Fire and Rescue Service Operational Guidance. GRA 5.8 flashover, backdraught and fire gas ignitions



Similar documents
GENERIC RISK ASSESSMENT 3.6 FIGHTING FIRES - USING POSITIVE PRESSURE VENTILATION

ARRANGEMENTS FOR HANDLING HERITAGE APPLICATIONS NOTIFICATION TO THE SECRETARY OF STATE (ENGLAND) DIRECTION 2009

Fire Development and Fire Behavior Indicators

CODE OF RECOMMENDED PRACTICE ON LOCAL AUTHORITY PUBLICITY

Treaty Series No. 12 (2013)

Flashover. Newsletter by Vincent Dunn-July 2000

Controlling fire and explosion risks in the workplace

December Newsletter by Vincent Dunn Backdraft and flashover, what is the difference?

Examples of pressure systems and equipment are:

Fire Safety Risk Assessment Checklist for Residential Care Premises

Surrey Fire & Rescue Service Report of Fire

Natural Gas Emergencies

Settlement Agreements

March 2015 Code of Practice 1 CODE OF PRACTICE ON DISCIPLINARY AND GRIEVANCE PROCEDURES

FLA S FIRE SAFETY INITIATIVE

WORKING IN CONFINED SPACES GUIDELINES

Fire and Rescue Service Operational Guidance. GRA 5.10 Working at heights

Material Safety Data Sheet

IFE Level 3 Certificate for Operational Supervisory Managers in Fire and Rescue Services (VRQ)

FLAMMABLE LIQUIDS COMPLIANCE NOTE

Guide Main use Offices and shops

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

Essence of Care. Benchmarks for Communication

The Current Knowledge & Training Regarding Backdraft, Flashover, and Other Rapid Fire Progression Phenomena

notes Video User s s Guide Accident Involving Radioactive Material

NEW FIRE SAFETY LEGISLATION

Compliance Document for New Zealand Building Code Clause F7 Warning Systems Fourth Edition

Installation Instructions for Alarm Module Kit A043F059

Based on the initial size-up and any information available, Command will formulate an action plan to deal with the situation.

Fire and Rescue Service Operational Guidance

IN CASE OF EMERGENCY. Emergency Telephone Number 112

FIRE SAFETY GUIDANCE NOTE Regulatory Reform (Fire Safety) Order 2005

: GLADE Aerosol - Lavender

Gambling (Licensing and Advertising) Act 2014

FIRE INVESTIGATOR LEAD EVALUATOR HANDBOOK

Treaty Series No. 28 (2005) Agreement

Written schemes of examination

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

LINCOLNSHIRE FIRE AND RESCUE

A Guide to the European Standard for Safety Storage Cabinets (BS EN )

Safe Operating Procedure

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

CONFINED SPACE PROCEDURE

Fire and Rescue Authorities Operational Guidance

WINDEX ORIGINAL GLASS CLEANER WITH AMMONIA-D

Safety Storage Cabinets

SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 3.1. Substances Not applicable 3.2. Mixture

English Victorian Semi-Detached House Fire.

small and medium places of assembly

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

MEMORANDUM TO THE BUSINESS, INNOVATION AND SKILLS SELECT COMMITTEE. Post-Legislative Assessment of the Further Education and Training Act 2007

SOUTH LYON FIRE DEPARTMENT Manual of Procedures 404

Take care with oxygen Fire and explosion hazards in the use of oxygen

Fire Safety Policy. Fire Safety Policy: May 2011 Page 1 of 6. Version 1. Scope:

SECTION 2: HAZARDS IDENTIFICATION Classification of the Substance or Mixture Classification (GHS-US) Not classified

Compressed Gas Cylinder Program

IGEM/UP/16 Communication 1756

SURVIVE INSIDE: Employee Safety in Confined Spaces

Managing fire safety in the workplace

Fire Safety Requirements for Child Care Centre

SAFETY SIGNAGE PROCEDURE

Notes. Material 1. Personal Protective Equipment 2.

Fire Risk Assessment Safety Checklist

FIRE RISK ASSESSMENT

MAIB SAFETY BULLETIN 1/2006. Fire on board the Bermuda registered cruise ship. Star Princess

Bastille Court 2 Paris Garden London SE1 8ND Telephone: Fax: training@thefpa.co.uk Web:

Fire is the rapid oxidation of a combustible material, releasing heat, light, smoke, and various toxic gases

ESCAMBIA COUNTY FIRE-RESCUE Implemented: 7/07//10 Revised:

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012

An inventory of hazardous materials used in your workplace will prove useful.

sleeping accommodation

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

Emergency Response Guide

Carriage of Dangerous Goods: Approved Derogations and Transitional Provisions

FIRE SAFETY GUIDANCE NOTE Risk Assessments for Petrol Filling Stations Required Under Fire Safety Legislation

This leaflet provides information on

SAFETY AND HEALTH PROGRAM

REGULATORY REFORM (FIRE SAFETY) ORDER Fire Risk Assessment. 145 Drury Lane Covent Garden London WC2B 5TA

: MR MUSCLE Window & Glass Cleaner

: Microscope Slide containing Various Human or Animal Blood samples

FIREFIGHTER SAFETY. Stay safe during substation fires

Australia No. 1 (2013) TREATY

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012

Service Standard Live Fire Training

Wilkins Safety Group

OCCUPATIONAL SAFETY AND HEALTH PROGRAM

Integrated Risk Management Planning Guidance Note 4:

Confined spaces can be deadly. What is a confined space?

Fire Risk Assessment For Simple Premises

HAZARD COMMUNICATION & THE GLOBAL HARMONIZING SYSTEM EMPLOYEE TRAINING

Time off for trade union duties and activities

The Smoke and Carbon Monoxide Alarm (England) Regulations 2015

Presented by: Rich Perry Marsh Risk Consulting

Transcription:

Fire and Rescue Service Operational Guidance GRA 5.8 flashover, backdraught and fire gas ignitions

Generic Risk Assessment 5.8 Flashover, backdraught and fire gas ignitions August 2009 London: TSO

Published by TSO (The Stationery Office) and available from: Online www.tsoshop.co.uk Mail, Telephone, Fax & E-mail TSO PO Box 29, Norwich, NR3 1GN Telephone orders/general enquiries: 0870 600 5522 Fax orders: 0870 600 5533 E-mail: customer.services@tso.co.uk Textphone: 0870 240 3701 TSO@Blackwell and other Accredited Agents Customers can also order publications from: TSO Ireland 16 Arthur Street, Belfast BT1 4GD Tel 028 9023 8451 Fax 028 9023 5401 Published with the permission of the Department for Communities and Local Government on behalf of Her Majesty s Stationery Office. Crown Copyright 2009 ISBN 978 0 11 754011 8 Copyright in the typographical arrangement and design rests with the Crown. This is a value added publication which falls outside the scope of the HMSO Class Licence. Applications for reproduction should be made to Office of Public Sector Information, Information Policy Team, Kew, Richmond, Surrey, TW9 4DU.

The Generic Risk Assessments in this series only apply to England. Contents SECTION 1 GRA 5.8 Flashover, backdraught and fire gas ignitions 5 Scope 5 Significant hazards and risks 5 Flashover 5 Backdraught 5 Fire gas ignitions 6 Key control measures 7 Recognition of the signs of backdraught and flashover 7 Training 8 Pre-determined attendance 8 Personal protective equipment 8 Incident command and control 9 Additional equipment 9 Technical references 10 Glossary 10 Neutral Pressure Place 10 Deflagration 10 Pyrolysis 10 SECTION 2 Summary of GRA 5.8 Flashover, backdraught and fire gas ignitions 11

SECTION 1 GRA 5.8 Flashover, backdraught and fire gas ignitions Scope This generic risk assessment (GRA) examines the hazards, risks and controls that relate to Fire and Rescue Service staff and others who may be affected when the phenomenon of Flashover, Backdraught or Fire Gas Ignition is experienced. As with all GRAs, this assessment provides a starting point for FRSs to conduct their own assessments within the context of local conditions and existing organisational arrangements. Significant hazards and risks Flashover In a compartment fire there may come a stage where the total thermal radiation from the fire plume, hot gases and hot compartment boundaries (ceilings and walls) causes the radiative ignition of all exposed combustible surfaces within the compartment. Where the compartment is adequately ventilated, this sudden and sustained transition of a growing fire to a fully developed fire is known as a flashover. Backdraught A backdraught is where limited ventilation can lead to a fire in a compartment producing fire gases containing significant proportions of partial combustion products and unburnt pyrolysis products. If these accumulate, the admission of air when an opening is made to the compartment can lead to a sudden deflagration. This deflagration moving through the compartment and out of the opening is a backdraught. There are two scenarios of which firefighters must be fully aware: Scenario 1 If the fire is still burning within a compartment when the door is opened, especially if the combustion gases are not escaping, the incoming air will mix with the gases and create an explosive mixture. If the gases within the compartment are hot enough, they will auto-ignite and flame will spread back into the compartment along with the fresh air. This would result in rapid fire growth, but not necessarily in a backdraught. Alternatively, if the gases are not sufficiently hot they will only be ignited once sufficient oxygen has reached the gases surrounding the fire. The flame will then travel across the compartment towards, and out of the doorway, driven by the expanding gases behind it. 5

Scenario 2 A more dangerous situation can occur if the fire in the compartment has almost died out. Once the door is opened air flows in and an explosive mixture may be created. There is the potential for ignition of these gases not to occur immediately. Once the firefighters enter the room however, and start to disturb the contents (e.g. turning over), an ignition source may be exposed and result in total flame engulfment. This is defined as a delayed backdraught. Fire gas ignitions Fire gas ignitions occur when gases from a compartment fire are leaked into an adjacent compartment and mixed with the air within this additional area. This mixture may then fall within the appropriate flammable limits that if ignited, will create an increase in pressure either with or without explosive force. Where this process occurs it is not necessary for an opening to be opened for such ignition to take place. If an explosive force is experienced, this is commonly termed a smoke explosion. Where an ignition occurs with much less pressure, the term flash fire is more appropriate. The backdraught, flashover and fire gas ignition phenomena described above can have potentially fatal outcomes. It should be recognised that although their outcomes may be similar the phenomena themselves are in fact significantly different in terms of the following: their pre-conditions evolution recognisable indicators. At one incident, in the same structure, there may well exist the preconditions for each phenomenon. Further detailed information of the nature and preconditions for backdraught, flashover and fire gas ignitions is provided in the Fire and Rescue Service Manual Volume 2 Fire Service Operations, Compartment Fires and Tactical Ventilation. Experience has shown that standard personal protective equipment (PPE), in itself, will not afford adequate protection against the effects of either flashover or backdraught. Therefore, it is vital that FRSs consider all the key control measures in order to reduce the risk to personnel to a tolerable level. 6

Key control measures FRSs should consider how they control the hazards and risks described above. Key measures are as follows. Recognition of the signs of backdraught and flashover The first consideration that there is a possibility of a backdraught occurring will be dependant upon the fire history. Therefore, as much information as possible should be gathered in the early stages of the incident. External signs of backdraught Fire in a compartment with limited ventilation: Fire has been burning for some time Fire gases being pushed out under pressure from gaps Windows blackened with no visible signs of flame Fire gases pulsing out from gaps. Internal signs of backdraught Fire in a compartment with limited ventilation: Low neutral pressure plane Darkening of fire gases Inrush of air and fire gases forced out, through the opening Pulsation of fire gases through an opening Deflagration through the opening. Signs of flashover Flames visible in the fire gases Combustible materials gassing off due to pyrolysis High temperatures, and increasing rate of combustion Neutral plane moving down Sudden increase in development of fire Pyrolysis at floor level in the compartment. 7

Training The level and nature of training undertaken should be based upon an informed assessment of the operational need for each Fire and Rescue Service and within agreed guidance for competency based training (CBT). Personnel engaged in an operational firefighting role should receive information instruction and training which should include: chemistry of combustion the effects of walls and the ceiling on the fire plume signs and symptoms of backdraught, flashover and fire gas ignitions door entry and gas cooling procedures safe system of work for dealing with incidents where flashover and backdraught may occur physiological stress and its management. The outcomes of training must be evaluated to ensure that the training is: appropriate effective up-to-date meeting the identified operational need. Pre-determined attendance FRSs should ensure that the operational response to a building fire will be sufficient to allow relevant safe systems of work to undertake the activity. This will initially be determined by information received from the caller and followed and supplemented by the assessment of the Incident Commander. Personal protective equipment PPE manufactured to the current accepted standard should be worn. When choosing suitable protective garments, the standard of clothing worn beneath the PPE should also be considered. Retained and auxiliary personnel may not have sufficient protection afforded by this clothing and therefore appropriate guidance/restrictions should be provided. 8

Incident command and control The National Incident Command System should be adopted on arrival at the incident. Where a high risk of backdraught is identified, consideration should be given to the initial adoption of defensive firefighting tactics. Detailed guidance on operational tactics is published in the Fire and Rescue Service Manual, Volume 2, Fire Service Operations Incident Command, 3rd Edition 2008. Ventilation of the premises should be conducted in a controlled and considered manner with due account taken of wind conditions. Effective communications are essential for this to be achieved. Ventilation points and exposed risks should be covered by water sprays to reduce the risk of external fire spread. Suitable communications will be needed to ensure that the Incident Commander and sector commanders are able to communicate at all times. The area outside the building on fire should be controlled (Inner Cordon Management) to reduce the number of persons at risk to the minimum necessary should a backdraught occur. This may include the tactical positioning of breathing apparatus entry control boards and fire appliances. Additional equipment An informed assessment of the risks within a FRS area will allow FRSs to consider the provision, and use of any additional equipment. Equipment may include: thermal imaging cameras ventilation tools hose reel spray branches PPV fans. 9

Technical references 1 Table of contents, Volume 3 Guide to Operational Risk Assessment 2 Fire and Rescue Service Manual Volume 2 Compartment Fires and Tactical Ventilation (1997) 3 Fire and Rescue Service Manual, Volume 2, Fire Service Operations Incident Command, 3rd Edition 2008 TSO 4 The principles of Operational Training Fire Service Circular 5/96 5 Institute of Occupational Medicine; Home Office, FRDG Fire Research Reports and Memoranda, 18/96 6 Study of the Physiological Effect of Wearing BA (Institute of Occupational Medicine). DFM letter and DCO letter 8/1997 (Management of Physiological Stress) 7 GRA 3.6 Fighting Fires Using PPV, HMSO 1998 8 BS EN 469 Protective clothing for firefighters & Personal Protective Equipment at Work: guidance on Regulations: Personal Protective Equipment at Work Regulations 1992 9 Dynamic Management of Risk at Operational Incidents, HMSO 1998 10 Home Office Technical Bulletin 1/97 Breathing Apparatus Command and Control 11 Euro Firefighter Global firefighting Strategy and Tactics, Command and Control, Firefighter Safety Paul Grimwood FIFireE Glossary Neutral Pressure Plane Fire in a compartment causes smoke and gases to rapidly expand with the hot gases rising due to their lower density and greater buoyancy. This results in a higher (positive) pressure in the fire room than the areas outside of the compartment. The forces, once fully developed, create an equilibrium whereby negative pressure relative to the outside, exists in the lower part of the room an positive pressure exists in the higher levels. Where these two zones meet is known as the Neutral Pressure Plane. Deflagration To burn or cause to burn with great heat and intense light. Pyrolysis Transformation of a substance produced by the action of heat. 10

SECTION 2 Summary of GRA 5.8 Flashover, backdraught and fire gas ignitions Ref. No Task Hazard Risk Persons at risk Control Measures 1 Entering an outer compartment potentially affected by a fire gas ignition Rapid fire spread Total flame engulfment of firefighters within the fire compartment Burns and scalds Fire and explosion Blast injury Wholetime Day crewed Retained Volunteers Other emergency service personnel Operational procedures as per FRS policy and supervision Training in identification of indicators and methods of attack PPE manufactured to the current accepted standard 2 Opening up a compartment containing oxygen starved fire Rapid fire spread/backdraught Burns and scalds Fire and explosion Blast injury Public Wholetime Day crewed Retained Volunteers Other emergency service personnel Operational procedures as per FRS policy and supervision Training in identification of indicators and methods of attack PPE manufactured to the current accepted standard 3 Working in compartment with flammable gases present and exposing a source of ignition Total flame engulfment of firefighters within the fire compartment Burns and scalds Fire and explosion Blast injury Public Wholetime Day crewed Retained Volunteers Public Operational procedures as per FRS policy and supervision Training in identification of risks. PPE manufactured to the current accepted standard 11

Ref. No Task Hazard Risk Persons at risk Control Measures 4 Carrying out tactical ventilation Rapid fire spread/backdraught Burns and scalds Fire and explosion Blast injury Wholetime Day crewed Retained Volunteers Other emergency service personnel Operational procedures as per FRS policy and supervision Training in identification of indicators and methods of ventilation PPE manufactured to the current accepted standard 5 Opening up a compartment where the thermal radiation generated by the fire is high, causing the room contents to give off flammable gases. Rapid fire spread/flashover Burns and scalds Fire and explosion Blast injury Public Wholetime Day crewed Retained Volunteers Other emergency service personnel Public Operational procedures as per FRS policy and supervision Training in identification of indicators and methods of attack PPE manufactured to the current accepted standard Explanatory Key Description Reference number for the risk Task the specific activity being carried out Hazard Hazard present giving rise to the risk Risk the chance, high or low, that somebody could be harmed by these and other hazards, together with an indication of how serious Persons at risk this should detail either employee, and / or member of public Control measures That could be used by the Service to reduce the risk 12