wetted parts. Refer to the Technical ata section of all equipment manuals. Read the fluid and solvent manufacturer s warnings. Always wear protective eyewear, gloves, clothing, and respirator as recommended by the fluid and solvent manufacturer. Comply with all applicable local, state, and national fire, electrical, and safety regulations. Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. o not expose hoses to temperatures above 180_ F(82_ C) or below --40_ F(--40_ C). o not lift pressurized equipment. 2 08666

FIRE AN EXPLOSION HAZAR Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. Ground all equipment and the equipment being dispensed to. Refer to Grounding on page 6. If there is any static sparking or you feel an electric shock while using this equipment, stop dispensing immediately. o not use the equipment until you identify and correct the problem. o not use kerosene or other flammable solvents or combustible gases to flush the unit. Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being dispensed. Keep the dispensing area free of debris, including solvent, rags, and gasoline. o not smoke in the dispensing area. Extinguish all open flames and pilot lights in the dispensing area. MOVING PARTS HAZAR Moving parts, such as the rotating blades of the agitator, can pinch or amputate your fingers or other body parts and can cause splashing in the eyes or on the skin. Keep clear of all moving parts when starting or operating the agitator. Always shut off the agitator and disconnect the air line before you remove the agitator from the drum or check or repair any part of the agitator. o not operate the agitator while an air line is hooked up to the elevator air fitting. Such operation could cause the agitator blades to turn while the elevator is raised, which could result in serious bodily injury or damage to the equipment from the hose getting tangled in the rotating agitator blades. TOXIC FLUI HAZAR Hazardous fluids or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, swallowed, or inhaled. When flushing the air motor or pump, keep your face away from the exhaust port. 08666

Parts rawing Husky 515 55-Gallon ispense Package with Gun, Model 21418, Series B Includes items 1 through 54 Husky 515 55-Gallon ispense Package, Model 21419, Series B Includes items 1 through 26 27 50 restrictor valve 24 2 19 18 25 12 16 10 elevator 11 air control valve 24 1 agitator needle valve 6 17 1 8 7 9 14 1 15 20 21 22 51 4 2 4 2 18 1 2 4 5 52 5 54 Husky 515 iaphragm Pump (see manual 08981) rum Cover Assembly (see manual 08466) Siphon Kit (see manual 08609) Elevator Assembly (see 06287) Heavy-uty SST rum Agitator (see manual 08609) 5 5 9295A 4 08666

Parts List Husky 515 55-Gallon ispense Package with Gun, Model 21418, Series B Includes items 1 through 54. Husky 515 55-Gallon ispense Package, Model 21419, Series B Includes items 1 through 26. Ref No. Part No. escription Qty. 1 241564 PUMP, Husky 515, acetal See manual 08981. 1 2 2828 RUM COVER ASSEMBLY See manual 08466. 1 28250 SIPHON KIT See manual 08609. 1 4 27746 ELEVATOR ASSEMBLY See manual 06287. 1 5 28157 RUM AGITATOR, heavy duty; SST See manual 08609. 1 6 191565 BRACKET, pump 1 7 191566 UNION, suction tube 1 8 191567 NUT, union, swivel 1 9 11575 O-RING, packing 1 10 111804 REGULATOR, air 1 11 111805 BLOCK, diverter 1 12 108190 GAUGE, air pressure 1 1 100086 WASHER, plain 4 Ref No. Part No. escription Qty. 14 100022 SCREW, cap 4 15 108094 NUT, lock 4 16 111821 SCREW, mach, hex head 1 17 111280 NUT, locking 1 18 156971 NIPPLE, short 2 19 11022 BALL VALVE, vented 1 20 108865 SCREW, mach, pan head 1 21 100721 PLUG, pipe, headless 1 22 169971 FITTING, air line 1 2 155541 UNION, swivel; 90_ 1 24 20266 HOSE, coupled 2 25 20856 COUPLER, air line 1 27 1107 ELBOW, 45_, 1/4 npt 1 50 158212 BUSHING, pipe 1 51 28740 HOSE, coupled, conductive 1 52 27607 FLOW GUN, severe duty 1 5 16868 BUSHING, nozzle 1 54 161505 NOZZLE, flow gun 1 08666 5

Installation Mounting the Elevator Base to the Floor You must mount the elevator base to the floor before you operate this equipment. 1. Position the elevator where there is at least 9 feet (2.75 meters) of overhead clearance. 2. Mark and drill holes in the floor for 0.5-in. (1 mm) mounting bolts. See the mounting layout in the imensional rawing on page 7.. Level the elevator base, using shims if necessary, and bolt the base firmly to the floor. Grounding Proper grounding is an essential part of maintaining a safe system. To reduce the risk of static sparking, the mounting cover and all electrically conductive objects or devices in the dispensing area must be properly grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment. To ground the dispenser, connect the end of the ground wire to a true earth ground. Operation MOVING PARTS HAZAR To reduce the risk of serious injury, including cuts, amputation of fingers by the agitator blades, and splashing in the eyes or on the skin, always shut off the agitator (disconnect the air line from the agitator) before you raise, check, or repair the agitator. Never operate the agitator when the elevator is raised. See Moving Parts Hazard on page. Startup See the Parts rawing on page 4. 1. Flush the dispenser before first use. NOTE: The pump was tested in water. To eliminate possible contamination of the fluid you are pumping, before you use the dispenser, flush the pump thoroughly with a solvent compatible to the solvent you are dispensing. 2. Ensure that the needle valve on the agitator is closed and that the dispenser ball valve (19) is closed.. Connect the air supply line to the male air line fitting (22). 4. Using the needle valve on the agitator to adjust the agitator speed, gradually increase the speed until you can see (through the inspection port in the drum cover) movement in the surface of the liquid, but do not increase the agitator speed enough to create a vortex in the surface of the liquid. If the surface begins to vortex, decrease the agitator speed to prevent air entrainment. NOTE: Always maintain moderate agitator speed, which is approximately 50 rpm of the agitator blades. Excessive agitator speed may cause vibration, foaming of fluid, and increased wear on parts. Always agitate fluid thoroughly before supplying it to the dispensing equipment, and continue agitating fluid while the dispensing equipment is being supplied. 5. Use the regulator (10) and ball valve (19) to control the pressure and operation of the pump (1). 6. Raise or lower the elevator by pulling out or pushing in the air control valve (a push-pull handle) on the rim of the drum cover. Normal operation requires only a few seconds for air pressure to build up and raise the elevator or to exhaust and lower the elevator. NOTE: To increase the operating speed of the elevator, loosen the hex nut on the restrictor valve, and turn the valve needle out. To decrease the operating speed, turn the valve needle in. The restrictor valve is on the top of the elevator, as shown in the Parts rawing. 6 08666

Service and Technical ata See the individual component instruction manuals for service instructions and technical data. imensional rawing NOTE: See individual component instruction manuals for dimensions of agitator, pump, elevator, siphon kit, and drum cover. height of unit from base to top of pump when elevator is raised Elevator Base Mounting Hole Layout 95 in. (241 mm) 8.88 in. (225.6 mm) 5.5 in. (140 mm) 0.56-in. (14.2 mm) holes 25.9 57 in. (1448 mm) 9294A 5.62.75 ti22759a 08666 7

The Graco Warranty and isclaimers WARRANTY Graco warrants all equipment manufactured by it and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. As purchaser s sole remedy for breach of this warranty, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment proven defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco s written recommendations. This warranty does not cover, and Graco shall not be liable for, any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non- Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility with Graco equipment of structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claim. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor and transportation. ISCLAIMERS AN LIMITATIONS The terms of this warranty constitute purchaser s sole and exclusive remedy and are in lieu of any other warranties (express or implied), including warranty of merchantability or warranty of fitness for a particular purpose, and of any non-contractual liabilities, including product liabilities, based on negligence or strict liability. Every form of liability for direct, special or consequential damages or loss is expressly excluded and denied. In no case shall Graco s liability exceed the amount of the purchase price. Any action for breach of warranty must be brought within two (2) years of the date of sale. EQUIPMENT NOT COVERE BY GRACO WARRANTY Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose, with respect to accessories, equipment, materials, or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motor, switches, hose, etc.) are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. Graco Phone Number For the latest information about Graco products, visit www.graco.com. For patent information, see www.graco. com/patents. TO PLACE AN ORER, contact your Graco distributor, or call to identify the distributor closest to you: Phone: 612626921 or Toll Free: 1--800--28--0211 Fax: 612--78--505 All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. Original instructions. This manual contains English. MM 08666. Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. AN SUBSIIARIES P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 USA ECOPYRIGHT 1996, GRACO INC. All Graco manufacturing locations are registered to ISO 9001. www.graco.com Revision C, January 2014 8 08666