SmartLogger1000. Quick Installation Guide. Issue 05. Date 2013-12-15 HUAWEI TECHNOLOGIES CO., LTD.



Similar documents
Application/Connection Examples

WEB log. Device connection plans

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Network Camera. Quick Operation Guide V4.0.1

Quick Start Guide. RV 120W Wireless-N VPN Firewall. Cisco Small Business

WEB log. Device connection plans

ProVisual AC-8000P. User Manual. For the optimal use and maintenance of the product, Please read the manual carefully before using it.

Aolynk DR814Q ADSL2+ Broadband Router Quick Start

C n o t n e t n e t n s

Acano solution. Acano Solution Installation Guide. Acano. January B

1 Serial RS232 to Ethernet Adapter Installation Guide

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

ON HOLD ANNOUNCER. Once you receive your audio announcer, check the packaging to ensure that all of the following items are enclosed:

IP Indoor High Speed Dome. CAM-6500 series. Ver Quick Installation Guide

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

PT Mbps Powerline Adapter. User Guide

Energy Communication Unit (ECU)

The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.

Users manual. TCW181B-CM_R1 Page 1

LBNP RS-232/485/422 serial device server. User manual

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

Wind Sensor W-RS485 with RS485 Interface

Energy Communication Unit (ECU)

BACnet Automation Interface Module (Network Version)

VTO6xxx. IP door stations. User manual

Setting Up the Cisco Unified IP Phone

DVG-2101SP VoIP Telephone Adapter

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

Before You Begin You must have at least the following: Web Browser Wired Hub/Switch/Router OR Wireless b Router CD-ROM Drive

Extender for HDMI Long Range. GTV-HDMI-CAT5LR. User Manual

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

(IR) Bullet LPR/ANPR Network Camera

Wireless Router Setup Manual

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

Installation Guide Solar Connect-11

Quick Start Guide. Cisco SPA100 Series Analog Telephone Adapters. SPA112 Two Port Phone Adapter SPA122 ATA with Router

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

EMBEDDED ACCESS CONTROL Hardware Installation Guide

INSTALLATION AND OPERATION MANUAL

3.5 EXTERNAL NETWORK HDD. User s Manual

16/32 Channel 1U Rack Mount CCTV Power Supply

Digital Keypad Use s Manual

Check Your Package Contents. CD-ROM containing Manual and Warranty

Raritan AMS Series Intelligent Electronic Asset Management

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

Quick Start Guide. WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide. Cisco Small Business

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

Part Number: HG253s V2 Home Gateway Product Description V100R001_01. Issue HUAWEI TECHNOLOGIES CO., LTD.

PCS300 Universal IP Reporting Module V1.0

Disclaimers. Important Notice

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

SANGFOR SSL VPN. Quick Start Guide

EDI Distributor Control Interface Wiring and Setup Instructions

How To Wire Wireline Cable To A Cell Phone (New Zealand)

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide.

Quick Instructions for Setting up Swe-dish.

IP DSLAM IDL Quick Installation Guide

White Paper on Video Wall Display Technology in Videoconferencing HUAWEI TECHNOLOGIES CO., LTD. Issue 01. Date

Setup guide. point to point wall plate extenders

P Quick Start Guide. VoIP Analog Telephone Adaptor DEFAULT LOGIN. IP Address Password Version /2007 Edition 1

Waveguide Access Point WGA631. Product Guide

How To Use Mview On A Powerline 2.2 (Powerline) On A Pc Or Macbook 2 (Powerplst) On An Iphone Or Ipa 2 (Aldo) On Your Iphon 2 (

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Meraki MX50 Hardware Installation Guide

User s Manual of Web monitor HMI-901

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

HG658c Home Gateway. User Guide HUAWEI TECHNOLOGIES CO., LTD.

Welcome. Unleash Your Phone

Huawei NE5000E 400Gbps Flexible Line Processing Unit

10/ English Edition 1. Quick Start Guide. NWA1100N-CE CloudEnabled Business N Wireless Access Point

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

How To Set Up A Power Logger On A Pv Data Logger On An Ipad Or Ipad (S-We01S) With A Wifi Kit (Swe01) With An Ipa Data Logger (S01S Or S01

Table of Contents. Creating a VC1000 Network... 3

1CH VIDEO SERVER INSTALLATION GUIDE. Please read instructions thoroughly before operation and retain it for future reference.

NeoGate TA Series Quick Installation Guide

Setting Up the ZigBee Ethernet Gateway

Quick Start Guide. RV0xx Series Routers

Phone Adapter. with 2 Ports for Voice-over-IP. Installation and Troubleshooting Guide. Model No. PAP2 Ver. 2. Voice

NeoGate TG Series Installation Guide

BEC 6200WZL. 4G/LTE Cellular Broadband Router. Quick Start Guide

HG659 Home Gateway. User Guide HUAWEI TECHNOLOGIES CO., LTD.

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

TL-PS310U Single USB 2.0 Port MFP and Storage Server

Raritan AMS Series Intelligent Electronic Asset Management

IP POWER 9258 USER MANUAL IP POWER 9258 USER MANUAL

Broadband Router ESG-103. User s Guide

GEU Port Gigabit Switch

HUAWEI 9000 HD Video Endpoint V100R011. Security Maintenance. Issue 02. Date HUAWEI TECHNOLOGIES CO., LTD.

SL1100 Installation Instructions. This Installation Packet is Organized into Five Chapters:

E E V R E - R S - O S L O A L R

Time and Attendance System

Setting Up the Cisco Unified IP Phones

PD-300 SERIES 2 X 20 LCD CUSTOMER DISPLAY Rev. C0

If you need additional assistance please contact our Technical Support Center at 24 hours a day, 7 days a week.

Transcription:

Issue 05 Date 2013-12-15 HUAWEI TECHNOLOGIES CO., LTD.

2013. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademarks and Permissions and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders. Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied. Huawei Technologies Co., Ltd. Address: Website: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China http://enterprise.huawei.com i

The quick installation guide introduces the SmartLogger1000 (SmartLogger) in terms of installation, electrical connections, and initialization parameters. For more detailed information, see the related user manual. You can download the latest documents from http://enterprise.huawei.com. Appearance Front View of the Shell Bottom of the Shell The following table describes functions of each port of the SmartLogger, as shown in Table 1-1. Table 1-1 Port description Port Function Description POWER Power supply 12 V DC. FE Ethernet Connects to PC or routers. RS232 RS232 Connects to external RS232 devices (reserved). AI Analog input 12 V current-type signal (reserved). 1

Port Function Description DI Digital parameter input Connects to the power grid scheduling signal controlled by dry contacts. DO Digital parameter output Relay output. S0.In Connects to pulse output power meters. Reserved. CAN CAN Reserved. COM1 COM3 RS485 Supports three RS485 ports and connects to inverters and environmental monitoring instruments. Checking Deliverables After unpacking the SmartLogger, check whether deliverables are intact and complete. If any damage is found or any component is missing, contact the dealer. No. Quantity Description 1 1 SmartLogger 2 1 Adapter (adapter type depends on the country specified in the order) 2

No. Quantity Description 3 1 Network cable (2.2 meters long) 4 8 Terminal block 5 2 Expansion tube 6 2 Screws (used to secure the SmartLogger to the wall) 7 1 Auxiliary documents (including the quick installation guide in paper copies and user manual in CD-ROM) Tools Prepare tools required for installation and electrical connections. Hammer drill Diagonal pliers Wire stripper Rubber mallet Guarded blade utility knife Cable cutter Vacuum cleaner Marker Measuring tape Plumb line Safety goggles Anti-dust respirator Determining the Installation Position Comply with the following requirements when determining the installation position for the SmartLogger: Do not install the SmartLogger outdoors because it is protected to IP20. Install the SmartLogger in a dry environment to protect it against water. The ambient temperature should range from -20 C to +60 C. 3

The communication distance for the RS485 port should be less than 1000 m and for the Ethernet less than 100 m. Install the SmartLogger at an appropriate height for the user's ease to view and operate on the monitoring panel. Do not place the SmartLogger upside down. Ensure that the heat dissipation holes are facing upwards, preventing dust from entering the SmartLogger and reducing its service life. If you install the SmartLogger on a wall or along a guide rail, the area for connecting cables should be downwards. The SmartLogger is at least 100 mm away from the neighboring objects on both sides, the top side, and the bottom side respectively. Installing the SmartLogger on a Desk 1. Take the SmartLogger out of the package. 2. Place the SmartLogger on a horizontal desk. Mounting the SmartLogger on a Wall 1. The following figure shows the position of the installation holes. Use a plumb line to ensure that the centric line of the hole is vertical to the ground. 4

2. Drill holes by using a hammer drill and install expansion tubes and screws. Table 1-2 describes the operations shown in the preceding figure. Table 1-2 Drilling holes and installing expansion tubes and screws Step Operation 1 Put a hammer drill with a Ф6 drill bit on a marked hole position perpendicularly against the wall and drill holes with a depth of 24-25 mm. 2 Vertically insert an expansion bolt into a hole, and knock the expansion bolt completely into the hole using a rubber mallet. 3 Insert the screw into the expansion tube until the screw heads are 7.5 mm to 8 mm away from the wall. Install the expansion tubes and screws The guide rails are not delivered together with the SmartLogger. If you need to mount the SmartLogger along a guide rail, prepare a 35 mm wide guide rail. 5

1. Hold both sides of the SmartLogger, keep it parallel with the guide rail, and then tilt it slightly to insert its upper hooks into the guide rail. 2. Hold the two lower corners of the SmartLogger, pull it downwards appropriately, and then push it towards the guide rail. When you hear a click sound, the SmartLogger is successfully mounted along the guide rail. 6

Electrical Connections This section describes how to connect the SUN2000, SUN8000, and an environmental monitoring instrument to the COM port of the SmartLogger by using shielded cables (recommended CAT 5E outdoor shielded network cable). The RS485 communications port for the SUN2000 is an RJ45 port, which is connected over a crystal plug. Table 1-3 lists the cable colors and functions (side view without the fastener). Table 1-3 Cable colors and functions Category Color Function 1 White and orange RS485A, RS485 differential signal + 2 Orange RS485B, RS485 differential signal - 3 White and green PGND 4 Blue RS485A, RS485 differential signal + 5 White and blue RS485B, RS485 differential signal - 7

Category Color Function 6 Green PGND 7 White and brown PGND 8 Brown PGND The following figure shows the RS485 wiring terminals of the SUN8000. Ports 07, 08, 09, 10, 11, and 12 are communications ports. Table 1-4 describes the functions of these ports. Table 1-4 Port description No. Function Description 07 Reserved Reserved 08 Reserved Reserved 09 N485A_OUT RS485A, RS485 differential signal + 10 N485A_IN RS485A, RS485 differential signal + 11 N485B_OUT RS485B, RS485 differential signal - 12 N485B_IN RS485B, RS485 differential signal - There are three COM ports for the RS485 communications of the SmartLogger: COM1, COM2, and COM3. 8

Table 1-5 describes the definition of the COM ports. Table 1-5 COM port description Port Identifier Function NC NC: Reserved COM1 port NC NC: Reserved - -: RS485 differential signal - + +: RS485 differential signal + COM2 port COM3 port - -: RS485 differential signal - + +: RS485 differential signal + - -: RS485 differential signal - + +: RS485 differential signal + Connect the SmartLogger to multiple inverters in daisy chain, that is, first connect the RS485 OUT port of one inverter to the RS485 IN port of another inverter and then connect the RS485 port of the first inverter to the COM port of the SmartLogger. 9

A maximum of 20 devices are in one daisy chain. If an environmental monitoring instrument is to be connected, connect it at the end of the chain. Set the address for the environmental monitoring instrument to 1. Set Match Resistance of every inverter at the end of the daisy chain to Connect in Comm. Param. (For details about this, see the SUN2000 (8KTL-25KTL) User Manual. The addresses for all devices in the daisy chain should be within the searching scope set in the SmartLogger and they must differ from each other. Otherwise, the communications would fail between the device and the SmartLogger. Baud rate of all the devices in one daisy chain should stay consistent with those of the SmartLogger. Connecting the SmartLogger to a Ripple Control Receiver In Germany and some European areas, a ripple control receiver is used to convert a power grid scheduling signal to a dry contact signal, in which a dry contact is required. The following figure shows the DI ports on the SmartLogger. Table 1-6 describes the definition of the DI ports. 10

Table 1-6 DI port description Port GND1 Functions Active power reduction 1 DI_1 2 DI_2 3 DI_3 4 DI_4 GND2 Reactive power compensation The following figure shows how to connect the Smart Logger to the ripple control receiver. When active power remote control and reactive power remote control are supported, only one out of the four outputs of each ripple control receiver can be closed Power-on Process Power on the devices in the following sequence: Inverter > SmartLogger > Monitoring terminal. The monitoring terminal refers to a PC where the NetEco1000 is installed. 11

Step Operation 1 Check and ensure all cables are correctly connected and secured before powering on the SmartLogger. 2 Start the inverter and correctly set the communications parameters (including Address, and Baudrate) on the monitoring panel. For details about how to set the communications parameters, refer to Setting Communications Parameters in the SUN2000 (8KTL-25KTL) User Manual and SUN8000-500KTL User Manual. 3 Connect the output terminal of the power adapter for the SmartLogger to the power port POWER and the input terminal to the AC socket. 4 Set the search address segment and baud rate for the RS485 port on the SmartLogger monitoring panel. If the SmartLogger is powered on for the first time, set the search address segment and baud rate for the RS485 port in the Wizard. If it is not powered on for the first time, set the parameters in the Comm. Param. under the Settings. 5 Wait for the SmartLogger to search for inverters. After the search is completed, the SmartLogger automatically connects to all inverters. Alternatively, you can skip this operation and manually search for, add, or delete inverters in follow-up operations. 6 (Optional) Add the environmental monitoring instrument manually. NOTICE Before you add the EMI manually, log in to the WebUI and set related parameters. 7 (Optional) Start the monitoring terminal and set Ethernet and NetEco parameters on the SmartLogger. When starting the SmartLogger, use only the 12 V power adapter shipped along with the shell. If adapters of other models are used, the SmartLogger may be damaged. Log into the SmartLogger on the monitoring panel. When you log in to the Settings page or Maintenance page, an identity authentication is required. The initial password is 000001. Change the password as soon as possible to ensure the security of the user account. For details about how to change the password, refer to SmartLogger1000 User Manual. Setting the Initialization Parameters for the SmartLogger The following figure shows how to set the initialization parameters for the SmartLogger. 12

Connect a PC to the SmartLogger You can connect a PC to the SmartLogger by a network cable or through network devices, such as a hub or a router. 13

1. When setting the Internet protocol, set the IP addresses of the PC and the SmartLogger in the same network segment. For example, if the IP address for the SmartLogger is 192.168.0.10, the IP address for the PC can be 192.168.0.11. The subnet mask and the gateway of the PC should stay consistent with those of the SmartLogger. 2. Log into the WEBUI through a browser. The address for the WEBUI is by default the same as the IP address for the SmartLogger, that is http://192.168.0.10. 14