profile PC vs. PLC: key factors in comparing control options Drive & Control PC or PLC: Key Factors



Similar documents
PC & EMBEDDED CONTROL TRENDS

Linear Motion and Assembly Technologies Pneumatics Service. Industrial Ethernet: The key advantages of SERCOS III

Software INTERACT. MachineLogic. The Shortest Distance Between Man and Machine

Integrated Application and Data Protection. NEC ExpressCluster White Paper

The Future of CAN / CANopen and the Industrial Ethernet Challenge by Wilfried Voss, President esd electronics, Inc USA

HMI & Virtualization in Process Automation

Physical Infrastructure for a Resilient Converged Plantwide Ethernet Architecture

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

1.1.1 Introduction to Cloud Computing

Windows Server 2003 migration: Your three-phase action plan to reach the finish line

Physical Infrastructure Management Solutions

The integrated HMI-PLC

PROFIBUS/PROFINET System design

Real-time Video Monitoring Increases the Efficiency of SCADA Process Management

The Advantages of Plant-wide Historians vs. Relational Databases

GETTING STARTED WITH ANDROID DEVELOPMENT FOR EMBEDDED SYSTEMS

Microsoft Private Cloud Fast Track Reference Architecture

The Advantages of Enterprise Historians vs. Relational Databases

Microsoft s Open CloudServer

Understanding Device Level Connection Topologies

Real-time processing the basis for PC Control

EVALUATING INDUSTRIAL ETHERNET

Windows Embedded Security and Surveillance Solutions

Virtualization In Manufacturing Industries. Copyright 2012 Rockwell Automation, Inc. All rights reserved.

Linear Motion and Assembly Technologies Pneumatics Service. Understanding the IEC Programming Languages

Automation & Control Planning Guide

Cisco IronPort Security Appliances

Chapter 3: Operating-System Structures. System Components Operating System Services System Calls System Programs System Structure Virtual Machines

SNAP-SCM-PROFI Communication Module

SPPA-T3000 Control System The Benchmark in Controls

Security in the smart grid

TEST MANAGEMENT SOLUTION Buyer s Guide WHITEPAPER. Real-Time Test Management

Operating system Dr. Shroouq J.

Samsung SDS. Enterprise Mobility Management

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

DIGITAL CONTROL SYSTEM PRODUCT SOLUTIONS

Migrating Control System Servers to Virtual Machines

Difference between Enterprise SATA HDDs and Desktop HDDs. Difference between Enterprise Class HDD & Desktop HDD

Ethernet/IP Explicit Messaging Using Unity Software

19 Comparison of Ethernet Systems

IronPort C10 for Small and Medium Businesses

Automation Motion Server


Traditionally, a typical SAN topology uses fibre channel switch wiring while a typical NAS topology uses TCP/IP protocol over common networking

QUICK REFERENCE GUIDE MOBILE HUMAN MACHINE INTERFACE (HMI): INNOVATION THAT EMPOWERS THE MOBILE OPERATOR

Axis IP surveillance. Endless possibilities for video surveillance.

2015 HSC Information and Digital Technology Networking and hardware Marking Guidelines

VBLOCK SOLUTION FOR SAP APPLICATION SERVER ELASTICITY

Hi and welcome to the Microsoft Virtual Academy and

Straton and Zenon for Advantech ADAM Copalp integrates the straton runtime into the ADAM-5550 device from Advantech

Taking the Open Path to Hybrid Cloud with Dell Networking and Private Cloud Solutions

Modernize your Monitor Pro software with less risk, less cost and less effort

A White Paper By: Dr. Gaurav Banga SVP, Engineering & CTO, Phoenix Technologies. Bridging BIOS to UEFI

Smart Thermostat page 1

Unifying IT How Dell Is Using BMC

THE RTOS AS THE ENGINE POWERING THE INTERNET OF THINGS

ITIL Intermediate Capability Stream:

Intrusion Detection and Cyber Security Monitoring of SCADA and DCS Networks

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution

A descriptive definition of valve actuators

IBM System Storage SAN Volume Controller

Square D Model 6 Motor Control Centers

BEST PRACTICES RESEARCH INSERT COMPANY LOGO HERE

Information Security Services

Chapter 2: OS Overview

E-Series. Human Machine Interfaces. Evolution By Design MITSUBISHI ELECTRIC AUTOMATION, INC.

HIPAA Compliant Infrastructure Services. Real Security Outcomes. Delivered.

Smart Data Center Solutions

Upgrade to Microsoft Windows Server 2012 R2 on Dell PowerEdge Servers Abstract

The Case for Intelligent Remote I/O. The Case for Intelligent Remote I/O. Wise Delegation for Your Automation System. Introduction

WHITE PAPER. VMware Infrastructure 3 Pricing, Packaging and Licensing Overview

Remote Maintenance with Security Appliances FL MGuard RS2000 and RS4000. Economic and Reliable Service

Mac computer configurations & OS X optimizations (Updated: November 2012)

EMC Virtual Infrastructure for Microsoft SQL Server

Nine Cyber Security Trends for 2016

Virtualizing SQL Server 2008 Using EMC VNX Series and Microsoft Windows Server 2008 R2 Hyper-V. Reference Architecture

SCADA System Fundamentals

SAM Benefits Overview SAM SOFTWARE ASSET MANAGEMENT

Supporting the Alert Standards Format (ASF) 2.0 Specification

G4 Digital DC Output Modules. G4 Digital DC Output Modules. Features. Description. Part Numbers

Transmission and distribution service level agreements

Servo drives. Compact converter IndraDrive Cs

A M D DA S 1. 0 For the Manageability, Virtualization and Security of Embedded Solutions

Field Products. Experion LX. Proven, Easy to Use and Purpose-built Distributed Control System

Data Warehouse Appliances: The Next Wave of IT Delivery. Private Cloud (Revocable Access and Support) Applications Appliance. (License/Maintenance)

Microsoft IT Increases Security and Streamlines Antimalware Management by Using Microsoft Forefront Endpoint. Protection 2010.

integrated lights-out in the ProLiant BL p-class system

Security solutions White paper. Acquire a global view of your organization s security state: the importance of security assessments.

Industrial Personal Computer. 2 rue René Laennec Taissy France Fax: , Tel :

A guide to CLARiSUITE TM network solutions

FOR IMMEDIATE RELEASE

Transcription:

profile Drive & Control vs. : key factors in comparing control options or : Key Factors Complex mechatronic systems require careful advance planning to ensure optimum performance and the best total cost of ownership. When deciding whether to choose a or, analyze and compare characteristics that could differentiate the two technologies such as operation, robustness, serviceability, hardware integration, security, safety, programming and cost. One of the most crucial decisions in the initial design phase of a machine is the selection of the control system. For years the has been leading the way for advances in machine automation control. From small controls used in the automotive industry to large-scale controllers running entire factories, the was the primary controller of choice. Since s were first introduced in the 1970s through today, they have dominated the process and automation markets. Operation: Focus on how system will run and how tasks/ instructions are processed Robustness: Some s have moving parts (disk drives) choose controls able to withstand high vibration environments Serviceability: Consider availability of replacement components and ease of repair/ replacement over controller life Hardware: Assess application and communication requirements, fieldbus interfaces (SERCOS etc.), memory and processor capacity, and HMI integration Security: s have not been virus targets in the past; however hackers constantly seek new paths into industrial/corporate networks Safety: Integrated safety features are well-established on s, only recently available on -based platforms Programming: Both programming environment (how control executes program) and language (IEC 61131 for s, proprietary, C++) affect machine development time and operation Cost: Consider cost issues such as motion/logic performance, machine expandability, operating environment and total cost of development to final delivery

However, from the early 90s to present day, the has been successfully working its way into those markets as processor speed and range continue to increase and the cost of those components continues to decrease. The number of applications utilizing a is on the rise, causing an accelerated development that blurs the line between the two technologies. Ten years ago it might have been a clear choice what type of controller to use; today that is no longer the case. The was developed as a more streamlined, flexible and reliable alternative to switch boxes and relay panels. It was designed to be dedicated only to specific tasks in the factory and its language and structure were modeled around the switches and relay panel circuits it was replacing. Furthermore, it had to maintain its robustness and consistent performance in challenging environments that contained relatively high levels of EMI, contamination, and vibration. As time passed, the evolved to include the capabilities of motion control, advanced PID process control and integrated safety, while also adopting some features such as a web server and networking utilities. The on the other hand, served a higher level role in the scope of the machine. It was used primarily for complex calculations, monitoring, measuring and factory networking as well as a user-interface to the. It was usually housed in a more environmentally controlled location because it couldn t operate as reliably as a in harsh factory conditions. The eventually evolved to include functionality while still containing its core capabilities. Also, the has become a more robust controller, allowing it to operate in the harsh environments that were once only possible for operation. In analyzing their control architectures we can see even more convergence of the technologies. With the addition of a I card, hardware drivers and software you can turn your into what is known as a soft-. Furthermore you can add a real-time kernel to support more critical tasking and control algorithms. On the other hand, there are s with a built-in where all you need is a keyboard and mouse to get started. So, how do you choose one type of control over another? In trying to figure out whether to choose a or, it is important to first try to simplify the decision-making process by analyzing and comparing some of the characteristics that could differentiate the two technologies. For this discussion, there are seven major areas to consider for comparison: Operation Robustness Serviceability Hardware Integration Security Safety Programming Operation When analyzing system operation, the focus should be on how the system will run and how instructions and tasks are processed. The standard has an embedded real-time operating system (RTOS) with a dedicated processor that ensures a high degree of control system reliability. Furthermore, since the task of the is only to handle automation and/or a process, it does not need to run other utilities such as antivirus programs or system updates. The has become a more robust controller allowing it to operate in the harsh environments that were once only possible for operation. In turn, the with the introduction of a real-time kernel or real-time OS can accomplish the same reliability

of control as a. From their experience with s at home and in the office, users might be wary of lock-ups of the (the so-called blue screens ). It is important to note that these lock-ups could occur on any OS including a if the software running it is not handling priorities properly. For industrial use, the software running the is dedicated to automation and will therefore have a minimal chance of lock-ups. Even if a lock-up would occur, the real-time kernel is not affected and continues operation. Real-time operation is a relative concept that means any task is guaranteed to be handled within a certain time. Synchronized motion and/or advanced PID control requires a high level of real-time determinism while non-critical supervisory controller operations such as monitoring error messages or sending non-critical controller commands or queries would not. Robustness Robustness of the controller essentially refers to its durability in various environments. The standard off-the-shelf has no moving parts so it can withstand harsh environments for millions of cycles. A standard contains some moving parts such as fans or hard disk drives, and is therefore less suited for environments with high vibration levels. However, industrial s offer options such as solid state drives, fanless cooling and in-cabinet mounting. With these options, a becomes just as durable as a and can successfully withstand the toughest industrial or environmental conditions. Both the and have converged in this area but the requires additional options to equal a standard. Serviceability Another factor to consider is the ease and cost of serviceability, i.e. the repair and replacement costs over the life of the controller. For a, external devices can be replaced with ease while the system is in operation. Moreover, if you must replace the actual controller, the s compact modular design makes that a quick and painless job. This saves cost because it significantly reduces the down-time of the machine. In a you can also hot swap, but only USB or other external peripheral devices. If the has a more modular design, such as with a rack or panel-mount system, replacement time becomes closer to that of the. Not only is it beneficial to be able to effortlessly change out a system or its components, but to also have a constant resource pool of replacement parts with long-term availability. In some industries copy exact policies require this long-term availability. It is easier to implement copy exact with a since it doesn t change as rapidly as a in terms of hardware and firmware. Trying to find parts for a even after a year or two is far more challenging than with a. You can copy exact both, but it proves to be more difficult to do this for a. Hardware Every engineer appreciates a wide choice of options when selecting the control system hardware, as there is always a need for items such as additional peripherals, memory and a user interface. Both the and have the ability to control a multitude of devices using industrial communication networks. Some of the well-known networks used are SERCOS, Profibus, DeviceNet and CANbus as well as their more modern Ethernet-based counterparts such as SERCOS III, Profinet, Ethernet/IP and EtherCAT. Although the and can both offer an array of fieldbus options, the has many of these options built in where the would need additional cards and drivers to provide a comparable offering. However, besides the typical fieldbus networks the is equipped with a more open and flexible array of interfaces such as USB, FireWire, Serial, wireless Ethernet, etc. This gives the user access to more off-the-shelf devices to handle tasks that a could not usually handle. An example is the utilization of an advanced hi-res imaging system where the images would be stored, analyzed, compared and possibly archived. For this, a would be better suited because of the advanced nature of this task and the amount of memory required, while a would have limited storage and processing capabilities. For some applications, the user interface is a crucial component on the machine. The has one built in while the would need one or all of the following for primary operation: switches, operator panel(s), or an industrial. So while the can interface with devices over fieldbus and can do complex operations, it still needs the to handle more memory demanding tasks and to sometimes make connections to other devices in

the system that a would have no direct connection to. Security Security mainly deals with protecting the file system and application. This has two aspects: preventing unauthorized access from the outside world (e.g. virus attacks, malware, etc.) and limiting user access (e.g. restricting user rights, hiding files, etc.). Traditionally, a is less exposed to unauthorized access from the outside world. In addition, because of its dedicated OS, very few instances are known of virus attacks on s. Note that this does not mean that s are immune to viruses! Moreover, since s have enjoyed a virus-free status for years, there are no standard ways of detecting and eliminating a virus if it would occur. Although the is far more susceptible to virus attacks than a, strict security measures can be invoked to significantly reduce potential threats, and standard software is available to detect and remove viruses. communication channels to slave devices to tightly monitor operation, and optionally has additional integrated circuits to allow for redundancies. Integrated safety has only recently become available on some -based platforms, and does not have a wide acceptance base yet. Programming The functionality of a device is only as good as the program running on it. Therefore the programming environment and language are crucial to optimal machine performance. One main difference between - and -based solutions is how the code is executed. A has a mixture of scan-based and event-driven program execution, whereas software typically operates as event-driven. The scan-based execution of a program might take longer because the system needs to complete the higher priority actions in the cycle first. The difference in execution style requires a different programming philosophy, and often users are committed to either one or the other. The same holds for the programming language: s are programmed using either one of the languages specified in IEC61131-3 (ladder logic, instruction list, etc.) or some proprietary vendor language, whereas -based controls can use programming languages such as C/C++/.NET. These languages offer unparalleled flexibility and easy integration. One last item: the cost discussion Even after analyzing the technical requirements and comparing the design options for your machine, there is one more topic that needs to be considered: cost. Many applications can be solved by either a -based or -based solution, but for some applications the cost of those solutions might be quite different. A comparison of the Both the and offer different levels of user access to keep the contents as secure or as open as desired. Cost Safety Depending on the operating environment, safety can be a major concern for the user. It is vital in cases where human interaction with the machine could be potentially dangerous, and when safety standards in a fab or factory are crucial to machine acceptance. Basic operation, standalone Performance Processor speed, complex network management The with its long history in machine automation has designated Figure 1

relative cost of - and -based architectures centers on four different areas: performance, expandability, environment, and development effort. Performance vs. cost When your application requires the control system to fulfill demanding calculations, handle complex network loads and process a lot of data, look closely at the cost of a -based solution. Although the initial cost of a might be higher, it provides a very powerful system of which the cost only increases incrementally when more performance is required. s, however, typically start at a lower price point, but can quickly get more expensive than a when high performance is needed (Fig. 1). Figure 2 Cost t No additional functions CCC Expandability Data logging, peripherals, analysis Expandability vs. cost A similar scenario holds when considering expandability, for example the capability of your control system to add peripherals, increase calculation power or add data storage. s tend to have a higher cost when no additional functions are needed (because of the optimized nature of a ), but cost does not increase much when increasing expandability. The cost of a is typically lower for applications where these items are not important, but the cost ramps up steeply when a lot of additional devices are needed (Fig 2). Operating environment vs. cost The operating environment can sometimes be the deciding factor for the type of control system, if solely based on cost. The standard was designed to withstand the sometimes harsh conditions found in an industrial factory setting. It is no surprise that the standard costs much less to operate in rough environments High cost, non-standard Figure 3 Cost t Low cost, standard Cleanroom in comparison to the. Adding components to make a more robust significantly increases the cost (Fig. 3). Environment Vibration, dust, fluids Development time and application level vs. cost Software development time can add a significant cost to a machine design

project, but it often remains hidden when initially selecting the control system. If this is the first time the particular control system is applied, do you take the time to learn the new product or do you hire a third party with knowledge of the product to help integrate the new system? Development Time With a that utilizes a common format such as IEC61131-3, chances are that even if you are not familiar with the language, there is a large resource pool of those who are. Moreover, this platform has several built-in functions that are ready to integrate and solve certain problems quickly. Therefore the can sometimes be a less expensive option than a -based controller from a development standpoint, for those who are first-time or intermediate users: the development time (or cost) decreases as the level and knowledge base of the user increases (Fig. 4). With extensive expertise and intimate knowledge of the system, there will be Application Level Figure 4 little or no difference between a issues to consider are performance, and -based solution. functionality and cost. However, looking deeper and considering Conclusion factors such as programming needs, The bottom line is that you will most security and other criteria will ensure likely choose either a or or a smooth system integration process both for your control system. The main in the long run. www.facebook.com/boschrexrothus twitter.com/boschrexrothus www.youtube.com/boschrexrothus 2011 Bosch Rexroth Corporation Subject to change without notice. Printed in USA. ALL RIGHTS RESERVED FORM vs (0511) Bosch Rexroth Corporation 5150 Prairie Stone Parkway, Hoffman Estates, IL USA 60192-3707 Telephone (847) 645-3600 www.boschrexroth-us.com