SILENT10 PORTABLE AIR CONDITIONER USER MANUAL



Similar documents
Platinum Range PLAC12000HP PORTABLE AIR CONDITIONER WITH HEAT PUMP USER MANUAL HIGH MID COLL HEAT DRY FAN LOW F C TIMER SLEEP SWING

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Portable Air Conditioner

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

PORTABLE AIR CONDITIONER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Important Safeguards

Meaco 30L and Meaco 40L dehumidifier instruction manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

PORTABLE AIR CONDITIONER (LOCAL)

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Air Conditioner. Portable BTU/h 2.9kW INSTRUCTION MANUAL CWAC11 CPIN Important! Please read these instructions carefully.

PORTABLE AIR CONDITIONER

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Room Air Conditioners

Get Me Cool Now Portable Air Conditioner User s Manual

Instruction manual for Firstline FCS12000CH

Operating Instructions Air Conditioner

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Operating Instructions Split System Air Conditioner

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

Dehumidifier Users manual. For Models: DH45S DH65S

SAFEGUARDING THE ENVIRONMENT

USER S MANUAL HSC-24A

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Portable Air Conditioner INSTRUCTION MANUAL

Split Type Room Air Conditioner. KSWM units

Room Air Conditioners

Climax Air Inc. DC Inverter Portable Air Conditioner Model VS12 12,000 BTU Introducing The World s Most Efficient Portable Air Conditioner

PORTABLE AIR CONDITIONER

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

Operating Instructions Air Conditioner

LUCCI AIRFUSION QUEST II CEILING FAN

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Meaco 10L Basic Small Home Dehumidifier

Room Air Conditioners

Portable Air Conditioner

Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER

R410A SPLIT SERIES DC INVERTER

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Taurus Series YORK Window Air Conditioners

FOXAIR 60/50 ALL MODELS

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

WINDOW ROOM AIR CONDITIONER

Portable Evaporative Air Cooler with Heater for indoor use. OWNER S MANUAL Read and save these instructions before use.

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

- 2 - IMPORTANT SAFETY REMINDERS

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

OPTIONAL SLENDER REMOTE CONTROL

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

ALL IN ONE. Heat Pump Water Heater

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Contents. PREPARING YOUR AIR CONDITIONER Safety Precautions... 3 View of the Indoor unit... 8

2-SLICE COOL TOUCH TOASTER

INDOOR UNIT/OUTDOOR UNIT

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

CARING FOR YOUR WATER HEATER

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Carpet Washer. vax.co.uk. Rapide Ultra series

Split Air Conditioner

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

PORTABLE AIR CONDITIONER CLIMATISEUR PORTATIF ACONDICIONADOR DE AIRE PORTATIL

VACUUM CLEANER INSTRUCTION MANUAL

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

OWNER S MANUAL SPLIT SYSTEM AIR CONDITIONER. G Series Cooling

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

Split Air Conditioner

OPERATING MANUAL ASSEMBLY. Remote control docks magnetically. click. until it clicks and locks. REGISTER YOUR FREE 2 YEAR GUARANTEE TODAY

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

SYSTEM Inverter Air Conditioners

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

DUCT TYPE AIR CONDITIONER

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Single Zone LCD Thermostat Operating Instructions

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Reverse Cycle Inverter Split System Air Conditioner

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Meaco DD8L desiccant dehumidifier Instruction Manual

Transcription:

SILENT10 PORTABLE AIR CONDITIONER USER MANUAL Thank you for choosing ElectriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our page www.electriq.co.uk for our entire range of Intelligent Electricals

CONTENTS 1.SAFETY INSTRUCTIONS.. 3 2.FEATURES AND PARTS LIST... 4 3.INSTALLATION.. 5 4.OPERATION AND SETTINGS.. 7 5.WATER-DRAINAGE. 9 6.MAINTENANCE 10 7.TROUBLE SHOOTING.. 11 8.APPENDIX. 12 Page 2 of 13

SAFETY INSTRUCTIONS Important! Carefully read the instructions before operating the unit This appliance is for indoor use only. Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. Installation must be in accordance with regulations of the country where the unit is used. If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician. This air conditioner has been tested and is safe to use. However, as with any electrical appliances - use it with care. Disconnect the power plug from socket before dismantling, assembling or cleaning. Avoid touching any moving parts of the appliance. Never insert fingers, pencils or any other objects though the guard This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Do not leave children unsupervised with this appliance. Do not clean the unit by spraying it or immersing it in water. Never connect the unit to an electrical outlet using an extension cord. If an outlet is not available, one should be installed by a qualified electrician. Never operate this appliance if the cord or plug is damaged. Ensure the power cord is not stretched or exposed to sharp object/edges. A damaged supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard. Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to comply could result in a voided warranty. Do not use the appliance for any other purposes than its intended use. The air conditioner unit must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit. Avoid restarting the air conditioning unit unless 3 minutes have passed since being turned off. This prevents damage to the compressor. Never use the mains plug as a switch to start and turn off the air conditioning unit. Use the provided ON/OFF switch located on the control panel. Always place the unit on a dry and stable surface. The appliance should not be installed in laundry or wet rooms Energy Saving and Unit Safety Protection Tips Do not cover or restrict the airflow from the outlet or inlet grills. For maximum performance the minimum distance from a wall or objects should be 50cm. Keep the filters clean. Under normal conditions, filters should only need cleaning once every three weeks (approximately). Since the filters remove airborne particles, more frequent cleaning maybe necessary, depending on the air quality. For the initial startup set the fan speed to maximum and the thermostat to 4-5 degrees lower than the current temperature. After, set the fan switch to low and set the thermostat to your desired setting. To protect the unit we recommend not using the cooling function when the ambient temperature is higher than 35⁰C. Page 3 of 13

FEATURES AND PARTS LIST 1. Features Self-evaporative system - no external water tank needed Designer inspired luxury model Bright LED screen, indicates temperature and operation mode On/Off timer function allows you to choose when the unit operates Compressor protection technology 2. Parts list: 1. Control Panel 6. Exhaust Connector 2. Air Outlet 7. Lower Filter Frame 3. Fan Blade 8. Rubber Stopper 4. Castors 9. Drain Plug Cap 5. Upper Filter Frame 10. Power Cord Accessories: 1. Extendable Window Kit 4. Hose Connector 2. Screw, Washer, Nut (for window kit) 5. Remote control 3. Extendable Exhaust Hose (~1.5m) Page 4 of 13

Installation INSTALLATION Warning:Before using this unit, please keep it upright for at least 3-4 hours. This unit can easily be moved from one room to another. While moving the unit please note that it must always be kept upright and then placed on an even surface. 1. Assemble the fishtail connector on to the hose 2. Assemble the exhaust hose to the air conditioner body Extend one head of the hose and screw it into the unit anti-clockwise. The hose can be removed by screwing the hose clockwise. Note: to screw it into place should take no less than three rotations. 3. In the same way connect the hose to the assembled adaptor (at least three rotations) 4. Installation of window kits: Partially open the window and then fix the window kit to the window Page 5 of 13

5. Make sure the unit is upright and there are no obstructions to the air inlets and outlet grills 6. Fix the other end of the hose to the air-outlet window kit Note: The window kit is only designed to be installed with sliding or sash windows or doors. The window kit is not designed or to be used with any other style of windows. However the fish tail adaptor can be used with most windows / doors. When using the cooling mode ensure that the opening left is as small as possible. The best form of installation is through a wall duct. By properly venting you expel hot air from your room while efficiently cooling it. Important safeguards The length of the soft hose extends from 28 cm to 150 cm. If hose is extended above this length the unit may malfunction and this can invalidate the warranty. The outlet vent must be well ventilated and not obstructed as this will cause the unit to overheat. Avoid bending the air hose more than 30 degrees. Page 6 of 13

OPERATION AND SETTINGS This portable air conditioner boasts 3 functions: cooling, dehumidifying and fan. The fan has two speeds: high and low. Temperature range settings are: 16-31 ⁰ C The unit will also display operating function, temperature, fault diagnostic and protective functions on the LCD screen. 1. Control instruction: Control panel: 1.1 When plugged in the unit is automatically in standby status. 1.2 ON/OFF button: Press this button to turn the unit on and enter cooling mode. The unit will be turn to cooling mode preset to 22⁰C target temperature. Press again and the unit will switch off. 1.3 Mode button Press this key to choose Cooling Fan, or Dehumidifying Mode. 1.4 Fan button a) In Fan and Cooling mode: HIGH( ) LOW( ) b) In Dehumidifying mode, the fan is auto set to low speed and cannot be changed 1.5 Timer Press the icon to select your desired operating times. Use the and buttons to adjust hours from 1-24. You can only set the auto-shut off timer while the unit is operating (on) You can only set the auto-start timer while the unit is switched off (standby) After you have set the timer the timer will initiate and the units will start/ stop after the selected time. If you adjust the timer or press the power key previous settings will be cleared. Timer functions cannot be combined or repeated. 1.6 Up and Down button: set temperature and timer. In cooling mode, the temperature can range from 16-31⁰C. Timer is 1-24 hrs. Pressing and buttons simultaneously, shifts between ⁰C and. Page 7 of 13

1.7 Sleep mode key : In cooling mode, press the key and the unit will go into sleeping mode. Press again to cancel. It increases the target temperature with 1⁰C after an hour and readjust to 2⁰C increase after 2 hours. Sleep mode is not operational under dehumidification and fan only mode. 1.8 Swing button : press this key to start auto swing function left to right, press again to cancel. Stopping the swing will lock the louvres position. 2. Remote control 1.Power :Press this key to turn the unit on/off. 2. Timer :Press this key to set time. Once set, selected time will flash 5 times as confirmation 3. Down :Press this key to turn down the temperature or adjust time. 4. Mode :Press this key to choose cooling, heating, dehumidifying or fan mode 5. Up :Press this key to turn up the temperature or adjust time. 6. Fan :Press this key to set low/medium/high fan speed. 7. Sleep (Only in cooling function):press this key to enable sleep mode. 8. Swing :Press this key to control swing function. 3. Multi protective function 3.1 Anti-freezing protecting control: When the ambient temperature is low while in Cooling Mode, the compressor and water motor will stop working if the copper coil temperature reaches <2⁰C for over 20 seconds. When the copper coil temperature increases to >8⁰C, the protection will be stopped automatically. 3.2 Water-full protection: When the water level in the internal water tank is surpassing the maximum level, the unit will alert automatically and main led light will flash. Please discharge water in the machine according to Water Drainage section Page 8 of 13

3.3 Compressor delay-protection Except for the first power-on, the compressor can start instantly. The compressor also runs under a 3 minute delay protection function. 3.4 Compressor protection In cooling, dehumidifying and heating mode, if the temperature difference between the coil temperature and room temperature is less than 3⁰C, for more than 30 minutes, the machine will enter no refrigerant compressor protection mode. The compressor and water spring motor will stop working. The up fan runs at low speed and the down fan stops running WATER-DRAINAGE 1. Manual drainage: 1.1 When the internal water tank is full the unit will stop working. 1.2 Shut off the unit and unplug. Try not to move the model abruptly as this may cause water to spill out from internal water tank. 1.3 Place a tray under the water plug. 1.4 Screw off the drain plug and unplug the water rubber stopper - water will drain from the container. 1.5 Put the water rubber stopper back and screw the drain plug cap back into place 2. Continuous drainage: 2.1 Screw off the drain plug cap and unplug the water rubber stopper. 2.2 Use a water pipe to connect to the water outlet. 2.3 You can plumb this pipe into your current plumbing system, lead it outside or use a water pump. Note: This model has a self-evaporative function, which reduces the need to empty the water tank. If the unit is vented correctly most of the water is reused to cool the condenser coils and any excess is evaporated. Please do not use continuous drainage if you intend to use the self-evaporating facility. Page 9 of 13

Maintenance Cleaning Please shut off the unit and unplug from the mains before cleaning or performing any maintenance Clean the surface Clean the plastic housing with a duster or a soft wet cloth. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage. Air filter cleaning a) Clean the air filters every 2 weeks. If the air filter is blocked with dust, the unit s performance will be significantly affected. b) Pull out the top and bottom filters as pictured below c) Wash the air filters by immersing them in warm (about 40⁰C) water with a neutral detergent. d) Rinse it and then dry it thoroughly. e) Carefully re-install the air filters Please note: If used, the optional active carbon filter (cloth) should be replaced every 3-6 months based on the environment. End of Season Maintenance: 1. Pull out the plug from the drainage hole and empty the internal tank. You can also drain the water by leaning the unit. 2. Then switch the unit to low fan mode. 3. Keep the unit in this mode for half day - until the conduit is dried. Doing this helps to keep the inside of the unit dry and prevents mold developing 4. Turn off the unit and pull out the plug. 5. Coil the wire and bind it together, then put it into the accessories space. 6. Separate the air-exhaust pipe and store it safely. 7. Cover the unit and keep it in a dry place. 8. Take the batteries out of remote control and store or dispose, them safely Keep all accessories with the unit ready for next season. Page 10 of 13

Troubleshooting Do not repair or disassemble the unit by yourself, unauthorized repair attempts will invalidate the warranty and may cause bodily harm. Trouble Reason Solution The unit does not work The unit does not seem to perform. No power supply Water-full indicator illuminated Timer function is active Room temperature too low or too high In direct sunlight Windows or doors open. Large amount of people or a heat source in the room. Filter is very dirty Air inlet or air outlet is blocked Room temperature is lower than setting temperature Power-on and turn on the unit. Drain the internal water tank Cancel Timer function Use only in ambient temperatures between 7-40⁰C Draw the curtains, UV affects RC Close windows and turn on another air conditioner Clean or change the air filter Clear out debris Change the setting temperature The unit loud The unit is not put on flat surface Put the unit on flat and hard surface Compressor does not work Remote control doesn t work Overheating protection is active Operating distance is too far. Control panel has not received the signal from remote control. The batteries are flat Check venting. Restart the unit after 5 minutes when compressor has cooled Move remote control closer to the unit and make sure it aims at the air-outlet grille Replace the batteries E1 on LED E2 on LED Main LED light flashing Others Room temperature is abnormal Coil temperature is abnormal Water tank is full inside the machine No refrigerant or there is very little refrigerant Anti-freezing protection High pressure protection Temperature not within 5-40 C operating range. If temperature within operating range refer to Service Centre (check room temperature sensor or relevant circuit) Refer to Service Centre (check coil temperature sensor or relevant circuit) Drain out water from drain port at bottom rear of the unit. Refer to Service Centre (check leakage, wielding, vacuum pump, charge refrigerant according to name plate) Waiting for defrosting. Function will recover automatically. No user input needed. After inside gas pressure comes down, it will function normally. No user input needed If the above solutions do not resolve the problem please contact the service centre. Page 11 of 13

APPENDIX Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils. Please remember that this equipment will be further handled during the recycling process, so please be considerate when depositing your equipment. Please contact the local council for details of your local household waste recycling centres. TECHNICAL DATA: Capacity Cooling: 2.93 kwh 10,000 BTU Rated Input Cooling:1.12 kw Running Current 4.95A Air Flow 435m 3 /h EER Rating A Compressor Rotary, R410A gas Noise 38-48dB(A) Sound Energy <65dB(A) Sound Power Thermostat 16-31⁰C Moisture removal 28.8 l/day Permitted Excessive Operating 0.8/3.2MPa Pressure Maximum Allowable Pressure 1/5Mpa Power Supply 220-240V/50Hz Net Weight 25kgs Dimension(L*D*H) 360*350*750mm Unit must be vented outside when in Air Cooling and Heating mode. For the purposes of EU regulation EN12102 this is a local air conditioner and produces less than 65dB(A) sound energy. Page 12 of 13

ElectriQ UK SUPPORT www.electriq.co.uk/support Please, for your own convenience, make these simple checks before calling the service line. If the unit still fails to operate call: 0871 620 1057 or complete the online form 1. Has the unit been standing upright for at least 2 hours? 2. Is the unit plugged into the mains? 3. Is the fuse OK? 4. Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit. 5. Check if the water tank is full. Office hours: 9AM - 5PM Monday to Friday www.electriq.co.uk Unit 2, The Nursery Berristow Lane South Normanton Derbyshire, DE55 2FX Page 13 of 13