CG-1171-20 PTFE Diaphragm Liquid Transfer Pump



Similar documents
SunMaxx Solar Filling Station Operating Instructions

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Assisted lift operated 2/2-way solenoid valves Type EV250B

Solenoid valves 2/2-way direct-operated Type EV210A

Your safety and the safety of others are very important.

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

- Do not immerse cords, pump or any electrical wire or device in water or other liquid.

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

Oil and Coolant Circulating Heating System. Model - OCSM

OPL BASIC. Dosing System for Professional Laundry machines. Contents

- 2 - IMPORTANT SAFETY REMINDERS

National- Spencer Inc.

Portable Air Conditioner

CappController Pipette Controller. Operation Manual Version:

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Operation Manual. Diaphragm pumps 1-headed MPC 301 E

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Instructions For SF 6 Refill Kit

NITROUS TRANSFER PUMP INSTRUCTIONS

CARING FOR YOUR WATER HEATER

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Instruction Manual Differential Pressure Transmitter

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

1. Description. 2. List of Accessories included A B C F G H

USER S MANUAL HSC-24A

VACUUM CLEANER INSTRUCTION MANUAL

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

Doc. No. NDP 015M-15 MAINTENANCE MANUAL YAMADA AIR-OPERATED DIAPHRAGM PUMPS. DP-10 series

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

Manual Ranging MultiMeter

Operating Instructions Drill rig DRU160

PORTABLE AIR CONDITIONER

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

UNITOR VACUUM cleaners

Solenoid valves Type EVU

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

SHHH AIR COMPRESSOR Model Nos. SHHH2 - SHHH2/9 - SHHH3/9 - SHH3/24

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

Thermostatic valve Type AVTA

B150 Series Commercial Brewer. Direct Plumb Kit

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Please also see 10 golden rules for correct Saniflo installation on

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

Concremote calibration box

Meaco 30L and Meaco 40L dehumidifier instruction manual

Installation, Operation, Repair and Parts Manual

PORTABLE AIR CONDITIONER

Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

MP-4V Heavy Duty Riveter / 39048

Hydraulic Trouble Shooting

SHOT BLAST CABINET MODEL NO: CSB20B

Doc. No. NDP 009M-32 MAINTENANCE MANUAL YAMADA AIR-OPERATED DIAPHRAGM PUMPS. NDP- 5 series NDP-15 series

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Streaming Potential System (SPT1000, SPD1000)

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Chapter 7 Hydraulic System Troubleshooting

1/3 HP Submersible Sump Pump with Vertical Float Switch

PET-10 INSTRUCTION MANUAL PRESSURE TANK

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Installation and safety instructions for AC/DC built-in devices

Waste Oil Handling, Spill Containment & Lighting

ALMATEC Series CX CX 10 CX 130

SWIMMING POOL HEAT PUMP Owners Manual

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

How To Size A Stenner Pump

INTERNATIONAL FIRE TRAINING CENTRE FIREFIGHTER INITIAL PUMPS AND PRIMERS. Throughout this note he means he/she and his means his/hers.

ClearView 100. Instruction Manual

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

Stove Guard Kit User Manual

Graymills. Air Operated Double Diaphragm Pumps. Operations and Maintenance Instructions

Installation Operation Maintenance Troubleshooting Version 2.1, Apr/09 DAYTONA

Introduction. Concept. Advantages PRIMING OF BEARINGLESS PUMP SYSTEMS

Leak Detection System

MODEL J SERIES CONVERTER

SMD Rework Station TABLE OF CONTENTS

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Instruction manual for Firstline FCS12000CH

sealed close coupled pumps

3 WATT LED SPOTLIGHT Model No. SLM

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Transcription:

3800 N. Mill Road Vineland, NJ 08360 Phone: 800.843.1794 Fax: 800.922.4361 CG-1171-20 PTFE Diaphragm Liquid Transfer Pump This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid property damage, possible injury or death. You have selected a KNF Diaphragm Pump. The following tips will help you operate it safely and reliably over a long period. It is essential that you read these Operating Instructions before putting the pump into service. Follow them for all applications as they help prevent dangerous situations and damage to the pump and system. www.cglifesciences.com technical-service@cglifesciences.com

Table of Contents No Section Page 1 Delivery Contents 2 2 Description 3 2.1 General Notes 3 2.2 Areas of Application 3 2.3 Features 3 2.4 Operating Principles 3 3 General Safety Instructions 3 4 Transport and Storage 3 5 Setting Up 3 5.1 General Advice 3 5.2 Operating Conditions 3 6 Pump and Controls 3 6.1 Pump 3 6.2 Controls 4 No Section Page 7 Installation 4 7.1 Installation 4 7.2 Installing the Liquid Pump 4 7.3 Operation 4 7.4 Removing the Pump 4 8 Error Messages 5 8.1 Possible LED Error Messages 5 9 Troubleshooting 5 10 Technical Data 5 10.1 LIQUIPORT 5 10.2 CE-Marking 5 11 Exploded View 6 11.1 Spare Parts List 6 12 Return Request/Inquiries 6 1 Delivery Contents Pump Power Adaptor -- 2 --

2 Description 2.1 General Notes It is essential that you read these Operating Instructions before putting the pump into service. Follow them for all applications as they help prevent dangerous situations and damage. The LIQUIPORT diaphragm transfer pumps have been developed by KNF especially for laboratory and industrial applications that demand high chemical resistance, reliability and simple operation. 2.2 Areas of Application Transfer of neutral and aggressive liquids in laboratories, industrial areas and systems. 2.3 Features of the LIQUIPORT They are self-priming, can operate dry and are quiet. By using chemically resistant materials such as PTFE, PVDF, FFPM etc. for parts that come into contact with the liquid, almost all neutral and aggressive liquids can be handled. Due to the compact construction it requires very little work surface. The flow can be adjusted manually on every model. Maintenance free. 2.4 Operating Principles The LIQUIPORT pump is an oscillating positive displacement pump. An eccentric converts the rotary motion of the drive shaft into an oscillating movement of a connecting rod, which in turn transmits its motion to the diaphragm. In combination with inlet and outlet valves, this diaphragm motion produces the pumping action. 3 General Safety Instructions WARNING Ensure the pump is only used for its intended purpose. The unit may not be used in areas in which there is a danger of explosion. Only connect the pump into fused sockets. Observe all relevant safety and accident prevention regulations. Before working on the pump, disconnect it from the power supply! Only qualified people may open the parts of the equipment that contain live parts. The Operating Instructions should always be kept readily available and near the equipment. When cleaning the unit, make sure that no liquid enters the housing. Use only genuine spare parts from KNF. If you return your KNF pump for repair, please state for what medium it has been used for, especially if this is very aggressive/dangerous. If the pump has been used for dangerous or highly aggressive media, it must be cleaned before being returned. 4 Transport and Storage When packing the pump, make sure that it is properly secured inside the package. The package must be strong enough to withstand any rough treatment it may receive during transport. Use original packaging 5 Setting Up 5.1 General advice As you set the pump up please pay attention to the following points. Ensure that the pump is on a stable surface and is standing upright on its 4 rubber feet. The pump can be mounted from underneath with four screws. All special safety instructions for the liquid/gas being handled must be observed. The head materials, compression fittings and tubing must be resistant against the liquids being pumped. ➊ Check that the connections between the compression fittings and Teflon tubing are secure. 5.2 Operating Conditions Permissible ambient temperature +5 to +40 C. The presence of solids in the medium being handled may lead to faulty operation of the pump. Permissible temperature of the medium being handled is +5 to +80 C. The pump should not operate against a closed system. The pump is limited against which pressure / vacuum it can start running. The ideal conditions are when the pump can start at atmospheric conditions as then the priming is guaranteed. 6 Pump and Controls 6.1 Pump Pump Head RC-Plug (only RC Version) Power Supply -- 3 --

Standby 6.2 Controls On/Off Button Extern 7.3 Operation ➊ Select the flow rate Note: If the system should prime fast then select the highest possible flow rate. ➋ Start the priming/pumping by pressing the ON/OFF button (STANDBY goes off). ➌ Adjust the flow by turning the knob. 7.4 Removing the Pump ➊ After using the pump rinse the pump and system with a neutral liquid and then pump it empty. ➋ Remove the adaptor from the plug. Knob LED Minimum Maximum Position Description Function 1 ON/OFF Button Turns the pump on and off 2 EXT Lights up when analog signal is being used (RC- Version) 3 MAX Maximum flow 4 Knob Adjusts the flow from 10% to 100% 5 MIN Minimum flow 6 LED Indicates the flow rate 7 Standby Standby lights up green, as soon as the pump is plugged in. Pump is not running. 7 Installation 7.1 Installation Refer to the points in Section 5. 7.2 Installing the LIQUIPORT The pump is delivered ready to use. ➊ Connect the 1/4 Teflon tubing. ➋ Plug the adaptor in. The Standby lights up green. -- 4 --

8 Error Messages 8.1 Possible LED Error Messages In order to cancel the error message press the On/Off button. Error No 1: LED s blink, Standby symbol lights up. Pump turns off after 5 seconds. Cause: Pump was running against pressures over the allowed limit. Solving the Problem: ➊ Reduce the pressure. ➋ Change the flow rate. If the cause of error No 1 is not removed within 5 seconds, then the pump goes to error No 2. Error No 2: All LED s blink, Standby symbol lights up. Pump turns off. Cause: Pump was running against pressures over the allowed limit. Solving the Problem: ➊ Reduce the pressure. ➋ Change the flow rate. ➌ Start the pump. 9 Troubleshooting Before working on the pump, ensure the power supply is isolated. Motor Fails To Start Pump is not connected to power supply. Power supply is switched off. The pressure in the delivery line from the pump is too high. Pump is on STANDBY ON-/OFF button not pressed. External controlling is connected without input signal. Pump Not Sucking Liquid In Suction side of pump is not connected. Liquid level in container is too low. Hose connections are leaking. A system valve is closed, or blocked. The pump head is filled with gas. The gas pressure after the pump can not be overcome because of its compressibility in the working chamber. Diaphragm and/or valves are worn out or dirty. Flow Rate, Suction Height, or Pressure Height Is Insufficient. The periphery installation contains components (hoses, valves, filters, etc ) which create too much resistance. Hose connectors are not tight. Diaphragm or valves are worn out or are covered in dirt. 10 Technical Data 10.1 LIQUIPORT Flow Rate 1 (L/min) 0.5 to 3 MAX Suction (ft H 2 0) 10 MAX Pressure Head (PSIG) 14.7 Pump Weight 2 (gram) 1,500 MAX Ambient Temp ( C) +5 to +40 MAX Temp of Liquid ( C) +5 to +80 MAX Viscosity of Liquid (cst) 150 Head Material Polypropylene Diaphragm Material PTFE Valves FFPM Protection Type IP65 Protection Class III 1 2 Measured with water at 20 C and pressure 0mWg. The weight can vary depending on the individual version. 10.2 CE-Marking The LIQUIPORT -Diaphragm liquid pumps are in accordance with the following standards: EN 61010 1 EN 60529 EN 61326 1 EN 55022 EN 61000-4-6 EN 61000-4-3 EN 61000-4-4 EN 61000-4-2 EN 61000-4-5 EN 61000-4-11 EN 61000-3-2 EN 61000-3-3 -- 5 --

11 Exploded View 12 Return Requests/Inquiries Direct all warranty and repair requests to CHEMGLASS Technical Service for instructions before returning any unit for repair or evaluation. We will send you a Return Instruction Sheet for guidance on the proper marking, packing and documentation requirements. Important information conforming to the Right To Know act, such as a Material Safety Data Sheet may be required. Products shipped to CHEMGLASS must have a Return Authorization Number (RA#) marked on the outside of the package. Otherwise the shipment will be refused by our receiving department. Please contact CHEMGLASS Customer Service for RA#. For service or parts, contact: Chemglass, Inc 3800 North Mill Road Vineland, NJ 08360 US and Canada Phone: 1-800-843-1794 Fax: 1-800-922-4361 customer-service@chemglass.com www.chemglass.com Position Description 10 O-Ring 20 O-Ring 30 Resonating Diaphragm 40 Valve Plate 50 Diaphragm 60 Head Screws 11.1 Spare Parts List Order Quantity Per Position Description Number Pump Head 60 Head Screws 019 698 4 30 Resonating Diaphragm, PTFE 068 513 1 20 O-Ring 40 OD, PTFE 019 752 1 40 Valve Plate, FFPM 068 903 2 50 Diaphragm, PTFE 068 595 1 10 O-Ring 15 OD, EPDM 008 112 1 --- Spares Kit, Polypropylene 068 691 1 1. This list contains the number of parts required per pump head. 2. The listed parts can also be ordered separately. -- 6 --