LT-82 Stationary IR Transmitter



Similar documents
Turbo X channel UHF true diversity

Hear The Future...Now! SIEM-2T/SIEM-2R

1 All safety instructions, warnings and operating instructions must be read first.

SZI IR Audio Transmission Technology Modulators/Radiators

Wireless. with Personal Mix Control and EP3 Dynamic Earphones

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

Features, Benefits, and Operation

PSM 900 and PSM 1000 Personal Monitor Systems TWO SYSTEMS. INFINITE POSSIBILITIES.

User Guide FFFA

Safety Warnings and Guidelines

Line Level Converter Box. S Class Signal Processors

IP Intercom System. Classroom intercom system for two-way voice communications, help desk support, and security/status monitoring.

IMPORTANT SAFETY INSTRUCTIONS

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

DAB+ / FM Tuner Model: TU-201

Amplifier: AMP Feature Summary

IP Intercom System

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

Praesideo - Digital Public Address and Emergency Sound System

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS khz

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Warranty

SLX WIRELESS SYSTEM The out-of-the-box wireless solution

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Warranty

HI-FI FM TRANSMITTER. MS-100 series INSTRUCTION MANUAL

R S E R I E S M I X E R S R R R

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

IRT Eurocard. Types DAX-3200

RMS-2FS Stereo FM Transmitter Monitoring System

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

QUALITY AV PRODUCTS INMATE/INMATE USB PROFESSIONAL 19" MIXER. User Guide and Reference Manual

Infrared Systems. Infrared Systems

PERSONAL MONITOR MIXER/HEADPHONE AMP. S Class Signal Processors

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE


Universal Host. Desktop Digital Hybrid. User Guide. JK Audio

5 CHANNEL MIXER. S Class Signal Processors

MANUAL PC1000R

Ideal CD player and FM tuner for use with other 301 Reference Series components also supports RDS and USB memory playback

Research RF Sputtering Packages

Zone Mixer. 6 channels configurable from 24 inputs. 3 zone outputs. Expandable via Sys-Link TM Built-in comp/limiter, ducking and alarm functions

HCS-3600MB2 Conference Main Unit

VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output

V0910 SENNSIS. Making Your Tour. State of the Art. TourGuide 2020-D

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS. drm TesT equipment

IT-12M IT-12D Ver_2.0 INTERPRETATION SYSTEM. User s Manual

PagePac PAGEPAL V

Model #: SMART2200CRMXL

PERF10 Rubidium Atomic Clock

How To Use A Pump Station 16-R

USER MANUAL. 914 Power Amplifier MODEL: P/N: Rev 1

UHF WIRELESS MICROPHONE SYSTEMS

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

VoiceTone T1 USER S MANUAL

PBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio

Tour Guide System. 2014, E-Top Technologies. All Right Reserved

CX Zoner Installation & User Guide

EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System

MISE - STEREO ENCODER

Desktop Headphone amplifier with Advanced DAC

SPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers.

PSP3. Stereo M/S preamplifier. User manual

LOXONE 12 Channel Amplifier

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

BLACK BOX Scalable matrix KVM switch supports up to 1024 ports with fiber or copper cable.

NV-EC1701. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Product Specifications

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

Focusrite Saffire 6 USB. User Guide

How To Use A Sound Card With A Subsonic Sound Card

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

USER MANUAL VS92A / VS94A / VS98A

HDO700 P FIBRE OPTIC TRANSMITTER

CAT5 VGA + Digital Audio Extender

AM / FM Tuner + RDS. Model: TU

1402VLZ4 14-Channel. Compact Mixer. FEATURES: 14-channel mixer featuring our signature high-headroom, low-noise design APPLICATIONS:

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

VERSATILE, UPGRADEABLE, SCALABLE.

NAVICOM DYNAMICS RTK BASE STATION INSTALLATION AND COMMISSIONING INSTRUCTIONS

RemoteMix 4. User Guide. JK Audio. Portable Broadcast Mixer

TS-770 SERIES CONFERENCE SYSTEM

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

Black Lion Audio 1800 W Cuyler Ave., Suite 2 East Chicago, IL

PGXD Wireless System. Shure PGXD Wireless. PGXD sans fil de Shure. Shure PGXD Sem Fio Shure Incorporated 27B14513 (Rev. 2) Printed in U.S.A.

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

F(t) Forssell Technologies Inc

Sympodium Interactive Pen Display

IRA 568. All in One. Infrared Column Soundfield System. Features: Recommend Applications: LINKX ELECTRONICS CO., LTD.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Transcription:

LT-82 Stationary IR Transmitter Configuration LT-82-0 (North America) LT-82-02 (Asia, UK) LT-82-03 (Euro) The Listen LT-82 is the heart of a stationary IR listening system. It takes the desired audio signal and transmits the signal via coaxial cable to one () or more IR radiator-emitters (LA-40). The LT-82 can be operated in mono or stereo on one () of four (4) different carriers; up to four (4) LT-82 units may be connected to provide up to four (4) mono or stereo carriers to the radiator(s). The LT-82 generates DC power to power up to two (2) LA-40 radiator-emitters. Two (2) LT-82 units can be rack mounted in a single rack space using the LA-326 rack mounting kit. The LT-82 is used for government compliance (such as ADA), assistive listening, language interpretation, live theatre, houses of worship, courtrooms, secure rooms and for auditory description. Secure wireless communication - ideal for applications where isolation of the signal is important. Up to four (4) channels mono, or four (4) channels stereo no need to sacrifice multiple channels to achieve stereo transmissions (one LT-82 is required for each channel). Transmitter can power two (2) radiator/emitters (LA-40) using CAT-5 cabling. Easy to specify, install and use. Outstanding performance - ensures crystal clear sound for listeners. Limited Lifetime Warranty. LA-40 Stationary IR Radiator Highlights Requires Used With LR-42 IR Stethoscope 4-Channel Receiver LR-44 IR Lanyard 4-Channel Receiver Architectural Specification The Stationary IR Transmitter shall be capable of broadcasting on four (4) mono or stereo carriers; 2.3, 2.8, 3.3 and 3.8 MHz. Channel Selection shall be capable of being locked. Multiple transmitters shall be capable of being daisy-chained together to transmit up to four (4) channels simultaneously. The transmitter shall have a timer that shuts off the carriers after 30 minutes when no audio is present at the transmitter. The transmitter shall have a SNR of 60 db or better. The device shall have an audio frequency response of 63 Hz to 5 khz, +/- 3db. It shall have two (2) mixing audio inputs, one () balanced XLR/ phone input and one () unbalanced RCA input. The device shall have the following audio controls: input level, transmit level, contour level and stereo on/off control. The device shall have an audio processor that is capable of automatic gain control and limiting. The transmitter shall provide power for up to two (2) radiators over CAT-5 cable. The LT-82 is specified. Includes LA-205 30 VDC Extension/Replacement Power Supply for LA-40/LT-82 LA-89 Interconnection Coaxial Cable uick Reference Card

5 6 7 2 8 3 4 9 5 Product Features. POWER on/off. 2. Controls input levels of inputs and 2. Dual VU meters indicate input level. 3. Mix level control sets level of the mixed (or transmitted) audio. VU meter shows the output level of your mixed audio. 4. Contour equalization cuts/boosts frequencies above 5 khz. 5. Processing (automatic gain control) can be turned on and off from the front panel. 6. Stereo indicator. When illuminated, indicates the unit is in stereo mode. Mode can be turned on and off from the front panel. 7. LCD shows channel selected, lock status, programming and carrier on. 8. Headphone jack and volume control to check audio integrity of transmission source. 9. UP/DOWN channel selection of up to four channels or carrier can be turned off. 0. Test tone provides flexibility when setting up and testing your system.. RF Input provides RF connection from other LT-82 units for multiple carrier interconnections. RF Output provides RF connection to LA-40 radiators. 2. In-line Universal Power Supply included [be sure to order the appropriate configuration (power cord) for your country]. Power supply has enough power for the LT-82 and up to two (2) radiators. Power Input is from the power supply, Power Output is to the radiators. 3. Two (2) phono connectors for a mixed output of Inputs and 2. 4. Two (2) unbalanced phono stereo audio inputs. Select either +0 dbu or -0 dbu input level. 5. Balanced XLR or phone connector audio input. Select either LINE, MIC or MIC-PH PWR (phantom power). 2

LA-70 Accessories Cables / Connectors LA-70 CAT-5e Cable (Per ft.) LA-7 RJ-45 CAT-5e Connector (0) LA-72 RJ-45 CAT-5e Coupler LA-2 RG-58 50 Ohm Coaxial Cable (Per ft.) LA-5 RG-58 BNC Coupler LA-27 RG-58 BNC Connector LA-326 Universal Rack Mounting Kit LA-39 RG-58 50 Ohm Preassembled Coaxial Cable (Per ft.) LA-393 CAT-5e Preassembled Cable (Per ft.) Mounting LA-326 Universal Rack Mounting Kit LA-326 3

RF Specification Carrier Frequencies Number of Channels Carrier Shut Off Frequency Accuracy Transmitter Stability RF Output RF Input Compliance LT-82 2.3 MHz, 2.8 MHz, 3.3 MHz, 3.8 MHz Four (4) channels. Selectable one () channel per transmitter (mono or stereo) Carrier will shut off when no audio is present for 30 minutes to preserve radiator life. +/-.005% stability 0 to 50C 50 PPM Two (2) BNC connectors, for connection to radiator(s) and/or additional transmitter(s). 50 mv, 50 ohm, -5 dbm One () BNC connector, for connection from additional transmitter(s). 50 mv, 50 ohm, -5 dbm FCC Part 5, Industry Canada, CE, RoHS Audio ** All system specifications are wireless end-to-end System Frequency Response System Signal to Noise Ratio (A-weighted) System Distortion Audio Input Audio Input 2 Audio Processing Contour Combined Audio Output (Mix) Monitor Output 63 Hz - 5 khz (+/- 3 db) Mono: >60 db Stereo: >52 db <2% total harmonic distortion (THD) Mono Input (Rear Panel). Female-XLR and /4 in. combo connector, balanced, 0/-55 dbu (line/mic) nominal input level adjustable; +2/-30 dbu (line/mic) maximum input level; impedance 20k/k ohms (line/ mic); phantom power +2 VDC Stereo or Mono Input (Rear Panel). Two (2) Phono connectors, unbalanced, -0/+0 dbu nominal input level adjustable, +30 dbu maximum, impedance 00k ohms Compression can be turned on/off. Cuts and boosts frequencies above 5 khz Input and Input 2 Mixed Output (Rear panel). Two (2) Phono connectors, unbalanced, -0 dbu nominal output level, +9 dbu maximum, impedance 0 ohms. Front panel. One () 3.5 mm (0.4 in.) connector, unbalanced, adjustable output level, +7 dbu maximum, impedance 0 ohms. 00 mw, 32 ohms Controls Front Panel Power, Test Tone on/off, Channel up/down, Input Level, Transmit Level, Contour, Monitor Level Rear Panel Input Level (Line, Mic, Mic-Phantom Power), Input 2 Level (-0/+0 dbu) Internal Adjustments Compression ratio for audio processor. Slope adjustable from : to 4:. Default 2: Programming Stereo on/off, Processing on/off Indicators Unit Power Input, Input 2, Transmit Level Stereo Processing RF Carrier LCD Test Tone Red LED illuminates when the unit is powered up (front panel) Indicates Input, Input 2, and Transmit audio levels. 0 segment LEDs (8 green, 2 red) Indicated by a green LED when on (front panel) Indicated by a green LED when on (front panel) Indicates carrier is active on the LCD Display (front panel) Channel designation, lock status, RF Carrier, programming (front panel) Red LED illuminates when test tone enabled (front panel) Power Power Supply Power Output Power Line Cord In-line switching mode power supply, Listen part number LA-205 Input: 00-240 VAC, 47-63 hz Output: 30 VDC,.5 A Output Connector: RJ-45 Compliance: UL and CE Listed Two (2) RJ-45 jacks. For remote powering up to two (2) radiators. North America, Type B. (LT-82-0) Asia, UK, Type G. (LT-82-02) Euro Type J. (LT-82-03) Physical Dimensions (H x W x D) Color Unit Weight Unit Weight with LA-205 Power Supply Shipping Weight Rack Mounting.75 x 8.50 x 9.3 in (4.5 x 2.5 x 23 cm) Dark grey with white silk screening 2.6 lbs (.8 kg) 3.8 lbs (.72 kg) 4.4 lbs (2.00 kg) One () rack space high (U), /2 rack space wide. One () or two (2) transmitters can be mounted in a single rack space. Optional rack mount (LA-326) not included. Environmental Temperature - Operation Temperature - Storage Humidity 4 F (-0 C) to +04 F (40 C) -4 F (-20 C) to +22 F (50 C) 0 to 95% relative humidity, non-condensing Specifications are subject to change with out notification. 4

Stationary IR Block Diagram Basic Single Channel/Single Radiator System LA-40 IR Radiator Power CAT-5 Cable RF RG-58 50 ohm Cable IR LR-42 Stetho IR Receiver Mounting hardware for radiator included with radiator LR-44 Lanyard IR Receiver Stationary IR Block Diagram Multi-Channel/Radiator System Up to four LT-82 transmitters can be daisy chained together (using RG-58 cable) to create a multi-channel system Power CAT-5 Cable RF RG-58 50 ohm Cable Up to 00 LA-40 radiators can be daisy chained together (using RG-58 cable) to provide sufficient IR power for most applications LA-40 IR Radiator IR LR-42 Stetho IR Receiver RF RG-58 50 ohm Cable Power CAT-5 Cable LA -89 RG-58 Multi-carrier Interconnection Cable (included) IR LA-40 IR Radiator LR-44 Lanyard IR Receiver Radiator Power: Radiators can be powered from the LT-82 (up to two radiators) or an additional power supply (LA-205) can power up to two radiators Radiator RF: RF from the last LT-82 must be daisy chained from radiator to radiator 5

Related Systems LS-80 Basic Stationary IR System () LT-82-0 Stationary IR Transmitter () LA-40-GY Stationary IR Radiator (4) LR-42 Stationary IR Stethoscope 4-Channel Receiver (4) LA-363 High Capacity AAA Alkaline Batteries (2) () LA-304 Assistive Listening Notification Signage Kit LS-8 Performance Stationary IR System () LT-82-0 Stationary IR Transmitter () LA-326 Universal Rack Mounting Kit (2) LA-40-GY Stationary IR Radiator (4) LR-42 Stationary IR Stethoscope 4-Channel Receiver (4) LA-363 High Capacity AAA Alkaline Batteries (2) () LA-35 Stationary IR Storage Station () LA-304 Assistive Listening Notification Signage Kit LS-82 Advanced Installed IR System () LT-82-0 Stationary IR Transmitter () LA-326 Universal Rack Mounting Kit (2) LA-40-GY Stationary IR Radiator (8) LR-42 Stationary IR Stethoscope 4-Channel Receiver (8) LA-364 NiMH Rechargeable Battery Pack for Stationary IR Receivers () LA-350-0 8-Unit IR Charging/Storage Station () LA-304 Assistive Listening Notification Signage Kit LS-83 4-Channel, 48-Listener Stationary IR System (4) LT-82-0 Stationary IR Transmitter (2) LA-326 Universal Rack Mounting Kit (3) LA-89 Interconnection Coaxial Cable (8) LA-40-GY Stationary IR Radiator (48) LR-42 Stationary IR Stethoscope 4-Channel Receiver (48) LA-364 NiMH Rechargeable Battery Pack for Stationary IR Receivers (6) LA-350-0 8-Unit IR Charging/Storage Station (2) LA-304 Assistive Listening Notification Signage Kit LS-84 Expanded Performance (2-Channel) Stationary IR System (2) LT-82-0 Stationary IR Transmitter () LA-326 Universal Rack Mounting Kit () LA-40-GY Stationary IR Radiator (5) LR-42 Stationary IR Stethoscope 4-Channel Receiver (5) LA-364 NiMH Rechargeable Battery Pack for Stationary IR Receivers () LA-350-0 8-Unit IR Charging/Storage Station () LA-304 Assistive Listening Notification Signage Kit LS-85 Expanded Basic Stationary IR System () LT-82-0 Stationary IR Transmitter () LA-326 Universal Rack Mounting Kit () LA-40-GY Stationary IR Radiator (3) LR-42 Stationary IR Stethoscope 4-Channel Receiver () LR-44 Stationary IR Lanyard 4-Channel Receiver () LA-66 Neck Loop () LA-65 Stereo Headphones (4) LA-363 High Capacity AAA Alkaline Batteries (2) () LA-304 Assistive Listening Notification Signage Kit 6

Frequently Asked uestions How many carriers does the LT-82 produce? A One. How many carriers can be produced simultaneously in a room? A Four. You will need one () LT-82 per carrier. How do you interconnect multiple LT-82 units? A Units are daisy chained using a short piece of coax cable (supplied with each LT-82). Is there any performance degradation in stereo mode? A Yes, stereo operation raises the noise floor slightly. Can I operate some channels in mono and others in stereo? A Yes. How many radiators does the LT-82 power? A The LT-82 powers up to two (2) Listen LA-40 radiators. How are radiators connected to the LT-82? A The carrier (signal) is connected using coax cable; power is connected using standard CAT-5 cabling. Can the LT-82 be operated on 230 VAC? A Yes, the LT-82 has a universal power supply that can be used anywhere in the world. What happens if the radiator power cable is shorted? A To protect the system, the LT-82 will shut down the power to the radiator cable until the problem is eliminated. Can I use the LT-82 with other manufacturers radiators? A Yes, but the LT-82 will not power those radiators. 7