Instruction manual for Firstline FCS12000CH



Similar documents
SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

Portable Air Conditioner

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Split Type Room Air Conditioner. KSWM units

Operating Instructions Air Conditioner

Split Air Conditioner

SPLIT TYPE AIR CONDITIONER INDOOR UNIT MODEL RAK-18QH8(W) RAK-25QH8(W) RAK-35QH8(W) RAK-50QH8(W) RAK-18QH8(B) RAK-25QH8(B) RAK-35QH8(B) RAK-50QH8(B)

INDOOR UNIT/OUTDOOR UNIT

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

OMI-09/OMO-09 OMI-12/OMO-12 OMI-18/OMO-18 OMI-24/OMO-24. Wall Mounted Unit

INDOOR UNIT/OUTDOOR UNIT

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

R410A SPLIT SERIES DC INVERTER

Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Operating Instructions Split System Air Conditioner

Important Safeguards

AIR CONDITIONER (SPLIT TYPE)

Room Air Conditioners

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

REMOTE CONTROL MANUAL

USER S MANUAL HSC-24A

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

OWNER S MANUAL SPLIT SYSTEM AIR CONDITIONER. G Series Cooling

Inverter Single Zone Ductless Mini Split Heat Pump

Contents. Correct Disposal of This Product (Waste Electrical & Electronic Equipment)

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Dehumidifier Users manual. For Models: DH45S DH65S

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Meaco 30L and Meaco 40L dehumidifier instruction manual

LG Room Air Conditioner OWNER'S MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

LG Floor Standing-Type Air Conditioner OWNER'S MANUAL

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Operating Instructions Air Conditioner

OPERATING INSTRUCTIONS INDOOR UNIT MSZ-A18YV MSZ-A24YV MSZ-A26YV MSZ-A30YV

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

OPERATING INSTRUCTIONS INDOOR UNIT MSZ-GA50VA MSZ-GA60VA MSZ-GA71VA MSZ-GA80VA

WINDOW ROOM AIR CONDITIONER

OPTIONAL SLENDER REMOTE CONTROL

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED

SAFEGUARDING THE ENVIRONMENT

Operating Instructions

LG Multi Type Air Conditioner

AIR CONDITIONER Duct Type OPERATING MANUAL

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Split Air Conditioner

Owner s Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E. Model name:

Reverse Cycle Inverter Split System Air Conditioner

PORTABLE AIR CONDITIONER

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

RMI-1103-A SERVICE MANUAL MIDEA AIRCONDITIONER EUROPE MARKET DC INVERTER MULTI TYPE R DC INVERTER MULTI SERIES

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

DUCT TYPE AIR CONDITIONER

LG Room Air Conditioner OWNER'S MANUAL

Air Conditioner user manual

Operating Instructions

SPLIT-TYPE AIR CONDITIONERS

DAIKIN ROOM AIR CONDITIONER MODELS. Operation Manual ENGLISH ESPAÑOL TURKISH

DAIKIN ROOM AIR CONDITIONER FT50BSG FT60BSG MODELS. Operation Manual

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

All about the Use &Care

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

and using this appliance and keep this manual for future reference.

PORTABLE AIR CONDITIONER

LG Room Air Conditioner OWNER'S MANUAL

Air Conditioner. user manual. imagine the possibilities

The figures in this manual may be different with the material objects, please refer to the material objects for reference.

Taurus Series YORK Window Air Conditioners

HIGH-WALL DUCTLESS AIR CONDITIONING SYSTEM

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

Contents. PREPARING YOUR AIR CONDITIONER Safety Precautions... 3 View of the Indoor unit... 8

DAIKIN ROOM AIR CONDITIONER FTKD50BSG FTKD60BSG FTKD71BSG MODELS. Operation Manual

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

AIR CONDITIONER OWNER S MANUAL. ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH πãõ PORTUGUÊS NEDERLANDS

LG Ceiling Cassette-Type Air Conditioner

Split Air Conditioner

features of your new air conditioner

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL

SPLIT-TYPE AIR CONDITIONERS

Cassette Type_E_26442.indd ソタネト 6:18:33

Failure code manual. content

DC INVERTER (WALL TYPE) INDOOR UNIT OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT RAS-18FH6 RAC-18YH6. 1 PHASE, 50 Hz, V

Transcription:

Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of Air Conditioner... 8 Operation of Air Conditioner... 9 Operation of Air Conditioner... 11 Service and Maintenance... 12 Service and Maintenance... 13 Fault Confirmation and Analysis... 14 Page 1 of 15

Introduction Thank you for choosing to install your Firstline FCS12000CH Air Conditioning unit. We hope you find these instructions useful. If you have any suggestions to improve them then please let us know. Your installation comes with a two year guarantee. from././. to./ /. Suggested maintenance due date is../. We also offer the following services :- Basic Filter Clean 10 Standard Service 35 Re- Gas 35 (obviously free to existing customers within warranty period) Service contract includes all of above per month :- 5 We also supply and fit Firstline units within the UK Ideal for Conservatories Page 2 of 15

Safety Awareness Please read and understand thoroughly the safety awareness guidelines before use. The items indicated here are very important safety precautions which must be followed. Must be connected to a Earth Grounding line Absolutely none Must unplug plug Must be done Do not pull the power cable. Hold plug to unplug when disconnecting power or part of the cable may break and cause fire. Do not let cool air blow directly at for long periods. Possible health problems may occur. Do not connect at the middle of the power cable or extend it Do not use multi hole sockets. Possible fire or electric shock may occur for poor connection, bad insulation and excessive allowable current. Do not plug power cable when in operation (Spark may appear and cause fire). Pull the power plug out of the outlet or cut off the power supply when you don t use the air conditioner for a long time. Accumulated dirt may cause fire. Do not damage power cable or do joining work. It may cause short circuit or electric shock. Provide a power outlet to be used exclusively for each unit and power supply disconnect and circuit breaker.. Page 3 of 15

Safety Awareness Clean the air conditioner with a soft dry cloth. Do not use chemical solvent, insecticide, inflammable-spraying material or which damage the appearance of the air conditioner for cleaning. The appliance shall be installed in accordance with national wiring regulations. The appliance must not be installed in the laundry. The appliance must be installed 2.3m above the floor. The appliance must be positioned so that the power can be disconnected.. Do not put burning appliances at the place where air can be blown directly by the conditioner or insufficient burning may occur. Do not install the air conditioner near flammable gas storage as. If there is accidental electrical short circuit from the air conditioner it may cause fire or explosion from the flammable gas. Stop operation and disconnect power immediately if there is a burning smell from the unit. Do not use for special purposes such as to store precession equipment, food and paintings. Close windows and doors while operating the air conditioner. Do not operate air conditioner at cool/dry mode for a long time under high humidity (above 80%). Page 4 of 15

Name of Parts Outdoor Unit Page 5 of 15

Name of Parts Remote Control Unit Page 6 of 15

Remote Controller Preparation Open back cover, insert batteries. Press the button with a pointed object to adjust the time. Press the HR and MIN buttons to set the correct time. Press the button again tos et the time. Warning If the remote control operation does not appear to be working, replace the batteries and try again. The Remote controller should be less than six metres away from the indoor unit. Treat the remote control carefully. Do not allow it to fall to the floor. When a button is pressed, the indoor unit will emit a beep once or twice. Remove the batteries if the remote control is not going to be used Page 7 of 15

Operation of Air Conditioner 1 Run/Stop Press the I/O button to Start and Stop the operation. 2 Temp Adj Press the Temp Adj button to increase or decrease the temperature by 1 degree. 3 Fan Adj Press the Fan Adj button to vary the speed of the fan from Low, Medium. High and Auto 4 Sleep Select the Sleep button to set the sleep operation which sets the room temperature to a comfortable level and maintains it overnight. 5 Air Flow Change the air flow direction by pressing the Manual Swing button from 1 5 angles. In Dry or Cool mode, air blows downward in positions 4 5 for one hour and revert to horizontal blowing automatically to prevent possible condensation drips. By pressing the Auto Swing button, the deflector swings automatically. The air flow can be directed left and right by manually adjusting the deflectors. Complete the adjustment before operation as the swinging deflector may trap your fingers. Page 8 of 15

Operation of Air Conditioner In Dry or Cool mode its advised to select the deflector in AUTO mode as air blows at point (1). In heat mode, selecting AUTO deflect at point (5). Control the deflector with the remote controller and avoid turning deflector with hand to prevent injury. Page 9 of 15

6 Mode Adjustment a. Auto Mode When selected the unit will turn into COOL,DRY or HEAT mode depending on room temperature. Operation stops for two hours and restarts in the same mode set as before operation was stopped. Once operation mode is set, it will not be influenced even if room temperature has changed. Press MANUAL SWING button or SWING button to change air flow direction. b. Cool Mode Press MANUAL SWING button or SWING button to change the up/down air flow direction. Press FAN SPEED button to control the fan speed of the indoor unit. Press the TEMPERATURE ADJUSTMENT button to change to the required temperature. c. Dry Mode Dehumidifies the room. Press the SWING and FAN controls as above for desired settings. d. Fan Mode This mode acts as a normal fan would by recycling the air. e. Heat Mode Use the same controls as COOL MODE except select a lower temperature. Page 10 of 15

Operation of Air Conditioner 7 Timer Operation Check to make sure the remote control is indicating the correct time. If not, set the correct time using the steps described earlier. Select time operation Press -I to choose start time when air conditioner is not operating. Press -O to choose stop time when air conditioner is operating Setting time When -I or -O flashes on the display, setting time function is active. When -I flashes in the display, press HR and MIN to the time you require the machine to start. When -O flashes in the display, press HR and MIN to the time you require the machine to stop Time on and time off can be combined to control the machine operation. The direction shows the sequence of the function and the function nearest the present time is first activated. Time Cancel Press -I to cancel time on. Press -O to cancel time off. Page 11 of 15

Service and Maintenance For units not used for a long time Start the unit on FAN ONLY for 3-4 hours to completely dry the unit before setting to COOL or HEAT mode. For units not to be used for a long time Turn off the air conditioner, disconnect the power supply and take the batteries out of the remote control. Page 12 of 15

Service and Maintenance Deodorization filter, Air Cleaner must be cleaned every couple of months. Open front panel only after air conditioner stops completely. Take out the filters Clean filters with a vacuum cleaner or by tapping them gently. If they are very dirty you may clean them in warm water. Rinse in clear water and dry in cool air Insert filters in original position Page 13 of 15

Fault Confirmation and Analysis Air conditioner does not operate at all Possible power failure Is plug out Does power fuse Is timer set Remote control does not work and does not display If disturbed abnormally or operation modes changed too quickly sometimes this causes the controller to lose function. Please turn power off and on again If remote control displays are unclear, please change the batteries. Unit not running straight away when I/O button selected Sometimes the microprocessor acts in a way to protect the compressor. Please leave for 5-10 minutes. Cooling and heating efficiency is not good Temperature set suitably? Filters Dirty Inlets and outlets of outdoor unit blocked. Sleep function set Indoor fan speed set to low Open doors and windows Air not immediately blown out at start of Heat mode The unit is processing information and will only blow when sufficiently warm Page 14 of 15

Indoor unit fan stops for about ten minutes during heating It is defrosting the outdoor unit coil. It should complete this process in about 10 minutes at most. It freezes when outdoor temperature is low and humidity is high. Unit issues cracking sounds These are friction sounds caused by expansion and contraction of the front panel of the unit resulting from temperature changes You can hear the sound of running water It may be the sound of expanding refrigerant inside the unit Sound of accumulated water dropping on the heat exchanger Indoor unit issues poosh sound and click. Click sound is the fan and compressor when switching on and off. Poosh sound is refrigerant inside the conditioner Outdoor unit leaks water This is a normal process in the cycle Page 15 of 15