BWEA Summary Report for the C&F Green Energy Small Wind Turbine, Model No. CF20 (Phase A)



Similar documents
Letter Report No CRT-004 Project No. G


GE Renewable Energy. GE s 3 MW Platform POWERFUL AND EFFICIENT.

DIRECT MATCHING TO GRID WITHOUT INVERTER VARIABLE PITCH. 20/24/30 mt TOWER WITH HYDRAULIC SYSTEM YAWING SYSTEM SAFETY LEVELS PLC CONTROL

V kw The turbine that goes anywhere

Siemens Wind Turbine SWT The new productivity benchmark.

PMDD WIND TURBINE 1.5MW

Case Study 5 Use of Wind Turbine Technology

Excerpts from: Performance, Duration and Acoustic test reports for the Skystream 3.7 wind generator

Wind turbine database: Modelling and analysis with focus on upscaling. Master s thesis in the Master programme Applied Mechanics

Nordex SE. Capital Markets Day Products & Sales - Lars Bondo Krogsgaard

Wind Turbines - Biggest 5G Turbine Market Ever

ENERCON WIND TURBINES

Libellula 50/55 kw WIND TURBINE TECHNICAL DESCRIPTION

V MW. Your best option for low cost energy production at low and medium wind sites. Federico Gonzalez Vives. Director Technology.

V MW Making wind even more profitable

V MW & V MW (OFFSHORE)

Outline. Introduction to Wind Energy. US Wind Energy Installations. ME 483 Alternative Energy Engineering II 1

Kestrel Small Wind Turbines in Schools

GE Power & Water Renewable Energy. Digital Wind Farm THE NEXT EVOLUTION OF WIND ENERGY.

Wind Turbine Technology Overview

WIND TURBINE TECHNOLOGY

Sweden s leading manufacturer of small-scale wind power stations!

Some scientific challenges in aerodynamics for wind turbines

WWD-1 1 MW wind turbine

AERODYNAMIC ANALYSIS OF BLADE 1.5 KW OF DUAL ROTOR HORIZONTAL AXIS WIND TURBINE

Wind Turbine Design Cost and Scaling Model

Wind Energy Conversion Systems

V kw. Pitch regulated wind turbine with OptiTip and OptiSlip

Produce electricity in your own backyard.

1.0 Background 1.1 Historical background 1.2 Cost of wind turbines

Wind Turbine Power Calculations

A wind turbine for Businesses, Schools and Farms

USER MANUAL Gaia-Wind 11 kw Turbine

Development of 5-MW Offshore Wind Turbine and 2-MW Floating Offshore Wind Turbine Technology

ST. COLUMBAN WIND PROJECT WIND TURBINE SPECIFICATIONS REPORT. Stantec File No June Prepared for:

Lecture 4 Energy Conversion in Wind Turbine

Nov'turbine. Specifications. v1.1

Northern Power 100. Community Wind Turbine for Businesses, Schools & Farms

EXPERT REMANUFACTURED WIND TURBINE

ACOUSTIC TESTS OF SMALL WIND TURBINES * P. Migliore, J. van Dam and A. Huskey

SELECTION AND PERFORMANCE GENERATOR COUPLING TO VERTICAL AXIS WIND TURBINES TO URBAN APPLICATIONS

Manufactured by Seaforth Energy. The world s most proven 50 kw wind turbine

Relevance of Modern Optimization Methods in Turbo Machinery Applications

Forces on Large Steam Turbine Blades

NORDEX USA, INC. GREAT LAKES SYMPOSIUM

2.1MW PLATFORM Generations ahead

N60/1300 KW. Nordex N60 Long-term experience all over the world.

Caratteristiche tecniche

Permanent Magnetic Generator Construction Manual

Passion for Offshore. Wind Power & Renewables Division Market Unit Offshore

Physical Address: City: State: Zip Code:

EFFECTS OF COMPLEX WIND REGIMES ON TURBINE PERFORMANCE

Siemens D3 platform 3.0-MW, 3.2-MW, 3.3-MW, and 3.4-MW direct drive turbines. Reduced complexity, increased profitability. siemens.

DALLAS COUNTY, IOWA CHAPTER 48 SMALL WIND ENERGY CONVERSION SYSTEMS ORDINANCE FOR THE UNINCOPORATED AREA OF DALLAS COUNTY, IOWA

As a minimum, the report must include the following sections in the given sequence:

Wind Resource Assessment for BETHEL, ALASKA Date last modified: 2/21/2006 Compiled by: Mia Devine

ENERGY YIELD ASSESSMENT

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Siemens 6.0 MW Offshore Wind Turbine

Configuration study of large wind parks

Application Information

Sound Power measurements according to IEC

How Noise is Generated by Wind Turbines The mechanisms of noise generation. Malcolm Hayes Hayes McKenzie Partnership Ltd Machynlleth & Salisbury

Engineering for life Wind generation

MCS 020. MCS Planning Standards. For permitted development installations of wind turbines and air source heat pumps on domestic premises

The Reliance on Wind Energy Depends on Advancements in Blade Pitch Control

Simplified Design as Secret to higher Performance: Siemens Direct Drive Technology

SYNCHRONOUS MACHINES

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

A Residential Example of Hybrid Wind-Solar Energy System: WISE

windera s PRODUCT MANUAL

PM734F - Technical Data Sheet Winding 28

Figure. 1 - Split Phase 240/120V circuit (180 phase shift)

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

The DTU 10-MW Reference Wind Turbine

MODEL ORDINANCE FOR WIND ENERGY FACILITIES IN PENNSYLVANIA. This Ordinance shall be known as the Wind Energy Facility Ordinance for [municipality].

Onshore Wind Services

Motor Fundamentals. DC Motor

Brochure. Generators for wind power Proven generators reliable power

UCI274C - Technical Data Sheet

UCI274H - Technical Data Sheet

GE Energy 1.5MW. Wind Turbine

DELTA GENERATION PROVEN TECHNOLOGY AT A NEW STAGE OF EVOLUTION N100/3300 N117/3000 N131/3000

Renewable Energy Applications: Photovoltaic and Wind Energy Conversion Systems (WECS)

Modeling Grid Connection for Solar and Wind Energy

Wind Electrolysis: Hydrogen Cost Optimization

Design and Characterization of a Small Wind Turbine Model equipped with a Pitching System

SUSTAINABLE TECHNOLOGY

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Upwind 20MW Wind Turbine Pre- Design

PowerSpout Technical Specifications. PowerSpout PLT, TRG and LH

WIND POWER GENERATION TECHNOLOGY Mrs. N.V. Vader Mrs. V.A. Joshi

THE COMPOSITE DISC - A NEW JOINT FOR HIGH POWER DRIVESHAFTS

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PowerFlex Dynamic Braking Resistor Calculator

London Array Off-Shore Wind Farm

C Standard AC Motors

Transcription:

Cleeve Road, Leatherhead Surrey, KT22 7SB UK Telephone: +44 (0) 1372 370900 Facsimile: +44 (0) 1372 370999 www.intertek.com BWEA Summary Report for the C&F Green Energy Small Wind Turbine, Model No. CF20 (Phase A) Report No. : 102155353LHD-003a Date Issued : 22 June 2015 Date Revised : None Client : Mr Enda Meaney C&F Green Energy Ltd Cashla, Athenry Co. Galway Republic of Ireland Phone: +353 91 790 868 Email: enda.meaney@cfgreenenergy.ie Prepared by : Nick Jones Reviewed by : Kevin Sweeney Title : Consultant Engineer Title : Business Development Director Signature : Signature : This report is for the exclusive use of Intertek s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek s responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only the sample tested. This report by itself does not imply that the material, product or service is or has ever been under an Intertek certification program. Intertek Testing and Certification Ltd Page 1 of 7

1 Summary The purpose of this report is to provide a summary of test results in accordance with the British Wind Energy Association Small Wind Turbine Performance and Safety Standard, 29 February 2008. The results contained in this summary report have been taken from the following test reports: Document Reference Report Title Date 101722994LHD-002 102155353LHD-001 101722994MKS-001 101129165LHD-008a Power Performance Testing of C&F Green Energy Small Wind Turbine, Model No. CF25 (Phase A) Power Performance of C&F Green Energy Small Wind Turbine, Model Nos. CF20, CF19.5, CF15 & CF11 Acoustic Noise Emission Test Report for the C&F Green Energy Wind Turbine Generator System Strength and Safety Report for C&F Green Energy Small Wind Turbine, Model No. CF25 (Phase A) 26-May-2015 22-Jun-2015 21-May-2015 09-Jan-2014 This investigation was authorized by signed proposal number 500604492, dated 02 June 2015. If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact the signatories on this report. Please note, this report on its own does not represent authorization for the use of any Intertek certification marks. 2 Revision History Date Revised By Description of Changes 22-Jun-2015 - None new report Intertek Testing and Certification Ltd. Page 2 of 7

C&F Green Energy 3 Description of the wind turbine The CF20 is designed for grid-connected power delivery, with a manufacturer s declared rated power output of 20 kw. The CF20 is a horizontal axis machine with a 3-blade upwind rotor with active speed and power control through active blade pitch actuation and turbine yaw control. The CF20 has a three-phase permanent magnet variable-speed generator directly coupled to the rotor, the output of which is fully converted in the inverter. The inverter output is configured for connection to three-phase split-phase or single-phase electrical networks with nominal operating voltage of 230 V phase to neutral at 50 hz. Overspeed protection is provided by disc brake on the main shaft. The nacelle is mounted on a self-supporting steel monopole tower which is hinged to permit lowering of the nacelle for installation and maintainence. This machine is based on the CF25 (Phase A) but with the power output restricted to 20 kw by means of speed reduction and inverter programming. Figure 2: C&F Green Energy CF20 Wind Turbine Intertek Testing and Certification Ltd. Page 3 of 7

A summary of the test turbine configuration and manufacturer s declared ratings can be found in Table 2 below. Table 2: Turbine Characteristics Manufacturer : C&F Green Energy Model No. CF20 (Phase A) Description: Rotor Diameter : Rotor Swept Area : 134.8 m³ Number of Blades : 3 Hub Height : Tower : Rated Power : Rated Wind Speed : Wind Class : Survival Wind Speed : Cut-in Wind Speed : Cut-out Wind Speed : Rotor Speed Range : Low Speed Shaft Speed : Speed Reduction Method : Yaw Control : Blade Pitch Control : Blades specification : Blade Identification : Generator Type : Generator Identification : Power Conversion : Inverter Type : Inverter Software : Grid Protection Method : Grid Protection Type : Turbine Controller : Turbine Controller Software : Nominal Network Conditions : Horizontal axis wind turbine with active blade pitch and active yaw 13.1 m (verified be measurement) 15.35 m Tubular steel monopole (not guyed) 20 kw (nominal) 13.0 m/s II (Vave = 8.5 m/s) 70 m/s 2.2 m/s 25 m/s 0-85 rpm (normal operating range) N/A (generator runs at Rotor speed) N/A Active Active Drawing no. B-0406-G Closed mould infusion of glass-filled vinylester resin over a polyurethane foam core with double spar, 7 twist from root to tip, airfoil geometry based on NACA 5415 Blade set no. CFGE-BS-6-0566, individual blade serial nos. 01132025, 01132004 & 01132023 Permanent magnet, asynchronous, ac 3-phase, radial flux CFR1410H01 Solid-state inverter ELPower TL30 DSP:400, PLD:24, Ext Logic:167.07 Separate G59 relay ComAp Mainspr0 Phoenix Contact PLC-ILC-150-GSM 20KW_85RPM.csv 230 V phase to neutral, 50 hz, 3-phase, split-phase or single-phase Intertek Testing and Certification Ltd. Page 4 of 7

4 Performance Results CF20 performance at sea-level air density; 1.225 kg/m 3 Presentation of data in the measured power curve (database A) Reference air density: 1.225 kg/m 3 Bin Bin Average Wind Speed Power output Cp Number of 1- Minute Data Category A Standard Uncertainty Category B Standard Uncertainty Combined Standard Uncertainty (m/s) (m/s) (W) Sets (W) (W) (W) 1 0.61-0.100-5.51 144 0.000 0.038 0.038 2 0.97-0.099-1.35 256 0.000 0.038 0.038 3 1.46-0.098-0.40 211 0.000 0.038 0.038 4 1.98-0.097-0.16 110 0.000 0.038 0.038 5 2.55-0.097-0.07 102 0.000 0.038 0.038 6 2.96-0.003 0.00 99 0.008 0.050 0.051 7 3.49 0.443 0.13 74 0.013 0.131 0.132 8 4.00 0.827 0.16 100 0.019 0.120 0.122 9 4.53 1.772 0.24 290 0.014 0.280 0.280 10 4.99 2.649 0.27 311 0.014 0.309 0.309 11 5.51 3.504 0.26 319 0.019 0.277 0.278 12 6.00 4.683 0.27 346 0.022 0.410 0.411 13 6.50 6.374 0.29 424 0.025 0.600 0.601 14 7.01 8.053 0.29 495 0.028 0.599 0.600 15 7.49 10.948 0.32 614 0.033 1.101 1.102 16 7.99 13.368 0.33 568 0.035 0.934 0.935 17 8.50 15.581 0.32 505 0.042 0.884 0.885 18 8.98 17.328 0.30 520 0.048 0.753 0.754 19 9.49 19.727 0.29 443 0.049 1.003 1.004 20 10.0 20.000 0.25 (363) 0.072 1.125 1.128 21 10.5 20.000 0.22 0 0 0 22 11.0 20.000 0.19 0 0 0 42 21.0 20.000 0.03 0 0 0 43 21.5 20.000 0.03 0 0 0 44 22.0 20.000 0.02 0 0 0 BWEA Reference Power: 20.0 kw @ 11.0 m/s Intertek Testing and Certification Ltd. Page 5 of 7

CF20 power curve corrected to sea-level air density; 1.225 kg/m 3 The table below summarizes the estimation of expected annual energy production (AEP) at sea-level air density. CF20 Estimated annual energy production of the at sea-level air density Hub height annual average wind speed (Rayleigh) Estimated annual energy production (database A) Reference air density: 1.225 kg/m³ Cut-out wind speed: 25 m/s (extrapolation by constant power from last bin) AEP-measured (measured power curve) [note 1] Standard uncertainty in AEP [note 2] Standard uncertainty in AEP [note 2] m/s kwh kwh % 4 21959 2045 9 5 41324 2868 7 6 61284 3296 5 7 79191 3373 4 8 94011 3239 3 9 105414 3004 3 10 113384 2736 2 11 118153 2470 2 Note 1: AEP-measured assumes zero power above the range of the database (22.0 m/s). Note 2: The uncertainty figures in the above table are based on a coverage factor of 1. BWEA Reference Annual Energy: 41,324 kwh @ 5m/s Intertek Testing and Certification Ltd. Page 6 of 7

5 Acoustic Noise Measurements Noise Label Sound Power LWd,8m/s (dba) 88.4 NOISE EMISSION LEVEL ACOUSTIC NOISE LEVELS Turbine Make C & F Green Energy Ltd Model CF20 CF25 Noise Slope SdB (db/m/s) 2.65 NOISE PENALTY NO Wind Speed (m/s) 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 > 45 db 40-45 db < 40 db IMMISION NOISE MAP (Including Noise Penalty where applicable) No data recordedabove 11 m/s No data recorded below 3 m/s 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Slant Distance (m) Immission Sound Pressure Levels at 8 m/s hub height wind speed: BWEA Reference 60m Sound Level L p,60 = 44.89 dba BWEA Reference 25m Sound Level L p,25 = 52.39 dba Intertek Testing and Certification Ltd. Page 7 of 7