Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting



Similar documents
Data Sheet. Electro-mechanical counters Hengstler 800 series

Quick Connect. quick - simple - efficient.

Industrial Counting and Control Components

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Centro-Matic Automatic Lubrication Systems System Controls

Multifunction devices

Thyristor-controlled power supplies and battery chargers

Preset Counter signo 721

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Digital input modules

HERZ-Thermal Actuators

Electro-pneumatic control valves

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Frequency Converter Fv

ABB i-bus EIB Logic Module LM/S 1.1

Low and High Voltage Power Supplies

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

CONFIGURABLE SAFETY RELAYS

CONFIGURABLE SAFETY RELAYS

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

LCM Design Engineering SPECIFICATION FOR LCD MODULE TYPE ITEM NO.: MDLS MDLS16265-LV-G-LED04G (BB) (DOC. REVISION 1.0)

HYDRUS ULTRASONIC METER

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Short information Parameters are programmed via front-side membrane keypad

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

BATRON DOCUMENT NUMBER AND REVISION VL-FS-BTHQ 21605VSS-02 REV.A (BTHQ 21605VSS-FSTF-LED05W(1 DIE)) Feb/2002 BTHQ FSTF-LED WHITE 1/15

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Busch-Watchdog Presence EIB Type:

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

15 Series - Electronic step relay and dimmer. Features SERIE

Polyphase kwh Electricity Meter

AC3200 INTELLIGENT BROADBAND AMPLIFIER

Electronic Control Devices The European Product Catalogue 2007

MasterINTERFACE 39 Series - Relay interface modules

Product Information Sheet UH36 Hi Pot Tester

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Safety technique. Emergency stop module BO 5988 safemaster

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Duct Humidity Transmitter

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

3-phase, bidirectional energy meter

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Light scene push button 8gang comfort flush-mounted xx

Speed Control Relays SX2

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs

Adding Heart to Your Technology

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

FACTORY AUTOMATION EXPERTISE AND SERVICE OPEN DOORS RADAR SENSORS FROM PEPPERL+FUCHS

EFC Frequency converters

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Voltage Regulator SPAU 341 C. Product Guide

CNC-STEP. "LaserProbe4500" 3D laser scanning system Instruction manual

PC to TV Converter Box

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

*.ppt 11/2/ :48 PM 1

Technical data UNIBLOCK UBSF

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

BATRON. Specification for BTHQ 21605V-FSTF-I2C-COG

instabus KNX / EIB System System E F G H

FIREDEX Conventional Fire Panels

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Multi-Range Programmable DC Power Supplies 9115 Series

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

ABB i-bus KNX SA/S Switch Actuators Product Manual

PHOENIX CONTACT Features

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

User's Guide. Integrating Sound Level Datalogger. Model Introduction

DC Electronic Loads 8500 series

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Combi switchbox with integrated 3/2 way pilot valve

Operating and installation instructions. Professional plasma torch height control. Model: MyPlasm THC

Electronic Control Devices The European Product Catalogue 2007

MANTA Piston Distributor for Oil and Fluid Grease

ADM1TE 5/30A DIN rail single phase two wire energy meter

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Features, Benefits, and Operation

Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Expandable with a safe bus system

PD 100A. Printing data system

Transcription:

Adding Pneumatic Preset Counter Type 497 Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting VARIABLE PILOT SIGNAL Using two pneumatic preset counters it is possible to implement pilot signals with values ranging from 1 to 99.999. These counters are especially suitable as controlling elements for semi-automatic or fully automated processes. This applies both to varying preset/setting values and to values which remain the same for a long period. TECHNICAL DATA Display 3 or 5-digit indication of count and preset value, depending on version Digit height 4 mm Service pressure 2... 8 bar Air quality oilfree Filter pore width < 40 µm Operating temperature 0... + 60 C hose coupler M5 or rapid-fit connection (depending on version) Mounting front panel Mounting position horizontal roller axis Protection class (IEC 144) IP 40 with hoses connected; for higher degree or protection we recommend clear covers Count input adding Min. pulse length 8 ms Max. counting frequency 20 Hz Pulse duty factor 1:1 - manual with button - by external pneumatic signal, Min. pulse length 180 ms - automatic reset after preset has been reached (only in version with automatic reset) frequency max. 1 per 2 s Signal duration from when preset has been reached until reset; at 3 bar, counter with automatic reset 300... 340 ms Attention! Minimum time period between last count pulse and pneumatic reset is 50 ms.

Type 497 Technical data DIMENSIONED DRAWINGS with automatic reset

Technical data Type 497 CONNECTION DIAGRAMS Circuit diagram diagram Z Y P A E A V IG a b c Pulse input "count" Pulse input "reset" Air input Final output signal Output pilot signal Pulse generator Count Mains Pulse rate 3 pulses/s Pulse Duty Factor 1/10 20 pulses/s with non-pulse interval Output pulse Variable pilot signal Suggested connection : Rapid-fit connector ORDER INFORMATION Counter Button and pneum. with automatic reset reset 3-digit 5-digit 3-digit 5-digit Standard accessories Hose coupler M5 0 497 619 0 497 486 0 497 493 0 497 472 Rapid-fit connector 0 497 618 0 497 487 0 497 479 0 497 473

Type 497 Subtracting Pneumatic Preset Counter Integrated pneumatic reset 3 or 5-digit display Convenient button setting TECHNICAL DATA Display 3 or 5-digit count indication, depending on version Digit height 4 mm Service pressure 2... 8 bar Air quality oilfree Filter pore width < 40 µm Operating temperature 0... +60 C hose coupler M5 or rapid-fit connection (depending on version) Mounting front panel Mounting position horizontal roller axis Protection class (IEC 144) IP 40 with hoses connected; for higher degree or protection we recommend clear covers Count input subtracting Min. pulse length 8 ms Max. counting frequency 20 Hz Pulse duty factor 1:1 - manual with button - by external pneumatic signal, Min. pulse length 180 ms frequency max. 1 per 2 s Signal duration from when preset has been reached until reset; at 6 bar, counter with automatic reset 300... 340 ms (depending on connected volume and service pressure) Attention! Minimum time period between last count pulse and pneumatic reset is 50 ms. DIMENSIONED DRAWING

Technical data Type 497 CONNECTION DIAGRAMS Circuit diagram Pulse rate Z Pulse input "count" Y Pulse input "reset" P Air input A E Final output signal A V Output pilot signal IG a b c Pulse generator Count Mains Pulse rate 3 pulses/s Pulse Duty Factor 1/10 20 pulses/s with non-pulse interval Output pulse : Rapid-fit connector Order information Counter Standard accessories Button and pneum. reset 3-digit 5-digit Hose coupler M5 0 497 530 0 497 550 Rapid-fit connector 0 497 532 0 497 552 Transparent cover (description see "Accessories") with knob with lock Fittings M5 for hose M 5 x 1 1 405 613 1 405 614 3 641 733

Type 497 Pneumatic Preset Time Counter Preset value continuously visible Integrated pneumatic reset 3 or 5-digit display Convenient button setting FUNCTION DESCRIPTION 1 2 3 The combination of a pneumatic minutes or seconds pulse generator and a pneumatic preset counter allows setting of times from 1 to 99999 s or 1 to 99999 min. Versions with automatic reset permit fully automatic timing sequences. 1 = x-input 2 = seconds timer 3 = minutes timer TECHNICAL DATA Display 3 or 5-digit indication of count and preset value Digit height 4 mm Service pressure 2... 6 bar Air quality oilfree Filter pore width < 40 µm Operating temperature 0... + 60 C hose coupler M5 or rapid-fit connection Mounting with front panel Protection class (IEC 144) IP 40 with hoses connected; for higher degree of protection we recommend transparent covers Weight approx. 150 g, with automatic reset module approx. 200 g Count input adding Resolution 0.01 h, minute or second, dep. on version Max. counting frequency 20 Hz Time deviation max. 15 % in the first second or minute Frequency error 1/min. 0.5 %; 1/s 2 % - manual with button - by external pneumatic signal, min. pulse length 180 ms - automatic reset after preset has been reached (only in version with automatic reset) frequency max. 1 per 2 s Signal output Signal duration from when preset has been reached until reset; counter with automatic reset 300... 340 ms Switch A is ventilated with intake air during signal generation Signal generation transition P to A

Technical data Type 497 DIMENSIONED DRAWING CONNECTION DIAGRAM pneumatic timer Maße in mm pneumatic timer with automatic repeat mode X = air intake timing element Y = pneumatic reset P = air intake A = output signal ORDER INFORMATION Preset time counter Version Hose coupler M5 Rapid fit connection 3-digit, second indication 0 497 621 0 497 620 minute indication 0 497 622 5-digit, second indication 0 497 652 0 497 653 with automatic reset 0 497 665 0 497 663 5-digit, minute indication 0 497 654 0 497 655 with automatic reset 0 497 666 0 497 664 Standard accessories Transparent cover as described under "Accessories" with key with knob Fittings M5 for hose M5 x 1 1 405 614 1 405 613 3 641 733