Automated Breast Volume Scanning 3D Ultrasound of the Breast



Similar documents
A Guide to Breast Imaging: The Latest Technology for Screening and Detecting Breast Cancer

VI. FREQUENTLY ASKED QUESTIONS CONCERNING BREAST IMAGING AUDITS

Breast Density Legislation: Implications for primary care providers

Breast Sonography general goal. Optimizing Breast Sonography. BUS indications -- all. Breast Sonography specific goals.

Personalized Breast Screening Service

D. FREQUENTLY ASKED QUESTIONS

Shorter Scanning Times Through Efficient Software. Annette Tuffs. Article from the customer magazine Medical Solutions, December 2010

Provider Reimbursement for Women's Cancer Screening Program

Breast Imaging Made Brief and Simple. Jane Clayton MD Associate Professor Department of Radiology LSUHSC New Orleans, LA

Nicole Kounalakis, MD

OBJECTIVES By the end of this segment, the community participant will be able to:

Mammography AND CLINICAL BREAST EXAMS. joytolife.org WHAT YOU SHOULD KNOW ABOUT BREAST CANCER HOW TO DO A BREAST SELF-EXAM EARLY DETECTION SAVES LIVES

Illinois Insurance Facts Illinois Department of Insurance Coverage for the Diagnosis and Treatment of Breast Conditions

Rotation Specific Goals & Objectives: University Health Network-Princess Margaret Hospital/ Sunnybrook Breast/Melanoma

Official reprint from UpToDate UpToDate

How To Decide If You Should Get A Mammogram

Sustaining a High-Quality Breast MRI Practice

Breast Cancer. Presentation by Dr Mafunga

Voxar 3D TM. A suite of advanced visualization and analysis software tools

Q: What differentiates a diagnostic from a screening mammography procedure?

Introduction Breast cancer is cancer that starts in the cells of the breast. Breast cancer happens mainly in women. But men can get it too.

Low-dose CT Imaging. Edgar Fearnow, M.D. Section Chief, Computed Tomography, Lancaster General Hospital

U.S. Bureau of Labor Statistics. Radiology Tech

Mammography. What is Mammography?

patient guide BRCA1 and BRCA2 Genetic Testing for Hereditary Breast and Ovarian Cancer

Guideline for the Imaging of Patients Presenting with Breast Symptoms incorporating the guideline for the use of MRI in breast cancer

Mammography Education, Inc.

GE Healthcare. Vivid 7 Dimension Cardiovascular Ultrasound System

Breast Cancer: from bedside and grossing room to diagnoses and beyond. Adriana Corben, M.D.

GE Healthcare. Centricity* PACS and PACS-IW with Universal Viewer. Universal Viewer. Where it all comes together.

Examples of good screening tests include: mammography for breast cancer screening and Pap smears for cervical cancer screening.

GE Healthcare. Centricity * PACS with Universal Viewer. Universal Viewer. Where it all comes together.

Breast cancer close to the nipple: Does this carry a higher risk ofaxillary node metastasesupon diagnosis?

Ductal carcinoma in situ (DCIS)

for breast cancer detection

Mammograms & Breast Health. An Information Guide for Women U.S. DEPARTMENT OF HEALTH AND HUMAN SERVICES. Centers for Disease Control and Prevention

FRIEND TO FRIEND CPT CODES Diagnostic digital breast tomosynthesis, unilateral (list separately in addition to code for primary procedure)

BRCA Genes and Inherited Breast and Ovarian Cancer. Patient information leaflet

Recommendations for cross-sectional imaging in cancer management, Second edition

Coronis 5MP Mammo. The standard of care for digital mammography

Hologic Selenia Dimensions C-View Software Module. October 24, 2012

BRCA1 & BRCA2: Genetic testing for hereditary breast and ovarian cancer patient guide

Breast MRI Quality Control

Breast Cancer Survey. GfK HealthCare. A study conducted for Siemens Communication Sector, Erlangen. January 2011

How To Write A Draft Report On Breast Cancer Screening

In Practice Whole Body MR for Visualizing Metastatic Prostate Cancer

Medicare Part B. Mammograms - Updated Billing Guide for Screening and Diagnostic Tests

Digital Mammogram National Database

Infrared Thermography Not a Useful Breast Cancer Screening Tool

GE Healthcare. Centricity PACS and PACS-IW with Universal Viewer* Where it all comes together

NOTTINGHAM UNIVERSITY HOSPITAL NHS TRUST NOTTINGHAM BREAST INSTITUTE BREAST AND OVARIAN FAMILY HISTORY GUIDELINES

How To Compare Mammography To A 3D System

Evaluation and Management of the Breast Mass. Gary Dunnington,, M.D. Department of Surgery Internal Medicine Ambulatory Conference December 4, 2003

MAMMOGRAPHY GOALS AND OBJECTIVES

Breast Cancer Screening 101:

Saving healthcare costs by implementing new genetic risk tests for early detection of cancer and prevention of cardiovascular diseases

Global Business Unit Address. Siemens Medical Solutions USA, Inc N. Barrington Road Hoffman Estates, IL Telephone:

University Children s Hospital Basel

Hereditary Breast and Ovarian Cancer (HBOC)

Reduce Your Risk of Breast Cancer

Delivering Accelerated Results

Breast Cancer Screening

Local Coverage Determination (LCD): Screening and Diagnostic Mammography (L29328)

Breast Cancer. CSC Cancer Experience Registry Member, breast cancer

PART TWO: DIAGNOSING BREAST CANCER

Patient Prep Information

Breast Cancer Awareness Month

Breast Screening Explained. We can supply this information in other languages, in large print, on audio or in Braille.

MRI of the Breast. What is MRI of the Breast?

BREAST IMAGING. Developed by the Ad Hoc Committee on Resident and Fellow Education of the Society of Breast Imaging

Stereotactic Breast Biopsy

When it comes to treating breast cancer, doing less does more October is Breast Cancer Awareness Month

Men s Health: Testicular & Breast. September 2012

First floor, Main Hospital North Services provided 24/7 365 days per year

Clinical Trials and Screening: What You Need to Know

Breast Health Program

The File-Card-Browser View for Breast DCE-MRI Data

CRICO Breast Care Management Algorithm

Breast Ultrasound: Benign vs. Malignant Lesions

Michael A. Boss, M.D. FMH Plastic, Reconstructive und Aesthetic Surgery

An abdominal ultrasound produces a picture of the organs and other structures in the upper abdomen.

Office Visits. Breast

Cancer Care Delivered Locally by Physicians You Know and Trust

BREAST CANCER AWARENESS FOR WOMEN AND MEN by Samar Ali A. Kader. Two years ago, I was working as a bedside nurse. One of my colleagues felt

Office of Population Health Genomics

Breast cancer in the family

GE Healthcare. pet/ct for simulation. Precision in motion.

The Early Detection of Breast Cancer

Inova. Breast Care Institute

Transcription:

Automated Breast Volume Scanning 3D Ultrasound of the Breast Roel Mus, MD Radboud University Nijmegen Medical Centre (RUNMC), Nijmegen, The Netherlands Matthieu Rutten, MD, PhD Jeroen Bosch Ziekenhuis, s-hertogenbosch, The Netherlands

Automated Breast Volume Scanning 3D ultrasound of the breast Figure 1. The Siemens ACUSON S2000 Automated Breast Volume Scanner. Reducing subjectivity and operator-dependent bias from ultrasound, Automated Breast Volume Scanning (ABVS), or 3D ultrasound, opens the door to new applications in mammary diagnostics and beyond. With its recent acquisition of a Siemens ACUSON S2000 Automated Breast Volume Scanner (ABVS), the radiology department of the Jeroen Bosch Ziekenhuis (JBZ) in s-hertogenbosch, The Netherlands, is the first institution to use this new system in The Netherlands. A second system became operational at the St. Radboud University Nijmegen Medical Centre (RUNMC) two months later. First results are very promising, according to radiologists Matthieu Rutten (JBZ) and Roel Mus (RUNMC). Performing a hand held 2D ultrasound is inextricably dependent on the individual manipulating the transducer. During real-time image interpretation, tissue anomalies may occasionally be overlooked. The shortage of experienced sonographers and the time required for thorough examinations are obstacles that have thus far limited the application of hand held ultrasound in breast diagnostics, especially screening. 2D ultrasound is mostly used as an additional imaging modality following mammography. The arrival of automated 3D ultrasound has the potential to change that. Preprogrammed trajectories ensure that images of every part of the breast are generated by scanning the entire breast. The actual procedure is performed by a radiology technician or sonographer. The ensuing data are evaluated by a radiologist at a 3D workstation by analyzing the images of the breast in any desired direction. Presently a number of systems are available. An approach that reminds us of technology from the 1970s and 1980s is a system that requires patients in a prone position, breasts submerged in a tub filled with warm water. Other systems use a less known imaging approach, in

Figure 3. 3-in-1 hanging protocol of a 3D ultrasound examination of the breast. Above: transverse; bottom left: coronal; bottom right: sagittal. Figure 4. Automated Breast Volume Scan of a cyst location indicated inside marker, with distance to s Above: transverse; bottom left: coronal; bottom rig which patients in a supine position have their breasts scanned via a swiveling arm-mounted transducer that follows a number of pre-program med trajectories (AP, lateral and medial). In the latter category, the Siemens ACUSON S2000 ABVS (Figure 1) is the most advanced system currently available commercially. The system is equipped with a 5-14 MHz broadband transducer featuring Harmonic Imaging, and acquires 3D images of the breast in approximately 70 seconds. The entire examination of both breasts takes about 10 minutes. Figure 2. Scan configuration. Advantages of ABVS The ABVS technique reduces the subjectivity of ultrasound and makes it easier to verify results and compare them with mammographic and 3D-MRI findings, transforming ultrasound into a tool for double reading and improved diagnostic precision. An additional advantage of 3D ultrasound is the unique way in which the anatomy of the breast is rendered through a reconstruction of three orthogonal planes: transverse, sagittal and coronal (Figures 3 and 4). This third orientation allows slice-by-slice evaluation of the anatomy, from the skin down to the thoracic wall, a view currently not available using conventional 2D ultra sound. At the ABVS Workplace, the clinician can later adjust slice thicknesses down to a minimum of 0.5 mm. The coronal orientation turns out to be particularly well-suited for depicting anomalies in the make-up of glandular breast tissue. Small tumors with spiculae are best rendered in a coronal orientation (Figure 5). Lesion position is indicated on a coronally-oriented marker, and the distance to the skin and nipple is indicated in centimeters, which allows for easier and more insightful preoperative surgical planning. A major advantage is the optional storage of the full set of images which offers a reliable baseline for future comparison at the patient s next checkup. Additionally, batch evaluation of examination results by the radiologist can take place anytime, similar to the current post-processing of mammograms from the Bevolkingsonderzoek Borstkanker (breast cancer screening program) in the Netherlands. Learning curve As with all medical imaging, first-time users will have to be trained to use the technology, for example, how to maintain sufficient contact between the transducer and the breast during the examination. The pressure needed to maintain contact is generally well below the pain thresh - old, but can still be somewhat uncomfortable for the patient. The interpretation of the images is also subject to a learning curve (Skaane et al., ECR 2010). Reporting a 3D ultrasound examination can take from 5 to 35 minutes, dependent upon experience and case complexity. Cross-correlation between the multiplanar reconstructions helps to accelerate the evaluation process of the 2,000 to 2,500 images. This is an acquired skill, comparable to the

shown in 3 directions. Bottom right: lesion kin and nipple shown underneath. ht: sagittal. Figure 5. Post-lumpectomy exam of a specimen for verification. The coronal aspect (left) clearly shows the hypoechogenic tumor, bounded by spiculae. Above right: transverse; bottom right: sagittal. evaluation of the results of a 3D MRI breast examination. As the A-P diameter of the breast is much smaller than the L-R or cranio caudal diameter, the entire set of data can be worked through much more quickly with the coronal view. First experiences with the 3D ultrasound system show that evaluation of the generated images takes 2-4 minutes per breast, much faster than hand held ultrasound. Is ultrasound a useful addition to mammography screening? Interest in a combined mammography/ ultrasound screening protocol was raised by the results of the American College of Radiology Imaging Network (ACRIN) 6666 study (Berg et al., JAMA 2008), which showed that combined use of the two modalities allows more tumors to be traced in women with a high risk of breast cancer and a dense glandular breast tissue structure. The study not only showed that over half of the women aged under 50 have more than 50% glandular tissue (in women over 50 this number is 30%), but also that the sensitivity of mammography with these women levels out at 30-48%. Berg et al. (JAMA 2008) showed that the addition of ultrasound to mammography increased tumor detection sensitivity to 77.5%. Their proposal is to introduce ultrasound as a supplementary screening modality. A drawback of the revised examination protocol is the extra time required. The ACRIN report states that the average examination time for a bilateral ultrasound breast examination is 19 minutes, which does not include comparison with earlier examinations and reporting. At a rough estimate, 35% of the population of patients with more than 50% glandular tissue will need additional ultrasound examinations. This will mean a significant increase in workload and hence a lack of manpower. Automation of procedures, however, means that the actual examination can be performed by radiological technicians, and data acquisition and reporting can be performed separately, both in place and time. Partly as a result of the outcome of the ACRIN 6666 study in October 2009, the American State of Connecticut has passed a bill that grants women the right to be informed on the amount of glandular tissue in their breast and its implications for their screening. It is expected that this will strongly increase interest in breast ultrasound, with the rest of the world soon to follow this lead.

Roel Mus, radiologist UMC St Radboud Matthieu Rutten, radiologist JBZ Scientific research The St. Radboud University Nijmegen Medical Centre and the Jeroen Bosch Hospital are about to begin further clinical research using the ACUSON S2000 ABVS. Although the first results are promising, much research still needs to be done regarding the value of 3D ultrasound. Multiple studies have already been set up in Germany, the United States of America, Japan and the Netherlands (RUNMC and JBZ). These studies specifically address the sensitivity, specificity and positive predictive value of 3D ultrasound compared with 2D ultrasound and MRI. Improved specificity could help reduce the number of biopsies performed. However, the added value of 3D ultrasound seems to be lesion detection rather than lesion characterization. Automated volume ultrasound will probably make it easier to find smaller tumors (3-4 mm). The potential to review the 3D digital data sets of ultrasound images using a computer-aided detection (CAD) system should be expanded in the future. Women with an average breast cancer risk, i.e. a 10 to 20% lifetime risk of developing the disease, could probably gain the most from automated ultrasound screening for breast cancer. Presently in Europe and the United States, MRI is recommended as an additional screening modality for women with a high risk (20% or up) of breast cancer. Women with an intermediate breast cancer risk do not qualify for anything other than standard mammography, but they may also have a dense glandular breast tissue structure that negatively impacts the precision of mammographic examination. Women with more than 75% glandular breast tissue have a 4 to 5 times higher risk of breast cancer than women with little to no glandular tissue in their breasts. This results in a higher percentage of interval carcinomas and a poorer prognosis for any clinically diagnosed tumors. Especially for young women with a BRCA1 or BRCA2 gene mutation and dense breasts, additional examinations through ultrasound could well be much more reliable than conventional mammography, with the added advantage that no radiation is used. Presently this category of patients is screened according to a protocol involving a yearly mammogram and an MRI of the breasts. Using the ACUSON S2000 ABVS, the radiology departments of the Radboud University Nijmegen Medical Centre (Roel Mus, Henkjan Huisman, Nico Karssemeijer) and the Jeroen Bosch Hospital in s-hertogenbosch (Matthieu Rutten, Mathijn de Jong, Ivo Dubelaar, Thomas Fassaert) will this fall start a clinical study among women who carry a BRCA gene mutation. In this study the current protocol (combined yearly mammography + MRI) will be compared with an alternative protocol (biannual ABVS + yearly mammography + MRI). Also the results of automated breast volume ultrasound and mammography will be compared. We hypothesize that the use of automated breast volume scanning will detect more tumors than mammography, and that the incidence of interval carcinomas will decrease as the ABVS examination will take place every six months. In regular screening, the distinction between a cyst and a hypoechogenic fibroadenoma is of less importance (both being BI-RADS 2, i.e. benign). However, in examining BRCA gene carriers this distinction is very important as the growth rate of tumors in this group is much higher than in regular patients. The fast-growing tumor pushes the surrounding tissue away, leaving little time for spicula-like ingrowth. Hence, BRCA tumors are often characterized by an echographically clear, benign delineability. The entire study will take approximately two years. By that time we expect to have gathered sufficient data to assess the role of automated breast volume scanning in detecting breast cancer.

Local Contact Information 51 Valley Stream Parkway Malvern, PA 19355-1406 USA Phone: +1-888-826-9702 www.usa.siemens.com/healthcare Europe: + 49 9131 84-0 Asia Pacific: + 65 6490 6000 Global Business Unit ACUSON and S2000 are trademarks of Ultrasound 1230 Shorebird Way Mountain View, CA 94043 USA Phone: +1-888-826-9702 Global Siemens Headquarters Siemens AG Wittelsbacherplatz 2 80333 Munich Germany Global Siemens Healthcare Headquarters Global Siemens AG Healthcare Sector Henkestrasse 127 91052 Erlangen Germany Phone: + 49 9131 84-0 Legal Manufacturer Ultrasound 1230 Shorebird Way Mountain View, CA 94043 USA Phone: +1-888-826-9702 Order No: A91US-167-1C-4A00 011110. 01.2011,