Installation Instructions



Similar documents
INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

HEAT WAVE DUCT KIT KIT #

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR INTERNATIONAL 9000 SERIES ROOF TOP AIR CONDITIONERS

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades

HVAC INSTALLATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

Cooktop Low-Profile Ventilation Hoods

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

ASX7-4-IOM-7 J

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

E2 Series Electric Furnaces

Diagnostics for Mobile Homes: HVAC

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR INTERNATIONAL 8000 SERIES ROOF TOP AIR CONDITIONERS

3 IN 1 BATHROOM HEATER

Installation Instructions

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

4 Installation Requirements

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

101 Low-Cost /No-Cost. Home Energy-Saving Measures

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting

Cooling Capacity CFM in. w.c. (125 Pa)

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

Ceiling Mount Air Handler Manual

MODEL FAI4 FRESH AIR INTAKE KIT

Flue Installation. High Efficiency Condensing Boilers

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Ducoterra Radiant Heating Panel Installation Manual

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Before installation it is important to know what parts you have and what the capabilities of these parts are.

GENUINE PARTS INSTALLATION INSTRUCTIONS

Glossary of Heating, Ventilation and Air Conditioning Terms

TYPE. MODEL B3200 Roof-Top Air Conditioner used with Mechanical Air Distribution Box INSTALLATION & OPERATING INSTRUCTIONS Air Conditioner

5800 Temperature Sensor Cable Assembly

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Installation Questions

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Home inspectors are not mold inspectors, however they do inspect for defects that

XL PREMIUM OIL COOLER KIT

PANELIZED HOME INSTALLATION GUIDELINE

Model. Roof-Top Air Conditioner CARAVAN MODEL B3200 TYPE INSTALLATION & OPERATING INSTRUCTIONS B3200

Installation Instructions

How To Install An Evaporator Coil

BPI Air Conditioning & Heat Pump Professional Training Sample Slides ( ) Agenda

REMOTE AUXILIARY AIR CONDITIONING AND AIR DISTRIBUTION SYSTEMS FOR VOLVO L-4 CHASSIS

Roof Top Unit. Description Model Type Use With Air Distribution Box. Heat Pump B Integral Mechanical

CUSTOM AUXILIARY FORWARD LIGHTING KIT

CLOSED CRAWLSPACES. Have you ever been in your crawlspace? If not, have you ever even

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

Air Conditioner B B

Installation Instructions

Development Services City of Lawrence, KS

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N

Your safety and the safety of others are very important.

Cabinets 101: Configuring A Network Or Server Cabinet

QT Residential Blower Metal Residential Blower

Accessory Manual Ventilation Section Model Comfort Circle

foundation ventilation systems for moisture and termite control

Acumen Enterprises, Inc.

REMOTE AUXILIARY AIR CONDITIONING SYSTEM AND AIR DISTRIBUTION

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Arctic Leash Instruction Manual Alaskan Products Company LLC.

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

OWNER S GUIDE OPERATION & INSTALLATION

INSTALLATION INSTRUCTIONS

Cooling system components, removing and installing

Ceiling Fan Installation Instructions

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

COOLING SYSTEM Section Page

Chapter 8. Duct Design and Sealing

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

PACKAGED TERMINAL AIR CONDITIONER (PTAC) / PACKAGED TERMINAL HEAT PUMP (PTHP) AND ACCESSORY INSTALLATION INSTRUCTIONS

Reverse Cycle Inverter Split System Air Conditioner

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

For Models #6-5001, #6-7501, # & #10-12K1

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Installation Instructions S

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

INSTALLATION MANUAL INSIDE PASSENGER COMPARTMENT. HFC 134a FOR EUROPEAN SPEC. / GENERAL SPEC. AIR CONDITIONING ENGLISH

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

H41 Electrical Stage Aft Air Conditioner Unit Installation

Geyser-R Heat pump water heater Installation manual

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Installation Instructions

HVAC Code Requirements

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Transcription:

VentilAire IV Whole-House Fresh Air Supply System Installation Instructions 914228 Flat Roof Kit 914229 Sloped Roof Kit 5" x 11' Class I Insulated Flexible Duct Plastic Clamps (2) Metal Clamps (2) Ceiling Ring Sheet Metal Screw (For optional mounting location) Plastic Inlet Fitting with Snap Fits Components Included in Each Kit Kits conform to H.U.D. Manufactured Home Construction and Safety Standard for ventilation, paragraph 3280.103(b)(2)(1-6). Effective May 30, 2006. These instructions are primarily intended to assist qualifi ed individuals experienced in the proper installation of heating and/or air conditioning appliances. Some local codes require licensed installation/service personnel for this type of equipment. All installations must be in accordance with these instructions and with all applicable national and local codes and standards. Before beginning the installation, read these instructions thoroughly and follow all warnings and cautions in the instructions and on the unit. Introduction The VentilAire IV assembly provides fresh air to the living space and ventilation of the attic. VentilAire IV is an efficient way to introduce outdoor freshness to interior environments. It works in conjunction with the furnace blower and existing duct system and is able to work independently when the heating and cooling system is off. Best of all, VentilAire is a costeffective way to substantially improve air quality and help control attic condensation in manufactured homes.

2

The attic ventilator is a power ventilator which automatically provides attic ventilation to reduce winter condensation and summer heat build up in the attic. To control condensation the ventilator operates at relative humidity levels above 40 percent and temperatures above 35 F. To control heat build-up the ventilator operates at temperature above 110 F. The VentilAire system is designed for use with all NORDYNE manufactured housing series gas, oil and electric furnaces and air handlers. Warranty NORDYNE offers a limited warranty with the purchase of your new VentilAire system. The system is warranted for one (1) year, Parts and Labor, against any defects in materials and/or workmanship. Due to many variable factors and conditions which the VentilAire System cannot control, the system is not warranted to prevent or cure moisture condensation problems in the home. How It Works: The home s Thermostat is the control device for selecting continuous Whole-House Ventilation. When the Thermostat is in the WHOLE-HOUSE VENTILATION position, the unit blower will operate continuously; independent of COOL or HEAT modes. When the furnace blower is operating, a negative pressure (suction) is created in the furnace plenum. This suction draws in fresh outdoor air which is mixed with the homes return air then distributed through the home duct system. When HEAT or COOL modes are selected, the fresh outdoor air and home return air are conditioned prior to being distributed throughout the home. Attic Ventilator-Winter When the attic space humidity level is above 40 percent R.H. and temperatures are above 35 F the ventilator will operate. The ventilator draws in fresh outside air and exhausts moisture laden air out of the attic space. This helps to reduce condensation problems. Summer when the attic space temperature is above 110 F the attic ventilator will operate. The ventilator draws in cool outside air and exhausts hot air out of the attic space. This helps reduce heat build-up in the attic, thus reducing the air conditioning load. Installation Instructions DO NOT REMOVE THE OVAL KNOCKOUT IN FURNACE TOP BEFORE COMPLETING STEP ONE. 1. Determine the location of the plastic inlet fitting. Gas Furnace (See Figure 1)- Oval knockout located at the top, near the front of the furnace. Air Handler - Oval knockout located on the sides of the air handler. Downflow Electric Furnace (see Figure 1) - The plastic inlet fitting may be mounted in the rear of the cabinet over the return air filter. When using an optional air conditioning coil, it may be mounted to the front or rear coil end-plate flange using the mounting holes provided. An optional VentilAire Attachment Kit may be purchased to attach the plastic inlet fitting to the coil or wall in Heat/Cool and Heat only (no coil) applications. The plastic inlet fitting snaps into the Bracket opening without screws. The kit is Nordyne part number 919328; bulk kit with 24 brackets along with fasteners. Electric Furnace Gas Furnace Mounting Holes Optional A/C Coil Figure 1. Plastic Inlet Fitting Location 3

Wall Mounting or Unit Mounting A/C Coil Mounting Wall WALL Wall Mounting Holes NORDYNE Unit Mounting Holes Optional Attachment Kit (Wall or Unit Mounting) Optional Attachment Kit (wall or unit mounting) Figure 2. Downflow Electric Furnace with A/C Electric Furnace with Nordyne A/C coil (see Figure 2) - Align and fasten the Ventilaire Attachment bracket with the holes of the Nordyne coil end-plate fl ange. Electric Furnace with non-nordyne A/C coil (see Figure 2) When using other brands of coils, the installer has the option to attach the bracket to the wall of the furnace cavity. Fastening must penetrate into a framing member or sheetrock anchors. Electric Furnace, Heating only, no coil (see Figure 3) The bracket may also be mounted directly to the front of the Electric Furnace. In wall mounting applications, the bracket should be positioned at the rear of the unit with the entire bracket opening located over the return air inlet. Roof Vent Figure 3. Downflow Electric Furnace with Heat Only Roof Cap 3' min. 3' min. 36 sq. in. at each end of home recommended per ventilator Furnace Flue Figure 4. Roof Spacing FURNACE ROOF JACK FRESH AIR AIR INLET ATTIC VENTILATOR ROOF SEALANT ROOF ATTIC FLEXIBLE DUCT BLOWER CEILING CEILING RINGS DO NOT BLOCK OPENING BACK OF FURNACE FLOOR REGISTER DUCT SYSTEM Figure 5. General Install Setup 4

NOTE: In all applications, the VentilAire system should be positioned no more than two inches (2 ) from the return air inlet opening of the Furnace or Coil without interfering with the fi lter or coil fi ns. Upflow Electric Furnace - a special adaptor (914427) may be applied over the square refrigerant line knockout. 2a. For oval knockout installation, place the plastic inlet fi tting with locking tabs onto the sheet metal. The side with tabs further apart (back) should be inserted first, then push gently on the front in the center of the part until front tabs fall below the sheet metal and release. Part will tighten securely in place after application of metal clamp. 2b. For optional locations use the sheet metal screw provided through one of the clearance holes on the plastic inlet fl ange. 3. Cut approximately a 7-inch diameter hole in ceiling directly above the duct fi tting. Avoid ceiling joists and other obstructions in the ceiling cavity and keep debris from falling into furnace. 4. Determine location of roof opening. The roof cap assembly should be located as closely as possible to the center of the home, allowing connection of the fresh air intake to the furnace using the 11-foot length of fl exible duct provided (See Figure 4) on page 4. Supply Cable Roof Wiring Box Ground Wire (No Insulation) Hot Wire Neutral Wire (Black) (White) Figure 6. Hot, Neutral, and Ground Wire Connections Assembly Joist Figure 7. Ventilator Roof Alignment HUMIDISTAT SWITCH 110 F SUPPLY CABLE CONNECTOR SUPPLY WIRING UNIT WIRING NOTE: Wire nuts not supplied. Figure 8. VentilAire IV Wiring Diagram 5

Caulk or Sealant Figure 9. Sealant Application CAUTION: The air inlet cap MUST be located at least 3 feet from any plumbing vent or exhaust vent (gas or oil furnaces, water heater, fireplace, etc.). Note: The attic must be vented to the outside at each end of the manufactured home. This venting is recommended to be a minimum of 36 sq. in. of free open area at each end of the home, preferably at the roof or at the eave. Other locations may be used as long as they are located so as to provide even air movement through the attic space. On double-section manufactured homes at least one vent on each side of each end on the home must be used (minimum of 4-vents, total), preferably at the roof or at the eave. These vents are recommended to have at least 18 sq. in. of free area each. There must also be an opening in the marriage wall of at least 144 sq. in. for proper venting. 5. Cut approximately a 9 x 19 opening in roof. Note: Separate round openings of 9 and 6 may be cut on 12 centers if desired. 6. Route flexible duct through ceiling hole between the roof opening and the furnace area. 7. Attach one end of fl exible duct to bottom flange of air intake opening. Secure the inner duct with one of the metal clamps provided and the insulation duct with one of the plastic clamps provided. 8. Electrical hook-up. Refer to wiring diagram in figure 8 on page 5. a. The ventilator is equipped at the factory with a wiring box and connector for 14/2 or 12/2 ROMEX supply cable with ground, or equivalent. b. Connect HOT wire to BLACK lead and NEUTRAL wire to WHITE lead. Secure connections with suitable wire nuts (See Figure 6) on page 5. c. Connect GROUND wire at appropriate ground connection (wiring box green grounding screw). 9. Apply appropriate caulking or roof sealing material to ventilator cap assembly. Apply compound to underside of ventilator cap flashing to form a continuous strip around the underside of the perimeter of the flashing as seen in figure 9. VentilAire III and IV Application Chart Furnace Fresh Air Supply CFM - Blower Speed Model Low Med-Low Med-High High M1*B 50 (1,429) 65 (1,857) 85 (2,429) M1*C 60 (1,714) 70 (2,000) 80 (2,286) 90 (2,430+ *) M2RC 75 (2,143) 90 (2,430+ *) M2RL 80 (2,286) 90 (2,430+ *) M3RL 65 (1,857) 80 (2,286) 90 (2,430+ *) E3EB 50 (1,429) 70 (2,000) 80 (2,286) 90 (2,430+ *) B5BV-000K-B 50 (1,429) 65 (1,857) 90 (2,430+ *) B5BV-000K-C 70 (2,000) 90 (2,430+ *) * Manufactured homes with square footage greater than or equal to 2430 ft 2 should use a maximum 90 cfm rating per H.U.D. 3280.103(b)(1-6). Values in parentheses are maximum living space area in sq. ft. per H.U.D. 3280.103(b)(1-6). Furnaces are factory preset to HIGH blower speed for Whole-House Ventilation. 6

10. Attach ventilator cap assembly to roof. Press down firmly over caulking on flashing to ensure a waterproof seal. Secure roof cap flashing with appropriate fasteners for your specifi c roof construction. As an added protection against leaks, coat the ventilator flashing and fasteners with roofing compound. 11. Pull slack in fl exible duct down through ceiling hole to inlet fi tting, being careful not to damage or severely bend the duct. Trim off any excess length of duct to minimize restrictions. 12. Shape end of fl exible duct to fi t over collar on inlet fi tting and attach with clamp provided. 13. Install ceiling ring around flexible duct and attach to the ceiling. Note: Alternate ceiling ring(s) or other suitable materials may be used. 14. Be sure that the bottom of the attic ventilator sleeve is not blocked by roof installation. A minimum clearance of 1 1 /2 is needed below the sleeve to ensure proper airfl ow and a minimum clear space in the attic of 1 is recommended for good ventilation. Recommendations to Home Owner Moisture Control in the Home: Follow the recommendations of the manufacturer of your home to maintain low levels of moisture in your home. NORDYNE Recommendations: When moisture-producing activities (cooking, bathing, etc.) are occuring, operate exhaust fans. Avoid hanging clothes to dry within your manufactured home. Vent all fuel burning appliances. Avoid using humidifi ers. Avoid having large quantities of houseplants, pools of water, and other moistureproducing conditions. Place a vapor barrier (such as plastic sheeting) on top of the ground underneath your manufactured home. Ventilation openings should be provided in skirting. The fresh air supply to your home may be energized at any time by switching the furnace control (or the thermostat control, if so equipped) to VENTILATION. Periodically check that the unit is operating properly. Call for service if the unit is not functioning. 7

INSTALLER Do Not Discard These Instructions. After completing the installation, return these instructions to the Homeowner s Package for owner-user s future reference. Complies with H.U.D. Manufactured Home Construction & Safety Standards. 708574C 7085740 7085740 (Replaces 7078470) O Fallon, MO Specifi cations and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A. (03/06)