Philips HD7. Detailed ultrasound system specifications and transducer guide



Similar documents
Reliable versatility. Philips HD5 ultrasound system

performance ultrasound to the whole picture

Contents. HD11 XE Quick Guide

Improve your image. ClearVue 350 ultrasound system. The print quality of this copy is not an accurate representation of the original.

Improve your image. ClearVue 650 ultrasound system

Philips CX50 CompactXtreme System. A New Class of Compact Echocardiography

Ultrasound. Your versatile performer to depend on. Philips ClearVue ultrasound family for women s health care

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

Choose versatility. Philips HD11 XE ultrasound system

Vivid S6. Cardiovascular ultrasound system. imagination at work. GE Healthcare

SAMSUNG ULTRASOUND RS80A

Philips PageWriter Touch ECG System

B E S T - I N - C L A S S C O M P A C T M U L T I - P U R P O S E U L T R A S O U N D

GE Healthcare VOLUSON 730 PRO The Diamond Release

Premium performance compact ultrasound. Philips CX50 CompactXtreme ultrasound system

Company profile. Quote from the analyst of. Company Milestone. Feel the Difference. Tel: Fax:

Samsung Ultrasound H60

Not just a new ultrasound, a new vision. Philips VISIQ ultrasound

3200L 32" Interactive Digital Signage Touch Display

The ultrasound system that sets new standards

GE Healthcare. Vivid 7 Dimension Cardiovascular Ultrasound System

Leading the New Standards

Dash 18X / Dash 18 Data Acquisition Recorder

Davis Medical Electronics

A new way of thinking. Philips Sparq regional anesthesia and pain medicine ultrasound system

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay

Hunting Bats. Diagnostic Ultrasound. Ultrasound Real-time modality

More than a Portable System

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

Video Communication System PCS-1 PCS-1P

PT-LB55NT S P E C F I L E. Micro-Portable Wireless LCD Projector. As of February Specifications subject to change without notice.

Dash 8Xe / Dash 8X Data Acquisition Recorder

. ImagePRO. ImagePRO-SDI. ImagePRO-HD. ImagePRO TM. Multi-format image processor line

PRODUCT NO.: PT-P1SD PRODUCT NAME: Digital SD Slide Projector

CONSOLES R E G I A S E R I E S LIGHTING

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH

Gear View Basic. User Help. Version Written by: Product Documentation and R&D Date: August 2015 LX-DOC-GVB UH-EN-REVA

Twelve. Figure 12.1: 3D Curved MPR Viewer Window

Ny teknologi: Fagdagene ved St. Olavs Hospital Lasse Løvstakken Dept. Circulation and Medical Imaging

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

UGEO H60 PERFORMANCE IN STYLE

DynaGuard 200 Series. Compact and Versatile MPEG-4. Ver. 1.1

WXGA (1280 x 800), 3500 lumens, up to 7,000 hours lamp, HDMI, throw ratio, wireless ViewSync

HP rack and power infrastructure products are designed and developed to be used specifically with HP servers and storage.

AXIS 262+ Network Video Recorder

Easy Installation All five standard monitors fit into shallow mounting areas, requiring about 3" of depth. The XT1502, SXT1811, and SXT2011 models hav

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

M-Turbo Ultrasound System. User Guide

3D Viewer. user's manual _2

User Manual V1.0. Remote Software

K Service Source. Video Conferencing. QuickTime Conferencing Kit, QuickTime Conferencing ISDN Kit

A new era in premium vascular ultrasound. Philips EPIQ 5 ultrasound system

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

NEW PRODUCT ANNOUCEMENT

July 23, Dear Mr. Kim:

VPL-DX15 VPL-DX11 VPL-DX10. Powerful Tabletop Projectors

Specifier Notes: This guide specification incorporates CSI MasterFormat TM 2004 Edition Numbers and Titles.

Comparison SMART Board Interactive Whiteboard Systems. Models SB600i2, SB600i3 and SB685ix

SMART Board interactive whiteboard system projectors

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

DC Electronic Loads 8500 series

HD141X. Super-sized home entertainment. Bright vivid colours 3000 ANSI Lumens. Full HD 1080p image quality

EV-1000 Series DVR. Quick Operation Guide. Version 1.0.0

Inspiron Series. Views. Specifications

Networked versatility. IntelliVue MP60 and MP70 patient monitors

Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform

4 Port full HD multiviewer real-time USB/KVM switch

CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version

When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.

VET /2016-E TELE PACK VET X LED. The Complete Mobile Endoscopic Video and Documentation System

DR Retrofit Kit 1417 WL Configuration Integrated PACS

Quick user guide for the Vista Quantum 960H range of DVRs, models included

SNC-VL10P Video Network Camera

Lenovo ThinkVision L197 Widescreen LCD Monitor View your images on a wide screen

How To Use A High Definition Oscilloscope

HP ProDisplay P17A LED Backlit Monitor. User Guide

(1.07 inches to 1.37 inches) 376 mm (14.80 inches) 259 mm (10.20 inches)

VPL-E200 Series Data Projectors VPL-EW276 VPL-EW246 VPL-EX276 VPL-EX246

Data Sheet FUJITSU Display L27T-1 LED

43 Full HD Direct-lit LED Commercial Display

Network Camera SNC-P1

GOOD WILL Instrument Co., Ltd. All rights reserved.

HP Compaq LA1905wl, LA1905wg, LA2205wg, LA2205wl, LA22f, LA2405wg, and LA2405x LCD Monitors. User Guide

AVR 158. Audio/video receiver. Quick-Start Guide ENGLISH

S300. Big Screen Viewing. Bright projection 2800 ANSI Lumens. SVGA resolution, 15,000:1 contrast ratio. Low ownership costs - up to 6500 hrs lamp life

Venue 50 Ultrasound. GE Healthcare. Product Description. The Venue TM 50 is a high-performance tablet ultrasound system

VPL-SW631. 3,300 lumens WXGA Ultra Short Throw projector. Overview

Wahl C50 Calibrator FEATURES

Inspiron Series. Views. Specifications

Views. Specifications

SMART Board interactive whiteboard system Model 680iv

aseries DVR04/DVR08 DIGITAL VIDEO RECORDER Quick Operations Guide

How To Use The Dc350 Document Camera

Compactly Powerful. Ultrasound System UGEO PT60A CT-UGEO PT60A-CWW-CMI-0705-EN

Transcription:

Philips HD7 Detailed ultrasound system specifications and transducer guide The Philips HD7 provides you with a rich combination of advanced performance, efficient workflow and elegant data management, all at a very achievable price point. It features design architecture unprecedented in the evolution of ultrasound. From the ground up and inside out, the HD7 system is built to make your work easier, more efficient and more productive. Its flexible platform also enables you to configure a HD7 to meet your exact requirements for price, performance and clinical application. Applications Abdominal Small parts and superficial Pediatric Musculoskeletal Neonatal Urology Obstetrical Gynecological and fertility Prostate Vascular Cerebrovascular Peripheral vascular Intraoperative vascular Transcranial Doppler Cardiac Adult Pediatric Stress Imaging modes Philips Microfine 2D focusing Philips Color Power Angio (CPA) Directional Color Power Angio M-mode Anatomical M-mode Color M-mode Pulsed Wave Doppler Continuous Wave Doppler 3D Color compare mode Dual mode Duplex for simultaneous 2D and Doppler Triplex mode for simultaneous 2D, Doppler, and color or CPA 2D Optimization Signal Processing Tissue Harmonic Imaging (THI) Intelligent Doppler Reconstructed zoom with pan (read zoom) Philips high-definition zoom (write zoom) Panoramic Trapezoidal Pulse Inversion Harmonic Contrast Adaptive Doppler Adaptive Color Doppler Color Tissue Doppler Pulsed Wave Tissue Doppler

System Specifications Control panel and user interface Easy-to-learn graphical user interface Primary controls readily accessible and logically grouped Commonly used secondary controls located on soft keys for quick access; soft key functions change dynamically based on the currently active mode, preset or system function Other secondary controls accessible through on-screen menus Alphanumeric keyboard: QWERTY keyboard with globalization key for conversion to local language (English, French, German, Italian and Spanish) User selectable keyboard input language (Roman, Japanese, Simplified Chinese, Russian and Portuguese) Trackball with Select and Enter keys for easy system navigation Integrated stereo speakers Imaging mode keys: 2D, Color Power Angio imaging, M-mode, Color Doppler, Continuous Wave Doppler (CW), Pulsed Wave Doppler (PW) 2D image controls: Depth, Dual Left, Dual Right, Freeze, THI, and Zoom Focus Image enhancement controls: Dynamic Range, Focus, Gain, Persistence, Post-processing Map, and Smooth Patient specific optimization keys: 2D Opt, Transducer (transducer select), and THI Quantitative controls: Caliper, Calc, Erase, Trackball Doppler or color controls: Angle and Steer, Spectral, Scale, Baseline, Gain, Power, Volume, Duplex, and Triplex Image Acquisition keys: Review, Report, VCR, Acquire, and two print keys supporting external print and video options Annotation controls: Text, Erase, Arrow, and Bodymarker Function keys: Microphone, Patient, Preset, and Setup Four option keys activated with additionally purchased features such as 3D, stress echo, panoramic, and Tissue Doppler imaging Online Help key Lateral Gain Compensation (LGC) slide pot controls Time Gain Compensation (TGC) slide pot controls Review and Report keys Gray shades 256 (8 bits) in 2D, M-mode and Doppler spectral analysis Acquisition frame rate Greater than 230 frames per second in High Frame Rate mode (dependent on transducer, field of view, depth and angle) Ergonomic, user-centered design High mobility cart Designed for easy maneuverability Front handles for portability Four-wheel swivel ability Two-wheel swivel lock and brake Lightweight aluminum frame Control panel can be raised, lowered and rotated more than 300 Supports comfortable operation from standing and sitting positions Improves accessibility of controls and reduces extended reaching 15-inch (333 x 263 mm) high-resolution color monitor Raises, lowers and rotates with control panel Independent tilt (+15/-10 degrees) and swivel (+/- 120 degrees) XGA resolution (1024 x 768) 60 Hz, non-interlaced RGB The system output is SVGA (800 x 600) 60Hz non-interlaced RGB 0.297 mm dot pitch Brightness control, Automatic Backlight Stability (BLS) control (BLS ensures quick warm-up and consistent light output over operational life.) Super In-Plane Switching(SI-PS) panel for superior viewing angle and grayscale reproduction iscan Intelligent Optimization helps reduce repetitive key strokes during exams Palm rest Back deck provides easy access to hardcopy and documentation devices Built-in A/C line conditioner provides isolation from voltage fluctuation and electrical noise interference Internal high-capacity impeller fans with automatic speed adjustment to optimize cooling efficiency with minimal audible noise

System architecture All-digital broadband beamformer Microfine 2D focusing with Dynamic Focal Tuning 232 db full time input dynamic range 1,024 digitally-processed channels Continuously variable steering in 2D, color and Doppler modes 2D Opt signal processing with 2X multi-line parallel processing and frequency compounding: Improves tissue contrast resolution and textural perception Sharpens lateral beam profile for finer dot size Reduces speckle artifacts for increased image clarity 2D Opt key with up to five settings for patient-specific optimization in 2D and color Doppler iscan one-touch Intelligent Optimization In 2D vascular, Ob/Gyn, and general imaging, one-button automatic adjustment of: - TGC and Receiver Gain to achieve optimal uniformity and brightness of tissues in most exams - Compression curve based on range of detectable tissues iscan Doppler One-touch optimization of spectral tracing to improve productivity Display annotation On-screen display of all pertinent imaging parameters for complete documentation, including: transducer type and frequency range, active clinical options and optimized presets, display depth, TGC curve, grayscale, color map, frame rate, dynamic range, compression and contrast enhancement, color gain, color image mode, and hospital and patient demographic data Displayed data can be turned off for generating images used in publication and presentation Sector width and steering markers 2D Opt setting and iscan icons Real-time display of Mechanical Index (MI) Real-time display of Thermal Index (TIb, TIc, TIs) Quick text allows easy annotation at any time during an exam Text places, moves, erases, modifies or appends predefined text labels, typed text and arrows Body markers displays body-part icons appropriate for the active preset and indicates relative transducer position Icons selectable via trackball scroll and soft keys Dual orientation marker to indicate the active buffer for twobuffer dual display VCR indicator allows user to know when VCR is recording Annotation erased with start of new study Image presentation Up or down Left or right Multiple duplex image formats (1/3-2/3, 1/2-1/2, 2/3-1/3) Depth to 30 cm (exam and transducer specific) Transducers Transducer selection Electronic switching of up to four imaging transducers Dedicated (Pedoff) connector available for non-imaging CW and PW transducers System supports up to 11 transducers to meet a wide range of clinical needs Multiple user-selectable transmit focal zones; up to eight focal zones on selected transducers Continuous dynamic receive focusing on all transducers S4-2 Broadband Sector 4 to 2 MHz extended operating frequency range High-resolution imaging for abdominal, cardiac, and Ob/Gyn applications Supports 2D, color, PW and CW Doppler, Tissue Harmonic Imaging, Color Power Angio imaging, and contrast Biopsy kit available s8 Broadband Sector 8 to 3 MHz extended operating frequency range High-resolution imaging for pediatric, cardiac, abdominal and Ob/Gyn applications Supports 2D, color, PW and CW Doppler, and Color Power Angio imaging

System Specifications Transducers continued C5-2 Broadband Curved 5 to 2 MHz extended operating frequency range High-resolution imaging for abdominal and Ob/Gyn applications Supports 2D, color, PW Doppler, Tissue Harmonic Imaging, Color Power Angio imaging, and contrast Multi-angle biopsy kit available L12-3 Broadband Linear 12 to 3 MHz extended operating frequency range 15 of trapezoidal imaging High-resolution imaging for superficial applications including vascular, small parts, and musculoskeletal Supports 2D, color, Tissue Harmonic Imaging, PW Doppler, and Color Power Angio imaging C6-3 Broadband Curved 6 to 3 MHz extended operating frequency range Provides high-resolution imaging for abdominal and Ob/Gyn applications Narrow footprint for improved intercostal access Supports 2D, color, PW Doppler, Tissue Harmonic Imaging and Color Power Angio imaging Multi-angle biopsy kit available L12-5 50 mm Broadband Linear Fine pitch, 256 element, high-resolution linear array 12 to 5 MHz extended operating frequency range Supports 2D, color, PW Doppler, and Color Power Angio imaging Trapezoidal imaging High-resolution superficial applications including small parts, breast, and musculoskeletal imaging Biopsy kit available C8-5 Broadband Curved 8 to 5 MHz extended operating frequency range High-resolution imaging for abdominal, abdominal-vascular and Ob/Gyn applications 90 field of view Supports 2D, color, PW Doppler, and Color Power Angio imaging Biopsy kit available C8-4v Broadband Curved Array 8 to 4 MHz extended operating frequency range End-fire sector, 11 mm radius of curvature, 135 field of view Supports 2D, color, PW Doppler, and Color Power Angio imaging Endovaginal applications Biopsy kit available E6509 Broadband Curved 7.5 to 5 MHz extended operating frequency range High-resolution endocavitary imaging for Ob/Gyn and prostate applications Supports 2D, color, PW Doppler, and Color Power Angio imaging Biopsy kit available 15-6L Broadband Compact Linear 15 to 6 MHz extended operating frequency range 8 of trapezoidal imaging High-resolution imaging for intraoperative vascular applications Supports 2D, color, PW Doppler, and Color Power Angio imaging D5009V Cardiac and Vascular Non-imaging 5.0 MHz, 9 mm diameter pencil transducer Non-imaging PW andcw Doppler for cardiac and vascular applications Imaging modes 2D Mode Microfine 2D Focusing Frame rate selection Eight-level digital reconstructed zoom with pan Variable level high-definition zoom Image orientation marker Cineloop image review (up to 1,000 B/W frames) Persistence, adjustable in real time and Cineloop review Selectable compression curves Sector size and steering control Selectable line density Up to eight transmit focal zones plus separation control Dual imaging (single and two buffer) Philips Chroma imaging with multiple color maps

M-mode Available with all imaging transducers Selectable sweeping rates Time markers: 0.1 and 0.2 seconds Chroma colorization with multiple color maps M-mode review for retrospective analysis of M-mode data Full-screen M-mode display facilitates diagnoses by enabling easier, more accurate caliper placement Color M-mode on all sector transducers and C5-2, C8-4v, transducers Anatomical M-mode Uses 2D image as a basis for M-mode analysis at a defined line, independent of transducer orientation Makes it easier to keep the M-mode line perpendicular to the anatomy, even in abnormally shaped or positioned hearts Provides data on direction, position and timing of any single echo received from any point of the tissue for M-mode analysis in any direction, for examining cardiac chamber diameters, LV regional wall motion and location of accessory pathways Anatomical M-mode trace can be generated or modified post Freeze Anatomical M-mode on all sector transducers, including S4-2, s8 Doppler Display annotation including Doppler mode, scale (cm/sec or khz), pulse repetition frequency, wall filter setting, gain, acoustic output status, sample volume size, normal or inverted, angle correction, grayscale curve Adaptive Doppler to boost weak signals to improve spectrum visibility and enhances pulsed-wave audio signals for precise flow assessment* Intelligent Doppler imaging automatically maintains optimal angleto-flow to assist in delivering accurate and consistent Doppler velocity measurements (available with vascular and general imaging application packages on linear transducers only) Adjustable frequency and velocity display ranges Eight-position zero baseline shift Normal and invert display around horizontal zero line Selectable sweep speeds Selectable grayscale curve for optimal display Selectable display format (1/3-2/3, 1/2-1/2, 2/3-1/3) Full-screen Doppler display which improves diagnoses by enabling easier, more accurate caliper placement Doppler review for retrospective analysis of Doppler data Pulsed Wave (PW) Doppler Available on all imaging transducers Adjustable sample volume size:.05-2.63 cm Displays tissue movement and blood flow in 2D and PW Doppler simultaneously Triplex mode displays tissue movement and blood flow in 2D, color or CPA and PW Doppler simultaneously Continuous Wave (CW) Doppler Available on cardiac sector transducers only Steerable through 90º Maximum velocity range: 19 m/sec Color Doppler Adaptive Color automatically optimizes color or Color Power Angio frequencies, ensuring excellent sensitivity and color penetration* Color compare simultaneously displays real-time Color Power Angio, color Doppler and grayscale images side-by-side Automatic color invert automatically inverts color maps to maintain selected color coding when the linear steering angle passes through vertical Available on all imaging transducers Cineloop review Chroma 2D colorization with multiple color maps 256 color bins Continuously variable color steering Trackball-controlled color region of interest: size and position Maps, filters, color sensitivity, line density, smoothing, echo write priority, color persistence, gain and baseline optimized automatically by preset or is user selectable Velocity and variance displays Color and2d line density control Selection of color bar display units

System Specifications Contrast Imaging System optimized for detecting harmonic agent signatures Variable low Mechanical Index (MI) and flash modes Pulse Inversion Harmonic imaging on the S4-2 transducer for cardiac and abdominal applications and the C5-2 transducer for general abdominal applications Start and Stop timer 3D Grayscale Imaging Available with Ob/Gyn application Provides a qualitative volume display of 2D data set Available on all imaging transducers Individual controls for manipulating the on-screen 3D rendering and display options Tissue Harmonic Imaging (THI) System processing of second harmonic frequencies (nonlinear energy) in tissue Extends high performance imaging capabilities to all patient body types Available on the S4-2, C5-2, and L12-3 transducers Image display virtually free of artifacts Pulse inversion mode Expanded Field of View Panoramic imaging Ability to perform point-to-point distance measurement Extended field of view composite imaging Full zoom, pan, Cineloop review and image rotation capabilities Trapezoidal imaging Expands field of view on linear array transducers up to 15 on each side in vascular and general imaging applications Color Power Angio Imaging (CPA) Highly sensitive mode for small vessel visualization Available on all imaging transducers Fully user-configurable Cineloop review User-definable presets Multiple maps including directional CPA Directional CPA Individual controls for gain, filters, sensitivity, echo write priority and color invert Adjustable CPA region of interest: size and position User-selectable persistence User-selectable blend levels TGC control Write priority Tissue Doppler Imaging (TDI) Color TDI uses color to display direction and timing of myocardial function Pulsed wave Tissue Doppler Imaging (TDI) for velocity mapping of cardiac tissue and vessel wall motion Available on all sector transducers Simultaneous or duplex mode of operation in conjunction with 2D, color Doppler and color TDI Stress Echo Fully-integrated stress echo module Three fixed protocols User-defined protocols Stop and resume a protocol Re-label, add or remove stages or views during a protocol Up to eight-stage capture-and-study protocols Single, quad and multi-cycle acquisition Gain Save LVO with stress Wall motion scoring and reporting Measurements and analysis Measurement tools and general description 2D distance 2D circumference or area by ellipse, continuous trace, trace by points 2D curved-linear distance M-mode distance (depth, time, slope) Manual Doppler distance Manual Doppler trace Automatic Doppler trace races frozen spectral display to calculate and display user-selected measurements in most presets Philips High Q Automatic Doppler Analysis

Time and slope measurements in Doppler and M-mode Ao dec time MV dec time PA dec time PA acc time Doppler values containing PI, RI, S/D indices 2D volume Heart rate Trackball-controlled electronic measurement calipers: eight sets User-defined protocols, measurements and equations On-the-fly measurement labels Fully-editable results data sheet Integrated patient exam report Moveable results box can be moved to any corner of the screen User-defined measurements User-defined calculations User-defined fetal growth tables Clinical Option Analysis packages Comprehensive measurements, calculations and applicationspecific reports with imbedded images, including expanded cardiac, vascular, Ob/Gyn and general imaging capabilities for thorough exam documentation Cardiac analysis Volume by area or length method M-mode analysis Peak and mean gradients Pressure half time Continuity equation Diastolic function Cardiac output Qp:Qs ratio Pulmonary vein analysis Valvular analysis - Proximal Isovelocity Surface Area (PISA) - E/A ratio Ventricle analysis - Ejection fraction (via Teichholz or cubed method) - Simpson s biplane and single plane - LV mass - IVRT Vascular analysis Abdominal vascular Cerebrovascular Transcranial vasculature protocols Right and left, lower and upper extremity protocols Optional tools: percent diameter area reduction Automated finding codes and user comments Ob/Gyn and fertility analysis Fetal biometry Biophysical profile Amniotic fluid index Early gestation Fetal long bones Fetal cranium Nuchal thickness Other OB measurements: - 2D echo - Fetal heart M-mode - Fetal Doppler - Echo Doppler - User-defined fetal growth tables OB calculations and tables are user-definable OB trending data for up to ten studies per patient Gynecology andfertility - Uterus - Right and left ovary - Right and left follicles General Imaging analysis General abdominal Small parts Pediatric general Musculoskeletal High Q Automatic Doppler analysis Automatic real-time and retrospective tracing of: Instantaneous peak velocity (or frequency) Instantaneous intensity weighted mean velocity (or frequency) User configurable display of values Adjustable goal posts to within a single heart cycle, allowing quantification of any portion of the cycle (e.g., systole only)

System Specifications High Q Automatic Doppler analysis continued Vascular Automatic real-time display of: - Time-averaged mean velocity (or frequency) - Resistive index - Pulsatility index - Systolic/diastolic ratio and diastolic/systolic ratio - Acceleration/deceleration times Cardiology Automatic real-time display of: - Peak velocity - Peak gradient Display of: - Cardiac output - VTI - Mean velocity - Mean gradient QLAB analysis Optional off-line software facilitating advanced quantification for ultrasound Region of Interest (ROI) quantification Image data content analysis Contrast intensity analysis Grayscale, Power/Angio Color Doppler velocity analysis Draw up to 10 ROIs Calculate Mean, Median, and Standard Deviation of intensity per frame Graphical display of time vs. Intensity data Curve-fit graphical data Compare images and ROIs Automated measurment of Intima Media Thickness (IMT) Automatic assessment of the IMT or user selected frame Intended for carotid and other superficial arteries Cineloop review Acquisition, storage in memory, and display in real-time and duplex modes of up to 1,000 frames (four minutes in Quick Review) of 2D and color images for retrospective review and image selection Single frames of Doppler data and M-mode images can be archived to print or electronic media Supports two-buffer Dual Imaging mode of up to 500 frames per buffer Trackball control of frame-by-frame image selection Variable playback speed Trim capability Functions in 2D and Tissue Harmonic Imaging, M-mode, PW Doppler, CW Doppler, Color Doppler, Color Power Angio imaging, Tissue Doppler Imaging, and Contrast Imaging modes ECG andphysio One three-lead ECG input One external ECG input Two physio input channels (1V, p-p) Selectable ECG triggered skipping between 1 and 20 Miscellaneous system data Footswitch Three pedals Allows Freeze, Acquire and Enter in stress Includes two user-definable record functions Connectivity 2 USB ports 80 GB hard drive space Standard CD-R/RW Direct digital storage of system configuration backup, including user-defined presets and OB trending data, to USB or CD Direct digital storage of single frame color and B/W images to internal hard disk, USB flash and compact disk Direct digital storage of B/W and color loops to internal hard disk, USB flash and compact disk Stores a minimum of 150,000 B/W still frame images to internal hard drive Integrated multi-session CD allows storage of multiple individual studies to a single CD at different times rather than requiring single batch mode storage 700 MB compact disk stores a minimum of 528 B/W still frame images (RGB uncompressed format), or 1,570 B/W still frame images (palette color uncompressed format) or 8,440 B/W still frame images (YBR JPEG compressed format at typical 16:1 compression ratio) Ability to export AVI clips and BMP images to USB flash for PC viewing

Fully-integrated interface Extensive image management capability, including thumbnail image review, Cineloop editing, and user-configurable patient reporting Study manager allows user to digitally acquire, review and edit complete patient studies Exam directory Delete and replace recalled image capability Multiple study archive formats (palette color, RGB, YBR) DICOM 3.0 print and store service class user Multiple DICOM servers Multiple DICOM presets DICOM structured reporting for cardiac and Ob/Gyn Configurable print User may select images to print from all acquired images 10BaseT or 100BaseT Ethernet output Site configurable IP address, port and AE title Modality Performed Procedure Step (Mpps) Modality Worklist Works in conjunction with radiology and cardiology information systems Automatic entry of patient demographics Study reports available as DICOM images System can use lossy JPG image format with user configurable compression ratio Physical dimensions Depth: 40.3 in/102.4 cm Height (adjustable): 51.8-58.4 in/131.5 148.3 cm Control panel height (adjustable): 32.3-38.8 in/82-98.6 cm Width: 21.6 in/55 cm Weight: 165 lbs /75kg (no peripherals) Adjustable control panel and monitor (height and swivel) USB flash port Integrated multi-session CD drive iscan Intelligent Optimization hard key 2D Opt hard key Four transducer ports Integrated footrest Four-way swivel wheels

System Specifications Exam documentation Peripherals Mitsubishi HS-MD7000 Super-VHS video cassette recorder - Resolution: >400 lines - Video format: NTSC or PAL - Built-in digital time base corrector(tbc) eliminates jitter, skew, and color blurring during playback - Digital noise reduction - Super-fast drive for quick fast forward and rewind (approx. 120 seconds with T-120 tape) - Dimensions (h/w/d): 4.9 x 10.6 x 14.4 in/125 x 270 x 366 mm - Weight: 14.3 lbs/6.5 kg Sony UP D897MD digital B/W thermal printer (USB input) Sony UPD23-MD digital color printer (USB input) Support of a range of plain paper printers Support of up to three peripherals with shelf attachment Input and output ports Six available ports USB ports (2) Standard USB interface for support of qualified plain paper printers Composite video: output to external monitor, VCR or printer (optional) Black and white composite video output (optional) External print trigger LAN connector used with DICOM networking VGA output S-video output for VCR (optional) Footswitch port (optional) for connecting the optional footswitch RS-232 port to support data transfer User accessible and cleanable air filter Localization options Software: English, French, German, Italian, Spanish, Simplified Chinese, Japanese, Russian and Portuguese Training and user documentation: English, French, German, Italian, Spanish, Japanese, Simplified Chinese, Polish, Portuguese and Russian Online help: English, French, German, Italian, Spanish, Portuguese, Russian, Polish, Simplified Chinese and Japanese Power requirements Power: 1150VA Power consumed: 600VA Frequency: 50 to 60 Hz Voltage: 100 to 240 VAC Power cords Available for electrical standards worldwide Electrical safety standards CSA C22.2 No. 601.1 IEC 60601-1 UL 60601-1 EN60601-1 Environmental Temperature System: 0-40 C at 20-80% relative humidity VCR and printers: 0-40 C at 80% relative humidity (non-condensing) Heat dissipation : <2500 BTUs/hour (fully loaded) Maintenance andserviceability Philips Remote Service Network connectivity Optional service agreements Online and phone support Clinical applications support HD7, and Color Power Angio, are trademarks of Koninklijke Philips Electronics, N.V.

Transducers Transducer S4-2 s8 C5-2 C6-3 C8-5 C8-4v Type of Array Sector Sector Curved Curved Curved Curved Application Abdominal 0-4 cm Abdominal 5-10 cm Abdominal > 11 cm Gyn Vaginal 8-10 cm (max. depth) Gyn Transabdominal < 10 cm Gyn Transabdominal > 11 cm OB Vaginal 6-8 cm (max. depth) OB 1st Trimester 10-12 cm (max.) OB 2nd Trimester 12-18 cm (max.) OB 3rd Trimester 15-20 cm (max.) Pediatrics/Neonatal Abdominal Small Pediatrics Abdominal Large Pediatrics Cephalic Neonatal Cephalic Vascular 0-3 cm Vascular 3-8 cm Cardiac < 30 lbs/13.6 kg Cardiac 20-140 lbs/13.6-63.6 kg Cardiac > 140 lbs/63.6 kg Breast Transcranial Doppler Small Parts < 3 cm Small Parts > 3 cm Musculoskeletal Prostate Intraoperative Vascular Intraoperative Cardiac Biopsy Guides Reusable Reusable Reusable Reusable Reusable

Transducers Transducer E6509 L12-3 L12-5 15-6L D5009V Type of Array Curved Linear Linear Linear Non-Imaging Application Abdominal 0-4 cm Abdominal 5-10 cm Abdominal > 11 cm Gyn Vaginal 8-10 cm (max. depth) Gyn Transabdominal < 10 cm Gyn Transabdominal > 11 cm OB Vaginal 6-8 cm (max. depth) OB 1st Trimester 10-12 cm (max.) OB 2nd Trimester 12-18 cm (max.) OB 3rd Trimester 15-20 cm (max.) Pediatrics/Neonatal Abdominal Small Pediatrics Abdominal Large Pediatrics Cephalic Neonatal Cephalic Vascular 0-3 cm Vascular 3-8 cm Cardiac < 30 lbs/13.6 kg Cardiac 20-140 lbs/13.6-63.6 kg Cardiac > 140 lbs/63.6 kg Breast Transcranial Doppler Small Parts < 3 cm Small Parts > 3 cm Musculoskeletal Prostate Intraoperative Vascular Intraoperative Cardiac Biopsy Guides Reusable Reusable Reusable

Philips Healthcare is part of Royal Philips Electronics Interested? Would you like to know more about our imaginative products? Please do not hesitate to contact us. We would be glad to hear from you. On the web www.philips.com/healthcare Via email healthcare@philips.com By fax +31 40 27 64 887 By mail Philips Healthcare Global Information Center P.O. Box 1286 5602 BG Eindhoven The Netherlands By phone Asia Tel: +852 2821 5888 Europe, Middle East, Africa Tel: +49 7031 463 2254 Latin America Tel: +55 11 2125 0764 North America Tel: +425 487 7000 1 800 285 5585 (toll free, US only) 2008 Koninklijke Philips Electronics N.V. All rights are reserved. Philips Medical Systems Nederland B.V. reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Printed in USA 4522 962 31711/795 * FEB 2008