Amendments to the Compendium of Classification Opinions



Similar documents
Amendments to the Compendium of Classification Opinions

Amendments to the Compendium of Classification Opinions

ECOCIAT. Domestic hot water heat recovery unit

Amendments to the Compendium of Classification Opinions

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

AUTOMOTIVE AIR CONDITIONING SYSTEM.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Amendments to the Compendium of Classification Opinions

Amendments to the Compendium of Classification opinions

SWIMMING POOL HEAT PUMP

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Amendments to the Compendium of Classification Opinions

SunMaxx Solar Filling Station Operating Instructions

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Refrigeration Installation 101

TWE+TTA TWE+TWA T.R.

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

AFE424 SERVICE PARTS

Installer s Guide 18-AH39D1-13

COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A

Installation Instructions

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

GENUINE PARTS INSTALLATION INSTRUCTIONS

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

Test Code: 8297 / Version 1

Amendments to the Compendium of Classification Opinions

Customized Assessment Blueprint

SECTION MORTUARY REFRIGERATORS

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

Acumen Enterprises, Inc.

ON-VEHICLE INSPECTION

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Reverse Cycle Inverter Split System Air Conditioner

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

Electronically Controlled Clutchless or Variable Drive Compressors

How Ground/Water Source Heat Pumps Work

SECTION HEAT PUMPS

Roof Top Unit. Description Model Type Use With Air Distribution Box. Heat Pump B Integral Mechanical

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

The Embassy of the United States of America invites you to submit an offer for supply and install the following A/Cs:

5800 Temperature Sensor Cable Assembly

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

Operators manual Basic water heater

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

CENTRAL AIR CONDITIONER SPLIT SYSTEM

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA

Air Conditioning Sign-Off Sheet

Condensing unit type EPSILON-ECHOS LE Technical information manual

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

SunMor SM-V30 Solar Water Heater Installation Manual

Air Conditioner Water Heater Model ACWH18

HVAC-02, Air Conditioning Troubleshooting and Repair

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Taurus Series YORK Window Air Conditioners

ADDENDUM NO. 1 TO THE BIDDING DOCUMENTS. HVAC SERVICE AND MAINTENANCE Saint Clair County MidAmerica Saint Louis Airport.

Failure code manual. content

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

marine/bespoke split applications

Decree of the Ministry of the Environment on fire safety of ventilation systems

Nominal Life Expectancy for Building Components

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

High School Graduation years 2013, 2014, Unit/Standard Number

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

york air-conditioning products Residential & VRF News 2015

Boiler Plan II Table of Contents

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Air conditioning service unit CAAS500

Dehumidifier D 850E. - Instruction manual version 02

1 DESCRIPTION OF THE APPLIANCE

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

SECTION GENERAL PROVISIONS FOR HVAC WORK

NSN

UNDERSTANDING CENTRAL HEATING SYSTEMS

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Refrigeration Basics 101. By: Eric Nelson

Fire Pump Plan Review March 2010

HOT WATER SYSTEMS.

Low Profile Unit Cooler

Cool Design for Homes and Offices

Glossary of Heating, Ventilation and Air Conditioning Terms

Name: Air Conditioning, Heating and Refrigeration ( )

Transcription:

Amendments to the Compendium of Classification Opinions The following list contains the decisions taken by the Harmonized System Committee (43 rd Session March 2009) concerning amendments to the Harmonized System Compendium of Classification Opinions. This publication will be updated regularly. The Harmonized System Compendium of Classification Opinions is published by WCO and consists of a numerical list, set out in the order of headings and subheadings of the Harmonized Commodity Description and Coding System, of the Classification Opinions adopted by WCO. Within any Harmonized System heading or subheading the Classification Opinions are listed in chronological order. The Compendium is available as a bilingual publication in English and French, the two official languages of the WCO, and can be ordered directly (see Bookshop on this Web site). The amendments listed below are reproduced in the order of the current pages concerned and will be incorporated into the aforementioned WCO publication in due time by replacing the pages affected by the amendments made. Advice Parties seeking to import or export merchandise covered by a decision are advised to verify the implementation of the decision by the importing or exporting country, as the case may be. º º º AMENDMENTS TO THE COMPENDIUM OF CLASSIFICATION OPINIONS Page IV/6a E. 2106.10 2. Preparation in the form of a powder, consisting of soya protein isolate (75.05 %), whey protein 80 % concentrate (24.5 %), vanilla aroma (0.25 %) and silicon dioxide (0.20 %), put up for retail sale, in a container with a net content of 240 g. The total protein content of the product, by weight of the dry matter, is 85.9 % (±1.0 %). The product is intended to be consumed with other foodstuffs or beverages (5 grams, 1 to 4 times daily). The product exhibits the smell and taste of vanilla. Page IV/9 E. 2106.90 25. A preparation known as coconut milk consisting of coconut flesh extract (57 %) and water (43 %), used for culinary purposes. The product is put up for retail sale in cans.

Page VI/4 E, Opinion 3203.00/4. Last line. Delete "Application of GIRs 1 and 6" and substitute "Application of GRI 1". Page VI/5 E. 3214.10 2. Polyurethane foam (sealing foam) based on plastics containing, among other additives, fire retardants and propellant gases, in the form of a dark brown liquid, presented for retail sale in a pressurised can (750/1000 ml). The pressurised can is emptied by applying pressure on the valve, during which the self-expanding foam is released, becoming white under atmospheric conditions. Once released, the foam hardens after 10 minutes. It is used for mounting window and door frames, filling cavities, sealing openings in roof construction and insulation materials, creating soundproof screens, filling cavities around pipes, fixing and insulating wall panels, roof tiles, etc. Page VI/7a E. 3506.10 1. Thread locker, a pale blue liquid, presented in plastic bottles of 50 ml with a dosage spout. It is used to seal and assemble parts which may need to be disassembled at some future date. It is a compound of polyglycol dimethacrylate, polyglycol dioctanoate, saccharin, cumene hydroperoxide, polyvinyl acetate and silica. Page XVI/2 E. Insert the following Classification Opinions : 8415.90 2. Outdoor refrigerating unit for a compression-type split-system air conditioning machine (cooling only), comprised of a compressor, a condenser heat exchanger coil, a motor-driven electric fan for drawing air over the condenser heat exchanger coil to evacuate the heat and other components for the control and protection of the unit, fitted together in a common housing. The unit is designed to be connected to one or more indoor evaporator units by electrical wiring and copper tubing through which the refrigerant circulates. Application of GIRs 1 (Note 2 (b) to Section XVI) and 6.

3. Outdoor refrigerating unit for a compression-type reversible, cooling or heating, split-system air conditioning machine, comprised of a compressor, a condenser heat exchanger coil, a motor-driven electric fan for drawing air over the condenser heat exchanger coil, a 4-way valve to reverse the cycle and other components for the control and protection of the unit fitted together in a common housing. The unit is designed to be connected to one or more indoor evaporator units by electrical wiring and copper tubing through which the refrigerant circulates. Application of GIRs 1 (Note 2 (b) to Section XVI) and 6. Page XVI/8 E. Insert the following Classification Opinions : 8451.30 1. Ironing machine designed for professional ironing operations, which consists of : (i) (ii) an electrically heated rectangular ironing table (dimensions : 125 cm (L) x 75 cm (W) x 87 cm (H); weight : 58 kg) with sleeve ironing board and built-in aspirator; a steam generator (weight : 15.5 kg) equipped with a silicon iron rest, a steam pressure gauge, a visible light-up water level gauge, a heating element with safety thermostat, a vessel for distilled water and a pump; (iii) an electrical steam iron (800 W). The ironing table is linked to the steam generator by a hose, and the steam is suctioned into the table by means of a foot pedal attached to the table. The steam iron is designed to be connected to the steam generator by a steam hose and an electrical cable. Application of GIRs 1 (Note 4 to Section XVI) and 6. See also Opinion 8451.90/1. "8451.90 1. Rectangular ironing table with sleeve ironing board and built-in aspirator. The surface of the table is electrically heated with a top heating element and the temperature of the surface is regulated by means of a thermostat. The table is designed to be connected to a steam generator. The steam is suctioned into the table by means of a foot pedal attached to the table. The table is intended to be used together with a steam generator and an electrical steam iron for professional ironing operations; the generator and the iron are not presented with the table. Application of GIRs 1 (Note 2 (b) to Section XVI) and 6. See also Opinion 8451.30/1.

. Page XVI/24 E, Opinion 8525.80/1. Fifth line. Delete "with charged coupled device (CCD)" and substitute "with charge-coupled device (CCD)". Page XVI/27 E, Opinion 8529.10/3. First sentence. Delete "to the low-noise down converter" and substitute "to the low-noise-block down converter". Page XVII/5a E. 8704.31 3. Multipurpose four-wheeled utility motor vehicle that features a front seat and an open rear cargo area. It is powered by a gasoline engine with a top speed of 21 kilometres per hour and has a load capacity of 545 kilograms (including operator, passenger, accessories and cargo). The vehicle is 2.8 metres in length and 1.26 metres in width with a turning clearance diameter of 6.7 metres. This vehicle is used for all kinds of jobs including turf care jobs. Application of GIRs 1 and 6. See also Opinion 8704.90/1.

. Page XVII/5a E. 8704.90 1. Multipurpose four-wheeled utility motor vehicle that features a front seat and an open rear cargo area. It is powered by an electrical motor, having a top speed of 21 kilometres per hour and load capacity of 450 kilograms (including operator, passenger, accessories and cargo). The vehicle is 2.8 metres in length and 1.26 metres in width with a turning clearance diameter of 6.7 metres. This vehicle is used for all kinds of jobs including turf care jobs. Application of GIRs 1 and 6. See also Opinion 8704.31/3. Page XX/4 E, Opinion 9602.00/1 Second paragraph, last line, Delete "electrodeposition" and substitute "electro-deposition".