General Background. Closed Circuit Hydraulic Systems. Closed Circuit Hoisting. Safety Problems with Closed Circuit Hoisting



Similar documents
Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

COUNTERBALANCE VALVES

Example. Fluid Power. Circuits

Energy Recovery System for Excavators Meng (Rachel) Wang, Chad Larish Eaton Corporation

TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Hydrostatic closed loop Bosch Rexroth. Fuel tank 180 l 180 l

TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL

Unit 24: Applications of Pneumatics and Hydraulics

Hydraulic Hybrids from Rexroth: Hydrostatic Regenerative Braking System HRB

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL

hance the application of specific components, such as pumps, motors, accumulators, filters, and airline lubricators.

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

HOW HYDRAULIC TRUCK CRANES WORK

Unit 24: Applications of Pneumatics and Hydraulics

NEM at a glance Company, product index.

RT100 ROUGH TERRAIN CRANE DATASHEET - IMPERIAL. Features:

Unit 24: Applications of Pneumatics and Hydraulics

Hydraulic Flow Control Valves

PART 2 FORKLIFT HYDRAULIC SYSTEM

HYDRAULIC CIRCUIT DESIGN AND ANALYSIS

RT 780. RT USt Lifting Capacity Rough Terrain Cranes Datasheet Imperial. Features

Basic Symbols. Lines. Circular. Square. Diamond. Miscellaneous Symbols. -continuous line - flow line. -dashed line - pilot, drain

HRB Hydrostatic Regenerative Braking system from Rexroth for commercial vehicles:

ACTIVE PARTNER OF CUSTOMERS

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Oil and Coolant Circulating Heating System. Model - OCSM

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

Introduction to Process Control Actuators

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

Chapter 7 Hydraulic System Troubleshooting

PUMP AND MOTOR DIVISION

Cat Electronic Technician 2015C v1.0 Product Status Report 2/20/2016 4:34 PM

Electro-Mechanical Landing Gear System. Landing Gear and Brakes

Industrial Valves. Marketing Catalog. Reliable and continuous performance in the world's most demanding and rigorous applications.

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

2. Crane standing on firm, horizontal ground.

Cat Electronic Technician 2015A v1.0 Product Status Report 6/3/2015 4:41 PM

Design Considerations for a More Efficient Power Unit Circuit

307E. Mini Hydraulic Excavator. Standard Bucket Size 0.33 m 3 Engine Model Cat C2.6 DI Turbo. Weights

Flow divider (flow distributor), type TQ

SIMPLIFIED VALVE CIRCUIT GUIDE

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Cart Lifts - Models Tilts, Lift & Rotates, Lift & Tilts

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

Pressure Relief and Regulating Valves

TOYOTA ELECTRONIC TRANSMISSION CHECKS & DIAGNOSIS

PVH131/141 Variable Displacement Piston Pump - 11 Design

PX Series. from 18 to 29 m

TECHNICAL INFORMATION Bulletin

UNIT 1 INTRODUCTION TO AUTOMOBILE ENGINEERING

Why and How we Use Capacity Control

301.7D. Mini Hydraulic Excavator

Hydraulic Control Technology for Wind Turbine Generators

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

Heavy Duty Equipment Mechanic (Class Code 3743) Task List. Inspection and Diagnosis

Chapter 19 - Common Rail High Pressure Fuel Injection Systems

Diagnosing Hydraulic Problems

HMIS Top Drive System

Root & Contributing Causes. Site Answers & Comments: Preventative / Recommended / Accepted Steps of Risk Mitigation, Points of Interest:

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Safe performance. Cranes ideally suited for heavy lifts. Gottwald, Düsseldorf, Germany

Hydraulic Troubleshooting PRESENTED BY

SIMPLIFIED VALVE CIRCUIT GUIDE

Signature and ISX CM870 Fuel System

303.5E CR, 304E CR, 305E CR, 305.5E CR

BRAKE SYSTEMS 101. Energy Conversion Management. Presented by Paul S. Gritt

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

Mobile Case Studies in Success

EQUIPMENT SAFETY EARTHMOVING MATERIAL HANDLING NAVFAC MIDLANT

Presented by Rory S. McLaren. SAFE by DESIGN

Quiz On Information Learned From Chapter 1

Pneumatic control for robotics and industrial automation Author: Naresh Raghavan

Grade 8 Science Chapter 9 Notes

Analog Amplifier Rexroth RA: Easy, user-friendly control of pumps and valves

Pumps SELECTION OF A PUMP

Automatic Back-Flushing Filter AutoFilt RF9.

PUMPS TYPE OF PUMP PRESSURE/FLOW RATING CHARACTERISTICS. Centrifugal Low Pressure/High Flow Flow changes when

ASK 40 TK 4+2 FULL FOLDING HYDRAULIC CRANE

S KID S TEER L OADER SK818-5 SK818-5 SK NET POWER SAE J ,7 kw. OPERATING WEIGHT kg. OPERATING CAPACITY 870 kg

Hydraulic Crawler Crane

FTheBetterMachine. Technical Description R 992. Hydraulic Excavator

Control block EDD Modular Directional Valve

MANTSINEN. HybriLift. More load, less energy.

Technical Service Information

SP / SP / SP Trailer Mounted Concrete Pumps

Aviva Insurance Limited

Basic Hydraulics and Pneumatics

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

ACADEMIC TEXTBOOK FLUID POWER CONTROL SYSTEMS. The lecture: 15 hours. Kielce University of Technology Faculty of Mechatronics and Machine Design

Hydraulic Landing Gear System

Series TMM Axial Piston Motor. Technical Information

E08 E10. Compact Excavators

Stop Alert Flasher with G-Force sensor

Rexroth Hydraulic Pump A10VO Series User Manual

Information regarding the Lockheed F-104 Starfighter F-104 LN-3. An article published in the Zipper Magazine #48. December Theo N.M.M.

McCAULEY CONSTANT SPEED PROPELLER GOVERNING SYSTEM

Transcription:

Page 1 of 5 General Background High pressure, variable displacement piston hydraulic systems provide the best performance, efficiency and component life for use in high duty cycle offshore cranes. Piston hydraulic circuits are available in two configurations, closed circuit and open circuit. The following information details the safety and ramifications of closed and open circuit hydraulic systems as applied to hoisting and slewing operations of offshore cranes. Closed Circuit Hydraulic Systems The pump in a closed hydraulic circuit discharges directly to the hydraulic motor, and flow exits from the opposite port of the motor directly back to the pump. The hydraulic fluid moves in a closed loop from which it does not escape. With a closed circuit system, the pump has a rotating swashplate. The position of this swashplate selects the direction and volume (volume determines hoisting speed) of pump flow or, if the swashplate is vertical, then no flow occurs (neutral). The best application for closed circuit hydraulic systems is on equipment with horizontal, reversing loads. For example, by far the most common application for closed circuit hydraulic systems is vehicle ground drives, such as crawler mounted earth moving equipment, off-road construction and agricultural equipment. Closed Circuit Hoisting Hoisting on a crane is not a horizontal, reversing load. When hoisting vertically (lifting) in the up direction, the pump builds pressure until great enough to lift the load or the boom. When lowering, the same side of circuit is under pressure. Dynamic braking, controlling the vertical descent of a load or the boom without them running away, with a closed circuit hydraulic system is accomplished by back driving the pump. The pump and diesel engine control the vertical descent of the load and combined are the dynamic brake. Safety Problems with Closed Circuit Hoisting The diesel engine in a closed circuit hoisting system must develop sufficient power to drive all three primary crane motions at full load and full speed at the same time. Otherwise loss of dynamic braking

Page 2 of 5 capability can occur because of engine overload while lowering the boom and the hook at the same time. If sufficient power is not available at the engine for dynamic braking during simultaneous operations, the engine will back drive just as it would on a mechanical crane, and loss of control of the load will occur. The diesel engine must run at high throttle at all times during heavy lifting operations with a closed circuit hoist equipped cranes to keep the power level up for dynamic braking. The high kinetic energy from vertically suspending heavy loads and the weight of the boom often make it impossible to dynamically brake simultaneous operations with a reasonably-sized engine, even at full engine speeds. As a result of running the diesel engine and pumps at high speeds, controllability while safely moving heavy loads by small increments is reduced. In addition, prime mover failure, for any reason, can result in loss of control of the load. Closed Circuit Hoisting Complexity Extremely complex and difficult to maintain ancillary electronic and hydraulic control circuitry is added to closed circuit hydraulic vertical hoisting systems in an attempt to reduce the risk of the basic safety flaws inherent with closed circuit hoisting and dynamic braking. (PHOTOS SHOW COMPETITOR S HYDRAULIC SYSTEM) Needle Valve Panels Open Circuit Piston Hydraulic Hoisting Systems The piston pump in an open hydraulic hoisting circuit draws fluid from a storage tank or reservoir and then discharges it through a directional control valve which is used to select up, down or neutral. Flow from this valve goes to the motor and then back to the tank (up or down) or goes directly back to the tank when in neutral. The position of the rotating pump swashplate selects the volume of pump flow (volume determines hoisting speed). Open circuit dynamic braking is accomplished by means of a dynamic brake or counterbalance valve which is fitted directly to the hydraulic motor. The energy of vertically lowering the load and boom at a controlled speed is converted into heat in the hydraulic fluid by forcing it to effectively flow through a small orifice at high pressure. The full volume of fluid exchanges with the tank (it is not trapped in

Page 3 of 5 a closed circuit), so it is a simple matter to maintain cooling via a full flow heat exchanger and tank baffling. Open Circuit Hoisting When hoisting vertically (lifting) in the up direction, the pump builds pressure until great enough to lift the load. The hoisting speeds are controlled by the pump and diesel engine speed. The dynamic brake valve is bypassed in the up direction. Open Circuit Dynamic Braking Dynamic braking (controlling the vertical descent of a load or the boom without them running away) with an open circuit hydraulic system is accomplished by applying positive pressure in the downward direction to slightly pilot open the dynamic brake valve. In other words, the dynamic brake valve controls the descent of the load rather than the pump and diesel engine. Advantages of Open Circuit Hoisting Systems The open circuit hoisting configuration overcomes the inherent safety problems associated with using closed circuit systems to handle vertical loads as described below. The open circuit diesel engine plays no role in dynamic braking of vertical loads. This means that the prime mover need not be sized based on the potential full power requirements of the three primary crane motions. It is NOT possible for the engine to back drive resulting in a loss of control of the load. For this reason, a failure of the prime mover cannot and will not result in loss of control of the load. It is not necessary to run the diesel engine at high speed. Full rated loads, on both the boom and the hook, can be lowered under full control with the engine operating at idle speed. Since the diesel engine and pumps can safely operate at low or high speeds, controllability while

Page 4 of 5 safely moving heavy loads by small increments is greatly enhanced by modulating the pump AND engine speeds. Open Circuit Hoisting Simplicity Open circuit hoisting does NOT require complex and difficult to maintain ancillary electronic and hydraulic control circuitry. The basic arrangement is inherently safer in its basic design. This allows for a safe, easy to maintain high performance arrangement for handing of vertical loads. (PHOTOS OF SEATRAX ARRANGEMENT) Closed Circuit Slewing Systems When slewing a crane, the loads are horizontal and reversing, so a closed circuit hydraulic arrangement provides the best service. Because of the lower horsepower demand of the slew system, the engine does not always have to run at high speed to ensure dynamic braking. Since the diesel engine and pumps can safely operate at low or high speeds, controllability while safely slewing heavy loads by small increments is greatly enhanced by modulating the pump and engine speeds. Closed Circuit Slewing A closed circuit slew system is arranged with a conventional closed circuit hydraulic system. Loads are horizontal and reversing rather than vertical and suspended. When the slew joystick is released, the crane automatically decelerates in a smooth manner without consuming excessive power. This operating characteristic is especially useful on cranes mounted on floating and listing installations.

Page 5 of 5 Seatrax High Pressure, Piston Hydraulic Systems Seatrax combines the most favorable safety-in-design, fail-safe hydraulic arrangements available for offshore cranes. For hoisting of suspended, vertical loads and the weight of the boom, open circuit hydraulic systems are used. For handling the reversing, horizontal loads associated with the slew system, closed circuit hydraulic systems are used. Each hydraulic system type has distinct operating advantages depending on the crane operation type, and Seatrax utilizes these advantages to the fullest by combining the system types. The fully closed hydraulic circuit was used by Rexroth, the hydraulic equipment supplier for many offshore cranes, before the combined approach was available. Rexroth agreed to develop the combined closed/open piston hydraulic system because customers such as BP, Shell, Kerr McGee, Chevron Texaco, Conoco-Phillips, Petrobras and many drilling contractors had expressed a strong interest in an arrangement that had safer operating characteristics than the fully closed circuit, without the associated complexity and high operating costs associated with the fully closed hoisting hydraulic circuits. The Seatrax combined closed/open hydraulic system is the successful result of years of joint development between Rexroth and Seatrax, which includes development, detailed design, testing and refinement. Dozens of these systems are operational throughout the world, providing a safer, more dependable solution for hydraulic marine cranes.