factor max Delivering Electrical Efficiency INFORMATION PACK factor max



Similar documents
Power factor correction. An introduction to technology and techniques

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

Metering for today s systems

Explaining How Voltage Optimisation Can Save Energy and Protect Your Site

CHAPTER 10: APPLIANCES AND LIGHTING

Energy efficiency improvement and environmental protection have ranked first priorities in utility policies, in developed and developing countries.

Improvement of Power Factor for Industrial Plant with Automatic Capacitor Bank

How To Get A Better Deal On Power From Powerline Power From Pse

Rules of Thumb Energy Efficiency in Buildings

Design Guide. Managing Peak Energy Demand In Live Performance Venues

UTILITY RATE STRUCTURE

Saving Energy For Your Organisation. Top 10 energy saving tips

At Load Power Factor Correction Phase 2: Refrigerated Vending Machines

MICRO HYDRO FOR THE FARM AND HOME

Electric Rate Book Revision: 13 ( ) Page No. 1 Effective date: SMALL COMMERCIAL

MASS SAVE ENERGY EFFICIENCY FUNDING Together we can use it wisely. Bob Dvorchik Supervisor WMECO Commercial & Industrial Energy Conservation Programs

Variable Frequency Drives and Energy Savings

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

WAYS TO SAVE ENERGY AND MONEY

Energy Audit as A Tool for Improving System Efficiency in Industrial Sector

SALT RIVER PROJECT AGRICULTURAL IMPROVEMENT AND POWER DISTRICT E-33 EXPERIMENTAL PRICE PLAN FOR SUPER PEAK TIME-OF-USE GENERAL SERVICE

Electricity Terminology. Simplifying energy management

PEND OREILLE COUNTY PUD. Quality Service at Low Cost RATES FOR ELECTRIC SERVICE

A guide to reactive power

Energy Cost Reduction through Load Balancing & Load Shedding

Gibraltar Electricity Authority ELECTRICITY (CHARGES AND TARIFFS) REGULATIONS 2010

Starting Current Reduction of Residential HVAC System and Peak-Load Impact of Power System: A Case Study

Energy Price Fact Sheet

Business Energy Efficiency. Webinar August 29, 2012

Home lighting. Bright ideas for energy savings

A SOLAR GUIDE - EVERYTHING YOU NEED TO KNOW

SCHUYLER DEPARTMENT OF UTILITIES SCHUYLER, NEBRASKA ELECTRIC RATES

EarthCents (DSM) Program Summary

POWER FACTOR CORRECTION

Power Factor Correction for Power Systems First Semester Report Spring Semester 2007

RESIDENTIAL SERVICE SCHEDULE R

Industrial Green Building Retrofit 101 Opportunities and Challenges. Light Industrial Green Building Retrofits. Why Green Retrofit?

Calculating Total Power Requirements for Data Centers

DuroSite TM High Bay Lighting

LED High bays. Peter Grumont 11/16/2012

ABB drives for water Medium voltage drives for energy savings and life-cycle improvements

UNDERSTANDING ENERGY BILLS & TARRIFS

Switching Energy Providers and PECO Smart Ideas. March 23, 2011

1. Summary. electric grid, strengthen saving programs sponsored by utilities. The project

Level 1 Energy Audit Report. For: Gladstone Regional Council

Drives and motors. A guide to using variable-speed drives and motors in data centres

Considerations in Designing Special Rates. Larry Feltner The Prime Group, LLC

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks

Commercial Energy Savings Guide.

Western Australia and the Northern Territory are not connected to the NEM, primarily due to the distance between networks.

NEW COMMERCIAL Rates. Understanding the. Commercial Customers

Bright Ideas. A Smarter Business Guide to Energy Efficiency

On-Demand Ventilation Energy Saving in Industrial Applications

Guidance for Stationary Refrigeration & Air-Conditioning

Thermal destratification in buildings: The missing piece to the HVAC puzzle

Energy Efficiency Workshops For Commercial Customers

ELECTRIC WATER HEATER CREDIT

ORDINANCE NUMBER An ordinance to establish electric utility rates in the City of Beatrice, Nebraska, in

Energy saving technology to deliver the fastest returns. Top 10 energy saving options

VendingMiser. A: VendingMiser uses three different technologies to intelligently manage the power to a vending machine.

INDUSTRIAL AUTOMATION EQUIPMENT EDITION

Consumers Energy Business Solutions. Commercial and Industrial Energy Efficiency Program April 18, 2013

Remote Maintenance with Security Appliances FL MGuard RS2000 and RS4000. Economic and Reliable Service

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

Solar. Solar Power Station. RENEWABLE MAINS-FREE POWER TECHNOLOGY INTERNATIONAL

Overview. PG&E and Energy Efficiency. CA Energy Efficiency Regulatory & Policy Roadmap. Financing Options for Efficiency & Demand Response

FACT SHEET. NEM fast facts:

Energy Saving systems for Induction motors.

TARIFF SCHEDULES FOR HIGH TENSION CONSUMERS. Table of Contents

EE 1452 ELECTRIC ENERGY GENERATION, UTILIZATION & CONSERVATION KINGS COLLEGE OF ENGINEERING

Contribution analysis of electrical energy management in the industrial and commercial sector: a challenge to the Tanzania utility industry

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Using the NI 17xx Smart Camera Direct Drive Lighting Controller

AC Power. by Prof. Dr. Osman SEVAİOĞLU Electrical and Electronics Engineering Department

The Basics of Digital Signage and Energy Consumption by Gregory Young

Statement Of Work Professional Services

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

UNDERSTANDING YOUR UTILITY BILL A GUIDE FOR BUSINESSES IN INDIANA

Cooking at the Speed of light!

TITLE PAGE MINNESOTA POWER ELECTRIC RATE BOOK

Commercial/Office Space

Electrical Systems. <Presenter>

7. Reactive energy compensation

FIXED CHARGE: This is a cost that goes towards making the service available, including

INTRODUCTION Tariff Objective Factors

TECHNICAL GUIDE A GUIDE FOR THE SELECTION OF ENERGY EFFICIENT TECHNOLOGIES

Transcription:

INFORMATION PACK Delivering Electrical Efficiency

Where innovation leads the way is a Canadian company that distributes efficient energy saving devices for commercial and industrial customers. The solutions on offer will significantly reduce your electrical energy (KVA) and Kilowatt (kwh) consumption on many common lighting and power loads. These results provide a measurable reduction of your overall business operating costs. is supported by an R & D team of over 40 engineers. Many of our sites are able to achieve a Return of Investment (ROI) of less than two years. All products are safety certified for use. Our products include a five year parts & labor warranty. The Lighting Energy Optimizer (LEO) is designed to save up to 20% of direct energy (Watts) on most types of AC electrical lighting load. Through its optimal load and supply matching technology, LEO contributes to longer lamp life by reducing heat and lowering power consumption. LEO s adaptable design will also work with most modern lighting (including many contemporary designs that have a high Power Factor) and still provide a measurable reduction in power consumption. The isaver range is available with either automatic or dynamic Power Factor correction. Our automatic range is suitable for conditions with stable loads, i.e. chillers, supermarkets and farms. Our dynamic range includes harmonic filtering and is designed for loads where rapid power fluctuations occur, i.e. CNC machine shops, tooling and metal fabrication works.

Energy efficiency is generally overlooked as an effective way for business to reduce their variable costs. isaver Energy Meter With this in mind, we created to provide installation and marketing services for a range of devices that could be installed in commercial and industrial sites and provide real savings for business owners. Every unit we sell includes a Class 1 energy meter showing realtime monitoring of consumption and savings. It also provides onboard diagnostics and communication capabilities. offers power saving solutions for virtually every customer What is the technology used by to achieve such significant savings? Our LEO unit uses an advanced energy optimization sensor that balances wattage with lumens output. LEO is able to reduce the watts consumed by an electric light without affecting the perceived brightness. The isaver is a dynamic Power Factor correction device that instantly matches the supply and demand of an electrical load. This reduces Total Electrical Power (KVA) consumption, reduces current and reactive power and enhances the efficiency of your overall power supply. Benefits of the product range Offers savings in KVA demand charges. These reduce penalties associated with reactive power. Can significantly increase the capacity of your switchgear, local network and transformers. All units are fully automatic and easy to install. All units include an integrated energy meter that enables real time monitoring of consumption and savings.

LEO LEO interior cabinet view isaver Automatic PFC isaver Dynamic PFC isaver Dynamic Interior Which 120v 347v solution is right for my business? SOLUTIONS isaver (Automatic PFC) LEO (lighting) LEO 3x50A 347v LEO 3x100A 347v APFC, isme 112 KVAR 347v APFC, isme 200 KVAR 347v APFC, isme 300 KVAR 347v DPFC isaver 150 KVAR 347v DPFC isaver 250 KVAR 347v DPFC isaver 400V KVAR 347v Dairy farms Agriculture Irrigation, water pumping isaver 70 (Automatic PFC) Processing plants Manufacturing Commercial buildings HVAC/RTU Food retailers Educational facilities Healthcare facilities Public facilities Commerical & industrial Car park buildings Recreational facilities Retail showrooms Educational facilities Healthcare facilities isme (Dynamic PFC) Machine shops Metal fabrication Tooling

Reduce the electricity consumption in public facilities by up to 25% Our electrical efficiency products reduce greenhouse gas emissions Increase pumping efficiency and reduce operating costs Reduce lighting maintenance and operating costs Frequently Asked Questions What will isaver do for me? isaver dynamic Power Factor correction can release up to 30% installed capacity, reduce your total electrical consumption by up to 25% and significantly reduce demand charges and efficiency penalties for your company. What will LEO do for me? Without noticeably affecting your light output and by targeting your lights peak efficiency, LEO will reduce KWh, immediately saving your lighting costs by 15-20%. LEO will also enable the lights to run cooler, thereby increasing their operating life. When do we see results? isaver will realise total power savings, efficiency improvement, reduced line current and reactive power as soon as the solution is turned ON. The unit s accurate digital display will detail status change in real time. Most utilities base their current month's billing on the previous month's data. It will take a full one-month billing cycle to see actual results in your billing. What is the payback period? In typical commercial/industrial environments, suitable applications can expect an ROI of less than 2 years. How does installation work? LEO and isaver installations and commissioning is taken care of by our certified technicians, all you do is sit back and save. If I have a problem with the unit, does it automatically cut off the power? isaver is designed with a fail-safe mechanism and there is no interruption in power to your premises. Is isaver a Power Factor correction device, voltage regulator or a capacitor? isaver is a dynamic power factor correction device that instantly matches the supply and demand of the electrical load. This reduces Total Electrical Power (KVA) consumption, reduces current and reactive power and enhances the efficiency of your overall power supply.

Case Studies Engineering & Metal Fabrication The client s business is a metal fabrication factory, featuring fast changing loads such as laser cutting, punching, welding and folding. These are all factors that contribute to an unbalanced electric load. The load profile was ideally suited to our isaver 70 featuring Dynamic Power Factor correction, together with 7% harmonic filtration. We were able to achieve the client's objective by improving his power quality and increase the site Power Factor from.73 to.99 and reduce the overall electricity demand charges. Model: isaver 120A (87.5 KVAR) Condition Voltage Current KVA Power Factor KVAR Frequency Without isaver 232.2 135 86.5 0.73 42.4 50 With isaver 234.6 98 68.5 0.99 0.2 50.01

Case Studies Seafood Wholesaler A frozen and fresh seafood importer, distributor and retailer runs multiple freezers, chillers and lights. The customer's objective was to optimize the installed capacity (as it was operating at close to full installed capacity) and to reduce the existing electric bill by reducing demand charges. We installed an isaver 70 with Automatic PFC. This brought his PF to.995, providing a significant reduction in the KVA, Current and KVAR, with an increase in electrical efficiency to almost 100%. This had the effect of increasing the their load capacity by approximately 12%. In addition, we added a LEO 75 which will provide a reduction in his lighting of approximately 18% KWh. Model: LEO 75A (fully operational) Parameters L1 L2 L3 VOLTAGE 231 227.6 226.8 CURRENT 6.36 5.24 0.6 KVA 1.471 1.194 0.138 KW 1.415 1.072 0.021 PF 0.962 0.895 0.156 FREQUENCY 50.02 50.01 49.98 KWH 159.45 140.06 137 SAVED KWH 34.71 27.01 31.96 SAVED % 17.88 16.17 18.84 Model: isaver 70A (50 KVAR) Condition Voltage Current KVA Power Factor KVAR Frequency Without isaver 228.9 89.8 61.5 0.86 37.3 50.01 With isaver 229.2 80.1 51.8 0.99 0.8 50.05

Case Studies Indoor Swimming School A successful swimming school with two pools, a retail store, water heating, pumping, filtration, airconditioning and lighting. We installed a LEO 75 unit to control the lighting in and outside the premises, a combination of Fluorescents and Metal Halides. Immediate savings of 17% were obtained on the full lighting load. An isaver 70 with automatic Power Factor correction was installed which immediately increased the efficiency of their mechanical pumps and motors ensuring even greater overall energy saving for the customer. Model: isaver 70 (50 KVAR) Condition Voltage Current KVA Power Factor KVAR Frequency Without isaver 233.1 136 86 0.82 38 50 With isaver 234.7 99 67.5 0.99 0.3 50.01

Case Studies Indoor Tennis Center A leading indoor tennis facility featuring both outdoor and indoor courts, a Pro Shop, a cafeteria, offices and support services. The majority of the load is lighting, primarily driven by their Metal Halide 1500 watt lamps. Their Power Factor was.89 which we increased to.991. A significant part of their bill was demand KVA based. By installing both an isaver 70 and LEO unit we have achieved their expectation of an overall saving of around 20% from their total monthly bill. Model: LEO (150 AMP fully operational) Parameters L1 L2 L3 VOLTAGE 236.5 235.9 238.7 CURRENT 20.94 25.02 24.66 KVA 4.954 5.901 5.889 KW 4.777 5.848 5.828 PF 0.965 0.992 0.992 FREQUENCY 50.09 50.11 50.11 KWH 4.95 5.58 5.8 SAVED KWH 0.66 0.7 0.88 * SAVED % 11.11 11.13 13.13 * These LEO measurements were taken 1 hour after commissioning. 24 hours later with LEO set on moderate savings, KWH % saved increased to 17% on each phase. Model: isaver 70A (50 KVAR) Condition Voltage Current KVA Power Factor KVAR Frequency Without isaver 230.3 92.84 64.4 0.891 26.7 49.98 With isaver 231.3 84 58 0.991 2.5 50.01

Case Studies Dairy Farm A medium size Dairy Farm with over 570 milking cows, a milking shed, a chiller section and an effluent treatment facility. The customer objective was to optimize the installed capacity (as it was operating at close to full installed capacity) and to reduce the existing electric bill. In this case study, after we installed the isaver 70 there was a significant reduction in the KVA, Current & KVAR, with an increase in electrical efficiency to almost 100%. This had the effect of significantly increasing the load capacity of the milking equipment. We anticipate that the penalty charges being paid for an inefficient electrical plant and a Power Factor measurement of 0.83 would be eliminated, resulting in a much lower electricity bill. Model: isaver 70A (50 KVAR) Condition Voltage Current KVA Power Factor KVAR Frequency Without isaver 230.6 93.2 64.4 0.83 35.92 49.99 With isaver 233.8 77.7 54.5 0.99 1.2 50.01