Please read operating instructions carefully before use and keep for further reference.



Similar documents
OPERATING INSTRUCTIONS

Bitumen welding from Leister. Fast and safe with the BITUMAT.

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1

SMD Rework Station TABLE OF CONTENTS

INFRARED QUARTZ WALL HEATER

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

CARING FOR YOUR WATER HEATER

2-SLICE COOL TOUCH TOASTER

DITZLER VULKAN DR-1000/DR Plastic welding equipment

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Electrical Resistance Resistance (R)

VACUUM CLEANER INSTRUCTION MANUAL

ELECTRIC INSTANTANEOUS WATER HEATER

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

TIG INVERTER INSTRUCTION MANUAL

USER S MANUAL HSC-24A

Electrical Safety Tips. Help us keep you safe

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

- 2 - IMPORTANT SAFETY REMINDERS

TS1200 Intelligent Lead Free Soldering Station. Operation Manual

8" BENCH GRINDER OWNER'S MANUAL

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

HOUSING QUALITY STANDARDS (HQS)

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

AIR-CONDITIONER SPLIT TYPE

Microwave Oven. Warning: a) This oven is not for commercial use. b) Don't open the cover of the machine except professional person.

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

B-AIR BLOWER CUB POWER MODEL # CP-1

Model 1756 Test Lead Kit

Machine needle shut-off nozzle type-a

LX650 Lamp/Filter Replacement Instruction Sheet

Use and Care Manual. Model CPA12KH AIR CONDITIONER

HYLA NST Cleaning System

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

MIST DECORATIVE LAMP WITH ESSENTIAL OIL DIFFUSER

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Operating instructions in the back. PD1020L

Super Cascade Filtration Systems (CE)

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

PORTABLE AIR CONDITIONER

Threaded Inline Air Heaters

PROFESSIONAL POPCORN MAKER

User s Manual Before using the inverter, you need to read and save the safety instructions.

Installation and safety instructions for AC/DC built-in devices

WSD130 SOLDERING STATION


HAIR CLIPPER. Model No. HC5150 HC

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX


TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

FUEL CELL CAR SCIENCE KIT ASSEMBLY GUIDE. Battery operation instructions:

aseries A13B Mini Bullet Camera User Manual

Electrical Grounding. Appendix C

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Peasouper Operator s Manual

ELECTRICAL SAFETY. The standard unit for measuring electrical current.

WARMER or COOKER/WARMER

Hot Water Urns. all models. Helpline. v3.0

Routine and Emergency Boiler Operation

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

CHARGING SYSTEMS INTERNATIONAL

IMPORTANT SAFETY RULES TO FOLLOW

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

D I G I T A L C L A M

AOYUE. INT 738H (Centigrade / Fahrenheit switchable) Multi-Function Re-Working System INSTRUCTION MANUAL. Replacement Air Nozzles

COLOR VIDEO DOOR PHONE CDV-71BE/D

Nokia Bluetooth Headset BH-104

Odyssey of the Mind Technology Fair. Simple Electronics

User Manual Color video door phone

Active Monitor Box McCrypt S.T.E.V.E. 15. Order No

2 YEAR WARRANTY S7200PAU USE & CARE MANUAL ADVANCED CERAMIC TECHNOLOGY. To register your product go to

, User s Manual

PA 03 basic device TECHNICAL DATA. English

2 electrical. electrical PulteGroup, Inc. All Rights Reserved.

ADM1TE 5/30A DIN rail single phase two wire energy meter

Wine Cooler with Thermo-Electric Cooling & Heating Technology

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

SVENSKA DANSK NORSK

Current Monitoring Kit

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

SunMaxx Solar Filling Station Operating Instructions

Operating Instructions Drill rig DRU160

User Manual THR840DUK Digital Thermostat

100 Series Maxi Internal Filters. Instruction Manual

Transcription:

GB OPERATING INSTRUCTIONS LEISTER Welding-Pen R Hot air tool Please read operating instructions carefully before use and keep for further reference. APPLICATION The LEISTER Welding-Pen R is a hot air tool that can be installed for continuous operation. It has an ergonomic shape and is light weight what makes it suitable as hand tool as well as for the installation into machines and vent constructions. The cooled heater tube as well as the LEISTER screw-on drawing nozzle with taking tip make the Welding Pen to a very efficient tool for plastic welding. Welding of thermoplastic materials and also single-ply flexible plastics in the form of boards, tubes, profiles, foams, tiles and sheets. The following procedures are possible: Rod and melt welding by means of LEISTER nozzles The hot air tool Welding PenR needs an external air-supply (LEISTER blower or compressed air). Digital display of SET and ACTUAL temperature values Temperature steplessly controlled Heating element protection Adaptor tube with heat protection LEISTER Process Technologies, Riedstrasse, CH-6060 Sarnen/Switzerland Tel. + 41 41 662 74 74 Fax + 41 41 662 74 16 www.leister.com sales@leister.com 1

WARNING Danger to life when opening the tool, as live components and connections ar exposed. Unplug the tool before opening it. Incorrect use of hot air blowers can cause fire and explosion hazard, especially near combustible materials and explosive gases. Do not touch the element housing and nozzle when they are hot as they can cause burns. Let the tool cool down. Do not point hot air flow in the direction of people or animals. CAUTION 120 230 FI The voltage rating stated on the tool must correspond to the line/mains voltage. For personal protection on building sites we strongly recommend the tool be connected to a GFCI (Ground Fault Circuit Interrupter) or a RCCB (Residual Current Circuit Breaker). The tool must be operated with supervision. Warmth can reach combustible materials, which are out of sight. Protect tool from damp and wet. TEST SIGNS This tool is CCA certificated (CENELEC Certification Agreement). TECHNICAL DATA Electrical safety: double insulated Voltage V~ 100 120 230 Frequency Hz 50/60 50/60 50/60 Capacity W 450 600 1000 Temperature C 20 600 20 600 20 600 Air flow l/min. >40 >40 >40 Air pressure Pa max. 10 5 (dynamic) Weight g 1000 with 3m cable, air hose and Y-connection Size mm ø 32/43 270 Mains voltage cannot be switched over -2-

USAGE Welding-Pen R Description of tool 10 3 4 5 11 1 2 7 5 4 9 6 8 1. Heat protection tube 2. Potentiometer for temperature adjustment 3. Handle 4. Hose clamp 5. Air hose 6. Y-connection 7. Hose connection for air-supply G1/4 8. Cable screw fitting for mains supply M16 1.5 9. Power-supply cord 10. Digital display of SET and ACTUAL temperature values 11. Screwed nozzle joint -3-

USAGE Welding-Pen R AIR SUPPLY Use an air filter, if air is dusty. Air flow can be adjusted by the LEISTER air flow adjuster. Compressed air When using compressed air, an oil and water filter must be connected. Air flow can be adjusted by air flow adjuster. OPERATION Operating conditions Fit appropriate nozzle as required. Connect air supply with corresponding hose connection (7). Adjust air flow by means of air flow adjuster or pressure reducing valve. ATTENTION: Keep minimum required air flow according to data on page 2. Connect tool to the mains. Adjust hot-air temperature by use of the red potentiometer. Internal electronic system controls the temperature according to the SET values. Display will blink until 20 C before reaching the SET value. Let the tool cool down after use! Change of nozzle Let the tool cool down before changing the nozzle. Do not touch hot nozzle and only lay it on heat resistant surface because of fire hazard. Nozzles can easily be screwed (M14) onto the heat protection tube. Use only LEISTER nozzles. -4-

USAGE Welding-Pen R Digital display (10) SET value ACTUAL value Error message L1 L99 Definition 5 C, 10 F Measurements in case of error message Turn potentiometer for temperature adjustment (2) to position 0, or disconnect tool from the mains for 5 seconds (automatic reset of electronic). Let the tool cool down. Check hose connection, air flow, air volume and power supply. Connect tool to the mains. Contact LEISTER Service Centre if malfunction does not disappear. ATTENTION! Do not operate tool without air supply! Function of heat protection Welding-Pen R Heating element switches off automatically if there is no air flow. If there is not sufficient air flow, power will be electronically reduced and the temperature keeps steady at about 600 C. If the air flow falls below a certain value, the heating switches off automatically. Accessories Only use LEISTER accessories LEISTER air flow adjuster PVC air hose Hose clamp for air hose Tubular nozzle ø 5 mm Draw nozzles with tacking tip for: rod ø 3 mm rod ø 4 mm profiled rod 90 5.7 mm Draw nozzles without tacking tip for: profiled rod 90 7 mm

BA Welding-Pen R/ 04.2002 TRAINING LEISTER Process Technologies and their authorised Service Centres offer free welding courses and training. (see page 1). MAINTENANCE Clean welding nozzles with a wire brush Check mains cable and plug SERVICE AND REPAIR Repairs have to be carried out by authorised LEISTER Service Centres only. They guarantee a specialized and reliable repair service within 24 hours using original LEISTER spare parts according to connection diagramms and spare parts lists. GUARANTEE AND LIABILITY Guarantee and liability are in accordance with the guarantee certificate as well as with the currently valid general business and sales conditions. LEISTER Process Technologies rejects any guarantee claims for tools which are not in their original condition. The tools must never be altered or changed. Technical data and specifications are subject to change without prior notice. Your authorized Service Centre is: LEISTER Process Technologies, Riedstrasse, CH-6060 Sarnen/Switzerland Tel. + 41 41 662 74 74 Fax + 41 41 662 74 16 www.leister.com sales@leister.com

LEISTER Process Technologies, Riedstrasse, CH-6060 Sarnen/Switzerland Tel. + 41 41 662 74 74 Fax + 41 41 662 74 16 www.leister.com sales@leister.com

LEISTER Process Technologies, Riedstrasse, CH-6060 Sarnen/Switzerland Tel. + 41 41 662 74 74 Fax + 41 41 662 74 16 www.leister.com sales@leister.com