Flow divider (flow distributor), type TQ



Similar documents
3/2- and 2/2-way cartridge valve type BVE

Line rupture protection valves type LB

Directional seated valves type VP 1

Radial piston pumps type R and RG

2-way flow control valve with sliding throttle type SB and SQ

Electro-hydraulic pressure switches type DG

1. General. D 7490/1 2/2-way cartridge valve EM 2.2. Operation pressure p max Flow Q max. = 450 bar = 160 lpm. Cartridge valve (see section 2)

Directional seated valves Directly actuated, leakagefree for hydraulic systems For the assembly on connection sub-plates

Over-center valves type LHK with hydraulic release

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Pressure reducing valve, direct operated, Type ZDR 6 D

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

Hydraulic Flow Control Valves

Chapter 5: Flow Valves

COUNTERBALANCE VALVES

2/2-, 3/2-, and 4/3-way seated valves type NBVP 16 with industrial standard connection pattern Cetop 3 conforming DIN A6

Variable Displacement Pump AA10VSO

Pressure Relief Valves SPV, SPVF

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

2/2 and 3/2 Way Size 6 Seat Valves

Pressure Relief and Regulating Valves

2-way flow control valve Type 2FRM 6

Unit 24: Applications of Pneumatics and Hydraulics

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY /US

Unit 24: Applications of Pneumatics and Hydraulics

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Series PVP Variable Volume Piston Pumps

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

Example. Fluid Power. Circuits

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

KDG3V-5/7/8, 10 Series

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Open center control block in monoblock design MO-40

The Secret of Hydraulic Schematics. BTPHydraulics

PUMP AND MOTOR DIVISION

Assisted lift operated 2/2-way solenoid valves Type EV250B

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

MANTA Piston Distributor for Oil and Fluid Grease

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

PART 2 FORKLIFT HYDRAULIC SYSTEM

Hydraulic control unit series

Axial Piston Variable Motor A6VM

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Valve systems Base plates, according to standard ISO Brochure

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

Series TMM Axial Piston Motor. Technical Information

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

Hydraulic Troubleshooting PRESENTED BY

Chapter 6: Check Valves

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

Check Valves Valve locator

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

SOLENOID VALVES AND PNEUMATIC VALVES

Brueninghaus Hydromatik. Variable Displacement Pump A11VO RE / for open circuits

HYDRAULIC CIRCUIT DESIGN AND ANALYSIS

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Rickmeier Solutions. Gear pumps for superior Lubrication

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

Highly flexible couplings

Load-sensing control block in mono and sandwich plate design

Unit 24: Applications of Pneumatics and Hydraulics

Why and How we Use Capacity Control

MASTER CYLINDER. Section 2. Master Cylinder. Tandem Master Cylinder. Master Cylinder

Unit 24: Applications of Pneumatics and Hydraulics

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

servo-controlled 3-WaY vacuum solenoid valves WiTH

Thermostatic valve Type AVTA

Hydraulic multidisc Brake H420

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

Specifications for Volkswagen Industrial Engine

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Hydraulic Control Solutions

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Operating Instructions Parts List Manual Scissor Lift Pallet Truck

ROTARY GEAR FLOW DIVIDERS

Foam Systems Inductors & Proportioners

Transcription:

Flow divider (flow distributor), type TQ Pressure p max = 0 bar Flow Q CN max = 00 lpm Share ratio = :. General Task Flow dividers type TQ are self-regulating valves, which largely irrespective of the pressure differentials at the operating connections A and B, divide a flow Q C entering at C into two equal output flows, Q A and Q B. Alternatively, in the opposite direction they can retain both partial flows Q A and Q B at equal rates, and combine them into one overall flow Q C. Mounting and function Two hardened and ground control pistons, flexibly linked to one another, are arranged in a steel housing in such a way that they can be easily displaced and centered in the center position (neutral position) by springs. Orifice boreholes connected one behind another in the two control pistons form throttle points with constant and variable cross-sections between the single flow connection and the two part flow connections. When an appreciable flow rate is present, pressure drops occur at these throttle points, which bring the pistons into the control position as well as balancing out any pressure difference, which may have arisen between the two part flows as a result of load differences at the connected consumer units. Accordingly, the total pressure drops between the two part flow connections and the single common connection are always of the same value; depending on the physical connection between flow resistance and flow rate, this also results in two equally high part flow rates. Application The valves are used in situations where two hydraulic consumers, fed by one pump but without any forced mechanical connection, are controlled by a common directional valve and are intended to move in and out simultaneously, without influencing one another despite differing load levels. Where hydraulic consumers of equal size are involved, this produces a certain synchronized motion, although this is dependent on the division precision of the flow distributor and the internal leakage losses of the consumers (e.g. as with hydraulic motors) and the volumetric elasticity of the system (oil compressibility, hose expansion etc.). Division precision is not a constant value, but dependent on a variety of operational parameters (see sect..), and may change in the course of a work cycle, depending for example on the load proportions. Flow dividers can therefore only fulfil the task of flow equalizer valves if a division error of a few percent is permissible and without any disturbing influence. Therefore truly exact synchronized flow control cannot be achieved. Other devices are required for this (such as mechanical flow dividers working on the gear wheel or piston principle), or proportional or servovalves for high demands, which are guided by continuous scanning of the stroke and angle of rotation. The influence of the viscosity of the pressure medium on division precision is negligible, but it becomes noticeable by way of the consumer leakage losses mentioned above. Synchronization differentials in hydraulic cylinders are balanced out in each case at the final stroke position.. HAWE HYDRAULIK SE STREITFELDSTR. 87 MÜNCHEN D 78 Flow devisers type TQ 98 by HAWE Hydraulik August 008-00

D 78 page. Types available, main data Order example: TQ -A Table : Basic type, size Table : Flow Connection mode Coding Port size ISO 8/ (BSPP) C A, B Available for basic type Coding Rated total flow Q CN ) approx. lpm Final pos. balance ) approx. lpm Pipe connection -A -A -A TQ -A -A -A G /8 G / G /8 G /8 G / G /8 G / G / G / G / G G / TQ -A to TQ -A and TQ P-A 0.78.....8 7. 0 0.... 0...7 Manifold mounting P-A TQ P-A P-A see dimensional drawings in sect.. TQ -A TQ P-A TQ -A TQ P-A )..8 70 0 0 00.. 9 7 ) Not for TQ.; Q cn, 70 lpm. Only for applications, where a greater dividing error is no problem (approx. ± 8...0%) ) Guideline for the permissible flow in at port C. In this case, a flow resistance prevails in the flow directions C A and C B (and vice versa, when two flows are joint) of about 0 bar, see p-q curves ) If (in the case of hydraulic cylinders) the advancing end comes to a standstill at the limit stop, the other end will follow according to the specified balance flow (approx. value); see note under section.. Additional data Nomenclature Spool valve Installation position Any Operating pressure p max = 0 bar Flow Q CN =.8... 00 lpm, see table Surface protection Valve housing zinc galvanized Pressure fluid Hydraulic oil conforming DIN part to : ISO VG 0 to 8 conform. DIN 9; Viscosity range: Viscosity during start min. approx. ; max. approx. 00 mm /s; opt. service: approx. 0... 00 mm /s Also suitable are biologically degradable pressure fluids type HEPG (Polyalkylenglykol) and type HEES (Synth. Ester) at service temperatures up to approx. +70 C. Temperature Ambient: approx. -0... + C; Öl: -... + C; take note of viscosity ranges! Start temperature down to -0 C are allowable (Pay attention to the viscosity range during start!), as long as the operation temperature during subsequent running is at least 0K higher. Biological degradable pressure fluids: Pay attention to manufacturers information. With regard to the compatibility with sealing materials do not exceed +70 C. Mass (weight) Type TQ -A TQ -A TQ -A TQ -A TQ P-A TQ P-A TQ P-A TQ -A TQ -A approx. kg 0. 0.. 0.7.. Dividing precision depends on total flow Q C. This should be between 0...00% of Q CN. Below 0% of Q CN, devision precision starts to drop. In this case a valve with the next smaller flow coding should be selected. The dividing precision is also dependent on the pressure differential between the consumer ports A and B. If the pressures are the same or only slightly diff. ($ 0 bar), the dividing error is about *...%.Where higher pressure differentials are involved, the dividing error increases and amounts to approx. *...% at a differential of about 00 bar for the flow characteristics A 0.78... may rise to *...% with larger characteristic values, and is approx. *...7% at A.8. Q A,B (* %) Q C / Q CN Dividing error QC Q A,B = f in % von QA,B = Q of CN at equal load pressures or low pressure differentials between the connections A and B Q C

D 78 page p-q-characteristic curves Flow resistance p (bar) Part flow Q A, B (lpm) Part flow Q A, B (lpm) Part flow Q A, B (lpm) Oil viscosity during measurement mm s. Dimensions. Pipe connection design Type TQ -A to TQ -A Type H B L a b c g l TQ -A TQ -A TQ -A 0 0 M8, thru-hole 9. TQ -A 0 8 9. TQ -A TQ -A 0 0 0 0 0 M8, 0 deep front and back, core bore is a thru-hole Do not distort the housing by forcing it against the securing plane. Insert shims as spacers to even out irregularities. Manifold mounting design Type TQ P-A to TQ P-A O-ring NBR 90 Shore Hole pattern of the manifold (top view) g Type H B L a b c d d l TQ P-A 0 0 7. 8 0 8 0. 9. TQ P-A 0 7 TQ P-A 0 0 0 Type g O-ring TQ P-A M, 0 deep.x.78 TQ P-A M8, 0 deep 8.7x. TQ P-A M0, 0 deep.x. All dimensions are in mm, subject to change without notice!

D 78 page. Special device designs. Unequal dividing ratios The smaller part flow is always at connection Max. part flow at Q A max = 0. Q CN! For Q CN of the respective metering orifice coding (flow spec.) refers to table in sect.. Valves with unequal flow ratio: The perm. inlet flow Q C perm is always lower than the Q CN. It can be determined with share parameter Available versions: z =,, Q C perm = Q A max + Q B max applies in general or QC perm = 0. QCN + z - A./ - A / Order example - A./ - A./ - A./. - A./ TQ - A / TQ.. - A./ - A./ TQ.. - A./ - A /. ) - A./ - A / ) Basic type and port size as, see sect.. - A /. - A / ) Flow rate characteristic according to sect.. for port A (Q A ) - A / - A / ) - A / Division figure for the relationship of the consumer flows QB : QA = z - A / z =... QB = Q - A / A TQ.. - A / - A /... QB = QA - A /. - A./... QB = QA TQ.. - A.8/ - A.8/ ) Not for TQ.; Q cn, 70 lpm. Only for applications, where a greater dividing error is no problem (approx. ± 8...0%). Valves only for division C A, B Share ratio : Valves featuring only a mono metering spool are only suited for flow direction C A, B. Return flow in reverse direction is not permissible with type TQ -B... to TQ -B.... TQ R-B... features an internal by-pass check valve. This enables free, but not metered return flow. Order example: TQ R-B. Table : Basic type, size Connection Coding mode Port size ISO 8/ (BSPP) C A, B Mass (weight) approx. (kg) Flow (see table, coding 0.78 to ) Symbols Remarks Pipe connection TQ -B -B -B -B G /8 G / G /8 G /8 G / G /8 G / G / 0. 0. No return flow For parameters and unit dimensions, see sect. and. TQ R-B G / G /8 0.7 Examples: Grab buckets or forks wich are intended to open quickly by grafitational force and are intended to strike against integrated stops in order to knock free any material which may still be clinging to them. Additional data for type TQ R-B p-q-characteristic curves for return flow M 8, Thru-hole Flow ressistence p (bar) Part flow Q A (B) C (lpm) All dimensions are in mm, subject to change without notice!

D 78 page. Typical circuit diagrams. Double-acting consumers or from the pump from the pump Double-acting hydraulic cylinder, e.g. acc. to D 0 Flow divider type TQ... acc. to sec.. Directional spool valve In the arrangement shown in the figure on the left, when the cylinder travels out (dividing motion), a flow resistance occurs at the flow divider for Q A = Q B = 0. Q C (= 0. Q pump ), according to the p-q characteristic (sect. ). When the cylinder travels in (joining the flows), the part flows Q A and Q B are larger due to the area ratios of the cylinder, and the pertinent flow resistance for the pump is likewise greater in the surface ratio. Particularly in borderline cases with Q pump in the range Q c max, it follows that connecting the flow divider to the piston side of the cylinder can be more satisfactory; take note of. Pressure Iimiting valves (setting value as for pump safety valve) are then to be arranged if it is intended for the final position balance of the returning cylinder to take place without any speed limitation (see ) in sect. ). The pressure limiting valve which then responds, belonging to the first to reach the final stop, simulates a continued demand for pressure fluid for the flow divider, despite the piston being at a standstill. Pressure Iimiting valves in an arrangement with the pressure divider on the piston side are always advisable, in order to avoid pressure transfers at final position compensation resulting from the cylinder surface differential. Pressure setting as for pump safety valve... Single-action, weight-loaded consumer element (stroke devices) When loads are being lowered (part flows being joined), only a small backflow resistance prevails at connection C due to the directional valve being opened to the tank. The control diaphragm on the higher-loaded consumer side (at A in the diagram) does indeed balance the pressure differential with the lower-loaded consumer, but the part flows Q A = Q B would be set which, according to the p-q characteristic in section, would be derived for p= load pressure of the lower-loaded cylinder. In order to avoid excessively high lowering speeds, the return counterflow must be limited by an appropriate flow valve to values equal to or less than $ Q CN. In the example shown, this is achieved by the throttle provided in the stroke lowering valve, or by a drop-rate braking valve pamphlet 90, or by another device of equal value. from the pump Single-acting hyd. cylinder, weight-loaded Flow divider TQ see sect. Leak-free seated valves, e.g. acc. to D 77 or D 700 designs of equal value, for blocking the cylinder lines at "Stop" in any desired raised intermediate position. These prevent any uncontrolled volume exchange via from the higher to the lower loaded cylinder, and thus also prevents one cylinder moving in and the other moving out. If travel is always against the final stop without an interim stop, then the valves are not required. Lift/lower valve type HSV acc. to D 70. The lowering speed can be adjusted by means of the throttle Dr.