Keggomax CM Reflux Still



Similar documents
EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.

INSTALLATION INSTRUCTIONS FOR VW MK5

Stainless Steel Single and Dual Circulation Kits

Awning Instructions. Standard Manual 1.5m to 4.5m

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

GEET Fuel Processor Plans

RECTIFIER DESIGN FOR FUEL ETHANOL PLANTS

Accessories for GF and RA machines

Modular Locomotive System Instruction Manual for HBK8 George Body Kit

Universal Adjustable Fuel Pressure Regulator

11. COOLING SYSTEM 11-0 COOLING SYSTEM BET & WIN 50

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Operators manual Basic water heater

Laddomat Charging unit

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

the stainless steel water-heater for your woodstove USER S MANUAL

Saferand easierinstallation

EZ-Steer Assisted Steering System

Watts Pure Water Systems

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

1 DESCRIPTION OF THE APPLIANCE

LYCOMING O-360. Engine Installation

HEAVY DUTY STORAGE GAS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Heater Replacement Procedure

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Volkswagen Golf > VW Rabbit GTI 2006->

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

DIRECT PRINTING NYLON JACKETS. The Basics

Description of functions

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

SCREEN PRINTING INSTRUCTIONS

M A N U A L

Installation Guide for the TJ LCG PRO Suspension System (Low Center of Gravity) Available 4 or 5

Cooking at the Speed of light!

ASME Packaged Indirect Fired Water Heater

Reverse Cycle Inverter Split System Air Conditioner

Unit 24: Applications of Pneumatics and Hydraulics

Cooling system components, removing and installing

Energy Saving Fact Sheet Boilers

Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Chemicals Needed:

Fuel. What you will learn. Things you need before you start. Materials. Tools. When you have finished this module, you should be able to:

MUELLER FALLING FILM CHILLERS


FOR ANY QUESTIONS, PLEASE CALL M-F 8:00a.m.-8:00p.m. EST. REAR BRAKES 1 AEROSPACE COMPONENTS

Air Conditioner Water Heater Model ACWH18

Select Radiators Installation Guide

8.9 - Flash Column Chromatography Guide

1-Stainless Steel conical fermenter with a thermometer setup.

Melting Point, Boiling Point, and Index of Refraction

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

Installation Guide 2010 BMW S1000RR Full Exhaust System

R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

GLASTAR SERVICE BULLETIN 36, SUPPLEMENT A

INSTALLATION INSTRUCTIONS MK-8704

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

KITCHEN INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Hydraulic control unit series

Installation Instructions

Stainless Steel Tank and Container Catalogue

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

How does solar air conditioning work?

Line to Refrigerator Ice/Water Dispenser

Odyssey of the Mind Technology Fair. Simple Electronics

SunMor SM-V30 Solar Water Heater Installation Manual

Modular Locomotive System Instruction Manual for HBK5 Billy Body Kit

Things you need to assemble the tube actuator. Left to right. are small piece of masking tape, super glue,pen knife and small

1. Lay out 2 pieces of 7/8" tubing and mark for bending as shown. Remember that the bend is in the shaded area as shown below in Figure 1.

DIGITAL WARMING CABINETS

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

James M. Pleasants Company

AIR OPERATED OIL PUMPS AND KITS

This kit may void factory warranty please check with manufacturer.

Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.

Wren Kitchens Installation Tips Carefully check your kitchen delivery Measuring out and marking up Fitting the base cabinets...

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Quick guide: using CTE security straws for cryopreservation of pronuclear stages, embryos and sperm

Free piston Stirling engine for rural development

INSTALLATION MANUAL. Installation Instructions

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

6 LED colours: White Blue Green Red Yellow Amber

Pole Lathe and Shave Horse Design

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

INFRARED QUARTZ WALL HEATER

Cooling system components, removing and installing

Instruction Manual. AWK-115S

CHEMICAL CLEANING UNIT Product number:

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

The ACCU-LUBE Micro-Lubricating System for external and internal lubrication

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

INSTALLATION INSTRUCTIONS BL-8704

Transcription:

Keggomax CM Reflux Still The Kegomax CM Reflux Still is easily one of the best reflux stills available today. It s a professional grade still that produces exceptional purity spirit with a high level of purity (approx 95% ethanol) and is well suited to large batch sizes. As any experience distiller will know, the purity of the spirit produced is largely depended on the height and volume of the reflux column. Our reflux column boasts a height of 77cm and diameter of 50mm meaning that this is also one of the largest domestic stills available. The Keggomax CM Reflux Still can be used with a 50L commercial keg as shown in photo (left) or there is also optional hardware to attach it to other larger or smaller boilers using a nut arrangement. The Keggomax CM Reflux Still features: Copper catalytic converter to release sulphurous odors from your spirit Huge 77cm tall reflux column Pre-cooler jacket on reflux column Full stainless steel body Food grade silicone seals Optional mounting hardware for easily mounting to readily available kegs Superior design and performance Keggomax CM Reflux Still Includes 1. Reflux column and condenser 2. Silicone bung 3. Copper catalytic converter (already packed into the column) 4. Stainless steel packing (already packed into the column) 5. Thermometer

95% Alcohol Concentration A mixture of ethanol and water at a concentration of 96.4% is known as an azeotrope. An azeotrope is a mixture whereas the ratio cannot be changed by simple distillation. So in other words theoretical maximum purity of a distilled spirit using conventional means is 96.4% and the closer you can get to that point the better you still is. Under conventional conditions you will not be able to get above this point. The Keggomax CM Relux Still is capable of producing up to 95% pure ethanol meaning it s fairly close to being the perfect piece of distilling equipment for very high grade pure alcohol. The purity of your alcohol is extremely important as it is the difference between good and bad spirit and it will save you a lot of time in the long run as it means you will not need to double or triple distil your spirit to get good results. In addition to this, the higher the percentage of alcohol you can get the more good spirit you can extract from the wash. 50L Batch Size When used with a 50L boiler the Keggomax CM Reflux Still has a large output capacity which will enable you to make approx 20 bottles of spirit (40% alcohol x 750ml) from one 50L wash. During the distilling process it is always a good idea to throw away the first part of the collected distillate (AKA the head ) and the last part (AKA the tails ). As you do larger batch sizes the amount of head and tails that you throw away doesn t increase proportionally. So in other words you will be able to extract more good spirit from one large 50L batch than 2 smaller 25L batches. So a large still like this not only allows you to process large amounts of spirit at once, but it also improves your overall efficiency in converting wash to spirit. Copper Catalytic Converter The Keggomax CM Reflux Still come with the reflux column already packed with stainless steel wool and the fine copper catalytic converter mesh. The copper catalytic converter mesh is placed inside the top of the column which helps to release sulphides. This is important as it will ensure you spirit has a pure taste and is without any off aromas. Water Speed Controlled Unlike other stills the Keggomax CM Reflux Still gives you full control of reflux process by adjusting the cooling water flow speed. A faster water speed will enable you to send more spirit back down the column and give you higher purity. A slower water speed will enable you to collect spirit faster but the spirit will be of a lower purity. We recommend a water speed of anywhere between 1-6L per minute depending on your desired results. Page 2 of 5

Cooling Tank The Keggomax CM Reflux Still can be used with a mains water supply running straight from your tap and through the still and down the drain. Some customers might see this to be a waste of water and will prefer to use the still with a recalculating pump and a tank of water. If you decide to do this we recommend your tank be at least 180 litres to effectively dissipate the heat. NOTE: A standard wheelie bin makes an excellent size water tank for this purpose. Rain water tanks are also an excellent idea if you have one at home. Unlike other stills the Keggomax Reflux Still has a condenser where the cooling water travels up the centre of the condenser as opposed to the outside. The reason for this is so the distillate travels down on the outside of the condenser which enables you the body of the condenser to dissipate approximately 15% of the heat into the air. This makes the cooling process more efficient and will ultimately reduce the amount of heat transmitted to the water and therefore reduce the size of the water tank you need. This is one of the reasons why the Keggomax CM Reflux Still is more efficient than other stills on the market that require larger cooling tanks and consume more water. Water Circulation It is important to have the Keggomax CM Reflux Still set up with the plumping correctly. As shown in the diagram to the right, the cooling water should enter the bottom of the condenser cooling down the spirit on the way. The water then passes out the top of the condenser then into the bottom inlet of the jacketed part of the reflux column. The water is then collected from the upper outlet of the jacketed part of the reflux column and either disposed of, or pumped back into a recirculation tank to continue the process. Page 3 of 5

Mounting Hardware The photo below shows the base of the Keggomax CM Reflux Still. Unlike other stills, the Keggomax CM Reflux Still has several different mounting options as shown below: Option 1 Threaded Reflux Column As shown in the photo below this is how the Keggomax CM Reflux Still comes without any mounting hardware. From this point the still can be screwed directly into a pot or into your boiler. Option 2 Tri-Clover Keg Adaptor This option comes with a food grade silicone seal, tri-clover fitting, and tri-clover clamp that simply screws onto the bottom of your Keggomax CM Reflux Still. Once you have done this you can simply use the tri-clover clamp to connect the still to your keg boiler. Option 3 Nut and Seal Assembly Just like option 2, this option comes with a food grade silicone seal. It also comes with two stainless steel nuts. Option 1 Threaded Reflux Column Option 2 Tri-Clover Keg Adaptor Option 3 Nut and Seal Assembly WARNING Some countries like NZ allow you to use a home distiller for personal use, others like Australia require you to have a licence. Even without a licence, you are allowed buy this still in Australia for the sole use of water or essential oils. It is up to you to look into your local laws before purchasing. We do not advocate breaking any laws. Page 4 of 5

Keg Boiler Stainless steel 50L kegs are perfect to be used as keg boilers. They are relatively inexpensive, strong, have thick walls, sturdy handles, made from high grade 316 or 304 stainless steel, and most of all, they are great for boiling your wash. If your kegs are full stainless you can put them directly onto a heat source(ie. Mongolian burner, or stove) or preferably you can fit with an electrical element and your Keggomax Reflux still can attach to the top of the keg simply using the tri-clover mounting hardware (as shown in photo above on the left). Weld Free Stainless Steel 2200 Watt Electrical Element As well as supplying the keg boilers made up, we can also supply our specially designed 2200watt electrical elements that can be easily ported into the side of any keg or pot. The total diameter of the electrical element is small enough so that you can fit it into the neck of a commercial type 50L keg. It s a simple 3 step process to make your keg boiler: 1. Remove spear from keg 2. Drill 32mm diameter hold near the bottom of the keg in the side wall. 3. Feed 2200 watt element into the top of the keg and using some coat hanger wire or similar, pull the element back through the hole that you just drilled and tighten the nut up from the outside of the keg. The whole process requires no welds and can easily be disassembled for cleaning or other sanitation. Once you have purchased or made your keg boiler, you can simply use the tri-clover mounting bracket to attach the Keggomax CM Reflux Still to it. Page 5 of 5