Chemical Structure of the polymer showing end groups: CH 3 CH 2 CH H



Similar documents
Tips & Tricks GPC/SEC: Analysis and Calibration For Low Molar Mass Macromolecules

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

Laboratory procedures in polymer chemistry

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

Research for leachables of nuclear grade cation exchange resin

molecules ISSN

An Introduction to Gel Permeation Chromatography and Size Exclusion Chromatography PRIMER

SUCRALOSE. White to off-white, practically odourless crystalline powder

Size Exclusion Chromatography

Size-exclusion Chromatography of Polymers. Bernd Trathnigg

Analysis of Vegetable Oils by High Performance Liquid Chromatography

Diffusion and Fluid Flow

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

PURIFICATION TECHNIQUES

1 Introduction The Scientific Method (1 of 20) 1 Introduction Observations and Measurements Qualitative, Quantitative, Inferences (2 of 20)

POLYDIMETHYLSILOXANE

Affi-Prep Protein A Matrix Instruction Manual

ß-CYCLODEXTRIN SYNONYMS

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

EUDRAGIT E 100, EUDRAGIT E PO and

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

MINERAL OIL (MEDIUM VISCOSITY)

Supplementary Information for

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Purification of reaction mixtures using flash chromatography.

Determination of Caffeine in Beverages HPLC-1

4026 Synthesis of 2-chloro-2-methylpropane (tert-butyl chloride) from tert-butanol

Chapter 13. Properties of Solutions

VCE CHEMISTRY : UNIT 3 SAMPLE COURSE OUTLINE

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Supporting Information. A General Route to Very Small Polymer Particles with Controlled Microstructures

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

ERDOSTEINE - MONOGRAPH.

Vitamin C quantification using reversed-phase ion-pairing HPLC

Correlation of the Mass Spectrometric Analysis of Heat-Treated Glutaraldehyde Preparations to Their 235nm / 280 nm UV Absorbance Ratio

2. Why does the solubility of alcohols decrease with increased carbon chain length?

Quality. Now Certified to ISO 9001:2008

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

THE FOLLOWING TEXT ON BIO-OIL EXTRACTION IS AN EXCERPT FROM THE FINAL TECHNICAL REPORT SUBMITTED BY HNEI TO OFFICE OF NAVAL RESEARCH UNDER GRANT

Tips & Tricks GPC/SEC: Select the Right Columns for Your Molar Mass Range

Gel Filtration Standard

Light-driven Nanoscale Chiral Molecular Switch: Reversible Dynamic Full Range Color Phototuning

Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC

ProteinChip Energy Absorbing Molecules (EAM)

ISOLATION OF CAFFEINE FROM TEA

GPC Characterization for Assessing Compatibility Problems with Heavy Fuel Oils

Lecture Chromo-3: Gas Chromatography. CHEM 5181 Fall 2004 Mass Spectrometry & Chromatography. Jessica Gilman and Prof. Jose-Luis Jimenez CU-Boulder

Performance and advantages of qnmr measurements

DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA PARACETAMOL ORAL SUSPENSION (September 2010)

EXPERIMENT Aspirin: Synthesis and NMR Analysis

A Ratiometric NMR ph Sensing Strategy Based on Slow- Proton-Exchange (SPE) Mechanism

DYNAMIC LIGHT SCATTERING COMMON TERMS DEFINED

AMD Analysis & Technology AG

Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs

Molar Mass of Polyvinyl Alcohol by Viscosity

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

Elements of Addition Polymerization. Branching and Tacticity. The Effect of Crystallinity on Properties

Marmara Üniversitesi Fen-Edebiyat Fakültesi Kimya Bölümü / Biyokimya Anabilim Dalı PURIFICATION AND CHARACTERIZATION OF PROTEINS

Plant Genomic DNA Extraction using CTAB

48 Practice Problems for Ch Chem 1C - Joseph

#10 Condensation Polymerization: Preparation of Nylon 6/6

Insight Into Chain Dimensions in PEO/Water Solutions

How To Choose A Total Organic Carbon Analyzer

NMR and other Instrumental Techniques in Chemistry and the proposed National Curriculum.

TANNIC ACID. SYNONYMS Tannins (food grade), gallotannic acid, INS No. 181 DEFINITION DESCRIPTION

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

Dissolved and precipitated oxalate

Peptide Antibody Production

An In-Gel Digestion Protocol

CERTIFICATE OF ANALYSIS Methyl 4-Hydroxybenzoate

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

Bio-Gel P Polyacrylamide Gel Instruction Manual

Optical anisotropy of flexible polyimide thin films

ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual

Biomaterials in tissue engineering

Syllabus CHM 2202 Organic Chemistry Laboratory II Spring 2011

LIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: )

Validation and Calibration of Analytical Instruments a D.Gowrisankar, b K.Abbulu, c O.Bala Souri, K.Sujana*

Chapter 28: High-Performance Liquid Chromatography (HPLC)

Extraction and Properties of the Polyphenol, Catechin, as an Antioxidant

The Impact of Thermal Stability on the Performance of Polymeric Dispersants for Boiler Water Systems

Applications of Organic Solvent Nanofiltration in the Process Development of Active Pharmaceutical Ingredients. Dominic Ormerod

Chapter 5 Classification of Organic Compounds by Solubility

Green Principles Atom Economy Solventless Reactions Catalysis

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

Supporting Information

Time out states and transitions

Chapter 21 Principles of Chromatography and Mass Spectrometry Problems 1,2,3,4,8,9,11,13

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

INSTRUCTIONS Edition AC

On-line Dissolved Gas Analysis

Transcription:

Polymer Reference Materials-Polystyrene Introduction Reference materials are used for calibration and performance evaluation of instruments used as part of overall quality assurance programs of polymer. These materials support the development of new measurement methods and characterize new materials. The synthesis and characterization of our polymer reference materials are achieved meticulously. Above all, the user can be assured of receiving a well-characterized and quality product. Chemical Structure of the polymer showing end groups: CH 3 H 3 C CH 2 C H CH 2 CH H n Molecular weight based reference polymers Polymer Source offers a wide range of reference polymeric materials (RM) for both organic and aqueous phase applications. New reference polymers are added regularly. A wide range of polymers with number average molecular masses (M n ) (oligomers to 10 million) have been covered. Molecular weight values are characterized by various analytical techniques. Interfacing chromatographic methods with other analytical techniques can significantly increase the amount of information available for polymer characterization. The techniques used for characterization are: size exclusion chromatography (SEC), nuclear magnetic resonance 1

(NMR), intrinsic viscosity, thermal analysis, and Matrix Assisted Laser Desorption Ionization-Time of Flight-Mass Spectrometry (MALDI-TOF-MS). Organic phase soluble Aqueous phase soluble Polystyrene Polyethylene oxide (PEO) Polymethyl methacrylate Polyacrylic acid Polybutadiene Polystyrene sulfonic acid Polyisoprene Polystyrene sodium sulfonate The polymer standards are available either individually (in the widest range of molecular weights) or as kits containing wide range of M n. Care has been taken to develop standards with the narrowest molecular weight distribution to ensure reliable calibrations of the instruments or for basic research. A Certificate of analysis that accompanies each product provides the characterization information indicating the type of end groups and microstructure of the polymer. Purification of Polymer samples: Purification of the polystyrene catalyst by following steps: was carried out rigorously to ensure the removal of the 1. Dissolved the polymer in CHCl3 and washed with water to remove insoluble organic catalyst as side product. 2. Polymer solution in chloroform filtered and passed through a column packed with basic Al2O3. 3. Solution was concentrated on rota-evaporator 4. Concentrated solution precipitated in cold methanol. 5. Dried under vacuum for 48h at 38 o C. Further, dissolved in dioxane; filter, and freeze dried under vacuum. 6. Polymer was packed in a clean vial in dust free environment. 2

Characterization techniques Gel Permeation or Size Exclusion Chromatography Gel permeation chromatography (GPC) also known as size exclusion chromatography (SEC) is employed to obtain number average molecular masses (M n ) and weight average molecular weight (M w ). Both these values result to obtain polydispersity index (PDI) (PDI=M w /M n ). It guides the application level of reference polymers. SEC analysis was performed on a Varian liquid chromatograph equipped with refractive and UV light scattering detectors. Three SEC columns from Supelco (G6000-4000-2000 HXL) were used with a dual detector model 270 from Viscotek Co connected on line in series with columns. Low angle and at 90 o light scattering were used to determine absolute molecular weights of the polymer. Average molecular weight by weight: M w w M i w i i Average molecular weight by number: M n ni M n i i where: w i is the weight in fraction i; n i is the molecular number in fraction i. M i is the molecular weight of fraction i. M i wi n i Due to some polymer chains distribution in polymer sample, weight average molecular weights (Mw) is always greater than number average molecular weights (Mn). The index of Mw/Mn determine the molecular distribution (polydispersity: PDI) is introduced. M w PI M n 3

Detector Response (mv) If PI=1, all the chain lengths are same. Usually, the sample prepared by living process is of narrow distribution character, the PI should be less than 1.15. Mp is the molecular weight at peak maximum. Intrinsic viscosity [ ] is the related viscosity exploited to concentration = 0, which is related to solvent and temperature. The molecular shape is important to the intrinsic viscosity. When molecular weight is same, the [ ] of multi-arm (four- or six-arm) polymer is much lower than that of linear one. Radius of Gyration (Rgw): the size of macromolecule. Infrared spectrum will give us the difference in the samples qualitatively, due to the sensibility to impurities. The three samples are chemical identical, as well as the functionality range. It is worth to note that all the results listed here might have about ±5% deviation. Polymers were characterized using a fully integrated GPC instrumentation (combining refractive index detectors with static light scattering detectors and viscometers) and complete software packages. A typical combined SEC of a reference polymer having M n of 90000 dalton is shown below: 162.0 135.0 17.05 Refractive Index Right Angle Light Scattering Low Angle Light Scattering Viscometer DP 108.0 81.0 54.0 27.0 0.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 22.0 24.0 26.0 Retention Volume (ml) 4

6.00 5.80 5.60 5.40 5.20 Log Molecular Weight vs. Retention Volume 65.15 58.64 52.12 45.61 39.09 WF / dlog M vs. Log Molecular Weight 32.58 4.80 26.06 4.60 19.55 4.40 13.03 4.20 4.00 16.0 17.0 18.0 19.0 20.0 6.52 MnMz Mw 4.0 5.0 6.0 Typical SEC of Reference Materials Polystyrene (PS) Gel permeation chromatography (GPC) of polystyrene M w ranging from oligomers to 10 millions are shown below. SEC of selected polystyrene standard 0.4 0.2 PS 0.5k PS 2k PS 5k PS 10k PS 30k PS 100k PS 300k PS 500k PS 1000k PS 2000k PS 5000k PS 10000k 0.0 15 18 21 24 27 30 Ve (ml) 5

Polystyrene standard samples Part No. Lot No. M n M w M p [ ] in M w/m n PS 0.5K P8092-S 500 600 620-1.2 PS 1K P8094-S 950 1140 950-1.2 PS 2K P8095-S 1900 2185 2000-1.15 PS 5k P2444-S 5,522 5,910 5,770 0.1176 1.07 PS 12k P5811-S 12,800 13,800 13,300 0.2021 1.07 PS 21k P486-S 21,000 23,000 21,000 0.2828 1.09 PS 55K P8647-S 54,500 59,300 59,100 0.5458 1.08 PS 100k P8070-S 99,000 105,000 100,500 0.8260 1.06 PS 235K P5712-S 235,000 256,000 241,500 1.5880 1.09 PS 420K P4699-S 419,000 444,000 419,500 2.4270 1.06 PS 600K P2577-S 600,000 643,000 632,500 2.8360 1.07 PS 820K P5654-S 820,000 878,000 880,000 3.8860 1.07 PS 5,000K P1104-S 5,000,000 6,500,000 5,800,000 1.30 PS 6,500K P1105-S 6,500,000 8,200,000 7,600,000 1.25 PS 7,600k P1099-S 7,600,000 9,300,000 8,800,000-1.22 Prices 15 polystyrene reference material 500mg each US$ 100 15 polystyrene reference material 1,000mg each US$ 140 6

Characterization report for the each sample analysis: PS: 500 lot P8092-S Part No. Lot No. M n M w M p [ ] in M w/m n PS 0.5K P8092-S 500 600 620-1.2 P8092-S dn -0 8 10 12 14 16 18 20 22 24 26 28 30 32 Ve (ml) Size Exclusion Chromatography of polystyrene M n =500, M w =600, M w /M n =1.20 Mn by HNMR: 550 7.356 7.348 7.341 2.480 2.466 2.453 1.945 1.932 1.917 0.930 P8092-S 1.08 1.94 0.96 10.0 ppm (f1) 5.0 0.0 7

Part No. Lot No. M n M w M p [ ] in M w/m n PS 1K P8094-S 950 1140 1050-1.2 P8094-S dn -0 8 10 12 14 16 18 20 22 24 26 28 30 32 Ve (ml) Size Exclusion Chromatography of polystyrene M n =950, M w =1400, Mp: 1050 M w /M n =1.20 Mn by HNMR: P8094-S 0.64 2.08 1.05 10.0 ppm (f1) 5.0 0.0 8

Part No. Lot No. M n M w M p [ ] in M w/m n PS 2K P8095-S 1900 2185 2000-1.15 P8095-S dn -0 8 10 12 14 16 18 20 22 24 26 28 30 32 Ve (ml) Size Exclusion Chromatography of polystyrene M n =1900, M w =2200, M w /M n =1.19 Mn by HNMR: 1700 P8095-S 0.38 3.28 10.0 ppm (f1) 5.0 0.0 9

Log Molecular Weight Cumulative Weight Fraction Part No. Lot No. M n M w M p [ ] in M w/m n PS 5k P2444-S 5,522 5,910 5,770 0.1176 1.07 Sample ID: P2444-S Concentration Sample dn/dc Method File Column Set System 2.1713 0.1850 PS80-Jan192011-0000.v cm 3x PL 1113-6300 Sy stem 1 2 21.33 22.67 24.00 25.33 26.67 28.00 29.33 30.67 32.00 33.33 34.67 36.00 37.33 38.67 4 Sample Mn Mw Mp Mw/Mn IV Rh 2011-03-29_16;44;25_P2444-S_01.v dt5,522 5,909 5,771 1.070 0.1176 2.89 4.67 0.84 0.70 1.00 0.83 4.33 0.56 0.67 4.00 0.42 0.50 3.67 0.28 0.33 3.33 3.00 0.14 0.17 34.11 34.54 34.96 35.39 35.81 36.24 36.67 37.09 37.52 37.94 38.37 38.80 2011-03-29_16;44;25_P2444-S_01.vdt: Log Molecular Weight Cumulative Weight Fraction 10

Log Molecular Weight Cumulative Weight Fraction Part No. Lot No. M n M w M p [ ] in M w/m n PS 12k P5811-S 12,800 13,800 13,300 0.2021 1.07 Sample ID: P5811-S Concentration Sample dn/dc Method File Column Set System 1.6279 0.1850 PS80-Jan192011-0000.v cm 3x PL 1113-6300 Sy stem 1 2 21.33 22.67 24.00 25.33 26.67 28.00 29.33 30.67 32.00 33.33 34.67 36.00 37.33 38.67 4 Sample Mn Mw Mp Mw/Mn IV Rh 2011-03-29_17;45;28_P5811-S_01.v dt12,864 13,787 13,320 1.072 0.2021 4.58 6.00 5.50 0.92 0.77 1.00 0.83 0.61 0.67 4.50 0.46 0.50 4.00 0.31 0.33 3.50 3.00 0.15 0.17 32.94 33.41 33.88 34.35 34.82 35.29 35.76 36.23 36.70 37.17 37.64 38.11 2011-03-29_17;45;28_P5811-S_01.vdt: Log Molecular Weight Cumulative Weight Fraction 11

Log Molecular Weight Cumulative Weight Fraction Part No. Lot No. M n M w M p [ ] in M w/m n PS 21k P486-S 21,000 23,000 21,000 0.2828 1.09 Sample ID: P489-S Concentration Sample dn/dc Method File Column Set System 1.4288 0.1850 PS80-Jan192011-0000.v cm 3x PL 1113-6300 Sy stem 1 2 21.33 22.67 24.00 25.33 26.67 28.00 29.33 30.67 32.00 33.33 34.67 36.00 37.33 38.67 4 Sample Mn Mw Mp Mw/Mn IV Rh 2011-03-29_18;46;30_P489-S_01.v dt 20,860 23,018 22,129 1.103 0.2818 6.06 4.67 0.71 0.59 1.00 0.83 4.33 0.47 0.67 4.00 0.35 0.50 3.67 0.24 0.33 3.33 3.00 0.12 0.17 31.70 32.19 32.67 33.16 33.65 34.13 34.62 35.11 35.59 36.08 36.57 37.05 2011-03-29_18;46;30_P489-S_01.vdt: Log Molecular Weight Cumulative Weight Fraction 12

Log Molecular Weight Cumulative Weight Fraction Part No. Lot No. M n M w M p [ ] in M w/m n PS 55K P8647-S 54,500 59,300 59,100 0.5458 1.08 Sample ID: P8647-S Concentration Sample dn/dc Method File Column Set System 1.4364 0.1850 PS80-Jan192011-0000.v cm 3x PL 1113-6300 Sy stem 1 2 21.33 22.67 24.00 25.33 26.67 28.00 29.33 30.67 32.00 33.33 34.67 36.00 37.33 38.67 4 Sample Mn Mw Mp Mw/Mn IV Rh 2011-03-29_19;47;33_P8647-S_01.v dt54,275 59,358 59,077 1.094 0.5458 10.37 6.00 5.67 0.77 0.64 1.00 0.83 5.33 0.51 0.67 0.38 0.50 4.67 0.26 0.33 4.33 4.00 0.13 0.17 30.58 31.06 31.55 32.03 32.51 33.00 33.48 33.96 34.45 34.93 35.41 35.90 2011-03-29_19;47;33_P8647-S_01.vdt: Log Molecular Weight Cumulative Weight Fraction 13

Log Molecular Weight Cumulative Weight Fraction Part No. Lot No. M n M w M p [ ] in M w/m n PS 100k P8070-S 99,000 105,000 100,500 0.8260 1.06 Sample ID: P8070-S Concentration Sample dn/dc Method File Column Set System 1.3054 0.1850 PS80-Jan192011-0000.v cm 3x PL 1113-6300 Sy stem 1 2 21.33 22.67 24.00 25.33 26.67 28.00 29.33 30.67 32.00 33.33 34.67 36.00 37.33 38.67 4 Sample Mn Mw Mp Mw/Mn IV Rh 2011-03-29_20;48;35_P8070-S_01.v dt98,636 105,753 100,489 1.072 0.8261 14.44 6.00 5.67 0.91 0.76 1.00 0.83 5.33 0.61 0.67 0.45 0.50 4.67 0.30 0.33 4.33 4.00 0.15 0.17 28.66 29.21 29.76 30.31 30.86 31.41 31.97 32.52 33.07 33.62 34.17 34.72 2011-03-29_20;48;35_P8070-S_01.vdt: Log Molecular Weight Cumulative Weight Fraction 14

Log Molecular Weight Cumulative Weight Fraction Part No. Lot No. M n M w M p [ ] in M w/m n PS 235K P5712-S 235,000 256,000 241,500 1.5880 1.09 Sample ID: P5712-S Concentration Sample dn/dc Method File Column Set System 0.7563 0.1850 PS80-Jan192011-0000.v cm 3x PL 1113-6300 Sy stem 1 2 21.33 22.67 24.00 25.33 26.67 28.00 29.33 30.67 32.00 33.33 34.67 36.00 37.33 38.67 4 Sample Mn Mw Mp Mw/Mn IV Rh 2011-03-29_21;49;39_P5712-S_01.v dt234,906 256,362 241,320 1.091 1.5881 24.03 7.00 6.67 0.84 0.70 1.00 0.83 6.33 0.56 0.67 6.00 0.42 0.50 5.67 0.28 0.33 5.33 0.14 0.17 27.39 27.83 28.26 28.69 29.12 29.56 29.99 30.42 30.85 31.29 31.72 32.15 2011-03-29_21;49;39_P5712-S_01.vdt: Log Molecular Weight Cumulative Weight Fraction 15

Log Molecular Weight Cumulative Weight Fraction Part No. Lot No. M n M w M p [ ] in M w/m n PS 420K P4699-S 419,000 444,000 419,500 2.4270 1.06 Sample ID: P4699-S Concentration Sample dn/dc Method File Column Set System 0.7491 0.1850 PS80-Jan192011-0000.v cm 3x PL 1113-6300 Sy stem 1 2 21.33 22.67 24.00 25.33 26.67 28.00 29.33 30.67 32.00 33.33 34.67 36.00 37.33 38.67 4 Sample Mn Mw Mp Mw/Mn IV Rh 2011-03-29_22;50;40_P4699-S_01.v dt418,563 443,977 419,305 1.061 2.4272 33.29 7.00 6.67 0.85 0.71 1.00 0.83 6.33 0.57 0.67 6.00 0.42 0.50 5.67 0.28 0.33 5.33 0.14 0.17 24.52 25.21 25.91 26.60 27.29 27.98 28.67 29.36 30.05 30.74 31.43 32.12 2011-03-29_22;50;40_P4699-S_01.vdt: Log Molecular Weight Cumulative Weight Fraction 16

Part No. Lot No. M n M w M p [ ] in M w/m n PS 600K P2577-S 600,000 643,000 632,500 2.8360 1.07 Sample ID: P2577-S Concentration (mg/ml) Sample dn/dc Method File Column Set System 2.0014 0.1850 PS80-Jan192011-0000.v cm 3x PL 1113-6300 Sy stem 1 2 22.00 24.00 26.00 28.00 3 32.00 34.00 36.00 38.00 4 Sample Mn (Daltons) Mw (Daltons) Mp (Daltons) Mw/Mn IV 2011-04-25_15;47;16_P2577-S_01.v dt 600,650 643,453 632,760 1.071 2.8360 24.00 24.59 25.19 25.79 26.38 26.98 27.58 28.17 28.77 29.37 29.96 30.56 31.16 31.75 32.35 32.95 2011-04-25_15;47;16_P2577-S_01.vdt: Log Molecular Weight Cumulative Weight Fraction 17

Log Molecular Weight Cumulative Weight Fraction Part No. Lot No. M n M w M p [ ] in M w/m n PS 820K P5654-S 820,000 878,000 880,000 3.8860 1.07 Sample ID: P5654-S Concentration Sample dn/dc Method File Column Set System 0.9829 0.1850 PS80-Jan192011-0000.v cm 3x PL 1113-6300 Sy stem 1 2 21.33 22.67 24.00 25.33 26.67 28.00 29.33 30.67 32.00 33.33 34.67 36.00 37.33 38.67 4 Sample Mn Mw Mp Mw/Mn IV Rh 2011-03-30_00;52;45_P5654-S_01.v dt820,377 877,812 880,203 1.070 3.8873 49.07 7.00 6.67 0.56 0.47 1.00 0.83 6.33 0.37 0.67 6.00 0.28 0.50 5.67 0.19 0.33 5.33 0.09 0.17 23.46 24.20 24.94 25.68 26.42 27.16 27.90 28.64 29.38 30.12 30.86 31.60 2011-03-30_00;52;45_P5654-S_01.vdt: Log Molecular Weight Cumulative Weight Fraction 18

Part No. Lot No. M n M w M p [ ] in M w/m n PS 5,000K P1104-S 5,000,000 6,500,000 5,800,000 1.30 PS 6,500K P1105-S 6,500,000 8,200,000 7,600,000 1.25 PS 7,600k P1099-S 7,600,000 9,300,000 8,800,000-1.22 PS of 5.0M ; 6.5M and 7.6M 7M 6M 5M 0.0 Ve (ml) 20 Polystyrene, of molecular weights of 5,000,000; 6,500,000 and 7,600,000 19