SC9: NON SURGICAL LASERS / IPLS/ LIGHT



Similar documents
Laser/Intense Pulse Light (IPL) - Code of Practice 7

Guidance Document For The Use of Lasers and Intense Pulse Light in Licensed Special Treatment Premises Within The London Borough of Brent

Independent Clinics Lasers and Intense Pulse Light Source Treatments

THE UNIVERSITY OF TEXAS MEDICAL BRANCH LASER SAFETY MANUAL ENVIRONMENTAL HEALTH & SAFETY

LASER SAFETY PROGRAM FOR CANISIUS COLLEGE (Department of Chemistry and Biochemistry) Effective: October 1, 2007 Revised: June 3, 2010

Rice University Laser Safety Manual

RELEVANT HACCP CHARTS: Preparation, Service

LASER SAFETY MANUAL UNIVERSITY OF KENTUCKY POLICIES AND PROCEDURES FOR LASER USERS REVISED EDITION 2012 ISSUED BY

Northern Illinois University Laser Safety Program

Announced Inspection

CERTIFICATE IN LASER AND LIGHT HAIR REMOVAL TREATMENTS

Cleaning of Laboratories

Introduction Risks & Hazards General Safety Operating Safety Maintenance Operating Procedures

OSHA Training Guidelines (An Unofficial Summary)

Staff Skin Care Policy

SIB70110 Graduate Certificate in Intense Pulsed Light and Laser Hair Reduction

Aseptic Technique Policy and Procedure

Occupational Health and Safety in the Laboratory (Undergraduate Students)

STANDARD LICENSING CONDITIONS FOR PREMISES OPERATING SPECIAL TREATMENTS

LASER SAFETY PLAN. The Hamilton Eye Institute at The University of Tennessee 930 Madison Avenue Memphis, Tennessee 38163

WORKPLACE HEALTH AND SAFETY AUDITING GUIDELINES

Hair. level 2 diploma in HairdressinG Practices. Candidate name: Candidate number:

Address of food business: 25 Ranworth Road, Norwich, NR5 8EB Date of Inspection: 27 July 2015

Save Face Laser & IPL Fact Sheet

Waste Management Policy

Checklist for a Physical Containment Level 2 (PC2) Laboratory Facility

Workshop Self Inspection Checklist WORK01

Safety and Radiation Protection Office Working with X-Ray Equipment

DISCLAIMER. Director-General, Agri-Food and Veterinary Services

Laser Classification. Laser Classes

Mercyhurst University Athletic Training Program Bloodborne Pathogens Exposure Control Plan

There are different types of lasers that according the wavelength of their beams have different indications; the most common ones used on skin are:

Cleaning and Support Services / Cleaning Services Supervision National Occupational Standards

Satellite Laser Ranging (SLR) International Workshop Safety Best Practices Discussion Clinic Group Chris Quinn

Hygiene Standards for all Food Businesses

Shop Safety. Action Tattoo 3525 Del Mar Heights Rd., Suite 7 San Diego, CA 92130

Guild Accreditation Information Pack

keep records up-to-date, accurate, easy to read and signed 1.11 by the client and practitioner

4 Quality Standards - Human Resources. Contents. 4.0 Introduction. 4.1 Management Structure and Staffing Levels

Educational Tool for Medical Laser Programs 1. Laser Safety

GUIDELINES FOR THE CLEANING UP OF BODILY FLUIDS

Inspecting Informing Improving. Hygiene code inspection report: South Western Ambulance Service NHS Trust

This document is meant to be a starting point for any company wanting to implement the safety passport scheme for their contractors on site.

The following standard practices, safety equipment, and facility requirements apply to BSL-1:

INFECTION CONTROL POLICY

The Hub Dental Practice

Laser Safety Self-Audit Checklist

We are the regulator: Our job is to check whether hospitals, care homes and care services are meeting essential standards.

No. Name of Legislation Applicable Issues and Requirements Demonstration of Compliance 1. Health and Safety at Work Act 1974

ITEC Unit 310 Make-up Application

City of Belmont Contractor Induction Program

Health and Safety Department. Health and Safety Policy. Version Author Revisions Made Date 1 Paul Daniell First Draft (in this format) 11 July 2014

Lakeside & Haverthwaite Railway Risk Assessment Form No. of Pages: 5

MANITOBA PATIENT SERVICE CENTRE STANDARDS

A Guide to developing BROTHEL OPERATIONAL PLANS POLICIES AND PROCEDURES

Ensure appropriate food safety practices are followed whilst food is prepared, cooked and served

LASER-PROTECTION INFORMATION

SAFETY SIGNAGE PROCEDURE

We are the regulator: Our job is to check whether hospitals, care homes and care services are meeting essential standards.

Laser Safety in the Dental Office By Jan LeBeau, RDH, BS/Chair of Dental Hygiene Pacific Dental Services, Co-Chair of Laser Safety

Domestic Assistants/Housekeepers A Workbook to record your training and personal development

Hair. level 2 diploma in hairdressing. Candidate name: Candidate number:

Environmental Health and Safety. Laser Safety Guide. Environmental Health and Safety

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

How To Inspect A Blood Bank

RULES OF THE ALABAMA BOARD OF MEDICAL EXAMINERS CHAPTER 540-X-11 GUIDELINES FOR THE USE OF LASERS AND OTHER MODALITIES AFFECTING LIVING TISSUE

1. GENERAL STATEMENT OF COMPANY HEALTH, SAFETY AND ENVIRONMENTAL POLICY

Safe Bathing, Hot Water and Surface Temperature Policy

IAC 2/10/10 Professional Licensure[645] Ch 60, p.1

Private Water Supplies Sampling Manual. A Field Guide

ACCIDENT & INCIDENT RECORDING AND REPORTING POLICY

Required Biosafety Level Three (BSL-3) Practices, Procedures, Facilities, and Safety Equipment For BSL-3 and BSL3/2 Laboratories

Review Date 01/09/2015 Director of Estates and Facilities Expiry Date 11/09/2016 Withdrawn Date

Good Hygiene Practices - presentation by -

We are the regulator: Our job is to check whether hospitals, care homes and care services are meeting essential standards.

Section 10. Guidelines for the Safe Handling and Disposal of Needles and Sharps

The methods of implementation of these elements of the standard are discussed in the subsequent pages of this ECP.

PI s Name Date Bldg./Rm# CDC Biosafety Level 3 (BSL-3)

Shampoo and conditioning

We are the regulator: Our job is to check whether hospitals, care homes and care services are meeting essential standards.

Employee Health and Safety Induction Training Record

Safety Resources from

Laser Safety Plan. 1 P age

Welcome to the Health and Community Services Module.

POLICY Contents. 1.0 Introduction Statement

HEALTH AND SOCIAL CARE E QUALIFICATIONS HE

Local Enhanced Service Specification for the Supply of Pharmaceutical Services to Care Homes through Community Pharmacy

The Business Rules for Approved Inspection Stations

ADULT FOSTER HOME INSPECTION REPORT SECTION Y N P NA PLAN/DATE OF CORRECTION

Health and Safety Performance Standard HSPS 006 Food Safety

Student Shop Safety Policy GS92 Page 1

We are the regulator: Our job is to check whether hospitals, care homes and care services are meeting essential standards.

POLICY ON OCCUPATIONAL HEALTH AND SAFETY RISK MANAGEMENT

APPROVAL REVIEW PROCEDURES

The Management of Asbestos containing Materials

THE PONY CLUB RISK ASSESSMENT CHECK LIST - SUMMER CAMP

EXPOSURE CONTROL PLAN (sample) 1 Child Care Directors and Employers

We are the regulator: Our job is to check whether hospitals, care homes and care services are meeting essential standards.

Biosafety Level 2 (BSL-2) Safety Guidelines

Biosafety Level 2 Criteria

Transcription:

DEFINITIONS SC9: NON SURGICAL LASERS / IPLS/ LIGHT The conditions in this part refer specifically to Class 3B lasers, Class 4 lasers and Intense Light Source systems (ILS) used for non-surgical cosmetic procedures. Laser This is an acronym of Light Amplification by Stimulated Emission of Radiation. In the beauty industry lasers are generally used for non-invasive cosmetic treatments, such as removal of; hair, tattoos, birthmarks, acne scarring, and other blemishes, from the skin. The mode of emission of the radiation can be continuous, wave, or pulsed. Class 3B lasers Radiation in this class is likely to be dangerous, maximum output into the eye must not exceed 500mW. The radiation can be hazardous to the eye or skin, but viewing of diffuse reflection is safe. Class 4 laser Highest class of laser radiation, diffuse reflection is also hazardous. If used incorrectly it can cause serious skin and eye injuries and is capable of setting fire to material. Intense Light Systems (ILS)/ Intense Pulsed Light (IPL) Intense light systems are generally treated as class 4 lasers. Intense Pulsed light (IPL) systems fall into this category and are the intense light system generally used for non-invasive cosmetic treatments found in the beauty industry. IPL is pulsed or shuttered emission which gives tissues time to cool between pulses. Laser Protection Advisor - LPA The LPA is the person providing expert advice on laser/ipl safety. The LPA will carry out hazard analysis and risk assessment for each laser/ipl installation and advise on training, protective eye wear and ensure local rules are produced, signed, dated and implemented for each installation. For licensing purposes an initial visit is required by an LPA prior to operation. Local Rules The Local Rules are produced by the LPA and are a set of rules specific to each installation, detailing safe working practice and day-to-day safety management. Laser Protection Supervisor LPS The LPS is usually an employee of the business and is responsible for; supervising the work of all laser/ipl authorised users, the safety and security of all laser/ipl, ensuring all users are appropriately trained to operate the laser/ipl, and that the Local Rules document is followed on a day to day basis. Authorised User The Authorised user is the individual who operates the laser/ipl equipment to treat clients.

1. AGE RESTRICTIONS No one under the age of 16 will be permitted to have treatments without a parent or guardian being present and signing the consent form. 2. CLIENT CONSULTATION A full client consultation must be carried out at the time of a first visit and prior to any treatment. This must include a thorough medical history in relation to the treatment being requested and full explanation of any possible contra-indications. Where any medical conditions exist the client must confirm to the therapist that they have taken advice from their GP regarding the treatment before any treatment can be commenced. 3. VISUAL ASSESSMENT An assessment of the condition of the area to be treated must be carried out prior to commencing treatment. Where necessary notes/diagrams should be made regarding conditions, areas not to be treated. Treatments must not be carried out on or within 10cms of an infected area of skin, a rash, cut, broken skin or other wound. 4. AUTHORISED USER REGISTER A register must be kept of all personnel authorised to operate laser/ipl equipment. 5. RECORD KEEPING Records must be kept for every client (including walk-ins/one offs). The records must include details of medical history checks and steps taken to verify the age of the client including their date of birth and the type of identification provided (where appropriate). This record must be signed by either the client/parent/guardian (as appropriate) as a declaration of agreement to proceeding with the treatment having been explained and understanding any associated risks. In addition a treatment register must be kept to include the following:- Treatment Register A treatment register shall be completed every time the laser/ipl is operated, including the following information: - the name of the person treated; - the date and time of treatment; - the name and signature of the laser/ipl operator; - the nature of the laser/ipl treatment given - the treatment parameters - any accidents or adverse effects. 6. PERSONAL HYGIENE Persons carrying out treatments must ensure that:- - their hands are kept clean and washed immediately prior to carrying out a treatment, - they maintain a high degree of personal cleanliness and wear suitable, clean and appropriate protective clothing, - they do not smoke or consume food or drink during the course of a treatment. Persons shall not administer treatments whilst afflicted by either a known or suspected ailment or being a carrier of a disease likely to be transmitted during treatment.

Persons carrying out treatments shall ensure that any open sores, cuts, boils, broken skin or other open wounds are effectively covered with waterproof impermeable dressings. If such cuts are on the hands gloves shall be worn over the waterproof dressings. 7. INFECTION CONTROL (a) Couches, tables and trolleys must be wiped with a suitable disinfectant between clients. If towels are used a clean towel must be used for each client. (b) Couch roll must be changed between clients. (c) Where hair needs to be removed disposable razors must be used and thrown away after each client. For information on the level of disinfection required for different furniture, fittings and equipment see General Terms and Conditions, Part II, Item 23. 8. LASER/ IPL TREATMENT PROTOCOL DOCUMENT (a) The licence holder must ensure that a treatment protocol document is produced and signed by an Expert Medical Practitioner (EMP) in relation to the licence holder s equipment. (b) The treatment protocol should be signed and dated by the EMP to confirm authorisation, should be reviewed annually and include a projected date for review. The treatment protocol must be retained onsite. (c) The treatment protocol sets out the necessary pre-treatment checks and tests, the manner in which the laser/ipl is to be applied, the acceptable variations in the settings used, and when to abort a treatment. (d)a separate treatment protocol should be in place for each laser/ipl in use at the licensed premises. (e) The treatment protocol must include the following: - name and technical specifications of the equipment - contraindications - treatment technique general - treatment technique hair reduction - client consent prior to treatment - including checking skin type and pigmentation - cleanliness and infection control - pre-treatment tests and pre-treatment instructions - post-treatment care - recognition of treatment-related problems - list of photo sensitisers - emergency procedures - permitted variation on machine variables - procedure in the event of equipment failure - written aftercare advice must be provided after the first treatment 9. LASER/ IPL LOCAL RULES (a)the Licence holder shall initially employ the services of a certificated Laser Protection Advisor (LPA) to produce local rules. A copy of the LPA s certificate and a copy of a contract between the licenced premise and the LPA must be available onsite. In cases where a device and room has been

previously assessed the Licence Holder must contact the LPA who carried out the assessments to get copies of these documents. (see Appendix 1) (b) A copy of the last LPA audit report must be available onsite for review by the Authorised Officer. If a copy is not available the Licence Holder must contact the LPA who wrote the Local Rules and request a copy of the last audit or a new audit. (d) After the initial inspection if there are no significant changes to the premises i.e. change of room, change of Laser/IPL equipment, treatments etc, then the initial assessments will stand and therefore no further action is required. (e) It will be at your discretion and consideration as to whether you wish to continue to engage the services of your LPA. If however there are any significant changes in relation to the Laser/IPL operations at the premises, i.e. change of room, change of Laser/IPL equipment, or change in any additional treatments offered, then you will require a further inspection from your LPA to re-assess and document these changes. (f) Changes in relation to the laser user(s) would not require a new assessment just an update in your user register with copies of their qualifications and training. (g) Both the Local Rules and the Treatment Protocol must be available for reference, next to each machine. 10. APPLICATION OF LOCAL RULES (a) The laser/ipl must only be used in accordance with the local rules. (b) Authorised Persons must sign statements that they have read and understood the local rules. These statements must be available onsite for inspection by an Authorised Officer at all times. 11. LASER/IPL CONTROLLED AREA (a) The area around working lasers/ipl shall be controlled to protect other persons while treatment is in progress. The controlled area shall be clearly defined and not used for other purposes. (b) A suitable safety warning sign ( Eye Protection and Controlled Area ) or light entry system which complies with current British Standards shall be in place on the door of the controlled area. (c) All lasers/ipl shall comply with current standards (BS EN 60601-2-22 for medical lasers and BS 60601-2-57 and shall display labels identifying them, their wavelength or range of wavelengths and the maximum output power of the radiation emitted. The labels shall be clearly visible on the front or side of the machine. (d) The door to the controlled area shall be fitted with a suitable device which can be operated from the outside in an emergency (e) Any windows in the controlled area shall be fitted with opaque blinds approved by the LPA. (f) The controlled areas shall be kept clear of clutter, mirrors shall be avoided and jewellery shall not be worn. (g) Surfaces within the controlled area shall be of a matt or eggshell Finish.

(h) Protective eyewear shall be worn by everyone within the controlled area whenever there is a risk of exposure to laser/ipl. All protective eyewear shall be marked with the wavelength range and protection offered as detailed in the local rules document. They shall be in a clean serviceable condition. (i) No more than one laser/ipl shall be switched on during the client treatment. (j) When the laser/ipl is in operation the number of persons in the room shall be kept to a minimum. (k) The laser protection supervisor shall ensure that the key to any laser/ipl equipment is kept in a secure and separate area when not in use and that only authorised users have access to the key. (l) Lasers/IPL shall be serviced annually and a record kept of servicing and repairs with the local rules document. (m) A notice must be fixed to the laser/ipl indicating that its use is subject to the Local rules. 12. TRAINING OF AUTHORISED USERS (a) Only suitably qualified therapists listed on the premises licence may operate and provide laser or IPL treatments. Qualifications must be accredited, nationally recognised or of an equivalent standard and must cover Salon Hygiene/Infection Control or similar. Where Council is concerned that a therapist does not have adequate infection control knowledge the therapist may be required to complete a questionnaire on infection control. Any therapist failing to satisfactorily complete the questionnaire will be required to undertake further training to improve knowledge before they can be listed on the premises licence. (b) All authorised users of laser/ipl shall be trained to at least the Core of Knowledge Certificate level and records of such training shall be kept on site with the local rules. (c) Training on the specific equipment in use at the premises shall also be recorded. Such training should be refreshed every 3-5 years. 13. LASER PROTECTION SUPERVISOR A suitably qualified member of staff on the premises shall be identified, in writing, as the laser protection supervisor they will have day to day to responsibility of ensuring the local rules are followed. 14. AFTERCARE ADVICE Appropriate aftercare advice must be provided following each treatment. This must include information on actions to take if any adverse conditions occur. Where possible this should be given orally and in written form for the client to take away.

APPENDIX 1 Laser / IPL Local Rules Document Potential Hazards List all types of hazards including fire, skin and eye injuries, electrical etc. Device Description Description of all devices including output, serial numbers etc. Treatment Protocol Reference to separate document produced by the Expert Medical Practitioner. Written Procedures Supported by reference to user manual/training manual etc. Adverse Incident Procedure Details of actions that shall be taken in cases of emergency e.g. eye exposure Name, address and telephone no of local accident and emergency department. Any incidents must also be reported to Council so include local Environmental Health contact details. Emergency Shutdown Procedure Instructions as set down in manufacturer s manual or treatment protocol. Register of Authorised Users Details of trained personnel with signed declarations of individuals. Laser Protection Advisor Contact details of the LPA