Operator: Save these instructions for future use!



Similar documents
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Your safety and the safety of others are very important.

OBSOLETE. VS8510,VS8520 Millivolt Gas Valve

OBSOLETE. VS8420 Millivolt Gas Valve

G670 Intermittent Pilot Ignition Controls

37E73A-903 & 906 INTELLI-VENT

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

WHITE-RODGERS COMFORT-SET 90 SERIES

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

Your safety and the safety of others are very important.

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

SV9501/SV9502/SV9601/SV9602 SmartValve TM System Control

INSTALLATION INSTRUCTIONS

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

! WARNING. Before using product, read and understand instructions.

LPM-06 CONVERSION KIT

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Model Description / Applications. Intermittent Pilot Gas Ignition Control

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

CARING FOR YOUR WATER HEATER

INSTALLATION MANUAL GAS COOKTOP. Please read this guide thoroughly before installation. P/No.: MFL

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

NITROUS TRANSFER PUMP INSTRUCTIONS

Installation Instructions for Alarm Module Kit A043F059

UV100A Ultraviolet Air Treatment System

SL280UHV SERIES GAS FURNACE WARNING

Instantaneous gas water heater

INSTANT HOT WATER RECIRCULATING SYSTEM

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Operator: Save these instructions for future use!

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Norcold Repair Guide Models 442, 443, 452, 453, 462, 463, 482, 483

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

LED Security Spotlight User Manual

Gas Oven Repair Guide

Utility Distribution Systems

WARNING CAUTION 21V51U-843 DESCRIPTION PRECAUTIONS

National- Spencer Inc.

PREPIPED LIQUID FUEL MANIFOLDS PLPM

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

PARTS NEEDED FOR CONVERTING FROM LP TO NG

San josé OWNER S MANUAL

Time Propane Pressure Drop Test Sign-Off Sheet

OPERATING, INSTALLATION AND SERVICE MANUAL STORAGE TYPE GAS WATER HEATER /94

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

T360 Barbecue. Assembly Manual (G30531) Propane 1 YEAR LIMITED WARRANTY

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Tankless Water Heater

3 IN 1 BATHROOM HEATER

SERVICE MANUAL. Flammable Vapor Ignition Resistant Water Heaters. Gas Water Heaters. Troubleshooting Guide and Instructions for Service

PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER.

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Firewall. Propane flame projector Safety instructions and operating manual

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Troubleshoot resources for homeowner

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series:

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Oil and Coolant Circulating Heating System. Model - OCSM

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

COMMERCIAL ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Water Heaters. Residential 30, 40 and 50 Gallon

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

TWO BURNER PROPANE CAMPING STOVE

DC400 Dispensing Cutoff System


30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Universal Installation and Maintenance Instructions 71CD-1212 Spill Containment Bucket

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

GAS SAFETY PRECAUTIONS

orlando OWNER S MANUAL

INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE

Power supply unit Model: PAC-SC50KUA

INSTALLATION AND OPERATING INSTRUCTIONS

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

Transcription:

WHITE-RODGERS 36C01 Combination Gas Valves (24 Volt and 120 Volt Models) INSTALLATI INSTRUCTIS FAILURE TO READ AND FOLLOW ALL INSTRUCTIS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CTROL COULD CAUSE PERSAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTI This multi-function gas controls combines into a single compact package the functions of 3-position gas cock, a main gas valve and a pressure regulator. The pilot outlet is plugged, but will accept a 1 4 pilot line connection. This control can be mounted in any orientation except upside down. To permit replacement of a variety of valve sizes, this control is furnished with three reducer bushings (two 3 4 to 1 2 and one 1 2 to 3 8 ). Also included is a conversion kit which allows this valve to be used at regulator settings of 4.2 W.C. to 11.0 W.C. Model No. 36C01 36C01A Operator: Save these instructions for future use MODELS AVAILABLE Voltage 24 volts 120 volts Gas Nat. Nat. Current.23 Amp.035 Amp Electrical Rating: 24 VAC, 60 Hz., 23A Pilot Gas Outlet: Located at outlet end of the valve Type of Gas: Suitable for all domestic heating gases Pressure Regulator Setting: Adjustable from 2 1 2 to 5 W.C. (Factory adjusted for 3.5 W.C. Pressure Rating: 1 2 lb. per sq. in. Ambient Temperature: -40 to 175 F Mounting: Any position except upside-down 1 2 x 3 8 1 2 x 1 2 1 2 x 3 4 3 4 x 3 4 UPRIGHT CAPACITY (IN BTU PER HOUR) NATURAL GAS (1000 Btu/Cu. Ft. 0.64 Sp. Gr.) 100,000 230,000 230,000 280,000 LEFT OR RIGHT SPECIFICATIS LP GAS (2500 Btu/Cu. Ft. 1.53 Sp. Gr.) 162,000 372,600 372,600 453,600 Upright, 90 from upright or vertical INLET BOSS UP OR DOWN NOTE: Control shown may not be identical to replacement control. WHITE-RODGERS DIVISI EMERS ELECTRIC CO. 9797 REAVIS ROAD ST. LOUIS, MISSOURI 63123-5398 Printed in U.S.A. PART NO. 37-5870B Replaces 37-5870A 9947

PRECAUTIS DO NOT BEGIN INSTALLATI UNTIL YOU READ THE FOLLOWING PRECAUTIS. WARNING If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. 1. Failure to turn off electric or main gas supply to heating system could cause personal injury and/or property damage by shock, gas suffocation, fire, and/or explosion. 2. Do not use this control on circuits exceeding specified voltage. Higher voltage will damage the control and may cause shock or fire hazard. 3. NEVER USE FLAME OR ANY KIND OF SPARK TO CHECK FOR GAS LEAKS COULD CAUSE FIRE AND/OR EXPLOSI. 4. DO NOT USE WIRE JUMPER on pilot systems, such as standing pilot, proven pilot, or spark-to-pilot ignition a fire and/or explosion may result. 5. Do not use a control set for natural gas with LP gas, or a control set for LP gas with natural gas. Personal injury and/or property damage, gas suffocation, fire, and/or explosion may result. CAUTI 1. Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring can cause equipment damage, property damage, and/or personal injury. 2. This control is not intended for use in locations where it may come in direct contact with water. Suitable protection must be provided to shield the control from exposure to water (dripping, spraying, rain, etc.). 2

MAIN PIPING CNECTIS NOTE Horizontal Drop INSTALLATI All piping must comply with local codes, ordinances, and/or national fuel gas codes. 1. Turn off electrical power to the system at the fuse box or circuit breaker. Also turn off the main gas supply. 2. If replacing an existing valve, disconnect all plumbing and electrical connections from the old control. 3. The control may be installed in any orientation except upside down. The arrow on the valve indicates the direction of gas flow through the control. 4. You should use new pipe that is properly chamfered, reamed, and free of burrs and chips. If you are using old pipe, be sure it is clean and free of rust, scale, burrs, chips, and old pipe joint compound. 5. Apply pipe joint compound (pipe dope) or teflon tape that is approved for all gases, only to the male threads of the pipe joints. DO NOT apply compound or teflon tape to the first two threads (see fig. 1 for typical piping connections). 6. If you are using a vise or open-end wrench to hold the valve while installing piping, do not tighten excessively, as this may damage the valve. 7. If additional clearance for the gas cock knob is required when installing the new valve in an existing system, rotate the knob to the position between and. Depress the knob while turning the valve. The knob will depress only while in this position. 8. See SYSTEM WIRING when making electrical connections. After all gas and electrical connections are completed, turn gas on and check for gas leaks with leak detection solution or soap suds. Bubbles forming indicate a leak. SHUT GAS AND FIX ALL LEAKS IMMEDIATELY. GAS CNECTI Install fitting into pilot gas outlet (see fig. 2), turning until finger-tight. Insert clean, deburred tubing all the way through the fitting. While holding the tubing securely, slowly tighten fitting until you feel a slight give. Tighten the fitting an additional 1 1 2 turns. NOTE: Always Include A Drip Leg In Piping Horizontal 3 in. minimum Drop Pilot gas outlet Gas outlet Gas Valve Piped Gas Supply Riser 3 in. minimum Tubing Gas Supply Piped Gas Supply Gas Valve Figure 1. Typical gas valve piping Figure 2. Gas valve side view Gas Valve Riser 3 in. minimum PRESS TAP 3

INSTALLATI (cont d) SYSTEM WIRING CAUTI To prevent electrical shock and/or equipment damage, disconnect electrical power to system at main fuse or circuit breaker box until installation is complete. NOTE All wiring should be installed in accordance with local and national electrical codes and ordinances. Always check that the electrical power supply used agrees with the voltage and frequency shown on the gas control. The typical wiring diagrams (figs. 3 & 4) show only the terminal identification and/or wiring hook up. Always refer to wiring instructions provided by Equipment Manufacturer for system hookup operation. GAS ADJUSTMENT If the pilot flame is low and does not engulf the bulb of the mercury flame sensor, the system will not energize the main valve. If pilot gas pressure is too high, gas will sputter past the ignition electrode, and may not ignite. High pilot gas pressure may also cause the flame to lift off the burner, causing the flame sensor bulb to sense low heat. To adjust the pilot gas pressure, remove the cover screw (see fig. 5). To REDUCE pilot pressure, turn the pilot adjust screw (beneath the cover screw) clockwise. To INCREASE pilot pressure, turn the pilot adjust screw counterclockwise. Replace and tighten cover screw. PRESSURE REGULATOR ADJUSTMENT The pressure regulator has been factory adjusted (see control for specific setting). Although additional adjustments will not normally be necessary, you may adjust the regulator. Do not force the adjusting screw beyond the limits that it can easily be adjusted. 1. Energize valve to ignite main burner. 2. Remove Reg. Adj. cover screw (see fig. 6). 3. To DECREASE outlet pressure, turn the adjusting screw (beneath the cover screw) counterclockwise. To INCREASE outlet pressure, turn the adjusting screw clockwise. 4. Replace the cover screw. Cycle the valve two or three times to verify regulator setting. NOTE If adjustment to higher range (4.2 W.C. to 11.0 W.C.) is required, use conversion kit packed with control. Thermostat TH TH-TR TR Gas valve terminal panel Figure 3. Wiring for 36C01 (24 Volt) Gas valve 24 VAC Transformer Line voltage operating control High limit High limit Figure 4. Wiring for 36C01A (120 Volt) Pilot adjust cover screw Gasket Pilot adjust screw Figure 5. Pilot gas adjustment Regulator adjusting cover screw Figure 6. Pressure regulator adjustment Pilot adjust cover screw HOT Line LINE 4

LIGHTING INSTRUCTIS AND PRECAUTIS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot that must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. FOR YOUR SAFETY "WHAT TO DO IF YOU SMELL GAS" Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire of explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water. 1. STOP Read the precautionary information above. 2. Set the thermostat to lowest setting. 3. Turn off all electrical power to the appliance. 4. Depress gas control knob slightly and turn clockwise to (see fig. 6). If knob is in, turn clockwise to, then depress knob slightly and turn clockwise to. 36C Series NOTE: Knob cannot be turned from to unless knob is depressed slightly. Do not use tools or excessive force. 5. Wait fifteen (15) minutes to clear out any gas. If you then smell gas, STOP Follow B in the precautionary information above. If you don't smell gas, go to next step. 6. Remove the pilot access panel(s) located under the gas control unit. LIGHTING INSTRUCTIS Gas control knob 7. Find pilot - follow small metal tubes from gas control. BURNER THERMO- COUPLE 8. Turn knob on gas control counterclockwise to. 9. Depress control knob all the way and hold in. Immediately light the pilot with a match. Continue to hold the control knob down for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 4, 5, 8, and 9. If knob does not pop up when released, turn clockwise to, stop and immediately call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn the gas control knob to and call your service technician or gas supplier. 10. Replace pilot access panel(s). 11. Turn gas control knob counterclockwise to. 12. Turn on all electrical power to the appliance. 13. Set thermostat to desired setting. 1. Set the thermostat to lowest setting. 2. Turn off all electrical power to the appliance if service is to be performed. TO TURN GAS TO APPLIANCE 3. Turn gas control knob clockwise to. 4. Depress gas control knob slightly and turn clockwise to. Do not use tools or excessive force. Indicator 5 Gas cock knob Figure 7. Gas cock knob

If you need further information about this product, please write to White-Rodgers Division, Emerson Electric Co. 9797 Reavis Road St. Louis, MO 63123-5398 Attention: Technical Service Department