Evacuation Lighting Management System



Similar documents
Emergency Lighting Introduction

User and Technical Guide. Nexus LX

Quick Design & Install Guide. Computerised Emergency Evacuation System LONWORKS TM Powerline Technology

Technical Description U00980 Revision 2

SAUTER novapro Open: B-AWS. BACnet Advanced Workstation

What You Will Learn About. Computers Are Your Future. Chapter 8. Networks: Communicating and Sharing Resources. Network Fundamentals

Operation and Installation Manual

PCS0100en Persy Control Services B.V. Netherlands

Guidance for Electrical Contractors on Emergency Lighting Legislation

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

PROFIBUS fault finding and health checking

OPTICAL FIBER repeaters/ isolators

PROFIBUS/PROFINET System design

Introduction to PROFIBUS and PROFINET

GadgetGatewayIa Configurable LON to IP Router and/or Remote Packet Monitor. ANSI (LonTalk ) and ANSI 852 (IP) standards based.

Square D Model 6 Motor Control Centers

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Kokii BatteryDAQ. BMS Software Manual. Battery Analyzer Battery DAS

A network is a group of devices (Nodes) connected by media links. A node can be a computer, printer or any other device capable of sending and

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Parking Guidance System

PLCs and SCADA Systems

Emergency Telephone Systems

Process Control and Automation using Modbus Protocol

DIGITAL CONTROL SYSTEM PRODUCT SOLUTIONS

Wireless LAN g USB Adapter

Lecture 4 Profibus. Urban Bilstrup Urban.Bilstrup@ide.hh.se

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Welcome to JT Fibre. All you need to know about your new next generation Broadband

IDDERO HOME SERVER. Quick start guide

Network Design. Yiannos Mylonas

LonManager PCC-10 and ISA Protocol Analyzers Models and

DCM. Product Brochure. Diagnostic Communication Master

No Wires. No Waiting. No Worries. NETWORKS WITHOUT WIRES Agoura Road, Suite 110 Calabasas, California 91302

PA MATTHEWS AUDIO NSW STATE HIGH SCHOOL PA SYSTEMS WHITE PAPER

Installation Manual Premier Elite ComIP

Datasheet n Wireless Router Models: AR, AR-HP. Fast 150 Mbps Wireless Speed. Long Range Up to 200+ Meters

Understanding Device Level Connection Topologies

802.11n Wireless Router. Datasheet. Models: AR, AR-HP. Fast Wireless Speed Up to 150 Mbps. Long Range Up to 200+ Meters

Planning BACnet networks

Advanced Central Monitoring. User Guide

Local Area Network. OSI Seven Layer Model. Whole Building Network

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

The intelligent DALI Emergency Lighting Monitoring System with One Click Commissioning

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

Routefinder Testing and reporting for emergency lighting systems

FALCO. Broadband Groomer. F-330 Series. Applications. Access system for:

Crow Limited Warranty. Print Version 017

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

Overview of Routing between Virtual LANs

Climate Ready Control Systems Technical Specifications

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

SNMP Web Management. User s Manual For SNMP Web Card/Box

Temperature & Humidity SMS Alert Controller

Repeaters and Mimics Data Sheet

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

Network Topologies. Network Topologies

Optical Network Management System. Remote Testing, Network Monitoring, and Service Provisioning Solution for High-Quality Network Performance

Remote Maintenance with Security Appliances FL MGuard RS2000 and RS4000. Economic and Reliable Service

M2M/IoT Solutions.

Welcome to life on. Get started with this easy Self-Installation Guide.

Technology Spotlight on Cellular Data Networking for SCADA system networks. Presented by Teamwork Solutions, Inc.

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

Using installed Fieldbus Wiring to carry Ethernet Communications

Networks. The two main network types are: Peer networks

White Paper. Technical Capabilities of the DF1 Half-Duplex Protocol

MechoNet TM Network Interface (MNI) Specification Submittal

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

OIL PRESS 71.8 PSI FUEL. Cloud based, diagnostic, engine monitoring and reporting system.

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

Easily connect your switchboards to facility management solutions

Highly Available Mobile Services Infrastructure Using Oracle Berkeley DB

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Computer Networks. By Hardeep Singh

SITRANS F M MAG 8000 Precise Metering with battery powered water meters. sitrans f

ADACSNET USB Control Module

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

MDI FAQ. Version 8.1.0a Page 1 of 16

Web site:

FiOS Self-Installation guide for VIDEO MEDIA SERVER EQUIPMENT

SL42-xx SL42: Smart lighting controllers installation in the pole

EMBEDDED ACCESS CONTROL Hardware Installation Guide

CONDIS. IT Service Management and CMDB

A Real Time, Object Oriented Fieldbus Management System

Energy Communication Unit (ECU)

Understanding Device Level Connection Topologies

Straton and Zenon for Advantech ADAM Copalp integrates the straton runtime into the ADAM-5550 device from Advantech

Model 2120 Single Port RS-232 Terminal Server Frequently Asked Questions

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Future Stars. Grade X Manual Chapter 1 Networking and Telecommunication. telecommunication. Telephones, telegrams, radios and televisions help

Product Information Sheet UH36 Hi Pot Tester

Chapter 9A. Network Definition. The Uses of a Network. Network Basics

Auditing the LAN with Network Discovery

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

PCS300 Universal IP Reporting Module V1.0

Introduction to Networking

Monitoring solar PV output

Transcription:

Evacuation Lighting Management System

ARE YOU PREPARED FOR AN EMERGENCY? In the interest of public safety, the Australian Standard AS/NZS 2293.2 outlines the obligations of building owners/ managers, in relation to Exit signs and Emergency Lighting, to ensure the safe evacuation of occupants in an emergency. It is the responsibility of a building owner/manager to: Check all emergency lighting units, and conduct a discharge test every 6 months Clean light emitting and reflecting surfaces of all fittings every 12 months Keep a log book of maintenance information Complying with these requirements can be very expensive and labour intensive, especially in larger buildings where testing requires many labour hours spent manually inspecting every emergency light. In addition, the disruption of the power supply during inspection can put public safety at risk. COMPONENT ICON COLOUR MEANING NO CHANGE STATUS OK RED BACKGROUND UNIT FAULTY RED DOT UNIT UNDER TEST SPU GREYED OUT LAMP GREYED OUT GENERIC DECOMMISSION SYMBOL UNIT NOT COMMUNICATING MAINS POWER LAMP OUT SPU DECOMMISSIONED ROUTER / REPEATER NO CHANGE GENERIC DECOMMISSION SYMBOL STATUS OK ROUTER DECOMMISIONED GROUP NO CHANGE RED TEST STATUS OK GROUP, OR UNIT IN GROUP, UNDER TEST

WHAT NEXUS LX CAN DO FOR YOU Nexus LX, is a real-time emergency lighting monitoring and control system which offers building owners/managers control over their public safety obligations, and helps manage installation and the maintenance of an emergency lighting system. A Nexus LX network enables the user to: Manage the installation and removal of components Cost effectively test and monitor the system Assign fittings to groups. Fittings are collected in groups so that they can be tested together in a logical manner eg. groups could represent different floors or departments Manage maintenance activities. Any fitting that fails a test or exhibits a fault will be automatically added to the Maintenance Group ensuring easy identification of the fittings requiring maintenance. The fittings are automatically removed from the Maintenance Group once they have been repaired and re-tested Ensure tests are performed properly Prepare reports. Testing and maintenance functions can be documented using the Nexus LX reporting functions. You can record all maintenance operations to satisfy requirements of AS/NZS 2293.2, and plan future maintenance budgets through the use of an online log book Log test results and print them as required. Nexus LX has been designed to enable maintenance personnel to easily maintain the emergency lighting system without having to walk through the building or disrupt the power supply. Nexus LX can test and report on the status of all emergency lights either individually, in groups or all together.

WHY CHOOSE NEXUS LX? There are many advantages of the Nexus LX system which can result in saving valuable time, money and resources. Labour Saving To ensure compliance with AS/NZS 2293.2, testing of a building requires many hours of labour for qualified staff to manually inspect and test every emergency light fitting and record the results in a log book. Manual testing is therefore very difficult and expensive to do on a large scale. Nexus LX enables the user to remotely activate light fittings and retrieve status information. The fittings will automatically send their status to the server in real-time ensuring the server always has an accurate record of the fittings status. This information is then automatically stored in an electronic log book. Maintenance personnel need only attend to fittings that require maintenance. Maximise System Availability Nexus LX can test and report on the status of an entire emergency lighting system within a building either individually, in groups or all together. By selectively alternating the grouping of the emergency light fittings, the installation can be tested in stages so that not all of the emergency lighting of the building is in recovery mode after a discharge test. Self Monitoring Nexus LX is self-monitoring and in the event of cable damage, can indicate the location of the fault down to the particular branch, which could potentially save hours of manual fault finding. Faults are detected in real-time and reported instantly so there is no need for users to initiate a search for potential faults. Extended Functionality (Optional) A General Purpose Node (GPN) provides a means to add a variety of monitoring control and alarm functions to a Nexus LX system. The ability to consolidate various management systems onto one network not only provides installation economies but can also provide new networked functionality opportunities. The GPN can be configured to perform a number of standard functions: Lamp and Area Light level monitoring/alarms Uninterruptible Power Supply (UPS) interface Building Management System (BMS) interface Mains monitoring External alarm interfacing. GPN s are installed anywhere on a Nexus LX network and managed with full onsite configuration facilities that come standard with Nexus LX. A combination of up to four modules can be installed into each GPN This will enable various different features to be installed at the same time. Modules: 4 Channel Analogue Input Module 4 Channel Optically Isolated Digital Input Module RS-485 Serial Data IO Module 4 Channel relay output Module.

Independent System The operation of emergency lighting is not impeded by, nor dependant upon Nexus LX, which is simply used to monitor and remotely test the light fittings without the need to visually and individually sight them for testing. A Nexus LX light fitting can be removed from or added anywhere within the Nexus LX network without interruption to the operation of the system. Data Integrity Data Integrity refers to the validity of data, which can be compromised by human error. Nexus LX can minimise these errors by automating processes and logging maintenance data. Nexus LX also enables easy, fast access to reliable data. Bus Topology Nexus fittings are connected by a twisted pair data cable in a doubly terminated multi-drop bus topology. The signal is absorbed by terminators to prevent the reflection of signals back and forth on the bus which can distort the signal. The data conductors are not polarised, thereby making connecting easy and reliable using a high quality pluggable connector. Twisted Pair Cable and Connector Bus Topology Nexus LX Single Point Units Ro Re PC NUN T Routers Repeaters Nexus LX Server Network Utility Node (NUN) Data Cable Terminators Data Cable

WHY CHOOSE NEXUS LX? Single Twisted Pair Cable The Nexus LX system requires a certain type of data cable to suit the data transmission characteristics of the network. Nexus LX uses a single shielded twisted pair cable as the network medium. The advantages of the data cable are: Through-Life Product Support Service Thomas & Betts provides a unique nation wide Through-Life Product Support Service to assist you at every stage of your System Life. Nexus specialists are available to offer assistance over the phone or within the field if required throughout the life of the system. High communication speed (78kbps) enabling fast system updates Highly resistant to external interference Ability to handle other LonWorks Systems on the same cable Very reliable Nexus LX Training Thomas & Betts offer training courses in the installation and commissioning of a Nexus LX system: Nexus Installation: Course for electrical contractors to educate them in the correct method for installing the Nexus LX System. Nexus Commissioning: Course covering the procedure for the commissioning of the Nexus LX System. Easy to use Graphic User Interface The Nexus LX software contains an easy to use Graphic User Interface which guides the user through a series of functions such as: Viewing fitting status Nexus LX Warranty All Nexus Light Fittings are covered by a 1 year return to base warranty that covers the Electronics, Cold Cathode Lamps and NiCad/NiMH batteries (external electronics, standard lamps, tombstones and mechanical damage excluded). Scheduling tests Viewing & printing test results Maintaining an electronic log Accessing diagnostic tools

HOW DOES NEXUS LX WORK? Computerised emergency lighting systems are a combination of a communication network and emergency lights distributed throughout a building. Nexus LX communicates between the emergency light fittings and a centrally located server, usually a computer. The network can pass messages both to and from the emergency fittings to either: instruct the fittings to perform a task - for example, turn on or off their emergency lamps, or report back to the server giving the fittings status for example, whether the lamp is working or not Computerised emergency lighting systems use a variety of means to communicate. The most common reliable method uses a dedicated communications cable wired between every emergency light fitting and the server. The method of communication within the network, called the protocol, determines the way the communication cabling must be installed, connected and used. Different brands of emergency lighting systems use different protocols and therefore cannot be combined. A Nexus LX Network consists of the following components: 1. Emergency light fittings connected together by a network of data cable and routers. 2. The Nexus server which performs network management and control functions and enables the user to perform the following tasks: Schedule Tests - making it easier to comply with the 6 month inspection requirement of AS/NZS 2293.2 Reporting - Test Schedule what is due to be tested and when Test Results discharge test results and most recent one-minute test Characteristics list of all installed SPU s (Single Point Units) Work Instruction every unit that failed the last test and main poll status Communication Errors Router Locations Maintain an electronic log book - providing a means of recording service history and can be used as a tool to plan maintenance requirements such as re-lamping or battery replacement. Also offers easier compliance with the requirements of AS/NZS 2293.2 Access diagnostic tools - Poll Status Test a scan of all fittings on the network allowing you to interpret which SPU s require attention Channel Communication Test to test the integrity of the Nexus LX network either by individual channel or by all routers.

Easy to Install A basic Nexus LX network is comprised of a trunk with one or more channels with level 4 shielded twisted pair data cable used as the transmission medium. Each channel is connected to the trunk by a router. The Nexus LX server and the network utility node are connected directly to the trunk. Repeaters can be used to extend both the trunk and channels as shown below. Where a channel has been extended using a repeater, the channel is hereby broken up into channel segments. Each channel segment consists of a length of data cable terminated at either end of the cable. Licensed electricians will find Nexus LX easy to install. Generally an installation requires: Floor plan drawings Project specifications The tenants fit-out guide and consultant specifications. Nexus LX specialists can be contacted at Thomas & Betts to assist with any installation queries. A Nexus LX trunk can also be integrated into existing trunk networks such as Ethernet and Optical Fibre. This can also provide an easy method of connecting to remote sites with an existing LAN or WAN network. Basic Nexus LX Network Fibre Optic Network ilon600 Ethernet Router Nexus LX Single Point Units T NUN CBL Fibre Optic Router Data Cable Terminators Data Cable Network Utility Node (NUN) Ro Re PC Routers Repeaters Nexus LX Server

Protocols Many Emergency Lighting systems currently on the market, cannot work with each other because they use a proprietory protocol developed by the systems manufacturer, making each system unique and exclusive. Systems using these proprietary protocols are considered closed systems. Open systems, on the other hand, use a protocol that is non-exclusive and available to everyone. These systems allow different manufacturers to share the data network because they each share the same protocol. LonWorks NEXUS LX uses an open, interoperable protocol known as LonWorks, developed by the Echelon Corporation and released in the early 1990 s. Today, LonWorks is one of the worlds most widely adopted standards for control of devices and systems in buildings. The language of the LonWorks network is called LonTalk and enables communication amongst the devices on a network. LonTalk can: provide end-to-end acknowledgement of messages authenticate messages prioritise delivery to provide bounded transaction times LonWorks allows network management tools to interact with devices over the network enabling: reconfiguration of network addresses and parameters downloading of application programs reporting on network problems Further information on LonWorks can be obtained from the Echelon Corporation website: start, stop and resetting of device application programs http://www.echelon.com Internet Protocol Network

NEXUS LX PRODUCT RANGE NEXUS SINGLE POINT UNITS Quickfit Quickfit Winner of Australian Manufacturing product of the Year, 2001, and Design Mark Australian Design Awards 2002 Emergency Exit with unique steel slide connect bracket allowing any Quickfit to be easily changed over or upgraded. The Quickfit range has a variety of units suitable for commercial and industrial applications including Weatherproof, Theatre Masks, Vandal Resistant and Cold Cathode with a 6 year rated lamp life. Spitfire Spitfire Legend Recessed Emergency Luminaire designed to be as unobtrusive as practically possible. The unit comes standard with a small 85mm lamp head and remote control gear. Engineered so the powerful halogen lamp provides significant levels of emergency light minimising the overall number of units required. All Spitfires include a Filament Continuity Circuit that monitors whether the lamp is present or if the filament has failed. Legend Premium Battens Architecturally pleasing exit that has a unique prismatic diffuser providing discreet yet highly visible exit directions at all times. Recessed, surface and wall mounted options available. Cold Cathode 6 year rated lamp life option also available. Premium Battens Emergency battens designed to offer superior photometric performance saving money as fewer battens need to be installed to achieve compliance with Australian Standards. Weatherproof and Vandal Resistant options available. Premium Flood Units Premium Flood Units Offers versatile powerful light that can be easily installed to provide emergency lighting for large open areas or for installations where ceiling mounted units are difficult to install or service. All premium flood units come with directional lamp heads in a range of 12W, 20W and 35W configurations.

POWER PACKS The Thomas & Betts range of Emergency Lighting Power Packs are suitable for retrofitting into T5, T8, PL and Circular lamped luminaries. Power Pack OTHER NEXUS LX COMPONENTS For full product details, please refer to the Thomas & Betts Lighting Catalogue Other components available to complete the Nexus LX system include: Router a device that connects a channel to the main trunk Repeater a device that connects two segments of a channel together to extend the channel length or increase the number of nodes connected to the channel LX Server Pack & Software - complete PC preloaded with Nexus LX Network Utility Node a device that is used in conjunction with the Network Utility Program to test the data communications of a Nexus LX network. Data Cable and Data Cable Terminators

www.tnbaust.com For further information, please refer to the Thomas & Betts Lighting Catalogue or contact the Thomas & Betts National Support Centre on Phone 1300 666 595 Fax 1300 666 594 Thomas & Betts Australasia Pty Ltd Head Offi ce & Manufacturing 23A Nyrang Street, Lidcombe, NSW 2141 ABN 62 074 810 898