CARESCAPE V100 Vital signs monitor



Similar documents
GE Healthcare. CARESCAPE V100 Vital Signs Monitor

GE Healthcare. B40 Patient Monitor Connecting intelligence and care.

Datex-Ohmeda Critical Care Monitor

PROCARE Monitor B20. Balanced performance and investment CHINA SFDA PENDING

GE Healthcare CARESCAPE V100. Vital Signs Monitor

CARESCAPE V100 Vital Signs Monitor

More than monitoring. Uniting.

ACCESSORIES LIFEPAK DEFIBRILLATOR/MONITOR. for use with the. Genuine accessories from Physio-Control

CARESCAPE VC150 Vital Signs Monitor. Connecting intelligence and care.

ACCESSORIES LIFEPAK 20 DEFIBRILLATOR/MONITOR SERIES. Genuine accessories from Physio-Control

Simpler on the outside. Smarter on the inside.

Respiratory Function Solutions Sensor and Sampling Line Guide. Nellcor with OxiMax Technology Product Guide A Full Line of Oximetry Sensors

ACCESSORIES LIFEPAK 12 DEFIBRILLATOR/MONITOR. Genuine accessories from Physio-Control

ACCESSORIES LIFEPAK DEFIBRILLATOR/MONITOR. for use with the. Genuine accessories from Physio-Control

GE Healthcare. Aespire Essential performance Compact design

D A cost effective monitor that meets your clinical needs VISTA 120

GE Healthcare. Lullaby Warmer. Because every baby deserves a high standard of care

Masimo anturit ja varusteet

Critical Care Therapy and Respiratory Care Section

Avalon FM20/FM30 Fetal/Maternal Monitor

D Next-generation LED phototherapy NanoBlu 500

GE Healthcare. Dash 3000, 4000 & High-acuity mobile patient monitoring

Trilogy accessory guide

Vista 120 Patient Monitor

OMNI TOUCH SCREEN PATIENT MONITOR

PRO Series V2 Pre-Service and Calibration Manual. (Models )

GE Healthcare. The Giraffe Family. Helping make sick babies well

Product Information Sheet UH36 Hi Pot Tester

Blood Pressure Accessories and Supplies

All Products of MEDIANA. All because of you,mediana will be better...

MEDIANA Corporate Profile. Contents

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

DINAMAP PRO Series V2 Monitor. Operation Manual

MAJORSINE Power Inverter

digital Vitals BY MIDMARK vitals

GE Healthcare. The new MAC * 800

CASMED 740 Vital Signs Monitor

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1

Duct Humidity Transmitter

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

SpO2 PULSE OXYMETER MD-300

Bitmos GmbH Himmelgeister Straße 37 D Düsseldorf. Tel.: +49 (0) 211 / Fax: +49 (0) 211 /

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Drayton Digistat +2RF/+3RF

GE Healthcare. Avance Carestation. Innovating with you, shaping exceptional care

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Quick Connect. quick - simple - efficient.

Redundancy Module QUINT-DIODE/40

S/5 Anesthesia Monitor. The clinician s choice

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

rigel 288 Electrical Medical Safety Analyser Key Features Applications

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Product Information Sheet UH28CS-12kV Hi Pot Tester

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

TC-9102 Series Surface Mount Temperature Controllers

SMART SENSOR COLLECTION

PRODUCT NO.: PT-P1SD PRODUCT NAME: Digital SD Slide Projector

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Welch Allyn Connex Vital Signs Monitor 6000 Series and Accessory Cable Management Stand. Advanced accessory management that stands on its own.

Networked versatility. IntelliVue MP60 and MP70 patient monitors

Operating Manual FINGERSIM SET /5.11. for SECULIFE NIBP in Combination with SECULIFE OX1

ACCESSORIES BROCHURE LIFEPAK 15 MONITOR/DEFIBRILLATOR. Genuine Accessories from Physio-Control PHYSIO-CONTROL IS A DIVISION OF MEDTRONIC

Wireless. Secure. MobileLink wireless ECG communication

DC Electronic Loads 8500 series

MLC TM Maximum Productivity and Versatility for Control without Compromise!

AC3200 INTELLIGENT BROADBAND AMPLIFIER

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Operating Manual UWAPS-TINY Series

Thyristor-controlled power supplies and battery chargers

BroadBand PowerShield. User Manual

GE Healthcare. The ECG with more knowledge built in Introducing the MAC * 5500 HD

Name: OMRON M3 HEM-7200-E Upper Arm Blood Pressure Monitor

GE Healthcare. Perfect match. Centricity Group Management and Centricity EMR

RM4TG20 three-phase network control relay RM4-T - range V

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

PIEZOMETER AIRFLOW MEASURING RING

GE Healthcare. The heart of cardiology is connectivity The MUSE * v8 Cardiology Information System

ACCESSORIES BROCHURE. LIFEPAK 20/20e. DEFIBRILLATOR/MONITOR with CodeManagement Module TM. Genuine Accessories from Physio-Control

Nikon s DigiMicro Position Encoders Nanometer Resolution with Sub-Micron Accuracy

DASH PRO VARIABLE-ACUITY MONITORING. Connecting you to the right information no matter where patient care takes you. gemedical.com

Truck: A :22 PM ton. Maximize payload, maximize profit. LOADRITE X2650 Excavator Scales. transforming the way the world works

Hygro-Thermometer + InfraRed Thermometer Model RH101

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

Waveguide Access Point WGA631. Product Guide

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

CardioSoft * Diagnostic System

3500/62 Process Variable Monitor

FIREDEX Conventional Fire Panels

DEFIBRILLATOR/MONITOR

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

SAFETY WARNINGS. Important Safety Instructions. FCC Notice. Caution

CardioCard System. Product Specification and Sample Reports. PC-Based ECG CardioCard. PC-Based Stress. PC-Based Holter. CardioCard.

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Transcription:

GE Healthcare CARESCAPE V100 Vital signs monitor In the general medical/surgical unit, you periodically check patients vital signs to monitor their status before and after treatment. A quick, reliable, easyto-use vital signs monitor is essential in helping you care for many patients with efficiency. The CARESCAPE V100 monitor can go with you from one patient to the next, enabling you to capture vital signs on all your patients using a single, mobile vital signs monitor. With speed, accuracy and connectivity, the CARESCAPE V100 monitor helps you manage Clinical Information Logistics by collecting the right information at the point of care, and presenting it wherever it is needed. So you can make fast, quality care decisions informed by relevant, current clinical intelligence.

Durable Plastic Casing Large, Bright LED Display Recessed Handle One-Step Start/Stop Button Alaris Turbo Temp (Optional) Easy to use Scrolling Menu Smart Battery Indicator Integrated Printer Battery Optional SpO2 connector GE Ohmeda, Nellcor or Masimo Intuitive Help Cards NIBP connector CARESCAPE V100 Specifications Mechanical Dimensions Height Width Depth Weight Mountings Portability Power Requirements 7.7 in (19.5 cm) 8.6 in (21.9 cm) without temperature 10.0 in (25.4 cm) with temperature 5.3 in (13.5 cm) 5.4 lb (2.4 kg) including battery Self-supporting on rubber feet or pole mounted Carried by recessed handle Power converter 2018859-001 universal P/N Monitor Protection against electrical shock DC input voltage Internally powered or Class II when powered from specified external power supply. 12 VDC, supplied from a source conforming to IEC 60601-1. Fuses: The monitor contains three fuses. The fuses are mounted within the monitor. The fuses protect the low voltage DC input, the battery, and the remote alarm output. The +5 V output on the host port connector is regulated by internal supply. Battery Environmental Refer to Battery Section Operating Temperature : + 5 C to + 40 C (+ 41 F to + 104 F) Operating Atmospheric Pressure: 700 hpa to 1060 hpa Protection against electrical shock AC input Voltage DC output Voltage Class II 100 to 250VAC, 12VA 12VDC at 1A The AC mains power adapter contains a nonresettable and nonreplaceable fuse. Storage/Transportation Storage Temperature 20 C to + 50 C ( 4 F to + 122 F) Atmospheric Pressure 500 hpa to 1060 hpa Humidity Range 5% to 95% noncondensing Radio Frequency: Complies with IEC Publication 60601-1-2 (2001). Medical Electrical Equipment, Electromagnetic Compatibility Requirements and Tests and CISPR 11 (Group 1, Class B) for radiated and conducted emissions

Alaris Turbo-Temp Specs Scale Fahrenheit (F); Celsius (C) Range Predictive mode Monitor mode Monitor mode accuracy Max: 41.1 C; 106.0 F Min: 35.6 C; 96.0 F Max: 41.1 C; 106.0 F Min: 26.7 C; 80.0 F ±0.1 C; ±0.2 F (when tested in a calibrated liquid bath; meets ASTM E1112, Table 1, in range specified) Determination time approximately 7 seconds, typical NOTE: Use only IVAC probes and P850A probe covers. The size, shape, and thermal characteristics of the probe covers can affect the performance of the instrument. Inaccurate readings or retention problems may occur unless IVAC probes and probe covers are used. Printer Spec Printer type: Thermal dot array Resolution: 384 dots/inch horizontal Paper type: The paper roll used by the printer must be compatible with GE PN 770137. Languages printed: English, German, French, Italian, Spanish, Portuguese (Brazil and Portugal), Hungarian, Polish, Czech, Finnish, Swedish, Danish, Dutch, Norwegian, and Slovak Battery Specs Capacity: 6V; 3.3 Ahr sealed lead acid battery protected by internal auto-resetting fuse and thermal protection Battery Life: 8.1 hours with a usage scenario of: NIBP determinations every 15 minutes with SpO2 and temperature active. 11.5 hours non-spo2 versions with a usage scenario of: NIBP determinations every 15 minutes with temperature active. Charge time: Approximately 5 hours from full discharge when the monitor is off. Approximately 8 hours when the monitor on. Nellcor Oxi-Max Specifications Measurement Range SpO2 1 to 100% Pulse Rate 20 to 250 bpm Perfusion Range 0.03 to 20% Accuracy Saturation Adult* Neonate* Low Perfusion** Pulse Rate Adult and neonate Low Perfusion** 70 to 100% 70 to 100% 70 to 100% 40 to 250 bpm 40 to 250 bpm *Adult specifications are shown for OxiMax MAX-A and MAX-N sensors with the N-600. Saturation accuracy will vary by sensor type. This variation equals plus or minus one standard deviation. Plus or minus one standard deviation encompasses 68% of the population. **Applicability: OxiMax MAX-A, MAX-AL, MAX-P, MAX-I, and MAX-N sensors. Oxi-Max Sensor Accuracy NOTE: All Nellcor OxiMax sensors must be used with the Nellcor cable; the DOC-10 cable. RS-10 and Oxisensor II sensors are not compatible with the V100 Vital Signs Monitor. Sensor Model SpO2 Range 70% to 100% OxiMax MAX-A, MAX-AL MAX-N* (adult) MAX-N** (neonate) MAX-P MAX-I MAX-FAST SC-A (adult) SC-PR (neonate) SC-NEO MAX-R OxiCliq OxiCliq A OxiCliq P OxiCliq N* (adult) OxiCliq N** (neonate) OxiCliq I Reusable Sensor Models D-YS* (infant to adult) D-YS** (neonate) D-YS & D-YSE D-YS & D-YSPD DS-100A OXI-A/N* (adult) OXI-A/N** (neonate) OXI-P/I Sensor Light Source Wavelength Power Dissipation ±4 digits ±4 digits Infrared: 890 nm (nominal) Red 660 nm (nominal) Infrared: 22.5mW (max) Red: 30 mw (max) * The MAX-N, D-YS, OXI-A/N, and OxiCliq N were tested on patients >40 kg. ** Neonatal Sensor Accuracy: When sensors are used on neonatal subjects as recommended, the specified accuracy range is increased by ±1 digit, as compared to adult usage, to account for the theoretical effect on oximeter measurements of fetal hemoglobin in neonatal blood. For example, MAX-N accuracy on neonates is, rather than. The accuracy specification has been determined between saturations of 80%-100%. Information about wavelength range can be especially useful to clinicians.

Factory Default Settings SpO2 HIGH Alarm Limit 100% SpO2 LOW Alarm Limit 90% Response mode 1 (for Mode 1: Normal Response) SatSeconds 0 Masimo SET Specifications Measurement Range SpO2 1 to 100% Pulse Rate 25 to 240 bpm Perfusion Range 0.02 to 20% Accuracy and Motion Tolerance Saturation Without Motion adult/pediatric * Without Motion neonate * 70 to 100% 70 to 100% With Motion adult/ped/neonate ** 70 to 100% Low Perfusion Pulse Rate Without Motion With Motion 70 to 100% 0 to 69% unspecified 25 to 240 bpm normal physiologic range 25 to 240 bpm ±5 digits * The Masimo SET SpO2 parameter with LNOP-Adt sensors has been validated for no motion accuracy in human blood studies on healthy adult volunteers in induced hypoxia studies in the range of 70-100% SpO2 against a laboratory CO-oximeter and ECG monitor. This variation equals plus or minus one standard deviation. Plus or minus one standard deviation encompasses 68% of the population. ** The Masimo SET SpO2 parameter eith LNOP-Adt sensors has been validated for motion accuracy in human blood studies on healthy adult volunteers in induced hypoxia studies while performing rubbing and tapping motions at 2 to 4 Hz at an amplitude of 1 to 2 cm and a nonrepetitive motion between 1 to 5 HZ at an amplitude of 2 to 3 cm in induced hypoxia studies in the range of 70-100% SpO2 against a laboratory CO-oximeter and ECG monitor. This variation equals plus or minus one standard deviation. Plus or minus one standard deviation encompasses 68% of the population. The Masimo SET SpO2 parameter with LNOP-Neo Pt sensors has been validated for neonatal motion accuracy in human blood studies on neonates while moving the neonate s foot at 2 to 4 cm against a laboratory CO-oximeter and ECG monitor. This variation equals plus or minus one standard deviation. Plus or minus one standard deviation encompasses 68% of the population. The Masimo SET SpO2 parameter has been validated for low perfusion accuracy in bench top testing against a Biotek index 2 stimulator and Masimo s simulator with signal strengths of greater than 0.02% and a % transmission of greater than 5% for saturations ranging from 70 to 100%. This variation equals plus or minus one standard deviation. Plus or minus one standard deviation encompasses 68% of the population. Low Perfusion Performance 0.02% Pulse amplitude Saturation (% SpO2) ± 2 digits % transmission >5% Pulse rate ± 3 digits Interfering substances: Carboxyhemoglobin may erroneously increase readings. The level of increase is approximately equal to the amount of carboxyhemoglobin present. Dyes, or any substance containing dyes, that change usual arterial pigmentation may cause erroneous readings. Masimo Sensor Accuracy Sensor Model Sensor model SpO2 range 70% to 100% LNOP LNOP ADT LNOP NEO LNOP NEO-L LNOP NEO PT-L LNOP Adtx LNOP Pdtx LNOP DCI LNOP DCIP LNOP Hi Fi-Neo/adult LNOP Hi Fi-Infant/Ped LNOP Blue Infant Thumb/Toe* LNOP YI Multi-Site LNOP DC-195 LNOP TC-I LNCS LNCS TCI LNCS DC-I LNCS DC-IP LNCS Adult Adtx LNCS Ped Pdtx LNCS Infant-L LNCS Neo PT-L Resolution Saturation (% SpO2) 1% Pulse rate (bpm) 1 Sensor Light Source Wavelength** Power Dissipation ± 3 digits without motion Foot ± 3 digits without motion Finger ± 3 digits without motion Foot ± 3 digits without motion Finger ± 2 digits ± 3 digits (for 80-100) without motion ± 4 digits (for 60-80) without motion ± 3.3 digits (for 70-100) without motion Foot/hand ± 3 digits without motion Finger/toe ± 3.5 digits without motion ± 3.5 digits without motion ± 3 digits without motion Infrared: 905 nm (nominal) Red: 660 nm (nominal) Infrared: 27.5 mw (max) Red: 30 mw (max) * Masimo SET Technology with LNOP Blue sensors have been validated for no motion accuracy in human blood studies on neonatal, infant and pediatric patients with congenital, cyanotic cardiac lesions in the range of 60% to 100% SpO2 against a laboratory CO-oximeter. This variation equals plus or minus one standard deviation, which encompasses 68% of the population. ** Information about wavelength range can be especially useful to clinicians.

NIBP Specifications Cuff Pressure Range (Normal operating range) 0 to 290 mmhg (adult/ped) 0 to 145 mmhg (neonate) Blood Pressure Accuracy (SuperSTAT TM NIBP algorithm) Blood Pressure Accuracy (Classic and Auscultatory) Meets ANSI/AAMI Standard SP-10:1992 (mean error 5 mmhg, standard deviation 8 mmhg) Meets ANSI/AAMI Standard SP-10:2002 (mean error 5 mmhg, standard deviation 8 mmhg) Maximum Determination 120 s (adult/ped) 85 s (neonate) Overpressure Cutoff 300 to 330 mmhg (adult/ped) 150 to 165 mmhg (neonate) Blood Pressure Range (SuperSTAT NIBP Algorithm) Systolic MAP Diastolic 30 to 290 mmhg (adult/ped) 30 to 140 mmhg (neonate) 20 to 260 mmhg (adult/ped) 20 to 125 mmhg (neonate) 10 to 220 mmhg (adult/ped) 10 to 110 mmhg (neonate) Blood Pressure Range (Classic and Auscultatory) Systolic MAP Distolic 30 to 245 mmhg (adult/ped) 40 to 140 mmhg (neonate) 15 to 215 mmhg (adult/ped) 30 to 115 mmhg (neonate) 10 to 195 mmhg (adult/ped) 20 to 100 mmhg (neonate) Pulse Rate Range (SuperSTAT NIBP algorithm) 30 to 240 beats/min (adult/ped) 30 to 240 beats/min (neonate) Pulse Rate Range (Classic and Auscultatory) 30 to 200 beats/min (adult/ped) 30 to 220 beats/min (neonate) Pulse Rate Accuracy ± 3.5% or 3 bpm NOTE: All CARESCAPE V100 monitor regulatory and accuracy studies have been performed using CRITIKON Blood Pressure cuffs. The size, shape, and bladder characteristics can affect the performance of the monitor. GE Ohmeda SpO2 Specifications Measurement Range SpO2 1 to 100% Pulse Rate 30 to 250 bpm Perfusion Range 0.03 to 20% Accuracy Saturation Adult Neonate * Adult/Neonate ** Low Perfusion Pulse Rate 70 to 100% whichever is greater, (without motion) 70 to 100% (without motion) 70 to 100% (during clinical motion) 70 to 100% (during clinical low perfusion) Adult/Neonate 30 to 250 bpm: ± 2 digits or ± 2%, whichever is greater, (without motion) 30 to 250 bpm: ± 5 digits (during motion) Low Perfusion 30 to 250 bpm *SpO2 measurement accuracy is based on deep hypoxia studies using OxyTip+ sensors on healthy adult volunteer subjects. Arterial blood samples were analyzed simultaneously on multiple CO-oximeters. This variation equals plus or minus one standard deviation. Plus or minus one standard deviation encompasses 68% of the population. **Applicability: OXY-AF and OXY-AP sensors. NOTE: Accuracy may vary for some sensors; always check the instructions for the sensor. GE Ohmeda Sensor Accuracy Sensor Model SpO2 Range 70% to 100% OxiTip+ OXY-F-UN OXY-W-UN OXY-E-UN OXY-SE OXY-AP OXY-AF OXY-F2-GE OXY-F4-GE OXY-E2-GE OXY-E4-GE Sensor light source Wavelength* Average power Infrared: 930 to 950 nm (nominal) Red 650 to 670 nm (nominal) < 1 mw * Information about wavelength range can be especially useful to clinicians.

2008 General Electric Company All rights reserved. General Electric Company reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. Contact your GE Representative for the most current information. GE and GE Monogram are trademarks of General Electric Company. CARESCAPE, Clinical Information Logistics, Ohmeda, DINAMAP, SuperSTAT and CRITIKON are trademarks of General Electric Company. Alaris, Turbo-Temp and IBAC are trademarks of Cardinal Health Inc. Oxicliq, OxiMAX, Oxisensor, SatSeconds and Nellcor are trademarks of Nellcor Puritan Bennett, Inc. Masimo SET is a trademark of Masimo Corporation. GE Medical Systems Information Technologies, Inc., a General Electric Company, doing business as GE Healthcare. Healthcare Re-imagined GE is dedicated to helping you transform healthcare delivery by driving critical breakthroughs in biology and technology. Our expertise in medical imaging and information technologies, medical diagnostics, patient monitoring systems, drug discovery, and biopharmaceutical manufacturing technologies is enabling healthcare professionals around the world to discover new ways to predict, diagnose and treat disease earlier. We call this model of care Early Health. The goal: to help clinicians detect disease earlier, access more information and intervene earlier with more targeted treatments, so they can help their patients live their lives to the fullest. Re-think, Re-discover, Re-invent, Re-imagine. GE Healthcare P.O. Box 900, FIN-00031 GE, Finland Tel. +358 10 394 11 Fax +358 9 146 3310 www.gehealthcare.com EMEA M1155658 07/08