NEW. CIRRUS HD-OCT 5000/500 Advancing Smart OCT. Imaging Applications: Anterior Segment Glaucoma Retina. International Version



Similar documents
SOCT Copernicus HR Specification

Comparison to other anterior segment imaging devices

Cataract Testing. What a Patient undergoes prior to surgery

The Nurse/Technician Role Within the Emerging Ophthalmic Technology - OCTs/B-Scan

Cirrus HD-OCT Certainty in seconds. Certainty for years.

EFFECT OF MYOPIC LASIK ON RETINAL NERVE FIBER LAYER THICKNESS- IS IT SAFE OR UNSAFE?

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

Trends in Ophthalmology a Market Perspective. Matthias Karl, Michael Kempe

FIRST EXPERIENCE WITH THE ZEISS FEMTOSECOND SYSTEM IN CONJUNC- TION WITH THE MEL 80 IN THE US

ReLEx smile Minimally invasive vision correction Information for patients

THE EYES IN MARFAN SYNDROME

iocutouchtm for ipad Contents of Videos and Still Images Anatomy 906. Normal Eye and Orbit - no labels 907. Normal Eye and Orbit - with labels

Do You STILL Need Technology? DO YOU STILL TECHNOLOGY? The Challenges in The Challenges in FEC s Production Reports 2012

Spectral domain OCT used to view and quantify choroidal vascular congestion in new subretinal fluid following scleral buckling.

Optic Nerve Imaging. Management of Glaucoma

Three pearls in one shell. Heidelberg Retina Tomograph

MASTER OCT LECTURE OUTLINE Ophthalmic Photographers Society November 16, 2013 New Orleans, LA

NEW HORIZONS IN CORNEAL SURGERY VERSATILE FEMTOSECOND LASER WORKSTATION WE FOCUS ON PERFECTION

ALL-IN-ONE Optical Biometry, Dual Scheimpflug Tomography and Placido Topography

Patient views on ReLEx smile Excellent results clearly confirmed by survey

Ophthalmic Consultants of Long Island

Curtin G. Kelley, M.D. Director of Vision Correction Surgery Arena Eye Surgeons Associate Clinical Professor of Ophthalmology The Ohio State

LASIK. Complications. Customized Ablations. Photorefractive Keratectomy. Femtosecond Keratome for LASIK. Cornea Resculpted

What role does the nucleolus have in cell functioning? Glial cells

OCULUS PENTACAM BASIC CLASSIC HR

EyeMag Medical Loupes from ZEISS Seeing is believing NEW! LED illumination

Boomers and Disease Detection with OCT: Catalyst for Optometric Practice Growth

Essential Line from ZEISS Simplicity in basic diagnostics NEW

IOLMaster 500. Excellence in Biometry. Precision. Simplicity. Outcomes.

Rediscover quality of life thanks to vision correction with technology from Carl Zeiss. Patient Information

OCULUS Pentacam Pentacam HR

When a Macular Hole Is Not A Macular Hole. Contents. OCT Anatomy. Vitreomacular Traction 3/1/2012

Minimally Invasive Surgery: Femtosecond Lasers and Other Innovative Microsurgical Techniques

BSM Connection elearning Course

Ectasia after laser in-situ keratomileusis (LASIK)

Refractive Errors & Correction

femtosecond laser platform Exceptional versatility without compromise

SCHWIND CAM Perfect Planning wide range of applications

Applications in Dermatology, Dentistry and LASIK Eye Surgery using LASERs

Cataract l Glaucoma l Retina l Refractive. VISULAS YAG III. The Fastest YAG Laser. Laser Precision Par Excellence.

Cataract Surgery after Myopic Refractive Procedures. Ray Guard Eye Center Huang Wei-Jen, MD

The Eye: Anatomy, Histology & Histopathology. Gillian Shaw, DVM, MS September 9, 2011 gilliancshaw@gmail.com

Curriculum for the Glaucoma EBO-EGS Subspecialty exam/diploma (Glaucoma-medical)

Insert to. January Comfort and confidence for all IOL calculations

Refractive Surgery. Evolution of Refractive Error Correction

Make a difference in someone s life FITTING GUIDE

Looking for Keratoconus

Educational Goals & Objectives for Ophthalmology Residents at Parkland Memorial Hospital (PMH)

CustomVue Treatments for Monovision in Presbyopic Patients with Low to Moderate Myopia and Myopic Astigmatism

Preliminary U.S. FDA Outcomes of SMILE

Measure of Confidence. Glaucoma Module Premium Edition

ABrand New Refraction Meas urement Instrument

Descemet s Stripping Automated Endothelial Keratoplasty (DSAEK)

Providing Optimal Optics For Your Astigmatic Cataract Patients. While the cornea remains relatively stable and prolate throughout life

Welcome to the Verisyse Seminar

BIOL 1108 Vertebrate Anatomy Lab

Taking Your Fundus Exam to the Next Level

Help maintain homeostasis by capturing stimuli from the external environment and relaying them to the brain for processing.

IMAGE ASSISTANT: OPHTHALMOLOGY

The «three-in-one» Microkeratome for traditional LASIK, EPI-LASIK, and anterior and posterior Lamellar Keratoplasty

Explanation of the Procedure

HEALTHY EYES. Type 2 diabetes. Information for patients. Disease Management Programme

Aparna Karnik, O.D. 49 Springbrook Lane Newark, DE (302) (Home) (516) (Cell)

Femto-LASIK. Pulsewidth: Ultrashort-pulse micro- machining can make sub- wavelength holes. micromachining

A new level of insight and accuracy

SARAH PHYLLIPS. Now, a cataract procedure as unique as your eye itself. TABLE 1. Age: Depth (ACD) Axial LengTH

Incomplete LASIK Flap: (Continued) Boston K Pro Melt: Adam Prickett, MD (Resident)

Graduate Diploma in Optometry. Related modules Pre-requisites Satisfying requirements of second year BSc (Hons) Optometry examination board

MAke A difference in someone s life

RELEX SMILE AND SMILE EXTRA.. OUR 1 YEAR RESULTS AND PATIENTS SURVEY

Refractive Errors. Refractive Surgery. Eye Care In Modern Life. Structure of the Eye. Structure of the Eye. Structure of the Eye. Structure of the Eye

Femtosecond Lasers in LASIK Surgery

Residency Program in Ocular Disease and. Refractive and Ocular Surgery

CR-2 AF and CR-2 PLUS AF Non-Mydriatic cameras. Designed for the highest possible image quality. See the smallest details, don t miss pathology.

How To Know If You Can See Without Glasses Or Contact Lense After Lasik

Eye Care In Modern Life

Informed Consent for Refractive Lens Exchange (Clear Lens Replacement)

Comparison Combined LASIK Procedure for Ametropic Presbyopes and Planned Dual Interface for Post-LASIK Presbyopes Using Small Aperture Corneal Inlay

The cataract laser technology of tomorrow is here for you today.

DISTANCE LEARNING COURSE. Anatomy of the Patient Exam , BSM Consulting All rights reserved.

OCT-guided Femtosecond Laser for LASIK and Presbyopia Treatment

The light. Light (normally spreads out straight and into all directions. Refraction of light

MAZAHERI LASIK METHOD FOR VISUAL ENHANCEMENT TECHNICAL FIELD OF THE INVENTION. [0001] The present invention is directed, in general, to

<office> Welcome Package

CONSENT FOR CATARACT SURGERY REQUEST FOR SURGICAL OPERATION / PROCEDURE AND ANAESTHETIC

OCT-based IOL power calculation for eyes with previous myopic and hyperopic laser vision correction

Eye Associates Custom LASIK With IntraLASIK Correction Of Nearsightedness, Farsightedness, and Astigmatism Using IntraLase TM Technology

EPISCLERAL EYE PLAQUES FOR TREATMENT OF INTRA-OCULAR MALIGNANCIES AND BENIGN DISEASES

Tucson Eye Care, PC. Informed Consent for Cataract Surgery And/Or Implantation of an Intraocular Lens

Post LASIK Ectasia. Examination: Gina M. Rogers, MD and Kenneth M. Goins, MD

What are your options for correcting astigmatism?

The pinnacle of refractive performance.

Your one stop vision centre Our ophthalmic centre offers comprehensive eye management, which includes medical,

BACKGROUND INFORMATION AND INFORMED CONSENT FOR CATARACT SURGERY AND IMPLANTATION OF AN INTRAOCULAR LENS

Customized corneal ablation and super vision. Customized Corneal Ablation and Super Vision

Transcription:

NEW CIRRUS HD-OCT 5000/500 Advancing Smart OCT Imaging Applications: Anterior Segment Glaucoma Retina International Version

NEW PanoMap Analysis Wide-field structural damage assessment for glaucoma NEW PanoMap TM wide field analysis displays structural data for the entire posterior pole RNFL, ONH, and GCA metrics show the extent of structural damage At-a-glance insight A single analysis for integrated insights into early pathologies Backward-compatible PanoMap uses existing Macular Cube and Optic Disc Cube scans to provide a wide-field view of the posterior pole without altering scan protocols PanoMap Report with Combined GCA and RNFL Deviation Map

NEW Anterior Segment Premier Module from ZEISS The first retinal OCT with full anterior chamber imaging and measurements ChamberView ChamberView image* ChamberView provides an expansive 15.5 mm wide view of the entire anterior chamber with objective tools for measuring anterior segment ocular structures HD Cornea HD Cornea Scan 9 mm high-resolution scan, including versatile tools for measuring thickness of residual stromal bed, LASIK flap, and other corneal structures *Patent pending Pachymetry Map 9 mm pachymetry map highlights corneal irregularities and identifies thinnest point for refractive surgery screening NEW OCT Goniometry A non-contact method to help identify patients at risk of angle closure glaucoma Wide Angle to Angle Scan Wide Angle-to-Angle scan and HD Angle Scan Provide exquisite detail of the iridocorneal angle and include measurement tools for Angle Opening Distance (AOD500/750) and Trabecular Iris Space Area (TISA500/750) to quantify and track degree of angle closure IC Measurements: Value: AOD500 0.18 mm AOD750 0.22 mm TISA500 0.07 mm TISA750 0.11 mm SSA 19.69 HD Angle Scan with Measurement Table

NEW Smart HD Scan Patterns Targeted visualizations of critical anatomy Automatic centering of scans ensures you see the fovea in each patient. HD 21 Line HD 1 Line (100x averaged) HD Cross Details matter Add flexible HD scans to your macular scanning protocol for an efficient visual assessment of macular status Get it right the first time Improves clinic flow by helping to eliminate rescans due to missed fovea HD Radial New Smart HD 1 Line scan Captures and averages 100 b-scan images with automatic centering at the fovea or region of interest. The result is a brilliant image that simultaneously highlights detail in the vitreous, retina, and choroid.

NEW Layer by Layer En Face Views Reveal what lies beneath the surface En Face VRI View VRI en face preset display: Epiretinal membrane (ERM) example where the dark areas indicate membrane detachment En Face Mid-Retina View Mid-Retina en face preset display: Cystoid macular edema (CME) example with the hallmark flower petal pattern En Face IS/OS-Ellipsoid View IS/OS-Ellipsoid en face preset display: Hydroxychloroquine toxicity example with the classic bull s eye maculopathy En Face Choroid View Choroid en face preset display: Geographic Atrophy (GA) example where the bright regions highlight the RPE loss

Technical Data CIRRUS HD-OCT 5000/500 New Software Version 8.0* includes: En Face Analysis PanoMap Optional licensed features: Smart HD Scans HD 1 Line 100x HD 21 Line 1 Line (100x averaged) 21 Lines (4 or 8x averaged) HD Radial HD Cross Two interchangeable lenses expand CIRRUS HD-OCT with corneal, anterior chamber, and wide angle to angle imaging 12 Lines (8x averaged) 10 Lines - 5 horizontal, 5 vertical (8x averaged) Anterior Segment Premier Module with External Lens Kit Measurement Capabilities ChamberView 15.5 mm x 5.8 mm (max.) Anterior Chamber Depth, Angle to Angle Distance, Lens Vault, Chamber Area, Corneal Thickness, Angle and Caliper Tools Wide Angle to Angle 15.5 mm x 2.9 mm Angle Opening Distance (AOD500/750), Trabecular Iris Space Area (TISA 500/750), Scleral Spur Angle, Angle and Caliper Tools HD Cornea 9 mm x 2 mm Residual Stromal Thickness, Caliper Tool HD Angle 6 mm x 2.9 mm Angle Opening Distance (AOD500/750), Trabecular Iris Space Area (TISA 500/750), Scleral Spur Angle, Angle and Caliper Tools Pachymetry Map 9 mm diameter Sector Thickness Values, Minimum Thickness CIRRUS 5000 Hardware/Computer Updates Operating system/processor Windows 7, i7 processor (4th generation) Memory 16 GB Hard drive/internal storage 2 TB *Version 8.0 is compatible with CIRRUS Models HD-OCT 5000 and 500 only. Model 500 available with all listed features except Smart HD Scans. CIRRUS Review Software supported Operating Systems: Windows 8.1, Windows 7, Windows Server 2008 R2 EN_31_010_0014I CIRRUS, ChamberView PanoMap,SmartCube are either trademarks or registered trademarks of ZEISS in the USA and/or other countries 2015 Carl Zeiss Meditec, Inc. All rights reserved. The contents of this brochure may differ from the current status of approval of the product in your country. Please contact your local representative. 1014 5M Carl Zeiss Meditec, Inc. 5160 Hacienda Drive Dublin, CA 94568 USA www.meditec.zeiss.com/cirrus Carl Zeiss Meditec AG Goeschwitzer Str. 51-52 07745 Jena Germany www.meditec.zeiss.com/cirrus