SOUND TRANSMISSION PROPERTIES



Similar documents
Lightweight Partition Design for Residential and Commercial Buildings

EVERYTHING YOU WANTED TO KNOW ABOUT SOUND BUT WERE AFRAID TO HEAR.

Controlling the Transmission of Impact Sound through Floors

The Role of Acoustics in Curtain Wall Design:

Mass Loaded Vinyl A review of the performance and cost in acoustical applications

How does Architecture Affect the Acoustics of a Space

The Acoustical Properties of Wool Carpet

Acoustical Doorway Solutions

In today s architectural environment, good acoustical design isn t a luxury

Color logos Reverse logos Acoustics Black only logos

ENGINEERING DATA. Fan Sound & Sound Ratings

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

ROOM ACOUSTICS DESIGN. Room Acoustics Design Intent: Appropriate Articulation

ACOUSTIC DESIGN - ROOMS FOR SPEECH

Acoustical Design Guidelines for HVAC Systems in Schools

VIPAC ENGINEERS & SCIENTISTS

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications

GENERAL PROVISIONS

PART 1 GENERAL 1.1 SECTION INCLUDES

Cost Comparisons for Common Commercial Wall Systems

Acoustic Terms, Definitions and General Information

Fundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer

DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS

VERTICAL DESIGN OPTImAL ACOUSTICS

R-Value and Densities Chart

Product Information. Tel: x2426 or x2443 Fax:

Fire and Concrete Structures

Certification: Building Plans Examiner. Exam ID: B3

Retrofit structural insulated panels (SIPs) increase sound transmission loss of existing single family houses impacted by highway noise

LAYING BLOCK AND BRICK

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

CH. 2 LOADS ON BUILDINGS

Underwriters Laboratories Testing Information

Annex of the certificate (Page 1/6) Accreditation Scope

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

How To Reduce Noise From A Test Screen

Materials and Colors

Specifications, Product Testing and Terminology

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

The Case for Cross Laminated Timber: Part 2

ST. MONICA FOOD PANTRY HOUSTON, TEXAS

Triarch Products Over Various Interior Substrates

SECTION ACOUSTICAL WALL TREATMENT. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

How to Estimate the Cost of Interior Building Finishes from Schematic Drawings. CPE Candidate No December 2014

Gypsum Board Systems Manual

COMMONLY USED RESIDENTIAL BUILDING CODES

TAX APPRAISAL DISTRICT OF BELL COUNTY STORES & COMMERCIAL IMPROVEMENT CLASSIFICATION GUIDE

Introduction...COMB-2 Design Considerations and Examples...COMB-3

MRI RF SHIELDING DESIGN

Office acoustics. How to effectively design the room acoustics of offices. AN INFORMATION BROCHURE OF

Excerpts from the Canadian National Building Code (NBC)

Acoustic expectations, health effects, and design techniques in the urban environment

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

ASTM E 90: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

Acoustical Design for Concert Hall in the Science and Art Centre of Xiamen University

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

GRADATION OF AGGREGATE FOR CONCRETE BLOCK

Built to Last. Built for Beauty. Good. Solid. Logix. TM

ACOUSTICS: The Sounds of Sustainable Design

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Heating Load Calculation

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Repair and Remodeling Estimating Methods. 4th Edition. RSMeans

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

Nominal Life Expectancy for Building Components

TOP 10 NOISE CONTROL TECHNIQUES

INTER-NOISE DECEMBER 2006 HONOLULU, HAWAII, USA

Noise Control Solutions For Standby Power Generators

The Effects of Ultrasonic Sound Generated by Ultrasonic Cleaning Systems on Human Hearing and Physiology

Bafl-Sorb Sound Absorbing Ceiling Baffles

Insulation R-Value Comparisons

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

Asbestos in the home. for you - for your community - not for profit

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: TREX COMPANY, LLC. Series/Model: Trex Seclusion

Asbestos Information

ProRox Slabs (formerly known as RW slabs)

SPEECH INTELLIGIBILITY and Fire Alarm Voice Communication Systems

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

Relationship between Sound Pressure and Sound Power Levels

HVAC Calculations and Duct Sizing

Building Design for Advanced Technology Instruments Sensitive to Acoustical Noise

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MGM INDUSTRIES SERIES/MODEL: TYPE: Single Hung Window


Noise Control. Commercial, Industrial, and Environmental Products and Solutions.

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

CHAPTER 6 CONSTRUCTION TYPES

CONTRACT PRICE ADJUSTMENT PROVISIONS (CPAP)

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

48. AQUARIUM. Aquarium. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle. Total Area: No.

Rockwool Flexi Insulation Application Guide

Airborne asbestos is a serious health hazard.

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: VL-WDW11 VistaLuxe Awning

Transcription:

SOUND TRANSMISSION PROPERTIES LIGHTWEIGHT CONCRETE INFORMATION SHEET No. 8 EXPANDED SHALE CLAY AND SLATE INSTITUTE - SALT LAKE CITY, UTAH 84117 SOUND TRANSMISSION PROPERTIES The control of sound in rooms of buildings may be classified with respect to the origin of the soundnamely: sounds originating within the room and sounds originating outside the room. Efficient and economical control of sound is dependent not only upon its origin, but also upon the design of the enclosure and type of occupancy. For reduction of sound originating within a room, the sound absorption qualities of the walls, ceiling and flooring as well as furnishings are important. The type and use of the room affords the architect latitude in the selection of sound absorption materials for elements of the room, see Information Sheet #9. Enclosures with high ceilings and large expanse of wall areas, as in gymnasiums and churches, might utilize sound absorbing textured masonry walls as an economical solution. On the other hand, for enclosures with relatively low ceilings. and rather small exposed wall areas, as in offices and schoolrooms, the use of acoustical ceilings, floor coverings, and interior furnishings might be the more effective solution. This information sheet is concerned primarily with the reduction of sound through concrete and concrete masonry partitions from sources outside of rooms. These sounds are transmitted as solid borne, as well as air-borne noise. For example, a bare concrete floor transmits the sound of footsteps between rooms, the sound traveling through the rigid concrete slab. Solid-borne sound should be suppressed at the source. A concrete floor for example. should be covered with some type of resilient material. depending upon the extent of solid-borne sound transmission which should be suppressed. Air-borne sound may be effectively reduced by barriers such as concrete masonry partitions. Obviously. attention should be given to doors and their closures. as well as connections of the walls at the ceilings and floors. Too often the effectiveness of a concrete masonry partition which should provide satisfactory acoustical isolation is unnecessarily lost. This may occur by failure to take into account the other important factors that are involved. such as continuing the partition to the structural ceiling. Also, cutting of continuous holes through the wall for ducts, electrical outlets, should be avoided. SOUND ENERGY Sound energy is measured in decibels. The decibel is a convenient unit because it is approximately the smallest change in energy that the ear can detect. The following table of sound intensities will aid in an understanding of decibel values.table I ------------------------------------------------------------------------

TRANSMISSION Sound is transmitted through most walls and floors by setting the entire structure into vibration. This vibration generates new sound waves of reduced intensity on the other side. The passage of sound into one room of a building from a source located in another room or outside the building is termed ''sound transmission" TRANSMISSION LOSS Transmission loss is a measure of the effectiveness of a wall, floor, door or other barrier in restricting the passage of sound. The transmission loss varies with frequency, and the loss is usually greater with higher frequencies. Sound transmission loss measurements are conducted in accordance with American Society for Testing and Materials (ASTM) designation E-90. A concrete or concrete masonry wall eleven (11) feet (3.35 m) wide and nine (9) feet (2.74 m) high mounted on a movable base is rolled between two isolated reverberation rooms. Measurements are made at 16 frequencies in 1/3 octave bands from 125 to 4000 cycles per second (cps) (generally called Hertz. Hz). The unit of measure of sound transmission loss is the decibel (db). The higher the transmission loss of a wall the better it functions as a barrier to the passage of unwanted noise. Table 1 Sound Levels and Human Response This decibel (db) table compares some common sounds and shows how they rank in potential harm to hearing. COMMON SOUNDS NOISE LEVELS (db) EFFECT Jet engine (near) 140 Shotgun firing Jet takeoff (100-130 Threshold of pain 200 ft.) Thunderclap (near) Discotheque 120 Threshold of sensation Power saw Pneumatic drill Rock music band 110 Garbage truck 100 Subway Motorcycle Lawnmower Electric razor Many industrial workplaces Average city traffic noise Garbage disposal Vacuum cleaner Hair dryer Inside a car Normal Conversation Quiet office Air conditioner Regular exposure of more than 1 min. risks permanent hearing loss No more than 15 min. unprotected exposure recommended. 90 Very annoying 85 Level at which hearing damage begins (8 hours) 80 Annoying. Interferes with conversation 70 60 Intrusive. Interferes with telephone conversation 50 Comfortable Whisper 30 Very quiet Normal breathing 10 Just audible Threshold of normal hearing (1000-4000 0 Hertz)

SOUND TRANSMISSION CLASS (STC) Sound Transmission Class (STC) is a single number rating determined in a prescribed manner from sound transmission loss values, This rating is arrived at by comparing the measured transmission losses at the 16 test bands with those of a reference contour having the form illustrated in Figure 1. The sum of the deficiencies below the contour shall not be greater than 32 decibels (db) and the maximum deficiency at a single test point shall not exceed 8 decibels (db). When the contour is at the highest value that meets the above requirements, the Sound Transmission Class for the specimen is the transmission loss (TL) corresponding to the intersection of the counter and the 500 Hz ordinate. Sound Transmission Class ratings are established in accordance with ASTM designation E-413, ''Standard Classification for Determination of Sound Transmission Class.' ' This rating provides an estimate of the performance of a partition in sound insulation. The STC Figure 1 numbers are used to specify the minimum noise insulation needed in a building. For example, the minimum STC values acceptable for Multi-family housing by the Department of Housing and Urban Development (HUD) are shown in Table 2 below. TABLE 2 Notes: HUD SOUND TRANSMISSION REQUIREMENTS FOR WALLS IN MULTIFAMILY HOUSING LOCATION OF PARTITION STC Living unit to living unit, corridor(1) or public space, average noise(2) 45 Living unit to public space and service areas, high noise(3)(4) 50 1. These values assume floors in corridor are carpeted: otherwise increase STC by 5. 2. Public space of average noise includes lobbies, storage rooms, stairways, etc. 3. Areas of nigh noise include boiler rooms, mechanical equipment rooms, elevator shafts, laundries, incinerator shafts, garages, and most commercial uses. 4. Increase STC by 5 when over or under mechanical equipment which operates at high noise levels. Many walls constructed with lightweight concrete masonry units produced with expanded shale, clay or slate by the rotary kiln method have been tested. Tests of these various walls are listed in Table 3. The results shown in this table indicate that concrete and concrete masonry produced with expanded shale clay and slate aggregates meet existing standards.

TABLE 3 SOUND TRANSMISSION CLASS (STC) for LIGHTWEIGHT CONCRETE MASONRY WALLS MASONRY WALL THICKNESS 4 inch 6 inch 8 inch 12 inch Plain 40 44 45 Painted 41 45 46 50 Wall Board 47 49 56 Plastered 50 50 51 Cores Filled with insulation 51 COMPOSITES* Cavity* Grouted 8" 4" Block plus 4" Concrete Brick plain 51 1/2" plastered on block surface 53 1/2" gyp. on block face 56 10" CAVITY 4" Block 2" Cavity 4&#quot; Concrete Brick plain 54 1/2" plastered on Block 57 1/2" gyp. on block 59 8" GROUTED BLOCK All cells grouted 48 1/2" plaster both sides 56 1/2" gyp. both sides 60 IMPACT SOUND The increased noisiness of our environment has led to increased interest in sound isolation from impact noise. Impact noise is caused by such things as footsteps, dropped toys and some appliances. Isolation against impact noise provided by a given floor construction is measured in accordance with ASTM E492 "Laboratory Measurement of Impact Sound Transmission Through Floor- Ceiling Assemblies Using The Tapping Machine." This procedure utilizes a standard tapping machine that is placed in operation on a test floor specimen which forms a horizontal separation between two rooms, one directly above the other. The transmitted impact sound is measured in 1/3 octave bands over a frequency range of 100 to 3150 Hz in the receiving room below. From the data collected a single figure rating, called Impact Insulation Class (IIC) is derived in a prescribed manner from the values of the impact sound pressure levels measured in the receiving room. The rating provides an estimate of the impact sound insulating performance of a floorceiling assembly. Details of the procedures are outlined in ASTM E492. The Expanded Shale Clay & Slate Institute sponsored a test program at Riverbank Laboratories,

Geneva, Illinois, to determine the effect of the concrete weight and Modulus of Elasticity on impact sound transmission. Slab thicknesses of 5 inches and 10 inches were selected for study. Three concretes designed to weight approximately 95. 115, and 150 pounds per cubic foot were used, so the weight per square foot of floor would cover a broad range. The slabs were designed for 3000 psi (210 Kgsg. cm.) concrete and included reinforcement in keeping with flat plate design. The Impact Noise Reduction (INR) factors determined from the Riverbank Laboratory tests have been converted to the current designation, Impact Insulation Class (IIC). and are shown in Table #4. Comparison of the test data with the current HUD requirements indicated that concrete floors of any weight require additional surface treatment to bring the IIC rating to acceptable levels. (see Table 5) TABLE #4 Impact Insulation Class (IIC) Slab Thickness 5 inch 10 inch Slab Wt Ibs/cu.ft. 95 115 150 95 115 150 IIC Bare Floor 23 24 24 23 30 31 IIC Std. Carpet 68 74 IIC Vinyl Tile 33 Estimated from NRC (National Research Council) report 1/8 inch Vinyl asbestos on 1/2 inch plywood on furring 48 48 52 53 Viscose Carpet with 1/8 inch loop pile, coated back 57 58 62 64 Impact Insulation Class (IIC) values that are acceptable for multifamily housing under HUD are listed in Table #5 below. TABLE #5 HUD Sound Transmission Limitations for Floors in Multi Family Housing LOCATION OF FLOOR CEILING STC IIC Floor-ceiling separating living units from other living units, public space (1) or service areas (2) 45 45 Floor-ceiling separating living units from public space and service areas (high noise) (3) including corridor floors over living units 50 50 Note: (1) Does not apply to door above storage rooms where noise from living units would not be objectionable. (2) Public space of average noise includes lobbies, storage rooms, stairways, etc. (3) Areas or high noise include boiler rooms, mechanical equipment rooms, elevator shafts, laundries, incinerator shafts, garages and most commercial uses. CONCLUSION Expanded Shale Clay & Slate aggregate concrete and concrete masonry meets the commonly accepted specification for air borne noise reduction. This quality combined with its demonstrated durability, fire resistance, thermal insulation properties and aesthetics quality make it an extremely desirable and practical building material.

REFERENCES Expanded Shale Clay & Slate Institute. 1. Lightweight Concrete Information Sheet No. 9. "Sound Absorption of Concrete Masonry Walls." National Concrete Masonry Association. 1. TEK Sheet #9. "Estimating Sound Transmission Class of Concrete Masonry." 2. TEK Sheet $#18. "Noise Control with Concrete Masonry in MultiFamily Housing." 3. TEK Sheet #69. "Noise Insulation with Concrete Masonry." 4. TEK Sheet #69.A, "New Data on Sound Reduction with Concrete Masonry Walls.'' Building Materials and Structures Report 144. National Bureau of Standards. ''Insulating Concretes". by R.C. Valore, Jr.. ACI Journal November. 1956. ''Impact Sound Transmission Tests On A Concrete Slab Floor with Various Surface Constructions" by D. Olynyk. Division of Building Research. National Research Council. Ottawa. Canada. July. 1967. EXPANDED SHALE CLAY AND SLATE INSTITUTE SALT LAKE CITY, UTAH 84117 COPYRIGHT, 1966, EXPANDED SHALE, CLAY AND SLATE INSTITUTE Sound Absorption Three terms are introduced to define and evaluate sound absorption. These are the Sound Absorption Coefficient, Sabin, and Noise Reduction Coefficient. The Sound Absorption Coefficient is a measure of the proportion of the sound striking a surface which is absorbed by that surface, and is usually given for a particular frequency. Thus, a surface which would absorb 100% of the incident sound would have a Sound Absorption Coefficient of 1.00, while a surface which absorbs 45% of the sound, and reflects 55% of it, would have a Sound Absorption Coefficient of 0.45. A Sabin or squarefoot Unit of Absorption is defined as the amount of sound absorbed by one square foot of surface having a Sound Absorption Coefficient of 1.00. The number of Sabins (Absorption Units) of a given area is then the product of the area and the Sound Absorption Coefficient. 100 sq. ft. of a surface with a Sound Absorption Coefficient of 0.25 furnishes 25 Sabins (Absorption Units). Most materials are tested at frequencies from 125 to 4000 cycles per second (cps) in octave steps. The Noise Reduction Coefficient is the average of the Sound Absorption Coefficient at 250,000, 1000 and 2000 cps in octave steps. The Table lists approximate values of the Noise Reduction Coefficients of numerous materials.

Noise Reduction Coefficients Material Approx. N.R.C. Expanded Shale Block, 0.45 Add 10% for Coarse Texture, Medium Texture, unpainted Deduct 10% for Fine Texture Heavy Aggregate Block, Medium Texture, unpainted 0.27 Add 5% for Coarse Texture, Deduct 5% for Fine Texture DEDUCTIONS FROM ABOVE FOR PAINTED BLOCK PAINT TYPE APPLICATION ONE COAT TWO COATS THREE COATS Any Spray 10% 20% 70% Oil Base Brushed 20 55 75 Latex or Resin Base Brushed 30 55 90 Cement Base Brushed 60 90 Material N.R.C. Brick Wall unpainted.05 painted.02 Floors Concrete or terrazzo.02 Wood.03 Linoleum, asphalt, rubber or cork tile on concrete.03 -.08 Glass.02 Marble or glazed tile.01 Plaster, gypsum or lime, smooth finish on tile or brick.04 Same, on lath.04 Plaster, gypsum or lime, rough finish on lath.05 Plaster, acoustical.21 Wood paneling.06 Acoustical ceiling tile.55 -.85 Carpet, heavy, on concrete.45 Carpet, heavy, hairfelt underlay.70 Fabrics Light, 10 oz. per sq. yd. hung straight.20 Medium, 14 oz. per sq. yd. draped to half area.57 Heavy, 18 oz. per sq. yd. draped to half area.63 Audience, seated, depending on character of seats, spacing, etc 3.0-6.0 Chairs, metal or wood.20 Wood pews.40 Same with cushions 2.00 Theatre and auditorium chairs Wood veneer seat and back.50 Upholstered in leatherette 2.10 Heavily upholstered in plush or mohair 3.0-3.5 Openings Stage, depending on furnishings.25-.75 Deep balcony, upholstered seats.50-1.00 Grills, ventilating.15-.50

Sound Transmission The architect in considering the reduction of sound through walls separating rooms of schools, hotels, or office buildings for example, is concerned with reducing a sound intensity of say, 55 decibels to something on the order of 15 decibels or less. He is able to select these values by referring to the Table. Referring to the chart and the curve representing an expanded shale masonry unit with an 8" x 16" face, it is found that a unit weighing 95 Ibs. air dried, will offer a transmission loss of approximately 42 decibels (if properly sealed). The average 4-8-16 expanded shale masonry unit weighs approximately 15 Ibs. air dried, therefore a partition wall made of these units can be expected to reduce the sound transmission satisfactorily for the assumed situation, provided of course, the surfaces of the wall are sealed sufficiently to prevent the direct passage of sound through the voids. Masonry vs. Steel Stud Because the sound-diminishing qualities of concrete masonry 'keep the noise outside', structures utilizing the masonry backup system enjoy a quieter internal environment. In contrast, the dry wall component of the steel stud system frequently contains acoustical holes. This negative factor is substantially magnified when we consider the fact that the steel stud system, itself, is inherently noisy. The mass and monolithic properties of concrete masonry make the system far superior in its ability to reduce sound transmission.