Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580



Similar documents
3 IN 1 BATHROOM HEATER

Meaco 30L and Meaco 40L dehumidifier instruction manual

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

INFRARED QUARTZ WALL HEATER

IH E Sigma Island 90

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

Domestic AC Fans 230V Installation and Operating Guide. eco 230V AC Base Models: icon eco icon icon icon

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

1. Description. 2. List of Accessories included A B C F G H

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

4.3-inch Back-Up Camera

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Pre-site Installation Instructions for Aga Electric Cooker Models Electric C Electric E

Please also see 10 golden rules for correct Saniflo installation on

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Portable Air Conditioner

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Ducoterra Radiant Heating Panel Installation Manual

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Installation, operation and maintenance manual TX 35A

BLACK TIE. Instructions Manual

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

5W LED Energy Saver PIR Bulkhead

INSTALLATION & USER INSTRUCTIONS WALL MOUNTED LCD ELECTRIC FIRE

IMPORTANT SAFETY RULES TO FOLLOW

LUCCI AIRFUSION QUEST II CEILING FAN

Hot Water Urns. all models. Helpline. v3.0

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

INSTALLATION & USER INSTRUCTIONS

2KW CERAMIC HEATER DHCER20. User Manual

Electric Egg Boiler. Instruction Manual. Model Number: AEB-917

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

OPERATING INSTRUCTIONS

15GAL STEEL OIL DRAIN WITH 110V PUMP

Achat 115MA full-range speaker. user manual

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

100 Series Maxi Internal Filters. Instruction Manual

ALI BABA PIANTANA (H165) design SLIDE Studio

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

San josé OWNER S MANUAL

Infrarot-Bewegungsmelder IP44

Cooktop Low-Profile Ventilation Hoods

Operating instructions. SCORP 220 Plus SCORP 360. Pipe Cutter. Code Machine-no.:

Atlanta CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. IF UNSURE CONSULT A QUALIFIED ELECTRICIAN

Curved Quadrant Instruction Manual

2-SLICE COOL TOUCH TOASTER

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

CUBO 20 HANGING design SLIDE Studio

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Installation & Maintenance Instructions

Important Information

PIVOT GLOBO design SLIDE Studio

WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide

Fire Protection Notice No. 9 ELECTRICAL SAFETY

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) (ROI) White series

Chill 4 Hole Bath Shower Mixer

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Use and Care Manual. Model CPA12KH AIR CONDITIONER

1/2 GLOBO 40 design SLIDE Studio

ELECTRIC INSTANTANEOUS WATER HEATER

CELO5. User & Installation Manual.

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

User s Manual Before using the inverter, you need to read and save the safety instructions.

Instruction Manual. Window Wiper AFW900. (Read carefully before use)

IMPORTANT INFORMATION

Acclaim III Recessed Fluorescent Luminaires ATEX

GLOBO 30 HANGING design SLIDE Studio

GLOBO 30 design SLIDE Studio

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

2400W PIR LIGHT C O N T R O L L E R Cat No. SLW2400

CUBO 20 design SLIDE Studio

Installation and safety instructions for AC/DC built-in devices

Baxi Combi 80e & 105e

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

PG_IM_A.indd 1 23/06/ :22

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

VACUUM CLEANER INSTRUCTION MANUAL

V94 BULK TAPE DEGAUSSER

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

Installation Instructions ERV/PRV Downdraft Vent

Wetroom Panel (Concealed Fix)

EVOKE LCD ELECTRIC WALL HEATER MODEL : L23LCD INSTALLATION AND USER INSTRUCTIONS

Transcription:

Any Queries Call : 08000 23 23 23 Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590 Rapide Inline Ceiling Extractor Fan, White Fascia Illuminated 41800040670 Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580 Rapide Inline Ceiling Extractor Fan, Chrome Fascia Illuminated 41800040660 Fixing Instructions Thank you for purchasing this Bathstore product. Please read through these instructions carefully and refer back to them during installation to ensure that your product is fitted safely and that it retains its high quality finish. Please retain this leaflet for future reference. Before drilling, ensure there are no hidden cables or pipes in the wall These products are suitable for installation in zones: 2 & Outside Zones Please see Figure 1 on the back page for details Ver No. 2.0 May 2015

In The Box Includes: 1. Fascia 2. LED Driver (41800040670 & 41800040660 only) 3. High powered Inline fan, 4. 3 metre flexible ducting 5. White external fixed grille 6. Four galvanized steel hose clamps 7. Screw and dowels 8. Plastic screwdriver (only for modifications with timer) 9. Fixing instructions Warning The Rapide Inline Fan 41800040670 & 41800040660 is supplied with an MR16 3 Watt LED lamp. This is the only lamp suitable for use with this fan. Do not replace with any other lamp as this will invalidate any warranty. Do not exceed the stated wattage. The fan must be connected to power mains through an automatic circuit breaker integrated into the fixed wiring system with the gap between the breaker contacts on all poles not less than 3mm. Check the fan for any visible damages of the impeller and the casing before starting installation. The casing internals must be free of any foreign objects which can damage the impeller blades. Misuse of the product or any unauthorized modification is not allowed. Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room through open chimney flues or other fire-protection devices. Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting. Please Note; The fan may operate immediately when connected, this is normal and due to a residual charge left in the capacitor during testing. Should this occur, switch off, adjust timer to desired setting then turn back on. (see page 7 for Timer System) 2

Any Queries Call : 08000 23 23 23 Mounting 1. Ceiling mounted ventilation should be ducted through the roof space, by ducting to an external soffit under the eaves or grille in the slope of your roof. NB: Ducting installed between a floor and ceiling can only run between joists, not across them. 2. Mark the position of the vent fascia with a pencil in a suitable position on the ceiling, making sure that it is between the joists. 3. Drill a 9mm hole through the ceiling anywhere along the edge of the pencil line. Now cut out the hole with a pad saw. 4. Hold the vent fascia against the ceiling and mark the position of the fixing holes. Fix the unit in place using suitable heavy duty plasterboard fixings (not supplied). 5. Attach flexible ducting with the metal hose clamps. Ensure that the ducting has a smooth flow towards the motor body to minimise air resistance. Follow a similar procedure for the outside wall grille. Extra ducting may be used to extend the distance to the external grille but performance will be reduced. 6. Install the Rapide Inline fan within the loft or ceiling space (ensuring correct direction of air flow using arrows on the fan). The fan is suitable both for horizontal on a wall (fig. A) or a floor (fig. B). When mounting the fan ensure there is a minimum of 1m straight ducting to the motor body (see fig.b). Attach the flexible ducting to the fascia with the metal clamps supplied. min 1m fig. A horizontal on a wall fig. B horizontal on a floor Do not mount vertically 3

7. Place motor in desired location and mark fixing holes. 8. Fix motor to desired surface, using suitable wall plugs if necessary. 9. Connect the flexible ducting to both sides of the Inline fan with the metal hose clamps. Ensure there is a minimum of 1m straight ducting between fascia and fan. Electrical Connection 10. Ensure the mains power supply to which the fan is being connected is turned off. This product is designed to be connected to an on/off switch outside the bathroom, or to a ceiling mounted pull cord switch. 4

Any Queries Call : 08000 23 23 23 11. Using a screw driver, remove cover. 12. Using a screw driver, remove cable grip. Feed cable through hole & replace grip. 13. Wire the fan as per the diagram below. N ~ L QF ST N LT L QF - Circult Breaker ST - External Switch (e.g. light switch) 14. Replace cover using a suitable screw driver. 15. On Illuminated versions (41800040670 & 41800040660) the mains supply from the bathroom fitting should be connected to the LED driver as per the wiring diagram for lamp. 16. Fix the external grille to the soffit in the same way as the ceiling fascia with 4 screws. Wiring Diagram For Lamp (41800040670 & 41800040660 only) Live supply is Red or Brown Neutral supply is Blue or Black Live is Red Neutral is Black AC in DC out 5

Operation The fan is rated for connection to single-phase AC220-240 V / 50/60 Hz power mains. The fan is designed for continuous operation always connected to mains power. Air motion direction in the system must match the pointer on the fan casing. Ingress protection rating IPX4. Maintenance Fan maintenance is to be performed only after the fan is disconnected from the mains power suppy. Maintenance means periodic cleaning of the surface of dust and dirt. All surfaces should be cleaned with diluted detergent, i.e. washing up liquid, and a soft cloth. Scourers and scouring agents should not be used, as these may cause damage to the surface of the product. Avoid water dripping on the electric components. Wipe the surfaces dry after cleaning. Waste Electrical & Electronic Equipment Regulations (WEEE) Requires that any of our products showing this mark (left) must not be disposed of with other household or commercial waste. Bathstore does not levy any WEEE disposal charges to its customers for affected WEEE related products. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate any such product from other waste types and recycle it responsibly at your local facilities. Check with your Local Authority, Recycling Center or retailer for recycling advice. 6

Any Queries Call : 08000 23 23 23 Timer System The fan is operational after the control voltage is supplied by the external switch (e.g., by the light switch) to the input terminal LT. After the fan is switched off the fan continues to operate within the timer period set by the timer from 2 to 30 minutes. To adjust the run on timer, rotate the control knob clockwise to increase and anti-clockwise to decrease the off-delay time respectively (see below diagram). Please note the adjustment should only be done without the fan running. Warning! The timer circuit is under mains voltage. Ensure mains power supply is switched off before making any adjustments. The set includes a specially designed plastic screwdriver for timer setting adjustments. Only use the plastic screwdriver to alter the turn-off delay time. Do not use a screwdriver, knife, etc. for adjustments so as not to damage the circuit board. 7

60CM 60CM zone 2 zone 2 zone 1 zone 2 225cm 60CM radius These products are suitable for installation in zones: 2 & Outside Zones All installations must comply with guidelines which are based on a zonal concept. The diagram above illustrates this concept and must be followed to ensure the safe installation of electrical appliances in the bathroom. These regulations apply to domestic installations only. Installations must be made in accordance with the current IEE wiring regulations and relevant building regulations. Bathstore recommends that all electrical bathroom products should only be fitted by a suitably qualified, Part P registered electrician. Technical Information Power Input: 220-240V, 50/60Hz Maximum Ventilation Volume: 137 m3/hr (±5%) / 38.056 Litres Per Second Power Consumption: 16W (+3W for lamp on illuminated versions) Decibel: 37dB Dimensions: Ø14 x D7.3cm Electrical Safety Information Bathstore recommends that all electrical bathroom products should only be fitted by a suitably qualified, Part P registered electrician in accordance with current IEE reguations. Ensure mains power supply is switched off before starting installation. Before drilling, ensure there are no hidden cables or pipes in the wall. Care Instructions Do not use abrasives or solvents when cleaning this product. Wipe off all water spillages as soon as possible using a soft, damp cloth. Guarantee This product is guaranteed in the UK for a period of 2 years from the date of purchase. The guarantee is invalid in the case of improper use, installation or tampering. Should this product fail during the guarantee period it will be replaced free of charge, subject to correct installation and return of the faulty unit. Bathstore does not accept responsibility for any installation costs associated with the replacement of this product. Your statutory rights are not affected. Bathstore reserve the right to alter specifications without prior notice. Any Queries Call : 08000 23 23 23