FloBoss 104 Flow Manager



Similar documents
FloBoss 107 Flow Manager

The DL8000 Preset Controller. The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers

ROC800-Series Advanced Pulse Module

Rosemount 3095 MultiVariable Transmitter with MODBUS Protocol ProductDiscontinued

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

ROC Protocol Specifications Manual

XFC 6201EX flow computer XSeries products

ControlWave Micro. Features. CPU Options. Base and Expansion Units. Product Data Sheet D301671X012 September Remote Automation Solutions

ROC800L Liquid Application Software

Rosemount 751 Field Signal Indicator

SupportNet Technical Services

Microcor Wireless Transmitter (MWT)

3DLevelScanner II TECHNICAL DATA SHEET

Rosemount 3095FC MultiVariable Mass Flow Transmitter

3500/93 System Display

Rosemount 333 HART Tri-Loop

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Scanner 1141C. Single & Dual Stream Measurement Remote Telemetry Unit (RTU) NUFLO MEASUREMENT SYSTEMS

A-307. Mobile Data Terminal. Android OS Platform Datasheet

O C M III. Open Channel Flow Monitor

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Technical Information RIA14

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

The L&J Engineering Model MCG 1500SFI Servo Gauge

Ron 3025 Crane Scale with 1"/25mm Display

Technical data sheet TDS0070

Model: DC-A2IO Advanced HVAC Controller

Temperature & Humidity SMS Alert Controller

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

Fisher 846 Electro-Pneumatic Transducer

3500/62 Process Variable Monitor

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

Flow Monitoring System

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)

Duct Humidity Transmitter

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Remote Level Monitoring Unit

Product Specification instalert Rapid Messenger Variable Message Sign

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

OpenEnterprise. Lifecycle Services

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

HMI display Installation Guide

BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices

Centro-Matic Automatic Lubrication Systems System Controls

Micro Motion Net Oil Computer Software and NOC System

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

S-series SQ Controller

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

PowerLogic Sub Meter Display (SMD and SMDOPN)

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Regards from the Team at Rheology Solutions.

Foxboro Evo Process Automation System

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Section TELEPHONE AUTOMATIC DIALER SYSTEM

3500/25 Enhanced Keyphasor*Module

Micro Motion 3098 Gas Specific Gravity Meter

SureCross DX99 Intrinsically Safe (IS) FlexPower Node with Integrated Battery

Fisher FIELDVUE DVC2000 Digital Valve

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

Bristol ControlWave Redundant Control

ANNUBAR FLOW CALCULATION PROGRAM (For the FloBoss 103) User Manual (QER 04Q019)

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Technical Data Sheet. 3DLevelScanner

Model 3051 Pressure Transmitter with HART Protocol

NETWORK ENABLED EQUIPMENT MONITOR

Remote Monitoring and REC 501 Control Unit Product Guide

Nardalert S3 Non-Ionizing Radiation Monitor

Compact pressure switch Flameproof enclosure Ex d Model PCA

1701/22 FieldMonitor Management Interface Module

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter

Rosemount 1199 Submersible Seal

Rosemount 333 HART Tri-Loop

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Rosemount 248 Wireless Temperature Transmitter

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Communication Unit 560CMU05 Data sheet

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

THERMAL MANAGEMENT SOLUTIONS

Fisher 646 Electro Pneumatic Transducer

1756 ControlLogix Chassis Specifications

Rosemount 248 Temperature Transmitter

4-Channel Thermometer / Datalogger

S-series Mass Connection Solutions

INTREPID Perimeter Intrusion Detection System

ROCLINK for Windows Configuration Software

Perimeter Security System

STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Transcription:

FB104 Product Data Sheet D301200X012 June 2016 FloBoss 104 Flow Manager The FloBoss 104 Flow Manager (FB104) measures, monitors, and provides control of gas flow for a single rotary meter or turbine meter, using a Pulse Interface Module. This economical flow computer reliably and accurately performs gas flow calculations, data archival, and remote communications. The FB104 Flow Manager has an explosion proof, weathertight enclosure, with an optional window and LCD display. This self-contained flow computer has a processor circuit board, internal batteries, a termination board, terminal wiring for a 2- or 3-wire RTD, optional I/O points, and an optional communication card. The FB104 unit consists of the following components and features: A 32-bit main microprocessor with 128 KB of flash boot ROM, 2 MB for flash ROM, and 512 KB of RAM data storage. Pulse Interface Module for pulse counts and pressure measurement. Support for a 100 ohm, platinum RTD. Weather-tight enclosure. Local Operator Interface port (LOI). EIA-485 (RS-485) Communications Port. Firmware The FB104 firmware provides the following functionality. For more information about the firmware, refer to Product Data Sheet FB100:FW1. AGA7 flow calculations (with user-selectable AGA8 compressibility) for a single rotary or turbine meter. Memory logging of 240 alarms and 240 events. Standard History Archival of 35 days of hourly data for up to 35 points. Extended History Archival for up to 15 points at a configurable interval. Radio power control. Closed-loop PID control capabilities. Logic and sequencing control using two user-defined Function Sequence Table (FST) programs. Alarm call-out to a host, known as Spontaneous Report By Exception (SRBX). ROC and Modbus protocol support. User C programs support for alternate measurement standards and specialty applications. Contact your local sales representative for available programs. Pass-Through communications on multiple ports. The FB104 unit calculates gas flow in accordance with the American Gas Association (AGA) and American Petroleum Institute (API). The FloBoss unit performs AGA7 flow calculations, using AGA8 compressibility methods. Pulse counts and pressure measurement come from the Pulse Interface Module, and flowing temperature is acquired directly from a RTD probe. The FloBoss unit maintains API Chapter 21.1 compliant historical archives. Configuration Software The field I/O, pulse count inputs, flow calculation, history logging, and all other functions are accessed and configured using ROCLINK 800 Configuration Software (see Product Data Sheet RL800). Termination Board The termination board provides terminations for the RTD input, the LOI communications port, the EIA-485 (RS-485) communications port, the optional communications card, and a power supply. FloBoss 104 Flow Manager (shown with optional 2-watt solar panel)

FB104 June 2016 The Local Operator Interface (LOI) port provides a direct, local link between the FloBoss unit and a personal computer (PC). A PC on the LOI port running ROCLINK 800 software can configure the functionality of the FloBoss unit and monitor its operation. In addition, a host computer can remotely configure the FloBoss unit through the optional communications port. Diagnostics Four diagnostic inputs in the FloBoss unit are dedicated to monitoring internal voltage, battery voltage, charge input voltage, and enclosure temperature. Pulse Interface Module The Pulse Interface Module consists of two parts: a pulse counter interface and optional pressure transducers. When used with a Rotary meter, the Pulse Interface Module creates and measures electrical signals (pulses) from the rotary meter and raw pressure inputs from the pressure transducers. The module automatically interprets the direction of rotation (CW or CCW) without any extra parts. The module has a resolution of 1000 pulses per revolution. When used with a Turbine input, the pressure is measured by the pressure transducers and pulses from the turbine meter are measured by the Pulse Input on the optional I/O board. The Pulse Interface Module makes the readings available to the processor board. The pressure inputs are read from Analog Inputs, while the pulse counts are read as a Pulse Input. The optional integral pressure transducers provide the measurement of the line pressure (P1) and can optionally measure auxiliary pressure (P2). The Pulse Interface Module mounts to the base of the FloBoss 104 unit. The Pulse Interface Module has a noncontact interface to the mechanical interface of the meter. The FB104 assembly has holes on the base of the Pulse Interface Module housing that allow FB104 to be mounted directly and easily on a rotary or turbine meter. Housing The explosion-proof, type 4 enclosure protects the electronics from physical damage and harsh environments. The enclosure allows the FB104 to be located in Class I, Div.1 areas, when properly installed with conduit seals and a plug in the top of the housing. When the optional solar panel mast is attached, the enclosure must only be located in Class I, Div. 2 or non-hazardous areas. The caps at either end of the enclosure can be unscrewed to allow field maintenance. The enclosure has two ¾-inch pipe threaded holes for field wiring, communications or panel access. Mounting The Pulse Interface Module housing has bracket holes that allow assembly to mount to pipestand or bracket. Options Liquid Crystal Display (LCD) - Through the optional LCD display, you can view selected data stored in the FloBoss unit. The LCD is typically used to display flow data, time and date, real-time parameters and user-specified parameters. The LCD displays two lines: the top line has 8 numeric characters and the bottom line has 5 alpha-numeric characters. The display scrolls through the configured list of items, when activated by the user. Dial-up Modem Card, EIA-232 (RS-232) or EIA-485 (RS-485) Serial Communications Card - Optional communications cards (installed on the Com2 port) provide the ability to send and receive data remotely via a dial-up modem card, EIA-232 (RS-232) serial communications card, or an EIA-485 (RS-485) serial communications card. 6 Points of Expansion I/O - The termination board provides terminations for six optional I/O points. Five of the six points of I/O are selectable. The six points of I/O consists of one Discrete Output (non-selectable), two Analog Input/Discrete Input (software-selectable), one Analog Output/Discrete Output (jumper-selectable), and two Pulse Input/Discrete Input (software-selectable). See Specification Sheet 5.3:IO6. Solar Panel Mast Assembly - Optional solar panels with mast and mounting hardware provide either 2 or 5 watts of power for the FB104. As shown on page 1, the solar panel mast assembly mounts to the top of the FB104 enclosure. See the approval section for installation. Internal Batteries The optional internal, rechargeable, lead-acid batteries provide 6.2 volts dc to the FB104 unit. The batteries are re-chargeable by means of the charger board. See the approval section for installation. Warning: Connecting the FB104 to a continuous power source without removing the battery charger module may result in battery overcharging and failure. See Section 3.5.1, Overcharging Potential in the FloBoss 103 and 104 Flow Manager Instruction Manual (part D301153X012). Accessories Accessories available for the FB104 include a Local Operator Interface cable (required for local configuration). Contact your local sales representative for more information. 2 www.emersonprocess.com/remote

June 2016 FB104 FloBoss 104 Flow Manager CPU Module Processor 32 bit, running at 3.68 MHz Memory Program 2 MB flash EPROM (programmable) for firmware and configuration Clock Diagnostics Communications Ports on CPU module Protocols Inputs/Outputs Data Boot 512 KB SRAM 128 KB Flash EPROM Real Time. Year/Month/Day and Hour/Minute/ Second. Battery Backed. ±5 second/year accuracy These conditions are monitored and alarmed: Pulse Interface Module and RTD point fail; battery, charger and internal voltages; internal temperature. LOI (Local Operator Interface) COM1 COM2 (Host) RTD Input Quantity 1 Power Internal Batteries External Power Charging Input EIA-232 (RS-232C), Software configurable, 1200 to 19,200 bps rate selectable EIA-485 (RS-485), software configurable, 1200 to 19,200 bps rate selectable EIA-232 (RS-232), EIA-485 (RS-485), or 2400 baud Dial-up Modem. EIA- 232, EIA-485, or Modem requires optional communications card. ROC or Modbus Slave or optional Modbus Host (ASCII or RTU) on all ports Type 2 or 3-wire RTD element with alpha of 0.00385. Terminals Sensing Range 1 Accuracy 1 RTD+ current source, RTD+ signal positive input, and RTD RET signal negative input -40 to +240 C (-40 to +464 F) (default) ±0.2 C (0.64 F) over sensing range (includes linearity, hysteresis, repeatability) 1. The accuracy depends on the span calibrated for the sensing range of the RTD Input. The sensing range is the difference between the calibrated zero and calibrated span. The sensing range may be changed from the defaults during calibration. When the sensing range is less than or equal to 300 C, the accuracy is 0.2 C. When the sensing range is greater than 300 C, the accuracy is 0.5 C. Sensing range limits are -40 to +800 C. Ambient Temperature Effects per 28 C (50 F) Filter Resolution Sample Period ±0.50 C (0.90 F) for process temperatures from -40 to +240 C (-40 to +464 F) Band-pass hardware filter 16 bits 1 second minimum Lead-acid. Rechargeable. Nominal 6.2 V dc, 2.5 amp-hour. Battery life with no charging input and no communications: 1 week. 8-28 V dc. Reverse Polarity Protection. www.emersonprocess.com/remote 3

FB104 June 2016 Input Power Solar Panel (optional) 2 Watts Output 9 V nominal Physical Dimensions Weight 10-15 ma nominal. 20 ma at 100% duty cycle (battery charging not included) Size 5 Watts Output 9 V nominal Size 114 mm by 159 mm (4.5 in. by 6.25 in.) 222 mm by 229 mm (8.75 in. by 9 in.) 160 mm H by 148 mm W by 216 mm D (6.3 in H by 5.8 in W by 8.5 in D), excludes mounting flange and interface. Depth, D, is end cap to end cap dimension. 4.3 kg (9.5 lbs) approximate, with Pulse Interface Module Enclosure Housing and Cap Die-cast aluminum alloy with iridite plating and paint Environmental Operating Temperature Storage Temperature Operating Humidity Radiated/Conducted Transmissions Radiated Emissions -40 to +75 C (-40 to +167 F) LCD Display -50 to +85 C (-58 to +185 F) 5 to 95%, non-condensing -20 to +75 C (-4 to +167 F) Meets requirements of IEC 61326 Electrical Equipment for Measurement, Control and Laboratory Use, Industrial locations Meets FCC Part 15, Class A Vibration Meets SAMA PMC 31.1 Pressure Transducer Input Type Range Options Operating Temperature Accuracy (includes linearity, hysteresis, and repeatability) Sealed gauge 0 6.9 bar (0 100 psi) 0 20.7 bar (0 300 psi) 0 69.0 bar (0 1000 psi) 40 C to +70 C ( 40 F to +158 F) Range 0 6.9 bar (0 100 psi) 0 20.7 bar (0 300 psi) 0 69.0 bar (0 1000 psi) Ambient Temperature Effect Range 0 6.9 bar (0 100 psi) Physical (Pulse Input Module) 0 20.7 bar (0 300 psi) 0 69.0 bar (0 1000 psi) Construction Interface housing 6061 aluminum, painted ±0.35% of URL ±0.35% of URL ±0.35% of URL ±0.35% of URL per 50 F (28 C) over the operating temperature range ±0.35% of URL per 50 F (28 C) over the operating temperature range ±0.35% of URL per 50 F (28 C) over the operating temperature range 4 www.emersonprocess.com/remote

June 2016 FB104 Pressure Transducers SST Process Connections Approvals Product Markings for Hazardous Locations Mounting flange 6061 aluminum 1/4-18 NPT, located on sides of interface. CSA C-US Certified by CSA Model W40106 Class I Division 1, Groups C & D Explosion-proof Type 4 enclosure Model W40106 Class I, Division 2, Groups A, B, C, & D Temperature Code T3 Non-incendive Type 4 enclosure Model W40112 Class 1, Division 2, Groups A,B,C, & D Temperature Code T3 Non-incendive (T amb =75 C) Type 4 enclosure Evaluated per Approval Standards CAN/CSA-C22.2 No. 0-M91 CAN/CSA-C22.2 No. 94-M91 CSA-C22.2 No. 30-M1986 CSA-C22.2 No. 142-M1987 CSA-C22.2 No. 213-M1987 UL No 50 (11 th Edition) UL No. 1203 (4 th Edition) UL No. 1604 (3 rd Edition) ANSI/UL No 508 (16 th Edition) ANSI/ISA No. 12.12.01-2007 ISA No. 12.27.01-2003 www.emersonprocess.com/remote 5

FB104 June 2016 ATEX Certified by LCIE Model W40116 Cert LCIE 03 ATEX 6221 X X/05 EX II 2 G Ex d IIB T5 Gb (T amb = 75 C) Type d or Flameproof (Zone 1) Model W40116 Cert LCIE 13 ATEX 1033 X EX II 3 G Ex na IIC T3 Gc (T amb = 75 C) Type n (Zone 2) IECEx Evaluated per Approval Standards Certified by IECEx EN60079-0:2012(Flameproof) EN60079-1:2007(Flameproof) EN60079-15:2010(Type N) EN60079-0:2012(Type N) IEC 60529 Model W40149 Cert IECEx LCI 08.0039X Ex d IIB T5 Gb (T amb = 75 C) Type d or Flameproof (Zone 1) Model W40149 Cert IECEx LCI 08.0015 Ex na IIC T3 Gc (T amb = 75 C) Type n (Zone 2) Model W40150 Cert IECEx LCI 08.0015 Ex na IIC T3 Gc (T amb =75 C) Type n (Zone 2) Miscellaneous Approvals RoHS (China) Evaluated per Approval Standards IEC 60079-0:2011 Edition 6.0 IEC 60079-1: 2007 Edition 6.0 IEC 60079-15:2010 Edition 4 IEC 60529 6 www.emersonprocess.com/remote

June 2016 FB104 For customer service and technical support, visit www.emersonprocess.com/remote/support. Global Headquarters, North America, and Latin America: 6005 Rogerdale Road Houston, TX 77072 U.S.A. T +1 281 879 2699 F +1 281 988 4445 www.emersonprocess.com/remote Europe: Unit 8, Waterfront Business Park Dudley Road, Brierley Hill Dudley UK DY5 1LX T +44 1384 487200 F +44 1384 487258 Middle East/Africa: Emerson FZE P.O. Box 17033 Jebel Ali Free Zone South 2 Dubai U.A.E. T +971 4 8118100 F +971 4 8865465 Asia-Pacific: 1 Pandan Crescent Singapore 128461 T +65 6777 8211 F +65 6777 0947 2004 2016, a business unit of Emerson Process Management. All rights reserved. This publication is for informational purposes only. While every effort has been made to ensure accuracy, this publication shall not be read to include any warranty or guarantee, express or implied, including as regards the products or services described or their use or applicability. (RAS) reserves the right to modify or improve the designs or specifications of its products at any time without notice. All sales are governed by RAS terms and conditions which are available upon request. RAS accepts no responsibility for proper selection, use or maintenance of any product, which remains solely with the purchaser and/or end-user.