Guidance Note on Flushing



Similar documents
Control of legionella bacteria in water systems

A guide for employers

Managing the Risk of Legionnaires Disease in Vehicle Wash Systems

Legionnaires disease. A brief guide for dutyholders. Who is this leaflet for? What is legionnaires disease? Where are legionella bacteria found?

Legionella: The Invisible Killer

Legionella Managing Risk. Judith Richardson Director Qube Environmental Asbestos & Legionella Management

Controlling Legionella in Plumbing Systems. Presented by: Julius Ballanco, P.E. President, JB Engineering and Code Consulting, P.C.

Hot water supply, distribution and use

Outbreak of Legionnaires disease in a hotel in Calpe, Spain December 2011 January February 2012

Legionnaires disease: Technical guidance Part 3: The control of legionella bacteria in other risk systems

your water pressure explained

Ultra Violet Disinfection

SWINE FLU: FROM CONTAINMENT TO TREATMENT

Legionnaires disease. Part 2: The control of legionella bacteria in hot and cold water systems

ASTACEA4 Inspect complex/central air conditioning systems

WATER HYGIENE, AIR CONDITIONING & LEGIONELLA POLICY

19/02/2014. Bed Bug Control in the United Kingdom. Contamination. Key UK Requirements -Why do we Need to Control Pests? Eradicate/control species that

Thermo Siphon Solar Systems

Controlling Scalding Risks from Bathing and Showering

ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website

Fire Safety Risk Assessment Checklist for Residential Care Premises

Design Utility Lever Thermostatic Bath Shower Mixer

THE BLUE WASHING BOOK

CONTROL OF LEGIONELLA AUDIT PROFORMA

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List

Design Requirements for Eyewash and Safety Shower Units APPLICATION: Detailed Installation, Operation and Design. Eyewash Stations.

All About Your Peripherally Inserted Central Catheter (PICC)

Morco House Riverview Road Beverley HU17 0LD

BIOSECURITY PROCEDURES IN POULTRY PRODUCTION

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

Indoor Air Quality Issues for Hotels

Session 2: Hot Water Supply

Heart transplantation

European Guidelines for Control and Prevention of Travel Associated Legionnaires Disease

Inspection and Testing of Water-Based Systems

Rehabilitation at Home

Assembly and instructions

Ozone in Cooling Towers : Hygiene for us

Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Shower Handbook (Also covers 650 chrome variant)

Guidelines for Control of Legionella in Ornamental Water Features

WC flushing cistern single or dual flush to fill in 2 minutes WC trough cistern 0.15 per WC Wash basin tap size 1 2

Use less water Page 1 of 6

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

E-gas Instant Gas Water Heaters

A guide to developing risk management plans for cooling tower systems

Safe Bathing, Hot Water and Surface Temperature Policy

Chill 4 Hole Bath Shower Mixer

ECHM Recommendations for Safety in multiplace medical hyperbaric chambers

READ THIS LEAFLET VERY CAREFULLY, AND KEEP IT IN A SAFE PLACE. FLU IS SPREADING IN IRELAND, AND THIS INFORMATION IS IMPORTANT FOR YOU AND YOUR FAMILY.

RHODE ISLAND. Downloaded

GUIDE TO LCA STANDARDS FOR SERVICE DELIVERY

FIRE RISK ASSESSMENT

How to Prepare Powdered Infant Formula in Care Settings

How to Protect Your Property Against Plumbing Disasters

Modeling, GIS Software Optimizes Water Main Cleaning By Paul F. Boulos

A Do-It-Yourself Home Water Audit

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat

Pneumonia. Pneumonia is an infection that makes the tiny air sacs in your lungs inflamed (swollen and sore). They then fill with liquid.

THERAPEUTIC USE OF HEAT AND COLD

4. HOUSE RULES TEMPERATURE CONTROL

Flushing and Cleaning the A/C System

Automatic Fire Sprinkler Submittal Requirements

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

No. Name of Legislation Applicable Issues and Requirements Demonstration of Compliance 1. Health and Safety at Work Act 1974

Cadet Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Response, Reliability and Results in the delivery of leak detection services

A Guide to Breast Screening

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

ASOS Ethical Code of Conduct

Managing your bladder with a suprapubic catheter at home

SPRINKLER SYSTEM PLANS AND CALCULATIONS CHECK LIST

These are illnesses which might not only spoil your holiday but might also pose a risk to your life.

When Safety Comes First. Emergency Safety Shower and Eye Wash Catalogue

CARING FOR YOUR WATER HEATER

A Sanitarian s Role During Disaster Relief Efforts

Clean & Clever Energy Toolkits Hot Water System

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Useful contacts. Call to hear the latest information on swine flu. England:

FIELD TESTS OF FUEL EFFICIENCY MAGNETS J A CRABB JULY 1997 SWEEG REPORT 80

Chapter 10. Key Ideas Correlation, Correlation Coefficient (r),

Home comfort: water heating

Version Introduction page 3. Our Commitment Page 4. Will I be exposed? Page 6. Where will it be? Page 8. Translation page 12

Maintaining Fire Protection Systems

Tuberculosis: FAQs. What is the difference between latent TB infection and TB disease?

Home Fire Sprinkler Facts vs. Myths

Quantifying the energy and carbon effects of water saving summary report

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

OBJECTIVE: To provide safe storage and handling for vaccines and medications that require refrigeration.

Lead Understanding Lead Exposure

State Of Wisconsin Department of Military Affairs

Apricot Kitchen Sink Tap

Laddomat Charging unit

Recall and Reminder Policy and Procedure Manual Best Practice

Liquorice Kitchen Sink Tap

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

Transcription:

Legionella and Building Services Flushing Conventional Showers Lessons Learned Guidance Note on Flushing Disclaimer Please note this article is for general interest and research purposes only and does not purport to give professional advice. This article should not be considered as training material or used for any other purpose. Conventional showers of the mixer valve type are widely believed to be the single largest source of Legionnaires disease and those that are not in regular weekly use present a reasonably foreseeable risk to health and as such precautions should be taken. The UK s Health and Safety Executive / Commission describe two alternative and very different control procedures within the Approved Code of Practice and Guidance: Legionnaires disease (L8); described in the following paragraphs: 165: Conventional showers - Regular flushing and monitoring 166: Self-purging showers - Purges to drain immediately before use, via additional pipe work and without the production of aerosols. L8: Paragraph 165 Describes how the risk from Legionella multiplying in peripheral parts of the domestic water system such as deadlegs may be minimised by regular use of these outlets. When outlets are not in regular use, weekly flushing of these devices for several minutes can significantly reduce the number of Legionella discharged from the outlet. Once started, this procedure has to be sustained and logged, as lapses can result in a critical increase in Legionella at the outlet. Risk assessments may indicate the need for more frequent flushing where there is a more susceptible population present, eg in hospitals, nursing homes etc. Domestic Water Systems Controlling Legionella in typical large domestic water systems is often considered as controlling two systems which should work together; one cannot provide whole system control without the other: 1. The central system - heating devices and distribution pipe work etc 2. Peripheral systems dead legs and outlets (showers / taps) etc. All parts of the system should be designed, installed and maintained in accordance with L8 and it would be prudent to assume that Legionella is always present in domestic water systems, even when none are detected; small numbers of Legionella can enter a buildings water services on any day of the operating year. Central water systems should always minimize the number of Legionella that pass to peripheral systems; the majority of Legionella are normally killed / controlled by raised water temperatures and biocides, however, always expect small numbers of Legionella to evade the effects of these control regimes. Legionella often find passage, in low numbers, to dead legs and those serving showers are of particular concern. www.whtlimited.com Page 1 of 5

Reasons why showers are often associated with outbreaks: Most showers fall out of weekly use at sometime during their working lifetime: during holidays; refurbishments; seasonal uses; unoccupied hotel rooms etc. Showers out of use for just a matter of days have been shown to provide conditions suitable for the multiplication of Legionella and to potentially hazardous levels, conditions include: Stagnant water at room / service void temperatures; A plentiful supply of nutrients in biofilms that line the internal aspects of pipes and fittings; Combined with a very efficient means of disseminating Legionella directly to the person showering. As regular flushing continues to be associated with LD outbreaks we should consider possible reasons why. What Happens During Flushing? A competent person, with adequate training and resources behind them, should first turn the shower mixer valve onto a hot setting (lower risk cold water is normally drawn at all times by mixer valves, even on the hottest setting, however, always check this); a series of events now follows: Contaminated stagnant water from the peripheral system (shower and associated dead legs) is displaced by water from the central system; this is the cooler unwanted water found at the beginning of a shower. Flushed water carries away waterborne Legionella and shears unstable biofilm lining the internal aspects of pipe work and fittings, which harbour Legionella. Contaminated water and biofilm now passes from the shower, however, passage is often interrupted by complicated internal devices which restrict the flow; conventional spray plates are often associated with the highest levels of contamination in domestic water systems. Further consideration: Showers are often constructed to meet interior design requirements; spray plate apertures are often too fine and become easily blocked by debris and lime scale offering further obstruction. Complicated by spray plate mechanisms offering multiple spray patterns cause further obstruction to Legionella. Successful flushing requires Legionella and contaminated biofilm to pass these obstacles; when flushing it would be prudent to flush through all the different spray patterns. Flexible tap tails and shower hoses have become of increased concern, mainly due to poor material choice. However, it should be remembered that some materials which resist microbial growth when new have been shown to lose this resistance with age. Flexible shower hoses conceal another area for concern; flushing is normally carried out with the shower clipped up or placed on the shower floor. Hydraulic shocks can dislodge biofilms, however, the physical movement of pipes and hoses can also dislodge biofilm into the shower spray water flow. After flushing, the next user can move the hose and heavily contaminated www.whtlimited.com Page 2 of 5

biofilms may become dislodged and potentially infect the user. Flexible showerhead hoses can allow shower heads to enter bath on this. L8 describes how showerheads should be dismantled, descaled and cleaned, quarterly or as necessary; it would be prudent to clean at least quarterly. If the showerhead can enter bath water further consideration should be given to more frequent cleaning a grossly underestimated area for concern. The hydraulic characteristics of water systems have a big effect on flushing; flushing at 1 Bar is completely different to flushing a system at 0.3 Bar. Debris, biofilm and Legionella must be carried from the system, the slower the water velocity the less effective this process will be. Some specialist shower manufacturers recommend flushing above 0.5 Bar. Low flow rate showers should be designed with flushing considerations in mind unfortunately water conservation is not very helpful for flushing of showers. The designated flusher should flush for several minutes, the time should be detailed in the risk assessment, however, this should cover local variations, which include: Different water pressures; Different sizes of spray plate apertures and other obstructions; Mixer valves, mixing water in different quantities; Different dead leg lengths; Different constructions: fixed showers / hoses; Different materials; ages; contamination levels; Different people flushing in different ways; Different shower head cleaning regimes; Seasonal variations internal / external system factors (article to follow on this point). It is impossible to calculate an exact time to flush showers, however, several minutes seems to cover most eventualities; many choose five minutes. Always check to see how long hot water arrives at the outlet; L8 describes it should take no longer than one minute to reach 50 C. When you consider dead leg constructions, one minute is a very long time for this to take place. Monitoring Monitoring the contamination found in showers will help assess if regular flushing is effective, however, it may indicate that flushing should be carried out at more regular intervals. Independent scientific studies about daily flushing have been published, and describe this as an effective means of controlling Legionella at the shower. Those showers which are not controlled successfully by weekly flushing should be flushed more frequently. L8 does however recommend that flushing is carried out more frequently where highly susceptible occupants are present. Monitoring is useful to check the efficacy of control regimes; however, it is not an alternative to maintaining regular shower flushing records, which should be checked very regularly, if not daily, to detect underused outlets. Where multiple showers are fitted, e.g. hotels, it is difficult to detect if a shower has been used; a very common mistake is to simply assume www.whtlimited.com Page 3 of 5

room occupancy means the shower has been used. The personal health risks of those designated to flush showers should also be considered see below Hospital Shower Fatality - Independent Inquiry, Ireland After a hospital related showering fatality, a full independent inquiry was held and the findings published in 2003, this was made available for all to inspect and learn from; clearly a transparent process which helps build public confidence. The inquiry highlighted those staff that should not be considered for flushing, which included those who are, or suffer from the following: Smokers Diabetes Chronic lung or kidney disease Immunosuppressant - especially that caused by steroid therapy Staff who have had an organ transplant Alcoholics (Age guidelines should also have been considered) The inquiry also highlighted a protocol for flushing, and the following was highlighted: All outlets to be flushed daily whether in use or not; Flushing requires that water flows through the outlet for a period of at least 5 minutes; Flushing should take place after the facility has been cleaned; Showers should be flushed at the maximum hot setting; Doors to en-suite facilities should remain closed during the flushing period and should display a notice indicating that cleaning is in progress and the facility is out of use; Daily flushing to be recorded accordingly. (Flushing through different shower head spray patterns should be mentioned - when fitted) Why is Regular Flushing Often Associated with Legionella Infections? We often read about cases of LD attributed to a rare and unusual set of circumstances, however, in reality these circumstances are very common in showers. L8 describes how the logging of regular flushing is important, as lapses have been shown to cause a CRITICAL increase in Legionella at the outlet; this is not an overstatement, scientific studies have previously used logarithmic scale graph paper to plot this increase. When flushing lapses occur there is a reasonably foreseeable potential risk to health and this is likely to be one of the main reasons why flushing showers, or rather flushing lapses, is often associated with LD outbreaks. There is often much confusion surrounding showers during outbreaks, and it should be remembered that a conventional shower providing a lethal dose of Legionella one day may be perfectly safe to use the next day. It would be prudent to always maintain regular flushing records in compliance with L8. www.whtlimited.com Page 4 of 5

Alternative to Flushing Guidance Note on Flushing L8 describes that regular flushing may be difficult to achieve, and in these instances it describes an alternative solution: self-purging showers, technology described in paragraph 166 of L8. A Cautionary Note As the media reports the ever-increasing number of fatalities associated with conventional showering, which in turn improves the general publics' awareness, it is no surprise to hear of an increase in the number of legal claims against implicated organisations. A Legionella infection of increasing concern is Pontiac fever, which is a self limiting flu-like illness; it is believed that a number of opportunistic claims have been made against those offering showering services and without adequate control regimes in place there will always be an increased risk to both health and business. www.whtlimited.com Page 5 of 5