USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102



Similar documents
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Meaco 30L and Meaco 40L dehumidifier instruction manual

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Meaco 10L Basic Small Home Dehumidifier

Operating Instructions Split System Air Conditioner

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

PORTABLE AIR CONDITIONER

Dehumidifier Users manual. For Models: DH45S DH65S

Important Safeguards

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL

INSTRUCTION MANUAL REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Instruction manual for Firstline FCS12000CH

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

PORTABLE AIR CONDITIONER

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Room Air Conditioners

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

SILENT10 PORTABLE AIR CONDITIONER USER MANUAL

Split Type Room Air Conditioner. KSWM units

Portable Evaporative Air Cooler with Heater for indoor use. OWNER S MANUAL Read and save these instructions before use.

3.6 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

VACUUM CLEANER INSTRUCTION MANUAL

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

PORTABLE AIR CONDITIONER (LOCAL)

Portable Air Conditioner INSTRUCTION MANUAL

Meaco DD8L desiccant dehumidifier Instruction Manual

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) (ROI) White series

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER

3.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL HMBR350BE HMBR350SE

REFRIGERATOR INSTRUCTION MANUAL. Model No.: MCBR170W/B/S

SAFEGUARDING THE ENVIRONMENT

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2

Please read and keep these instructions. Run water through your machine before first use

Get Me Cool Now Portable Air Conditioner User s Manual

Split Air Conditioner

WINDOW ROOM AIR CONDITIONER

2KW CERAMIC HEATER DHCER20. User Manual

INFRARED QUARTZ WALL HEATER

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

Operating Instructions Air Conditioner

- 2 - IMPORTANT SAFETY REMINDERS

Built in Fridge Freezer LAM6800. Installation & Operating Instructions

Contact Details. Please note that some of the contact details on this PDF document may not be current.

USER S MANUAL HSC-24A

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Air Conditioner. Portable BTU/h 2.9kW INSTRUCTION MANUAL CWAC11 CPIN Important! Please read these instructions carefully.

CARING FOR YOUR WATER HEATER

MIST DECORATIVE LAMP WITH ESSENTIAL OIL DIFFUSER

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Dehumidifier D 850E. - Instruction manual version 02

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

MFU200 Integrated Under Counter Larder Fridge

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

R410A SPLIT SERIES DC INVERTER

Use & Care Guide AIR CONDITIONERS ACM052 ACM062 ACM072

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Multifunction. vax.co.uk Series. What s your Vax model number?

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

GENANO 4500 MEDICAL AIR PURIFICATION DEVICE

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

2-SLICE COOL TOUCH TOASTER

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safely precautions,

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

Installation Instructions and Owner's Manual. Double-Hung Windows Room Air Conditioner. This manual must be left with the owner of the equipment.

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

4.4 CU.FT. REFRIGERATOR INSTRUCTION MANUAL HMBR445BE HMBR445SE

Wine Cooler with Thermo-Electric Cooling & Heating Technology

Room Air Conditioners

55CM Wide Freestanding Under Counter Larder Fridge. Instruction Manual

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

Reverse Cycle Inverter Split System Air Conditioner

GenStore Archive Cabinet

Nokia Bluetooth Headset BH-607. Issue 2. 1

SWIMMING POOL HEAT PUMP

BUILT-IN WINE & BEVERAGE COOLER WITH DUAL TEMPERATURE ZONES INSTRUCTION MANUAL. Model No.: MCWBC77DZC

Operations Manual Blast Chiller

Troubleshooting Your Refrigerator

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

Room Air Conditioners

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Transcription:

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE

SAFETY NOTES THIS DEHUMIDIFIER IS INTENDED FOR DOMESTIC USE ONLY. 1. Do not connect to any AC socket outlet that is damaged *. 2. Do not use with extension leads and multi-way adapters. 3. Ensure hands are not wet when inserting the plug into the power socket. 4. Do not use in the following locations:- Next to a source of fire. An area where oil is likely to splash. An area exposed to direct sunlight. An area where water is likely to splash. Near a bath, shower or a swimming pool. In a greenhouse. An area where flammable gases or liquids are present. 5. Never insert your finger or any foreign objects into the air outlet. Take special care to warn children of these dangers. 6. Always store the unit upright in order to maintain the compressor in a proper working condition. If not, leave the unit upright for at least 24 hours before operating. 7. Always unplug the unit before cleaning. 8. Do not cover the unit or place any object on the control panel 9. Do not obstruct the air inlets/outlets of the appliance. 10. Do not allow children to play with or climb on the machine. 11. If a fault develops or if servicing is required, this must only be carried out be a qualified service engineer. 12. If the supply cord of this appliance becomes damaged, it must be replaced by a qualified engineer. 13. This appliance is fitted with an approved BS 1363 13A 3 pin plug and a 13A BS 1362 fuse. In the event of either requiring replacement ensure that equivalent rated and approved components are used. See plug replacement details below. PLUG REPLACEMENT If the plug is damaged and requires replacement, follow the wiring instructions supplied with the new plug. 1. The green and yellow wire must be connected to the terminal marked with the letter E or the earth symbol. 2. The blue wire must be connected to the terminal marked with the letter N. 3. The brown wire must be connected to the terminal marked with the letter L. 4. A 13 amp plug to BS 1363 must be fitted a 13 Amp fuse to BS 1362. * For your safety and protection, this unit is earthed through the power cord plug when plugged into a matching wall socket. If you are not sure whether the wall sockets in your home are properly earthed, consult a qualified electrician. Do not use plug adaptors or extension cords with this unit.

IDENTIFICATION OF PARTS CONTROL PANEL CONTINUE With the control knob in this position, the machine will run continuously NORMAL In this position the humidity is controlled between 50% R.H. and 60% R.H. DEFROST LED When the machine is in defrost mode, this LED will be illuminated. OFF POSITION Machine will stop running Control Knob BUCKET FULL LED When the water tank if full this LED will illuminate and the machine will stop RUNNING LED This LED will illuminate when the machine is running.

OPERATING INSTRUCTIONS 1. Ensure the plug on the dehumidifier is inserted fully into a working power socket. 2. It is important to ensure that the water tank is correctly positioned within the unit and that it is not full of water. If the Bucket Full indicator is illuminated when the unit is plugged in for the first time, pull the water tank out of the unit slightly and push it back into it s proper position. 3. Turn the control knob to the desired humidity level (this is usually the position marked NORMAL and is equivalent to between 50% and 60% R.H.). 4. If the surrounding humidity level in the room is higher than the level set on the machine, the machine will start up and the green machine running LED will illuminate. Any moisture in the air drawn through the machine by the fan will form as water droplets on the condenser within the machine. These water droplets will eventually collect in the water tank in the front of the machine. The rate at which the water is collected in the tank is dependant on a number of factors, such as the room temperature, the size of the room and the source of the humidity. It is a known fact that at low room temperatures the extraction rate is also low. 5. When the machine brings the humidity level in the room down to the level set on the machine, it will switch off. 6. If the control knob is left in the set position, the machine will continue to cycle on and off, keeping the surrounding humidity level close to the level set on the machine. 7. If the control knob is turned to the CONTINUE position, the machine will run continuously. 8. When the water tank is full the machine will stop and the Bucket Full light will illuminate. The water tank should be carefully removed from the machine by sliding it outwards from the front of the machine and it should be emptied. When the empty tank is replaced properly into the machine, the machine will start up and run normally. Note: When the Bucket Full light is on after the machine has been running for some time, the water should be emptied out from the tank. If the tank is not emptied and replace correctly in the unit, the appliance will not operate. 9. DEFROSTING When the machine is operated at low temperatures (less than 12 C) the surface of the evaporator may accumulate a layer of frost which would reduce the efficiency of the machine. When this happens the machine will go into periodic defrost mode automatically. The defrost LED on the front of the machine will illuminate. The time taken to defrost may vary. The machine will operate in temperatures down to 5 C. If the machine freezes up it should be turned off at the power supply and re-started. If the surrounding temperature remains below 5 C the machine should be switched off. CONTINUOUS DRAINING OPTION When the dehumidifier is used in a situation where it is neither desirable nor convenient to keep having to empty the water tank, there is a facility to enable the unit to be continuously drained. This will allow the unit to be run continually without the need to periodically empty the water tank. To use the continuous draining facility, the following procedure should be used. 1. It is necessary to obtain a length of flexible PVC hose having a bore (internal) diameter of 13mm. The length of the hose should be sufficient to reach a suitable drain or a water container in which the water may be collected. 2. The water tank on the machine must be empty and fitted correctly in position on the machine. 3. Remove the domed knob on the rear of the machine that screws over the continuous drainage outlet, by rotating it anti-clockwise. 4. Remove the rubber bung from the drainage outlet and keep in a safe place. 5. Push one end of the drainage hose (as detailed in 1 above) firmly onto the end of the drainage outlet. 6. Place the other end of the drainage hose into a suitable container (or into a drain), ensuring that no part of the hose is higher than the drainage outlet on the machine. Ensure there are no kinks or blockages in the hose. 7. When reverting back to tank draining on the machine, remove the drain hose from the outlet, replace the rubber bung into the drain outlet and replace the domed knob on the drain outlet by screwing it in place in a clockwise direction.

PRECAUTIONS Do not pull on the mains lead when removing the plug from the power socket. Do not use sprays cans containing insect repellent, paint or oil near the machine as it could damage the plastic parts or cause a fire Do not place the machine on an uneven floor as it could cause noise, vibration and spillage of water Keep the unit at least 20cm from a wall to dissipate the heat. Clothes may be hung no closer than 50cm above the machine It is dangerous to put any object into the intake and outlet grilles of the machine Closing doors and windows will maximise the efficiency of the unit Do not expose the unit to any sources of heat When moving or storing the unit do not lay it on it s side or turn it upside down.

MAINTENANCE IMPORTANT Make sure the machine is un-plugged from the power socket before carrying out any cleaning or servicing. CLEANING THE CABINET 1. Wipe the cabinet of the unit with a soft, clean and dry cloth. 2. If the cabinet is very dirty, use a mild detergent applied with a damp cloth. Do not use harsh abrasives or solvents. Wipe off the detergent with a clean damp cloth and then wipe with a dry cloth. 3. Do not wash the machine with water or a hose, as water could enter the machine and cause a fault or create an electric shock hazard. AIR FILTER CLEANING The built in air filter removes dust particles and impurities from the air passing through the machine. When the filter begins to become clogged with dust, the efficiency of the unit is reduced and the filter should be cleaned. The intervals between cleaning will depend on how much dust is in the environment where the dehumidifier is used. To remove the filter, first remove the water tank from the front of the unit and tip the unit backwards about 15. The filter is located behind the front grille and should be pulled downwards to remove. If the filter is heavily contaminated it should be cleaned first with the aid of a vacuum cleaner. The filter should then be washed with warm water and a mild detergent, rinsed with clean water and allowed to dry before placing back in the machine. TROUBLESHOOTING If you have any minor problems with the dehumidifier check the items mentioned below before contacting the helpline. Problem Possible Cause Solution Both fan and compressor not working No power to unit Check power to the socket Check power is switched on. Compressor of fan not working Motor failure Unit is in time delay period Faulty electronics Wait Not Collecting Water Air intake filter blocked Refrigerant is low. Temperature and Humidity are too low Clean filter Normal function Noisy Unit Floor is uneven Place on a level surface. Condenser is frozen Filter is dirty Temperature is too low Clean filter Switch off and wait for temperature to rise Leaks Water tank is not installed properly Micro switch failure Unit has frozen Fit properly Unplug and allow ice to melt

STORAGE OF THE UNIT If the unit is not going to be used for some time it should be stored in an upright position in a cool dry place and covered to protect the unit from dust. SERVICING If a fault develops or if servicing is required DO NOT attempt to do this yourself. This should ONLY be carried out by a qualified service engineer. SPECIFICATION MODEL DHMD025 POWER 220-240V / 50Hz MOISTURE REMOVAL (MAX) 10 L/D (30 C 80% RH) POWER INPUT 220W REFRIGERANT R-134a, 160g OVERALL SIZE (H x W x D) 440 x 295 x 280mm WEIGHT 11.5kg OPERATING TEMPERATURE 5 C to 35 C NOTE: Waste electrical products and products containing refrigerants should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice. GET Plc., Key Point, 3 17, High Street, Potters Bar, Herts. EN6 5AJ Helpline Telephone No. 0121 565 7770 AR1129 Ed.A