Installation, Operating and Servicing Instructions. Electric Auto-Fill Push Button Water Boilers EB3F/PB and EB3F/PBM



Similar documents
FilterFlow Automatic Water Boilers. Pure Quality

Please read and keep these instructions. Run water through your machine before first use

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

ClearView 100. Instruction Manual

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

GeyserWise TSE. thermostat instruction manual. SANS 181 compliant

CARING FOR YOUR WATER HEATER

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Ambiente Quick Reference Manual

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Hot Water Urns. all models. Helpline. v3.0

Tassimo The Art of the Perfect Cup

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Get Me Cool Now Portable Air Conditioner User s Manual

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Portable Air Conditioner

Operators manual Basic water heater

B150 Series Commercial Brewer. Direct Plumb Kit

Thermostatic bar showers. Troubleshooting and maintenance

SF15K SF05KSS, SF10KSS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual


SHOT BLAST CABINET MODEL NO: CSB20B

OR S HANDBOOK Kenco S i n g l e s B r e w e r OPERA

Troubleshooting Guide for Dispenser Model #900172

Assembly and instructions

12 cup programmable coffee maker

100 Series Maxi Internal Filters. Instruction Manual

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

WHEN TO CHANGE YOUR BRITA MAXTRA CARTRIDGE

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser


- 2 - IMPORTANT SAFETY REMINDERS

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

INFRARED QUARTZ WALL HEATER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

2-SLICE COOL TOUCH TOASTER

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

SunMaxx Solar Filling Station Operating Instructions

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Use and Care Manual. Model CPA12KH AIR CONDITIONER

USER S MANUAL HSC-24A

User's Instructions. Alpha HE CB25/33 and HE SY25

Aquatap (Boil and Chill / Boil and Ambient) Installation and user manual

Meaco 30L and Meaco 40L dehumidifier instruction manual

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

3 IN 1 BATHROOM HEATER

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Electric Instantaneous. Water Heaters. Service manual

Make sure oven is OFF. Never remove parts or touch the fan unless the oven is OFF.

Getting the best from your urn

Record Cleaning Machine

Chill 4 Hole Bath Shower Mixer

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

PORTABLE AIR CONDITIONER

Electronically Controlled Instantaneous Water Heaters Models: DEX & DBX

OPERATION GUIDE. IMPORTANT NOTE: For more information see our instructional video online at model no.

DIGITAL PARAFFIN DISPENSER MODEL DP 2010 PROCEEDING MANUAL

Moda. Instructions for use. Breville Customer Service Centre Australian Customers. Cordfree Kettle. New Zealand Customers

This section gives you some helpful information and tips on running your home and the equipment in it.

Installation Instructions Avalanche XUV Cap IMPORTANT! IMPORTANT!

Design Utility Lever Thermostatic Bath Shower Mixer

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

Safety, Operation and Maintenance Manual with Parts List

SELECTION, APPLICATION AND MAINTENANCE

Aquamax Australia Pty Ltd ABN

Utility Distribution Systems

Users Instructions BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Isotemp Basic, Slim/B & Slim Square

Your safety and the safety of others are very important.

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Coolflo Safe Touch Shower Mixing Valve ST20015CP

SunMor SM-V30 Solar Water Heater Installation Manual

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

3 WATT LED SPOTLIGHT Model No. SLM

Cadet Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference

SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safely precautions,

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

Transcription:

Installation, Operating and Servicing Instructions Electric Auto-Fill Push Button Water Boilers EB3F/PB and EB3F/PBM Please make a note of your product details for future use: Date Purchased: Model Number: Serial Number: Dealer: IS425 ECN 3607 Page 1 of 12

CONTENTS Important Information 2 Warnings and Precautions 3 Technical Data 3 Checklist of Enclosures 3 Installation and Commissioning 3-4 Operating Instructions 5-7 Cleaning 7-8 Servicing, Maintenance and Component Replacement 8 Fault Finding 9 Spare Parts List 10 Accessories 10 Service Information and Guarantee 11 IMPORTANT INFORMATION Read these instructions carefully before using this product, paying particular attention to all sections that carry warning symbols, caution symbols and notices. Ensure that these are understood at all times. WARNING! This symbol is used whenever there is a risk of personal injury. CAUTION! This symbol is used whenever there is a risk of damaging your Lincat product. NOTE: This symbol is used to provide additional information, hints and tips. KEEP THIS MANUAL FOR FUTURE REFERENCE IS425 ECN 3607 Page 2 of 12

WARNINGS AND PRECAUTIONS This appliance must be installed, commissioned and serviced by a qualified person in accordance with national and local regulations in force in the country of installation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person. Ensure that the plug/socket is accessible at all times. Strip plastic coating and clean the appliance before use. During operation parts may become hot - avoid accidental contact. Disconnect this appliance before servicing, maintenance or cleaning. TECHNICAL DATA Model Height (mm) Width (mm) Depth (mm) Weight (kg) EB3F/PB 655 290 465 13.0 CHECK LIST OF ENCLOSURES Warranty card Instructions manual Drip tray and insert Inlet hose with ¾ BSP connection FilterFlow badge Sample of descaling agent INSTALLATION AND COMMISSIONING This appliance must be earthed. An equipotential bonding terminal is provided to allow cross bonding with other equipment. IS425 ECN 3607 Page 3 of 12

If replacing the plug connect the terminals as follows: Green and Yellow wire Earth E Blue wire Neutral N Brown wire Live L Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57) Install this appliance on a level surface ensuring all vents are unobstructed. The serial plate is located on the side of the appliance Fig 1 (H). Instructions for wall mounting are supplied with the wall mounting kits (see Accessories). Power Ratings Ambient Water inlet pressure Water inlet Model kw temperature Deg C (bar) pressure (kpa) EB3F/PB 3.0 5 to 30 1 to 8 100 to 800 The EB3F/PB is supplied with a 13 amp plug. Water supply and waste connection Connect the supplied white water inlet hose to the inlet connection point on the base of the boiler and the other end to the supply via an accessible isolating tap with a ¾ BSP thread. If required, the drip tray can be connected to a waste water outlet using a ½ bulkhead connector (not supplied). Knock out the blank in the tray base. If cables are required to exit at either side of the boiler the thinner section between the moulded base sides may be cut away with a hacksaw. IS425 ECN 3607 Page 4 of 12

OPERATING INSTRUCTIONS Fig 1 IS425 ECN 3607 Page 5 of 12

First Use Only qualified or trained personnel should use this appliance. Switch on the water and electricity supplies. Leave the boiler to fill for 30 minutes. Drain off approximately 5 litres of water to remove any loose carbon particles from the filter. Regular Operation The boiler starts automatically when the water supply is turned on. During the heating cycle, only small quantities of water are added to ensure hot water is always available at the dispenser. The boiler is designed to be permanently switched on: it is only necessary to turn it off for de-scaling or maintenance. Water is drawn off through the dispenser (G). Adjustment Water temperature, screen backlight and contrast Consult Fig 1. Turn power off and on again. The FilterFlow screen (B) is displayed on the control panel (A). Press and hold the power button (D) until the software version is displayed. Press the function button Fn (C) and the temperature will be displayed. Press the power button to cycle through the values 70 to 96 Deg C. Press the Fn button to select the required value. The backlight adjustment screen is displayed next. Press the power button to cycle through the values 1-25. Press the Fn button to select the required value. The contrast adjustment screen is displayed next. Press the power button to cycle through the values 35 to 60. Press the Fn button to select the required value. Press the power button to exit. EB3F/PBM PROGRAMMING GUIDE The PBM version of the EB3F has the option to preset up to 3 measured dispense sizes. This quick guide shows the procedure for programming the water boiler. The measured dispense can only be set when the unit is full and up to temperature. So connect the unit to the water supply and electric, allow 30 minutes for the unit to fill and heat. IS425 ECN 3607 Page 6 of 12

To enter the programming mode, turn the electric off to the unit. Press and hold the power button and turn the electric on. After a few seconds the programming mode is entered. Push the Fn button until the Use dispense screen is visible. Pressing set turns off the timed dispense and the unit changes to Push and hold for dispensing Press next. Press set to select 1, 2 or 3 measured dispenses. Press next. Press yes to select to set the dispense volumes. Or next to exit. Select the size to set. Press OK. Press and hold the Hot water button to fill the chosen cup / mug. Release the button when the cup is full. After filling there is a chance to test the volume and then either repeat the setting procedure or accepting the set volume. Press OK to accept Press exit to return to the standard User screen or next to continue and programme more sizes. The unit also has some built-in safety features when in measured dispense mode. These are Pressing the Hot water button at any time during the filling will stop the fill cycle. Other size receptacles can be filled be pressing and holding the Hot Water button until full, similarly under-filled receptacles can be topped up in this way. IS425 ECN 3607 Page 7 of 12

Standby If the boiler is left unused for any length of time, turn the element off by pressing the power button. Filter replacement The filter display shows the estimated life remaining in the filter cartridge (Fig 2). A reminder message is displayed when the filter needs changing. The boiler can be used without a filter, but scale will quickly build up and water taste may be affected. FILTER READY CHANGE FILTER STANDBY CLEAR To replace the filter Fig 2 Remove the drip tray from the appliance. Pull the bottom of the lower panel (Fig 1 (F)) outwards and release the two spring pins. Slide the panel downwards to remove. Twist the base of the filter 90 degrees to the left and lower the cartridge out of the appliance. It will contain a small amount of water, Remove the black cap and place it on the new filter. Re-insert the filter into the recess and lock into place by twisting to the right. Refit the lower panel. For EB3F/PB, hold the Fn button for 10 seconds to reset the filter life. For EB3F/PBM hold the Fn and On/Off buttons down simultaneously for 10 seconds. Drain off approximately 5 litres of water to remove any loose carbon particles from the filter. CLEANING Do not use a water jet or steam cleaner, and do not immerse this appliance. Clean all panels with warm water and mild detergent, do not use abrasive IS425 ECN 3607 Page 8 of 12

materials. Dry with a soft cloth. Slide out and empty the drip tray regularly, and wipe the dispensing nozzle daily to remove limescale deposits. De-scaling The boiler should be de-scaled regularly to maintain efficient operation and water quality. The frequency depends on the hardness of the water and timely replacement of the filter. The de-scaling procedure must be performed by trained personnel as it requires the removal of panels from the boiler giving access to live electrical components. De-scaling the boiler at the end of the working day gives the de-scaling agent several hours to work. Lincat recommend our own de-scaling agent MS19, available from our Spares department. Wear protective clothing. Isolate the boiler from the electrical supply. Turn off the power and allow the water to cool to 60 Deg C. Using a 3mm Allen key, remove the screw in the top of the boiler. Remove the insulation from the top of the tank. Unscrew and remove the tank lid. Add the de-scaling agent slowly to avoid eruption of the water, following the manufacturer s instructions. Replace tank lid and outer lid and attach an Out of Use notice to prevent use during de-scaling. Turn on the electricity and run the boiler normally for 30 minutes. Isolate the boiler and allow the water to cool. Remove both outer and tank lids again. Inspect the tank and level sensor housings for scale deposits. If necessary, repeat the de-scaling process. Drain and flush de-scaling agent as follows: Remove the drip tray, lower panel, silicone dispense hose and the inner cover. Connect a hose from the overflow pipe to a bucket and open the service valve to drain the water from the tank. Flush the tank with clean water, shut the valve and replace the covers. Replace the drip tray and tank lid, ensuring the gasket is sealing the top of the tank correctly. Re-fit the outer lid and turn on the boiler. IS425 ECN 3607 Page 9 of 12

SERVICING, MAINTENANCE AND COMPONENT REPLACEMENT Other than replacing the filter, all servicing, maintenance and component replacement on these appliances should be carried out by one of our recommended service engineers. FAULT FINDING The control panel displays information that can help with fault diagnosis. Before calling for service, draw off a litre of water, clear the fault code by pressing the Fn button and turn the boiler off and on again at the supply. If the fault persists, call service for advice. Message displayed Possible causes Corrective action FILTER CAUTION SEE MANUAL DESCALE Scale on level sensors Boiler overfilling Descale Check water inlet valve STANDBY CLEAR FILTER STANDBY FILTER STANDBY FILTER CAUTION SEE MANUAL NO WATER CLEAR NOT HEATING CAUTION SEE MANUAL CLEAR THERMISTOR CAUTION SEE MANUAL Water turned off Inlet hose kinked or blocked Water pressure too high or too low Drain valve open Boil dry/overheat protector tripped Temperature sensor fault Element failed PCB fault Faulty or loose connection Temperature sensor fault Check water supply and drain valve Call service if fault persists Check connections Call service if fault persists Call service STANDBY IS425 ECN 3607 Page 10 of 12

SPARE PARTS LIST Part Number CO206 CO251 DV02 EBM05 EL235 FC02 FH02 GA48 LE47 LE48 LE49 PI12 PL202 PR77 SO24 SV03 SW86 TH87 TH88 TH98 Description ¼ to 3/8 elbow Dispensing nozzle Service valve Outer lid Element Filter cartridge Filter head Lid gasket Level sensor insulator Upper level sensor Lower level sensor Inlet hose Mains cable Circuit board Solenoid valve Dispenser solenoid valve Dispenser switch 95 o cutout thermostat 120 o cutout thermostat Thermistor ACCESSORIES Part Number BR49 FC02 Description Wall mounting kit Replacement filter cartridge IS425 ECN 3607 Page 11 of 12

SERVICE INFORMATION For help with the installation, maintenance and use of your Lincat equipment, please contact our service department: UK: 01522 875520 For non-uk customers, please contact your local Lincat dealer All service work, other than routine cleaning should be carried out by one of our authorised service agents. We cannot accept responsibility for work carried out by other persons. To ensure your service enquiry is handled as efficiently as possible, please tell us: Brief details of the problem Product code Type number Serial number All available on serial plate Lincat reserve the right to carry out any work under warranty, given reasonable access to the appliance, during normal working hours, Monday to Friday, 08:30 to 17:00. GUARANTEE This unit carries a comprehensive UK mainland 2 year warranty. The guarantee is in addition to, and does not diminish your statutory or legal rights. The guarantee does not cover: Accidental damage, misuse or use not in accordance with the manufacturer s instructions Consumable items (such as filters, glass, bulbs, slot toaster elements and door seals.) Damage due to incorrect installation, modification, unauthorised service work or damage due to scale, food debris build-up, etc. The manufacturer disclaims any liability for incidental, or consequential damages. Attendance is based on reasonable access to the appliance to allow the authorised technician to carry out the warranty work. Service calls to equipment under warranty will be carried out in accordance with the conditions of sale. Unless otherwise specified, a maximum of 15 minutes of administrative time, not spent directly carrying out servicing work, is provided for within the warranty. Any requirement for staff attending the call to spend greater time than 15 minutes due to administrative requirements, such as on health and safety risk assessments, will be chargeable at the prevailing rate. IS425 ECN 3607 Page 12 of 12